New Experiments with Hollow Cathode Discharges for Application to Plasma Accelerations
No abstract available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
A modified spray gun, with separate containers for resin and additive components, solves the problems of quick hardening and nozzle clogging. At application, separate atomizers spray the liquids in front of the nozzle face where they blend.
Cavity cathodes for plasma accelerators, investigating discharges for arc currents to 40 amp
Computer search services for transfer of aerospace related technology to industry
The theory of particle acceleration via diffusive shock acceleration (DSA) has been studied in depth by Gosling et al. (1981), van Nes et al. (1984), Mason (2000), Desai et al. (2003), Zank et al. (2006), among many others. Recently, Parker and Zank (2012, 2014) and Parker et al. (2014) using the Advanced Composition Explorer (ACE) shock database at 1 AU explored two questions: does the upstream distribution alone have enough particles to account for the accelerated downstream distribution and can the slope of the downstream accelerated spectrum be explained using DSA? As was shown in this research, diffusive shock acceleration can account for a large population of the shocks. However, Parker and Zank (2012, 2014) and Parker et al. (2014) used a subset of the larger ACE database. Recently, work has successfully been completed that allows for the entire ACE database to be considered in a larger statistical analysis. We explain DSA as it applies to single and multiple shocks and the shock criteria used in this statistical analysis. We calculate the expected injection energy via diffusive shock acceleration given upstream parameters defined from the ACE Solar Wind Electron, Proton, and Alpha Monitor (SWEPAM) data to construct the theoretical upstream distribution. We show the comparison of shock strength derived from diffusive shock acceleration theory to observations in the 50 keV to 5 MeV range from an instrument on ACE. Parameters such as shock velocity, shock obliquity, particle number, and time between shocks are considered. This study is further divided into single and multiple shock categories, with an additional emphasis on forward-forward multiple shock pairs. Finally with regard to forwardforward shock pairs, results comparing injection energies of the first shock, second shock, and second shock with previous energetic population will be given.
The theory of particle acceleration via diffusive shock acceleration (DSA) has been studied in depth by Gosling et al. (1981), van Nes et al. (1984), Mason (2000), Desai et al. (2003), Zank et al. (2006), among many others. Recently, Parker and Zank (2012, 2014) and Parker et al. (2014) using the Advanced Composition Explorer (ACE) shock database at 1 AU explored two questions: does the upstream distribution alone have enough particles to account for the accelerated downstream distribution and can the slope of the downstream accelerated spectrum be explained using DSA? As was shown in this research, diffusive shock acceleration can account for a large population of the shocks. However, Parker and Zank (2012, 2014) and Parker et al. (2014) used a subset of the larger ACE database. Recently, work has successfully been completed that allows for the entire ACE database to be considered in a larger statistical analysis. We explain DSA as it applies to single and multiple shocks and the shock criteria used in this statistical analysis. We calculate the expected injection energy via diffusive shock acceleration given upstream parameters defined from the ACE Solar Wind Electron, Proton, and Alpha Monitor (SWEPAM) data to construct the theoretical upstream distribution. We show the comparison of shock strength derived from diffusive shock acceleration theory to observations in the 50 keV to 5 MeV range from an instrument on ACE. Parameters such as shock velocity, shock obliquity, particle number, and time between shocks are considered. This study is further divided into single and multiple shock categories, with an additional emphasis on forward-forward multiple shock pairs. Finally with regard to forward-forward shock pairs, results comparing injection energies of the first shock, second shock, and second shock with previous energetic population will be given.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This presentation provides a comparison of two methodologies for the solution of reactor kinetic equations, namely for a standard finite difference and a semi-analytical approach. The above-mentioned methods are implemented in a convergence acceleration framework to enhance their efficiency and a comparative study is reported to verify whether it is more convenient to use a rudimentary but fast algorithm (finite difference) with respect to the more refined but computationally intense approach of the semi-analytical method. Performance on several test cases from the literature are compared. (authors)
The applicability of polarized ferroelectric ceramics as a pyroelectric in a pyroelectric accelerator is shown by experiments. The spectra of X-ray radiation of energy up to tens of keV, generated by accelerated electrons, have been measured on heating and cooling of the ceramics in vacuum. It is suggested that curved layers of polarized ferroelectric ceramics be used as elements of ceramic pyroelectric accelerators. Besides, nanotubes and nanowires manufactured from ferroelectric ceramics are proposed for the use in nanometer-scale ceramic pyroelectric nanoaccelerators for future applications in nanotechnologies.
Kinematics nomenclature for physiological accelerations, particularly vestibular applications
Accelerating particles at high gradients with high efficiencies is essential for reduction of size and cost of future accelerators for science and industry. This includes a future multi-TeV e+e- collider for particle, free-electron lasers for basic energy sciences and national security, industrial accelerators for energy and environmental applications, and accelerators for other applications. One way to achieve this is to use advanced externally-powered structures, both laser and RF driven. Working Group 3 (WG3) discussed novel accelerating structures with new geometries, new materials, frequencies from microwave to THz and optical spectrum, and operating conditions from room temperature to cryogenic. Presentations included recent advances in understanding RF breakdown and multipactor phenomena at different frequencies and materials, and other physics limitations to the accelerating gradient. Other relevant topics, such as developing high-gradient photoinjectors, high-efficiency RF power sources, and RF structures for a potential muon collider were discussed also. More details on each of the WG3 topics can be found in the articles published in these proceedings.
Model-based electron accelerator control is the maintenance of optimal parameters of an electron beam such as its orbit, size, and shape, as well as machine parameters such as tunes. It works well when the model reflects reality. SLAC pioneered this technique in SPEAR about thirty decades ago. Similar techniques are now employed in particle accelerator and synchrotron laboratories around the world. There is still an inherently complex problem related to the employment of such techniques to manage the operation and analysis of accelerators and storage rings. The problem arises from the use by those techniques of complex numerical algorithms commonly known as nonlinear solvers that are difficult to control and operate. Lessons learned at SLAC have led to the development of a new, simple-to-use, and iterative nonlinear solver that holds much promise not only in advancing the derivation of errors in accelerators and storage rings at SLAC, but also in its ability to tackle a range of complex engineering problems. A CRADA project was recently completed to build on this experience at SLAC, and to collaborate with an outside company GO AI Services to further develop and validate this nonlinear solver for robust SLAC accelerator. In this report, we present the project report submitted to DOE and SLAC.
Accelerated gradient projection method applied to rocket trajectory optimization for minimizing fuel required for placing payload in circular orbits
Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclear Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating systems provide insight into sources of variability in small field dosimetric measurements reported in the literature.
We consider the stability of a planar accelerating shock front in an exponential atmosphere, a situation that can be described by a self-similar solution. A previous linear instability analysis showed that there are three regimes, depending on the wavelength of the perturbation along the direction of the shock front: at long wavelengths the shock is unstable, at intermediate wavelengths it is overstable, and at short wavelenghts it is stable, where the characteristic length is set by the initial density scale height. We have carried out numerical simulations of such an accelerating shock front and have confirmed the results of the semianalytic linear analysis in the linear regime. In the nonlinear regime, the evolution again depends on the three wavelength domains. At long wavelengths, the instability continuously grows but the flow remains smooth, and at short wavelengths, the flow is stable. The intermediate wavelength, overstable regime shows more complex evolution. The growing linear oscillations saturate soon after entering the nonlinear regime and the oscillations continue with the same approximate period. The shock front develops moving points of intersection, which generate weak shock fronts and density and pressure structure in the immediate postshock flow. The density fluctuations, with a contrast of a factor of 2-3, become frozen into the downstream flow. The growth of the instability is slow, so substantial initial perturbations are needed; thesemay be present in Type II supernovae with red supergiant progenitor stars which have outer convective regions. The clumping in the outer supernova atmosphere may affect spectral line formation and may play a role in the formation of fast knots.
Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.
A simple model is introduced for the fields of a chirped laser pulse. As an application, dynamics of laser-acceleration of a single electron by the fields of a pulse, with a sin4 envelope, is investigated. Multi-GeV energy gains from interaction with pulses of peak intensity I0~1020 W/cm 2 , are reported.