Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “actual”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Sensitivity Analysis of Salt Storage Cavern Mechanical Integrity Test Parameters

This report examines the sensitivity of salt cavern Mechanical Integrity Tests (MIT) to uncertainties in key test parameters. MIT's are used by cavern operators to detect and quantify leak rates in access wells in underground salt storage caverns and involve a suite of measured and assumed parameters that have a direct impact on the sensitivity of the testing to detect actual leaks from the cavern storage system. Determining the sensitivity of the testing to these different parameters provides a basis for understanding the results from, and informing the design criteria for, this type of testing. Without fully understanding the sensitivity of the test to the testing parameters, it is possible that the test results may not accurately reflect the integrity of the cavern system; an actual leak may be missed, or an intact system may be interpreted as leaking. This report reviews the main parameters included in MITs and examines how selected changes in their values can impact test results. The deviations used in the sensitivity analyses were designed to be within the ranges believed to be similar to those which may be encountered during testing. The results show that small, plausible fluctuations in some of the parameters measured values can have a significant impact on the testing results. Of the parameters studied here, the sensitivity analyses showed the order of importance to be (from highest to lowest): nitrogen-oil interface depth measurement, well bore temperature, well head pressure, and finally the internal geometry of the testing interval.

42 ENGINEERING↗

Domestic Supply Chain of Medical Consumables Needed During COVID-19 Pandemic

This report is an assessment of the availability, demand, and production capability of medical consumables needed to combat the COVID-19 pandemic. We focus here on the ability of the supply chain to increase production to meet demand during peak pandemic conditions. In addition, we report on domestic production efforts and supply chain issues, as well as the propensity of other countries to limit export of needed medical supplies to the United States. In brief, the domestic supply chain and production capability vary greatly depending on the consumable. Some consumables, such as N95 masks or face shields, can likely be nearly fully supplied by domestic production, while other consumables, such as gloves or surgical masks, have little domestic production and thus will depend on imports to meet demand. The assessment pulls primarily from published news sources and company press releases. As such, the demand and production numbers are not precisely known, and some degree of uncertainty exists in them. The total production capability is also often difficult to ascertain from these reports especially as other industries have begun to supplement existing supply chains. In addition, local conditions (including company financial decisions, local public health issues, and political aspects) can vary throughout the pandemic which will affect future production. The report also pulls from estimates of demand and domestic production of some consumables compiled by the White House COVID-19 Supply Chain Taskforce (SCTF) presented by Rear Admiral John Polowczyk before a June 9, 2020 hearing of the Senate Homeland Security and Governmental Affairs Committee. These numbers, where applicable, are likely to be more accurate than those found in public news sources since they are more directly tied to private companies’ actual orders and actual production estimates, as opposed to publicly released estimates. Finally, we note that other issues with the supply chain, including the production of raw materials, increase demand due to industries that have not previously used PPE now using it, and increased domestic production from non-traditional suppliers, make complete picture of a rapidly changing supply chain difficult to obtain. This report attempts to produce an accurate image of the supply and estimated demand, as understood by the authors who are not experts in the medical supply chain.

42 ENGINEERING↗

Dissolution of Fluoride Salts in Hanford Tank Waste

The Direct Feed High-Level Waste (DFHLW) strategy seeks to bypass the Hanford Waste Treatment and Immobilization Plant Pretreatment Facility while retaining some processing functions to maximize waste feed loading and minimize high-level waste (HLW) waste volume. The DFHLW flowsheet needs leaching, washing, and solids concentration operations either in new or existing tanks. The effectiveness and efficiency of sludge washing has a substantial impact on DST space, mission duration, and the evaporation and low-activity waste (LAW) treatment operations required by these large wash-water additions. One target species requiring washing is fluoride. The HLW glass composition limits for fluorine drive operations to dissolve fluoride-bearing salts into the LAW fraction and thereby maximize waste loading in HLW glass. The fluoride in many high-level wastes at Hanford is predominantly in the form of fluoride-salt precipitates: villiaumite (NaF), kogarkoite (Na 3 FSO 4 ), and natrophosphate (Na 7 F(PO 4 ) 2 ·19H 2 O). Fluoride produces melter off-gas that creates corrosion risk in the off-gas system piping, while the sulfate and phosphate in the fluoride double salts kogarkoite and natrophosphate can be detrimental to glass waste loading. Fluoride salts are sparingly soluble, with solubilities ranging from approximately 40 to 130 kg per kL of pure water, and the dissolution kinetics of the three fluoride salts are not well known. Unexpected delays in a tank dissolution process could be encountered as a result of the lack of information about dissolution rates. In addition, if the double salts show transient non-stoichiometric dissolution of fluoride versus phosphate or sulfate, unexpectedly high concentrations of one of these other constituents could be produced. Washington River Protection Solutions authorized Pacific Northwest National Laboratory to collect the available data for fluoride salt dissolution rate, provide a scoping estimate of dissolution time if possible, and identify gaps in the understanding and predictive capability for estimating dissolution time. Open literature and Hanford reports were reviewed to document, understand, and (where possible) evaluate limitations on fluoride salt equilibria and dissolution kinetics, including both mass transport and surface reaction rate. Scoping estimates of dissolution time were made for mass-transfer-controlled dissolution of spherical particles of fluoride salts suspended in liquid. This is not the only potential governing mechanism; dissolution could be substantially slower if the surface reaction rate (the rate of release of ions from the surface) is the controlling mechanism. When the minimum amount of water for complete dissolution is used and the slip velocity between the liquid and suspended particles is less than or equal to the terminal settling velocity, the estimated mass-transfer rates allow 0.1 mm particles of fluoride salt to dissolve in minutes at 25 °C in water containing no other dissolved salts. Much larger solids, such as the 6-mm chunks that have been seen in heels, could take a few hours to more than a week to dissolve. The actual dissolution times will depend strongly on the actual slip velocity, the extent of particle suspension, constraint by surface reaction rates, the ratio of solvent to solid, and the presence of common ions that shift the solubility equilibria to restrict dissolution of fluoride salts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surrogate Assembly 30 cm Drop Test

The 30 cm drop is the remaining NRC normal conditions of transport (NCT) regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. While obtaining data on the actual fuel is not a direct requirement, it provides definitive information which aids in quantifying the risk of fuel breakage resulting from a cask drop from a height of 30 cm or less. The 30 cm drop test with the full-scale surrogate assembly conducted in May 2020 was the last step needed for quantifying the strains on the surrogate assembly rods under NCT. The full-scale surrogate assembly used in the 2020 30 cm drop test was built using a new 17x17 Pressurized Water Reactor (PWR) Westinghouse skeleton filled with the copper rods and 3 zircaloy rods from the full-scale surrogate assembly used in the Multi-Modal Transportation Test (MMTT). Felt pads were attached to the surrogate assembly bottom prior to the 30 cm drop to adequately represent the effects of the impact limiters and the cask. Note that felt "programming material" has been used extensively in past drop tests and is known to be a good material for programming a desired shock pulse. The felt pad configuration was determined during a previous series of tests reported in. The acceleration pulses observed on the surrogate assembly during the test were in good agreement with the expected pulses. This confirmed that during the 30 cm drop the surrogate assembly experienced the same conditions as it would if it was dropped in the cask with the impact limiters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Testing of Particle Erosion and Attrition in CSP Systems

In CSP systems using solid particles for heat transfer, erosion from the falling particles can damage the system components upon impact, and from sliding against the component walls. Furthermore, the resulting attrition of particles can change the thermal performance due to alterations in particle morphology. The research on these issues has been limited to industrial applications, and don’t necessarily coincide with the operating conditions in CSP systems. In this work, we investigated the durability of the particles selected as the heat transfer media, as well as special substrate materials that are of interest as lining materials to the particle storage tanks and hoppers. Three different erosion phenomena were studied: impact, abrasion, and attrition erosion. The low-temperature experiments revealed negligible losses from attrition and abrasion erosion. Although the substrates indicated visible surface damage from impact erosion, the actual material mass loss was small even after a throughput of 500kg of particles 63 days of 1MW CSP plant operation assuming 14 hours per day of operation. Erosion is typically classified as impact, abrasion, or attrition erosion. For example, the CSP systems utilizing solid particles as heat transfer media will likely experience impact erosion on the receiver hopper and heat exchanger walls as the solid particles fall from the reservoir. Additionally, there will be sliding erosion along the receiver walls as particles move through the hopper, and lastly, there will also be attrition erosion as the particles rub against each other. The extent of erosion depends on many factors including but not limited to particle shape and size, material hardness/brittleness and ductility, and particle impact speed and angle. Mechanistic erosion equations that are available in the literature are mostly derived from data pertaining to specific experiments and therefore can’t be applied to all applications without suitable adjustments. Survey of the literature relating to particle-based receivers revealed that the most prevalent approach has been to choose low velocities to limit erosion, but to our knowledge, little effort has been put in to fully characterize erosion at the expected operating conditions. A relatively recent work investigated the erosion of wire mesh proposed for use in a particle receiver, where the results actually showed an increase in mass as oxidation occurred on the mesh surface but the work did not investigate the particle attrition rate, and the erosion rate of a solid substrate. The end goal of this work is to develop a comprehensive particle and substrate durability model that will allow a comprehensive understanding of particle-based CSP operating conditions on component durability.

14 SOLAR ENERGY↗

Integration of a Microturbine Power Conversion Unit in MAGNET

The Microreactor Agile Non-nuclear Experimental Testbed (MAGNET) facility is being constructed at Idaho National Laboratory’s (INL’s) Energy Systems Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will accommodate various types of test articles representative of different microreactor designs. A power conversion unit (PCU) simulator loop was proposed to use the rejected heat from the test article and mimic the thermal hydraulic conditions (e.g., temperature, pressure and flow rate) that would be experienced if an actual Brayton cycle PCU was attached. However, due to the high-estimated cost of the PCU simulator and the availability of a turbogenerator used for previous testing at Sandia National Laboratories, the PCU simulator design was abandoned in favor of integrating an actual PCU into MAGNET. A commercial Capstone C30 was modified by Sandia to use external electrical heating, rather than combustion heating, to provide a power output from 1 to ~30 kWe. The C30 has a single-stage centrifugal combustor, a static radial heat exchanger, and a radial inflow turbine arranged on a single shaft with a high-speed alternator. Since the operating temperature and energy transfer per unit working fluid mass are comparable, the MAGNET PCU will provide researchers with the ability to evaluate the test article heat transfer under representative operating conditions with the transient system behavior associated with a closed Brayton cycle PCU. This report examines the integration of a modified commercial Capstone C30 turbogenerator into MAGNET, outlines a proposed set of tests, and describes future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote methane sensor for emissions from pipelines and compressor stations using chirped-laser dispersion spectroscopy

Leak rates of methane (CH 4 ) from the natural gas supply chain result in lost profit from unsold product, public safety and property concerns due to potential explosion hazards, and a potentially large source of economic damages from legal liabilities. Yet large measurement challenges exist in identifying and quantifying CH 4 leak rates along the vast number and type of components in the natural gas supply chain. This is particularly true of the “midstream” components involved in the gathering, processing, compression, transmission, and storage of natural gas. This project developed and deployed new advances in chirped laser dispersion spectroscopy (CLaDS) to detect methane leaks from pipelines, compressor stations, and other midstream infrastructure from a remote position (standoff detection). The system was deployed from a van to measure fugitive methane leaks from a local compressor station as a proof-of-concept. The technique was validated through mobile laboratory measurements with in-situ sensors as well as controlled releases of methane. The system also mapped a plume from a controlled release of methane by tracking a small unmanned aerial system (sUAS) that carried a corner cube retroreflector which reflected the beam back to the instrument. The drone-based system quantified a leak rate to within 30% of the actual rate and localized the emission location within 5 m of the actual release location at standoff distances of 25-45 m. This sUAS-reflector tracking approach has benefits for mapping leak locations remotely using small drones flying around a facility. Benefits of a commercial sensor with these capabilities include reductions of leaks for pipeline operators (more profit), earlier detection of leaks to avoid catastrophic explosion hazards for public health and to mitigate property damage, and reduced methane emissions to the atmosphere (improving air quality).

03 NATURAL GAS↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history. Actual Titanium values are believed to be less than 10g on any given filter. Actual Tantalum values are believed to be less than 1g on any given filter

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BOPTEST: Initial FRP Test Case Development

To support an emulator model development of Building Optimization Testing (BOPTEST) framework, a team at the US Department of Energy’s Oak Ridge National Laboratory developed a medium-sized office building written in Modelica to serve as a reference test case. The reference test case was modeled based on an actual research platform that represents a typical medium-sized office building. This test case would encourage model-based design and testing of new controllers in which a developer first prototypes and debugs on a model before implementing in the real world. The developed preliminary model and control parameters will be further calibrated and tuned with actual measured data from experiments

42 ENGINEERING↗

The Importance of Ontologies to LANL’s Future Search Capabilities [Slides]

Digitizing physical archives is designed to make documents more accessible. An ontology in this context is a network of discrete concepts (things, people, places, etc.) and, importantly, the relationships that connect them. This will help both the recall and the precision of the search: being able to link to concepts I didn’t type directly into the search box will get more results from a search, while knowing how the concepts are related to each other will make it easier to filter out the stuff that isn’t actually useful. Ontologies make a database more flexible and easier for a user to actually navigate.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Performance Validation of Pulsed Thermal Imaging System for In-Service Applications

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures non-destructively. Pulsed Thermography Imaging (PTI) provides a capability for non-destructive evaluation (NDE) of subsurface defects in arbitrary size structures. The PTI method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PTI method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PTI system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PTI capabilities in detecting microscopic defects in metallic specimens. SS316 and IN718 specimens were developed with a pattern of subsurface calibrated flat bottom hole (FBH) defects with diameters from 500µm to 200µm. FBH’s were created with EDM (electron discharge machining) drill. PTI imaging data was processed Spatial Temporal Denoised Thermal Source Separation (STDTSS) unsupervised machine learning (ML) algorithm. We show that defects as small as 200µm in SS316 and IN718 can be detected with STDTSS algorithm. To the best of our knowledge, these are the smallest detected defects which are reported in literature.

42 ENGINEERING↗

Performance of Pulsed Thermal Tomography Imaging with Machine Learning-Based Classification of Defects in Additively Manufactured Structures

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures non-destructively. Pulsed Thermal Tomography Imaging (PTT) provides a capability for non-destructive evaluation (NDE) of subsurface defects in arbitrary size structures. The PTT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PTT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PTT system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PTT capabilities in detecting and visualizing microscopic defects in metallic specimens. The thermal tomography (TT) algorithm obtains depth reconstructions of spatial effusivity from the data cube of sequentially recorded surface temperatures. However, interpretation of TT images is non-trivial because of blurring of images with increasing depth. To address this challenge, we have developed a deep learning convolutional neural network (CNN) to classify size and orientation subsurface defects in simulated TT images. CNN is trained on a database of TT images created for a set of simulated metallic structures with elliptical subsurface voids. Test of CNN performance demonstrate the ability to classify radii and angular orientation of subsurface defects in TT images. In addition, we have shown that CNN trained on elliptical defects is capable of classifying irregular-shaped defects obtained from scanning electron microscopy (SEM) of stainless steel sections printed with LPBF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Notes on the Variety of Multipactor Patterns

The experimental results on multipactor often are not in a good agreement with theoretical predictions and numerical simulations. The experimental results can noticeably vary from test to test even in the same geometry of electrodes, depending on the material they made of and condition of their surfaces, i.e., secondary emission properties. On the other hand, an actual secondary emission yield (SEY) of electrode material is never known a priory in the experiments. In practice, the SEY data for given material used for multipactor evaluation are obtained in specialized measurements. A difference between actual and tabulated SEY of material may result in a disagreement between pre-dictions and measurements. In this work the impact of the basic SEY characteristic variations on the multipactor dynamics in a variety of coaxial and rectangular waveguides is studied. The study was performed numerically with the use of CST Particle Studio.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results of the Short-Term Analyses of the Salt (Macro) Batch 5 Tank 41H Qualification Sample (Resample)

Savannah River National Laboratory (SRNL) analyzed samples from Tank 41H in November 2021 in support of qualification of Salt Waste Processing Facility (SWPF) Salt Batch 5. This document reports the short-term results of the analyses of samples of Tank 41H. Analysis of the Tank 41H Salt Batch 5 sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. Further sample results will be reported in a future document. This report satisfies part of Deliverable 3 of the Technical Task Request (TTR). After a data review it was found that the original results reported in the revision 0 of this document were actually from Salt Batch 4 (Tank 21H). A new set of samples was sent for analysis to satisfy deliverable 3 of the TTR. The results from the original analyses have been replaced with the recent analyses of the actual Salt Batch 5 sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Long-Term Analyses of the Salt (Macro) Batch 5 Tank 41h Qualification Sample (Resample)

Savannah River National Laboratory (SRNL) analyzed samples from Tank 41H in support of qualification of Salt Water Processing Facility (SWPF) Salt Batch 5. This document reports the long-term results of the analyses of samples of Tank 41H. Analysis of the Tank 41H Salt Batch 5 sample indicated that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. This memo satisfies Deliverable 3 of the Technical Task Request (TTR). After a data review it was found that the original results reports in the revision 0 of this document were actually from Salt Batch 4 (Tank 21H). A new set of samples was sent for analysis to satisfy Deliverable 3 of the TTR. The results from the original analyses have been replaced with the recent analyses of the actual Salt Batch 5 sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗