Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Massive soliton stars

The structure of nontopological solutions of Einstein field equations as proposed by Friedberg, Lee, and Pang (1987) is examined. This analysis incorporates finite temperature effects and pair creation. Quarks are assumed to be the only species that exist in interior of soliton stars. The possibility of primordial creation of soliton stars in the incomplete decay of the degenerate vacuum in early universe is explored. Because of dominance of pair creation inside soliton stars, the luminosity of soliton stars is not determined by its radiative transfer characteristics, and the surface temperature of soliton stars can be the same as its interior temperature. It is possible that soliton stars are intense X-ray radiators at large distances. Soliton stars are nearly 100 percent efficient energy converters, converting the rest energy of baryons entering the interior into radiation. It is possible that a sizable number of baryons may also be trapped inside soliton stars during early epochs of the universe. In addition, if soliton stars exist they could assume the role played by massive black holes in galactic centers.

Chiu, Hong-Yee↗

Evaluation of Late Effects of Heavy-Ion Radiation on Mesenchymal Stem Cells

The overall objective of this recently funded study is to utilize well-characterized model test systems to assess the impact of pluripotent stem cell differentiation on biological effects associated with high-energy charged particle radiation. These stem cells, specifically mesenchymal stem cells (MSCs), have the potential for differentiation into bone, cartilage, fat, tendons, and other tissue types. The characterization of the regulation mechanisms of MSC differentiation to the osteoblastic lineage by transcription factors, such as Runx2/Cbfa1 and Osterix, and osteoinductive proteins such as members of the bone morphogenic protein family are well established. More importantly, for late biological effects, MSCs have been shown to contribute to tissue restructuring and repair after tissue injury. The complex regulation of and interactions between inflammation and repair determine the eventual outcome of the responses to tissue injury, for which MSCs play a crucial role. Additionally, MSCs have been shown to respond to reactive oxygen species, a secondary effector of radiation, by differentiating. With this, we hypothesized that differentiation of MSCs can alter or exacerbate the damage initiated by radiation, which can ultimately lead to late biological effects of misrepair/fibrosis which may ultimately lead to carcinogenesis. Currently, studies are underway to examine high-energy X-ray radiation at low and high doses, approximately 20 and 200 Rad, respectively, on cytogenetic damage and gene modulation of isolated MSCs. These cells, positive for MSC surface markers, were obtained from three persons. In vitro cell samples were harvested during cellular proliferation and after both cellular recovery and differentiation. Future work will use established in vitro models of increasing complexity to examine the value of traditional 2D tissue-culture techniques, and utilize 3D in vitro tissue culture techniques that can better assess late effects associated with radiation.

Gonda, S.R.↗

Spectral observations of the soft X-ray background with solid-state detectors - Evidence for line emissions

The soft X-ray radiation from several regions of the sky was observed with solid-state detectors Si(Li) between 0.3 and 1.2 keV during two rocket flights. The thermal nature of the diffuse emission coming from the hot bubble surrounding the solar system is confirmed by the observation of C V-C VI and O VII lines which are typical of a temperature of about 10 to the 6th K. Evidence for the existence of a weak component at a higher temperature is given. This component, well visible in the high latitude spectra, could be produced by a hot galactic halo. In the direction of the enhancement region centered on the North Polar Spur, the radiation excess spectra are well represented by a two-temperature plasma model with rather standard abundances. The two components have temperatures of 10 to the 6th and 4.7 x 10 to the 6th K.

Rocchia, R.↗

Multifrequency observations of the BL Lacertae objects OQ 530 and ON 325

Spectral measurements of the two BL Lac objects OQ 530 and ON 325 are presented. The measurements were taken at frequencies ranging from radio to ultraviolet. Both sources show spectral curvature between the infrared and ultraviolet frequencies. The intensity and spectral shape of OQ 530 vary, but the spectral shape of ON 325 appears to remain constant during intensity variability. A nonthermal theoretical model of jet emission is developed which incorporates both the spectral and time variability data. The model predicts that ON 325 radiates at X-ray frequencies with Compton radiation dominating over synchrotron emission. The angular size of the jet emission is predicted to be less than 0.1 milli-arcsec at high radio frequencies.

Worrall, D. M.↗

Accreting, Isolated Neutron Stars: Preheated of Infalling Gas and Cometary H II Regions - 3

Nearby, isolated, old neutron stars (IONSs) accreting interstellar material might be detectable as sources of UV and soft X-ray radiation. We investigate the interaction between this radiation field and the surrounding medium, assumed to consist of purely hydrogen and helium. This interaction results in a cometary H II region around the star which we model in detail by including all the relevant time-dependent ionization, recombination, heating, and cooling processes. We find that preheating of the ambient gas to temperatures higher than 10(exp 4) K may significantly quench the accretion rate onto these neutron stars, thereby reducing the IONS number counts in the EUV and soft X-ray bands predicted by previous investigations. However, the reprocessing of hard radiation by the surrounding H II regions may enhance the detectability of IONSs at optical wavelengths. Searches for nearby accreting IONSs are currently being undertaken.

Madau, Piero↗

Absorption and emission of extraordinary-mode electromagnetic waves near cyclotron frequency in nonequilibrium plasmas

An investigation is presented of two cases: (1) weakly relativistic electrons with a loss-cone type distribution, and (2) electrons with a drift velocity parallel to the ambient magnetic field. Numerical computations are given for physical parameters close to those in the polar region of the earth magnetosphere and laboratory experiments, with attention to the fast extraordinary-mode radiation whose frequency is near that of the electron cyclotron frequency. The fast extraordinary mode can escape from a strong field region to the weaker field region and may therefore be measured outside the plasma. It is found that the X mode radiation can be amplified by means of a cyclotron maser effect when the electrons have a loss-cone distribution, and it is concluded that, when the electron energy is sufficiently high, the X mode cutoff frequency may be lower than the cyclotron frequency.

Wu, C. S.↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Extended range X-ray telescope

An X-ray telescope system is described which is comprised of a tubular mount having a collecting region remote from the one axial end. A soft X-ray/XUV subsystem associated with the collecting region directs only relatively soft, near on-axis X-rays/XUV radiation incident on a first portion of the collecting region into a first detector sensitive to relatively soft X-rays/XUV radiation. A hard X-ray subsystem associated with the collecting region directs only relatively hard near on-axis X-rays incident on a second portion of the collecting region into a second detector sensitive to relatively hard X-rays.

Hoover, R. B.↗

Optimization of selenium in CdZnTeSe quaternary compound for radiation detector applications

X- and gamma-ray detectors are increasingly becoming essential tool for science and technology in various fields include homeland security, nonproliferation, nuclear security, medical imaging, astrophysics, and high energy physics. Cd 1-x Zn x Te 1-y Se y (CZTS) is emerging as a next-generation compound semiconductor for such applications. CZTS was found to possesses a very low concentration of Te inclusions and free from sub-grain boundary networks. Being a quaternary compound with varying alloy composition, optimization of the composition was performed to determine the minimum amount of selenium required to produce CZTS with reduced defects. The optimized composition was found to be x=0.10 and y=0.02, i.e., Cd 0.9 Zn0.1Te 0.98 Se 0.02 , for excellent material properties as a radiation detector. The resulting material was free from sub-grain boundary networks and with a highly reduced concentration of Te inclusions. The bulk dark resistivity obtained was in the range of 1-3x1010 ohm-cm with the highest achieved mobility-lifetime product of ~6.6x10-3 cm2/V for the optimized CZTS composition. Impurity analyses were performed by the Glow Discharge Mass Spectroscopy (GDMS) technique, and the results showed relatively high impurity concentrations compared to commercial detector-grade CdZnTe. Thus, CZTS has room for further improvement with additional purification of the starting materials.

36 MATERIALS SCIENCE↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

H-alpha and hard X-ray development in two-ribbon flares

Morphological features of two-ribbon flares have been studied, using simultaneous ISEE-3 hard X-ray records and high-resolution Big Bear H-alpha movies for more than 20 events. Long-lasting and complex hard X-ray bursts are almost invariably found associated with flares of the two-ribbon type. At least three events are found, namely March 31, 1979, April 10, 1980, and July 1, 1980, where the occurrence of individual spikes in hard X-ray radiation coincides with suddenly enhanced H-alpha emission covering the sunspot penumbra. There definitely exist important (greater than or equal to 1 B) two-ribbon flares without significant hard X-ray emission.

Dwivedi, B. N.↗

X-ray luminosity and the hydrogen-line ratios of quasars and Seyfert galaxies

New observations of the Ly-alpha/H-alpha ratio in a set of X-ray-selected active galactic nuclei and an archival study of International Ultraviolet Explorer (IUE) observations of Ly-alpha in low-redshift quasars and Seyfert galaxies have been used to form a large sample (49 objects) for studying the influence of soft X-rays on the enhancement of Balmer emission in the broad-line region. In common models of broad-line clouds, the Balmer lines are formed deep in the interior, largely by collisional excitation. Heating within the clouds is provided by soft X-ray radiation, while Ly-alpha is formed mainly by recombination after photoionization. The ratio Ly-alpha/H-alpha is expected to depend weakly on the ratio of ionizing ultraviolet luminosity to X-ray luminosity, L(UV)/L(x). If the Ly-alpha luminosity is used as a measure of L(UV), a weak dependence of Ly-alpha/H-alpha on the X-ray luminosity is found (valid at the 94 percent confidence level), similar to previous results. Future definitive studies depend more critically on contemporaneous observations and better internal reddening estimates rather than a larger sample size.

Kriss, G. A.↗

Pulsar Polar Cap Heating and Surface Thermal X-ray Emission: Inverse Compton Radiation Pair Fronts - 2

We investigate the production of electron-positron pairs by inverse Compton scattered (ICS) photons above a pulsar polar cap (PC) and calculate surface heating by returning positrons. This paper is a continuation of our self-consistent treatment of acceleration, pair dynamics, and electric field screening above pulsar PCs. We calculate the altitude of the inverse Compton pair-formation fronts, the flux of returning positrons, and present the heating efficiencies and X-ray luminosities. We revise pulsar death lines implying cessation of pair formation, and present them in surface magnetic field-period space. We find that virtually all known radio pulsars are capable of producing pairs by resonant and nonresonant ICS photons radiated by particles accelerated above the PC in a pure star-centered dipole field, so that our ICS pair death line coincides with empirical radio pulsar death. Our calculations show that ICS pairs are able to screen the accelerating electric field only for high PC surface temperatures and magnetic fields. We argue that such screening at ICS pair fronts occurs locally, slowing but not turning off acceleration of particles until screening can occur at a curvature radiation (CR) pair front at higher altitude. In the case where no screening occurs above the PC surface, we anticipate that the pulsar gamma-ray luminosity will be a substantial fraction of its spin-down luminosity. The X-ray luminosity resulting from PC heating by ICS pair fronts is significantly lower than the PC heating luminosity from CR pair fronts, which dominates for most pulsars. PC heating from ICS pair fronts is highest in millisecond pulsars, which cannot produce CR pairs, and may account for observed thermal X-ray components in the spectra of these old pulsars.

Harding, Alice K.↗

X-ray sources in stellar winds

A model of a binary X-ray source immersed in a stellar wind from its companion star is considered. The geometry of the constant ionization and temperature contours in the model is discussed, and X-ray radiative transfer through the wind is described. The results are applied to make predictions about the presence and variability of iron K-shell fluorescence lines, to explain the light curve of Cen X-3 during a 'low' to 'high' state transition in July 1972, and to predict variability with orbital phase of resonance ultraviolet lines such as N V at 1238 and 1242 A from the binary system.

Hatchett, S.↗

The polarization and directivity of solar-flare hard X-ray bremsstrahlung from a thermal source

The polarization and directivity of hard X-ray bremsstrahlung from a thermal source consisting of a region in which a thermal flux drives a pair of steel collisionless conduction fronts were evaluated. The conduction fronts are symmetrically driven from a central region, heated by the flare energy dissipation process. By comparing results with similar calculations based on a nonthermal thick-target electron beam model of the source, it was aimed to determine the degree to which the observed polarization and directivity of solar flare hard X-rays favor either model. Results which exhibit significant polarization and directivity of the hard X-ray radiation emitted by the source are produced by using Maxwellian electron-phase-space distribution functions modified to take into account a directional heat flux and a steady direct current in the X-ray source, and a fully relativistic treatment of the bremsstrahlung emission process. The results are consistent with solar hard X-ray anisotropy and polarization observations to date, although these observations are too crude to be conclusive.

Emslie, A. G.↗

Beating absorption in solid-state high harmonics

Since the new millennium coherent extreme ultra-violet and soft x-ray radiation has revolutionized the understanding of dynamical physical, chemical and biological systems at the electron’s natural timescale. Unfortunately, coherent laser-based upconversion of infrared photons to vacuum-ultraviolet and soft x-ray high-order harmonics in gaseous, liquid and solid targets is notoriously inefficient. In dense nonlinear media, the limiting factor is strong re-absorption of the generated high-energy photons. Here we overcome this limitation by generating high-order harmonics from a periodic array of thin one-dimensional crystalline silicon ridge waveguides. Adding vacuum gaps between the ridges avoids the high absorption loss of the bulk and results in a ~ 100-fold increase of the extraction depth. As the grating period is varied, each high harmonic shows a different and marked modulation, indicating their waveguiding in the vacuum slots with reduced absorption. Looking ahead, our results enable bright on-chip coherent short-wavelength sources and may extend the usable spectral range of traditional nonlinear crystals to their absorption windows. Potential applications include on-chip chemically-sensitive spectro-nanoscopy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation furnace for synchrotron dark-field x-ray microscopy experiments

We present a multi-purpose radiation furnace designed for x-ray experiments at synchrotrons. The furnace is optimized specifically for dark-field x-ray microscopy (DFXM) of crystalline materials at beamline ID06 of the European Synchrotron Radiation Facility. The furnace can reach temperatures above 1200 °C with a thermal stability better than 10 °C, with heating and cooling rates up to 30 K/s. The non-contact heating design enables samples to be heated either in air or in a controlled atmosphere contained within a capillary tube. The temperature was calibrated via the thermal expansion of an α-iron grain. Temperature profiles in the y and z axes were measured by scanning a thermocouple through the focal spot of the radiation furnace. In the current configuration of the beamline, this furnace can be used for DFXM, near-field x-ray topography, bright-field x-ray nanotomography, high-resolution reciprocal space mapping, and limited powder diffraction experiments. As a first application, we present a DFXM case study on isothermal heating of a commercially pure single crystal of aluminum.

Yildirim, C. (ORCID:0000000249690685)↗

X ray based displacement measurement for hostile environments

A new method on noncontacting, high temperature extensometry based on the focus and scanning of x rays is currently under development and shows great promise of overcoming limitations associated with available techniques. The chief advantage is the ability to make undisturbed measurements through stratified or flowing gases, smoke, and flame. The system is based on the ability to focus and scan low energy, hard x rays such as those emanating from copper or molybdenum sources. The x rays are focused into a narrow and intense line image which can be scanned onto targets that fluoresce secondary x ray radiation. The final goal of the system is the ability to conduct macroscopic strain measurements in hostile environments by utilizing two or more fluorescing targets. Current work is limited to displacement measurement of a single target with a resolution of 1.25 micro-m and a target temperature of 1200 C, directly through an open flame. The main advantage of the technique lies in the penetrating nature of x rays which are not affected by the presence of refracting gas layers, smoke, flame, or intense thermal radiation, all of which could render conventional extensometry methods inoperative or greatly compromise their performance.

Canistraro, Howard A.↗