Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water Impact Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

IASCC of 304 SS in BWR environments: Effects of post-irradiation annealing and surface condition

To investigate the impact of low-temperature post-irradiation annealing (PIA) on the stress corrosion cracking of neutron-irradiated 304 stainless steel, constant extension rate tests were conducted in simulated boiling water reactor normal water chemistry (BWR-NWC) and hydrogenated water chemistry (HWC) environments. Ten tensile samples, comprising five as-irradiated and five PIA specimens, were prepared by electropolishing the gauge section of electric discharge machined (EDM) samples. Here, the annealing treatment reduced the yield strength from approximately 550 MPa to around 425 MPa and significantly restored the ductility and the strain hardening capability of the alloy. Consequently, the susceptibility of this material to irradiation-assisted stress corrosion cracking (IASCC) was effectively mitigated, which is more prominent in HWC, as evident from fractography, which indicated a decreased propensity for intergranular (IG) fracture. Furthermore, it was observed that the polished surface facilitated crack initiation more readily than the EDM surface, suggesting that the EDM process suppressed crack initiation to some extent.

Crack initiation↗

Advanced underwater lift device

Flexible underwater lift devices ('lift bags') are used in underwater operations to provide buoyancy to submerged objects. Commercially available designs are heavy, bulky, and awkward to handle, and thus are limited in size and useful lifting capacity. An underwater lift device having less than 20 percent of the bulk and less than 10 percent of the weight of commercially available models was developed. The design features a dual membrane envelope, a nearly homogeneous envelope membrane stress distribution, and a minimum surface-to-volume ratio. A proof-of-concept model of 50 kg capacity was built and tested. Originally designed to provide buoyancy to mock-ups submerged in NASA's weightlessness simulators, the device may have application to water-landed spacecraft which must deploy flotation upon impact, and where launch weight and volume penalties are significant. The device may also be useful for the automated recovery of ocean floor probes or in marine salvage applications.

Flanagan, David T.↗

Marine & hydrokinetic technology development.

The Wind and Water Power Program supports the development of marine and hydrokinetic devices, which capture energy from waves, tides, ocean currents, the natural flow of water in rivers, and marine thermal gradients, without building new dams or diversions. The program works closely with industry and the Department of Energy's national laboratories to advance the development and testing of marine and hydrokinetic devices. In 2008, the program funded projects to develop and test point absorber, oscillating wave column, and tidal turbine technologies. The program also funds component design, such as techniques for manufacturing and installing coldwater pipes critical for ocean thermal energy conversion (OTEC) systems. Rigorous device testing is necessary to validate and optimize prototypes before beginning full-scale demonstration and deployment. The program supports device testing by providing technology developers with information on testing facilities. Technology developers require access to facilities capable of simulating open-water conditions in order to refine and validate device operability. The program has identified more than 20 tank testing operators in the United States with capabilities suited to the marine and hydrokinetic technology industry. This information is available to the public in the program's Hydrodynamic Testing Facilities Database. The program also supports the development of open-water, grid-connected testing facilities, as well as resource assessments that will improve simulations done in dry-dock and closed-water testing facilities. The program has established two university-led National Marine Renewable Energy Centers to be used for device testing. These centers are located on coasts and will have open-water testing berths, allowing researchers to investigate marine and estuary conditions. Optimal array design, development, modeling and testing are needed to maximize efficiency and electricity generation at marine and hydrokinetic power plants while mitigating nearby and distant impacts. Activities may include laboratory and computational modeling of mooring design or research on device spacing. The geographies, resources, technologies, and even nomenclature of the U.S. marine and hydrokinetic technology industry have yet to be fully understood or defined. The program characterizes and assesses marine and hydrokinetic devices, and then organizes the collected information into a comprehensive and searchable Web-based database, the Marine and Hydrokinetic Technology Database. The database, which reflects intergovernmental and international collaboration, provides industry with one of the most comprehensive and up-to-date public resources on marine and hydrokinetic devices.

13 HYDRO ENERGY↗

Principles of water oxidation and O2-based hydrocarbon transformation by multinuclear catalytic sites

Abstract The central thrust of this integrated experimental and computational research program was to obtain an atomistic-level understanding of the structural and dynamic factors underlying the design of catalysts for water oxidation and selective reductant-free O2-based transformations. The focus was on oxidatively robust polyoxometalate (POM) complexes in which a catalytic active site interacts with proximal metal centers in a synergistic manner. Thirty five publications in high-impact journals arose from this grant. I. Developing an oxidatively and hydrolytically stable and fast water oxidation catalyst (WOC), a central need in the production of green fuels using water as a reductant, has proven particularly challenging. During this grant period we have designed and investigated several carbon-free, molecular (homogenous), oxidatively and hydrolytically stable WOCs, including the Rb8K2[{Ru4O4(OH)2(H2O)4}(γ-SiW10O36)2]·25H2O (1) and [Co4(H2O)2(α-PW9O34)2]10- (2). Although complex 1 is fast, oxidatively and hydrolytically stable WOC, Ru is neither abundant nor inexpensive. Therefore, development of a stable and fast carbon-free homogenous WOC, based on earth-abundant elements became our highest priority. In 2010, we reported the first such catalyst, complex 2. This complex is substantially faster than 1 and stable under homogeneous conditions. Recently, we have extended our efforts and reported a V2-analog of the complex 2, i.e. [Co4(H2O)2(α-VW9O34)2]10- (3), which shows an even greater stability and reactivity. We succeeded in: (a) immobilizing catalysts 1 and 2 on the surface of various electrodes, and (b) elucidating the mechanism of O2 formation and release from complex 1, as well as the Mn4O4L6 “cubane” cluster. We have shown that the direct O-O bond formation is the most likely pathway for O2 formation during water oxidation catalyzed by 1. II. Oxo transfer catalysts that contain two proximal and synergistically interacting redox active metal centers in the active site form another part of considerable interest of our grant because species with such sites [including methane monooxygenase (MMO) and more] are some of the most effective oxygenase catalysts known. Our team conducted the following research on γ-M2-Keggin complexes: (a) investigated stability of the trimer [{Fe3(OH)3(H2O)2}3(γ-SiW10O36)3]15-, 4, in water, and developed the chemistry and catalysis of the di-iron centered POM, [γ(1,2)-SiW10{Fe(OH)}2O38]6-, 5, in organic solvents (Figure 2). We also study the thermodynamic and structural stability of γ-M2-Keggin in aqueous media for different M’s (d-electron metals). We have defined two structural classes of POMs with proximally bound d-electron metal centers. We refer to these structural isomers of the {γ-M2SiW10} family of POMs as “in-pocket” and “out-of pocket”. We have elucidated the factors controlling the structure and stability of the V, Fe, Ru, Tc, Mo and Rh derivatives of [(SiO4)M2(OH)2W10O32]4- using a range of computational tools. We have: (a) demonstrated that heteroatom X in these polyanions may function as an “internal switch” for defining the ground electronic states and, consequently, the reactivity of the γ-M2-Keggin POM complexes; (b) elucidated reactivity of divacant lacunary species and polyperoxotungstates (PPTs), {Xn+O4[WO(O2)2]4}n-, which could be degradation products of γ-M2-Keggin complexes in aqueous media; (c) elucidated the role of the POM ligand in stabilization of {Ru2} and {(Ru-oxo)2} fragments in the reactant and product of the reaction of {γ-[(Xn+O4)Ru2(OH)2W10O32]}(8-n)- (where X = Si4+, P5+ and S6+) with O2, and (d) the mechanisms of olefin epoxidation catalyzed by these di-d-transition metal substituted and divacant lacunary γ-M2-Keggin complexes. III. Complementing the efforts presented above was the development of less time-consuming but reasonably accurate computational methods allowing one to explore more deeply large catalytic systems. We developed Reactive Force Field (ReaxFF) to study interaction of the targeted POMs with water, proton and hydroxide ions in the liquid phase. We tested our ReaxFF parameters on the Lindqvist POMs, M6O19n-, where M = Nb and Ta. These parameters are made available as part of the ReaxFF code. In addition, we have developed parameters for Sc, Ti, Fe, Co and Ni in combination with H, C, N, O, as well as the same metal (M-M) for the spin-polarized self-consistent-charge density-functional tight-binding (DFTB) method. Test calculations showed that the DFTB method with the present parameters in most cases reproduces structural properties very well. These parameters are made available as part of the DFTB code. Thus, this DOE BES funded research project has clarified several key areas impacting (a) water oxidation and O2-based hydrocarbon transformation, (b) stabilization of key structures and catalytic intermediates in such processes, (c) immobilization of molecular catalysts on metal oxide surfaces, and (d) application of optimal computational methods to study reaction dynamics in large systems.

58 GEOSCIENCES↗

CO2-Binding Organic Liquids Gas Capture with Polarity-Swing-Assisted Regeneration Full Technology Feasibility Study B1 - Solvent-based Systems

PNNL, Fluor Corporation and Queens University (Kingston, ON) successfully completed a three year comprehensive study of the CO2BOL water-lean solvent platform with Polarity Swing Assisted Regeneration (PSAR). This study encompassed solvent synthesis, characterization, environmental toxicology, physical, thermodynamic and kinetic property measurements, Aspen Plus™ modeling and bench-scale testing of a candidate CO2BOL solvent molecule. Key Program Findings The key program findings are summarized as follows: • PSAR favorably reduced stripper duties and reboiler temperatures with little/no impact to absorption column • >90% CO2 capture was achievable at reasonable liquid-gas ratios in the absorber • High rich solvent viscosities (up to 600 cP) were successfully demonstrated in the bench-scale system. However, the projected impacts of high viscosity to capital cost and operational limits compromised the other levelized cost of electricity benefits. • Low thermal conductivity of organics significantly increased the required cross exchanger surface area, and potentially other heat exchange surfaces. • CO2BOL had low evaporative losses during bench-scale testing • There was no evidence of foaming during bench scale testing • Current CO2BOL formulation costs project to be $35/kg • Ecotoxicity (Water Daphnia) was comparable between CO2BOL and MEA (169.47 versus 103.63 mg/L) • Full dehydration of the flue gas was determined to not be economically feasible. However, modest refrigeration (13 MW for the 550 MW reference system) was determined to be potentially economically feasible, and still produce a water-lean condition for the CO2BOLs (5 wt% steady-state water loading). • CO2BOLs testing with 5 wt% water loading did not compromise anhydrous performance behavior, and showed actual enhancement of CO2 capture performance. • Mass transfer of CO2BOLs was not greatly impeded by viscosity • Facile separation of antisolvent from lean CO2BOL was demonstrated on the bench cart • No measurable solvent degradation was observed over 4 months of testing – even with 5 wt% water present

Heldebrant, David J↗

Assessing the Long-Term Stability of Anion Exchange Membranes for Electrochemical CO 2 Reduction

Materials and cell components used in CO 2 electrolysis have largely been adapted from technologies initially developed for water electrolysis and fuel cells. However, electrochemical CO 2 reduction introduces distinct material challenges due to the unique chemical environment in this process. Here, in this study, we conducted ex-situ 1000 h stability tests on commonly used anion exchange membranes, exposing them exclusively to electrolytes and organic molecules used or produced during CO 2 electrolysis, at concentrations relevant to and compatible with postseparation processes. Notably, 15% w/w n-propanol and 5 M acetic acid caused complete dissolution or partial disintegration of the membranes unless cross-linking was present and remained stable throughout the test. When the membranes stayed physically intact, most of them exhibited excellent chemical stability in alkaline medium containing alcohols or formic acid, which was confirmed by vibrational spectroscopy and ion exchange capacity measurements. However, exposure to alcohol-and acid-containing solutions led to a substantial increase in swelling and water uptake, with potential implications for mechanical stability, ion/product crossover, and compression management of adjacent components. The potential effects of CO 2 electroreduction products on membrane stability, their subsequent impact on electrolyzer performance, and mitigation strategies are discussed.

CO2RR↗

Electron beam irradiation of 1,4 dioxane

Electron beam irradiation produces both, reducing and oxidizing species which facilitate the reduction of contaminants found in water and wastewater. To investigate the impact of electron beam on 1,4-dioxane, a widely used solvent which has been declared as a probable human carcinogen by the U.S. Environmental Protection Agency, a beamline was designed and commissioned at the Upgraded Injector Test Facility at Jefferson Lab. Here, wastewater samples can be irradiated with a beam energy up to 10 MeV and a beam current of up to 100 nA. Beam acceleration is achieved by two superconducting radio-frequency cavities cooled by liquid helium in a cryomodule. A beam spot with a diameter of ~5 cm was produced at the target location using a pair of raster coils. Electron beam irradiation studies were performed using 1,4-dioxane in two different matrices, de-ionized water and secondary effluent wastewater, and for two concentrations, 10 microg/L and 100 microg/L. The concentration of 1,4-dioxane after irradiation was measured as a function of dose.

Li, Xi↗

Contaminant Cation Effect on Oxygen Transport through the Ionomers of Polymer Electrolyte Membrane Fuel Cells

We characterized the effects of cobalt (Co 2+ ) and other cation contaminants on the oxygen (O 2 ) transport properties of the PFSA ionomer used in polymer electrolyte membrane fuel cells (PEMFCs) and gained insight into the mechanisms by which contaminant cations inhibit O 2 transport. Such cations can be released by alloy catalysts and environmental conditions and pose a significant challenge to maintaining high current density performance with low platinum (Pt) loadings. We used a test cell capable of isolating the ionomer from the membrane electrode assembly (MEA), allowing for O 2 transport resistance (R O2 ) measurements using a limiting current technique. We contaminated ionomer membranes with Li + , Na + , Ni 2+ , Co 2+ , and Ce 3+ and found a general increase in R O2 for increased contamination levels and decreased water activity. In addition, our Co 2+ results indicated distinct concentration-dependent regimes. The other cation-form ionomers allowed us to separate the impacts of ion pair strength, multivalency, and reduced water uptake. We believe that these factors cause a more compressed hydrophilic domain and tortuous O 2 diffusion path, and a commensurate increase in R O2 . Lastly, we studied the impact of Co 2+ on an operating PEMFC and found an increase in R O2 consistent with the results of our isolated membrane tests.

25 ENERGY STORAGE↗

Using Financial Contracts to Facilitate Informal Leases Within a Western United States Water Market Based on Prior Appropriation

The ability to reallocate water to higher-value uses during drought is an increasingly important “soft-path” tool for managing water resources in an uncertain future. In most of the Western United States, state-level water market institutions that enable reallocation also impose substantial transaction costs on market participants related to regulatory approval and litigation. These transaction costs can be prohibitive for many participants in terms of both costs and lengthy approval periods, limiting transfers and reducing allocation efficiency, particularly during drought crises periods. This manuscript describes a mechanism to reduce transaction costs by adapting an existing form of informal leases to facilitate quicker and less expensive transfers among market participants. Instead of navigating the formal approval process to lease a water right, informal leases are financial contracts for conservation that enable more junior holders of existing rights to divert water during drought, thereby allowing the formal transfer approval process to be bypassed. The informal leasing approach is tested in the Upper Colorado River Basin, where drought and institutional barriers to transfers lead to frequent shortages for urban rights holders along Colorado's Front Range. Informal leases are facilitated via option contracts that include adaptive triggers and that define volumes of additional, compensatory, releases designed to mitigate impacts to instream flows and third parties. Results suggest that more rapid reallocation of water via informal leases could have resulted in up to $222 million in additional benefits for urban rights holders during the historical period 1950–2013.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SRNL SHELF LIFE STUDIES - SCC STUDIES AT ROOM TEMPERTURE [stress corrosion cracking ]

Phase II, Series 2 corrosion testing performed by the Savannah River National Laboratory (SRNL) for the Department of Energy 3013 container has been completed. The corrosion tests are part of an integrated plan conducted jointly by Los Alamos National Laboratory and the Savannah River Site. SRNL was responsible for conducting corrosion studies in small-scale vessels to address the influence of salt composition, water loading, and type of oxide/salt contact on the relative humidity inside a 3013 container and on the resulting corrosion of Type 304L and 316L stainless steel (304L and 316L). This testing was conducted in two phases: Phase I evaluated a broad spectrum of salt compositions and initial water loadings on the salt mixtures exposed to 304L and 316L and the resulting corrosion; Phase II evaluated the corrosion of 304L at specific water loadings and a single salt composition. During Phase I testing at high initial moisture levels (0.35 to 1.24 wt%)a, the roomtemperature corrosion of 304L exposed to a series of plutonium oxide/chloride salt mixtures ranged from superficial staining to pitting and stress corrosion cracking (SCC). 304L teardrop coupons that exhibited SCC were directly exposed to a mixture composed of 98 wt % PuO2, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl2. Cracking was not observed in a 316L teardrop coupon. Pitting was also observed in this environment for both 304L and 316L with depths ranging from 20 to 100 μm. Neither pitting nor SCC was observed in mixtures with a greater chloride salt concentration (5 and 28 wt%). These results demonstrated that for a corrosive solution to form a balance existed between the water loading and the salt chloride concentration. This chloride solution results from the interaction of loaded water with the hydrating CaCl2 salt. In Phase II, Series 1 tests, the SCC results were shown to be reproducible with cracking occurring in as little as 85 days. The approximate 0.5 wt% moisture level was found to result in an initial relative humidity of ~55% within the small-scale vessels. Pits were found to be associated with cracks and appeared to act as initiators for the cracking. In a vapor-space only exposure, the weld oxide, which results from the TIG closure weld used to fabricate the teardrop coupon, was also shown to be more susceptible to pitting corrosion than a surface free from weld oxide. This result has important implications for the closure weld of the 3013 inner can since the weld oxide on the can internal surface cannot be removed. The results from the Phase II, Series 2 tests further demonstrated the significance of forming a solution with a critical chloride concentration for corrosion to proceed. 304L teardrop coupons were found to corrode only by pitting with a similar oxide/salt mixture as used in Series 1 testing but with a lower water loading of 0.2 wt%, which resulted in an initial relative humidity of 35-38%. These tests ran twice as long as those for Series 1 testing. The exposure condition was also found to impact the corrosion with salt-exposed surfaces showing lower corrosion resistance. Additional analyses of the Series 2 coupons are recommended especially for determining if cracks emanate from the bottom of pits. Data generated under the 2009 3013 corrosion test plan, as was presented here, increased the understanding of the corrosion process within a sealed 3013 container. Along with the corrosion data from destructive evaluations of 3013 containers, the inner can closure weld region (ICCWR) has been identified as the most vulnerable area of the inner can where corrosion may lead to corrosive species leaking to the interior surface of the outer container, thereby jeopardizing the integrity of the 3013 container. A new corrosion plan has been designed that will characterize the corrosion at the ICCWR of 3013 DEs as well as parameters affecting this corrosion.

3013 plutonium storage, stress corrosion cracking,↗

Sub-kilometer rampart craters in the equatorial region of Mars: Possible implications for the state and distribution of regolith H2O

It was long suspected that Martian rampart crater ejecta morphology originates from an impact into a water or ice-rich crust. If the water-impact hypothesis is correct, then the occurrence of rampart craters at all latitudes, elevations, and in all types of terrain, implies that the distribution of regolith H2O on Mars is global. To test this hypothesis, the occurrence of rampart craters was examined at three locations within the latitude band of + or - 30 degrees (specifically, within the ridged plains unit covered by MC-18). The analysis indicates that while few in number, rampart craters with diameters smaller than 3 km are indeed present at several locations withing the equatorial region of Mars. This finding appears to have significant implications for the inferred state and distribution of subsurface H2O. A more comprehensive analysis of the occurrence of sub-kilometer rampart craters is currently underway.

Clifford, Stephen M.↗

Development of an LS-DYNA Model of an ATR42-300 Aircraft for Crash Simulation

This paper describes the development of an LS-DYNA simulation of a vertical drop test of an ATR42-300 twin-turboprop high-wing commuter-class airplane. A 30-ft/s drop test of this aircraft was performed onto a concrete impact surface at the FAA Technical Center on July 30, 2003. The purpose of the test was to evaluate the structural response of a commuter-class aircraft when subjected to a severe, but survivable, impact. The aircraft was configured with crew and passenger seats, anthropomorphic test dummies, forward and aft luggage, instrumentation, and onboard data acquisition systems. The wings were filled with approximately 8,700 lb. of water to represent the fuel and the aircraft weighed a total of 33,200 lb. The model, which consisted of 57,643 nodes and 62,979 elements, was developed from direct measurements of the airframe geometry, over a period of approximately 8 months. The seats, dummies, luggage, fuel, and other ballast were represented using concentrated masses. Comparisons were made of the structural deformation and failure behavior of the airframe, as well as selected acceleration time history responses.

Jackson, Karen E.↗

Methane hydrate distribution from prolonged and repeated formation in natural and compacted sand samples: X-ray CT observations

To study physical properties of methane gas hydrate-bearing sediments, it is necessary to synthesize laboratory samples due to the limited availability of cores from natural deposits. X-ray computed tomography (CT) and other observations have shown gas hydrate to occur in a number of morphologies over a variety of sediment types. To aid in understanding formation and growth patterns of hydrate in sediments, methane hydrate was repeatedly formed in laboratory-packed sand samples and in a natural sediment core from the Mount Elbert Stratigraphic Test Well. CT scanning was performed during hydrate formation and decomposition steps, and periodically while the hydrate samples remained under stable conditions for up to 60 days. The investigation revealed the impact of water saturation on location and morphology of hydrate in both laboratory and natural sediments during repeated hydrate formations. Significant redistribution of hydrate and water in the samples was observed over both the short and long term.

03 NATURAL GAS↗

Come Hell or High-Water: Challenges for Adapting Pacific Northwest Water Law

The Pacific Northwest region of the United States has been recognized as a leader in crafting water laws that work to balance human needs and ecological considerations. However, this region is experiencing changing dynamics that test the strength of existing water policies and laws. Such dynamics include increasing populations, new and exempt uses, quantification of tribal treaty rights, species protection, renegotiation of the Columbia River Treaty, and the impacts of a changing climate. Together, these dynamics are stressing the legal framework, which remains vital to ensuring sustainable water supplies now and into the future. Here, the history behind water resources management in Oregon, Washington, Idaho, and Montana provides the foundation for the laws in place today. Although all four states share regulatory features, nuances specific to each state have tremendously affected their governance structures and ability to adapt to changing dynamics. Although a challenge to meet these changing dynamics, collaborative efforts offer creative opportunities for meeting current and future needs.

99 GENERAL AND MISCELLANEOUS↗

Assessing Tsunami Vulnerabilities of Geographies with Shallow Water Equations

Tsunami preparedness is crucial for saving human lives in case of disasters that involve massive water movement. In this work, we develop a framework for visual assessment of tsunami preparedness of geographies. Shallow water equations (also called Saint Venant equations) are a set of hyperbolic partial differential equations that are derived by depth-integrating the Navier-Stokes equations and provide a great abstraction of water masses that have lower depths compared to their free surface area. Our specific contribution in this study is to use Microsoft's XNA Game Studio to import underwater and shore line geographies, create different tsunami scenarios, and visualize the propagation of the waves and their impact on the shore line geography. Most importantly, we utilized the computational power of graphical processing units (GPUs) as HLSL based shader files and delegated all of the heavy computations to the GPU. Finally, we also conducted a validation study, in which we have tested our model against a controlled shallow water experiment. We believe that such a framework with an easy to use interface that is based on readily available software libraries, which are widely available and easily distributable, would encourage not only researchers, but also educators to showcase ideas.

Aras, Rifat↗

An epidermal equivalent assay for identification and ranking potency of contact sensitizers

The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low water solubility or stability. A protocol was developed using different 3D-epidermal models including in house VUMC model, epiCS® (previously EST1000™), MatTek EpiDerm™ and SkinEthic™ RHE and also the impact of different vehicles (acetone:olive oil 4:1, 1% DMSO, ethanol, water) was investigated. Following topical exposure for 24 h to 17 contact allergens and 13 non-sensitizers a robust increase in IL-18 release was observed only after exposure to contact allergens. A putative prediction model is proposed from data obtained from two laboratories yielding 95% accuracy. Correlating the in vitro EE sensitizer potency data, which assesses the chemical concentration which results in 50% cytotoxicity (EE-EC{sub 50}) with human and animal data showed a superior correlation with human DSA{sub 05} (μg/cm{sup 2}) data (Spearman r = 0.8500; P value (two-tailed) = 0.0061) compared to LLNA data (Spearman r = 0.5968; P value (two-tailed) = 0.0542). DSA{sub 05} = induction dose per skin area that produces a positive response in 5% of the tested population Also a good correlation was observed for release of IL-18 (SI-2) into culture supernatants with human DSA{sub 05} data (Spearman r = 0.8333; P value (two-tailed) = 0.0154). This easily transferable human in vitro assay appears to be very promising, but additional testing of a larger chemical set with the different EE models is required to fully evaluate the utility of this assay and to establish a definitive prediction model. - Highlights: • A potential epidermal equivalent assay to label and classify sensitizers • Il-18 release distinguishes sensitizers from non sensitizers • IL-18 release can rank sensitizer potency • EC50 (chemical concentration causing 50% decrease in cell viability) ranks potency • In vitro: human DSA{sub 05} correlation is better than in vitro: LLNA correlation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware (Fact Sheet)

Insight Homes constructed two houses in Rehoboth Beach, Delaware, with identical floor plans and thermal envelopes but different heating and domestic hot water (DHW) systems. Each house is 1,715-ft 2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning (HVAC) systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit with supplemental heat provided by the DHW heater (a combined DHW and hydronic heating system, where the hydronic heating element is in the air handler). Both houses were occupied during the test period. Results indicate that efficiency of the two heating systems was not significantly different. Three issues dominate these results; lower system design performance resulting from the indoor refrigerant coil selected for the standard house, an incorrectly functioning defrost cycle in the standard house, and the low resolution of the natural gas monitoring equipment. The thermal comfort of both houses fell outside the ASHRAE Standard 55 heating range but was within the ACCA room-to-room temperature range when compared to the thermostat temperature. The monitored DHW draw schedules were input into EnergyPlus to evaluate the efficiency of the tankless hot water heater model using the two monitored profiles and the Building America House Simulation Protocols. The results indicate that the simulation is not significantly impacted by the draw profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗