Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Optimizing Transportation Networks for E-Waste Reverse Logistics: A Multi-Modal Cost Allocation and Pricing Strategy

The exponential growth of electronic waste (e-waste) poses critical challenges for sustainable reverse logistics and transportation network optimization. This study develops a dual-channel transportation framework for e-waste logistics that integrates dynamic freight pricing, cost allocation mechanisms, and game-theoretic coordination. The model captures interactions between centralized hubs and distributed processing networks, accounting for freight rate elasticity, volume allocation, and capacity constraints. Using Stackelberg game theory and cost-sharing strategies, the framework optimizes transportation efficiency and profit distribution across logistics channels. Numerical simulations show that the dual-channel structure increases centralized hub profit by 226.8% compared to baseline single-channel operations, while boosting total transported volume by 1.2% and nearly doubling freight collector profit under cost-sharing. Scenario analyses across regional infrastructures reveal that network density, policy incentives, and logistics costs shape routing efficiency and profit allocation. These findings suggest that coordinated strategies combining dynamic pricing, targeted infrastructure investment, and strategic cost allocation are needed to design efficient, resilient, and regionally adaptable e-waste transportation systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Retrospective review of Contura HDR breast cases to improve our standardized procedure

To retrospectively review our first 20 Contura high dose rate breast cases to improve and refine our standardized procedure and checklists. We prepared in advance checklists for all steps, developed an in-house Excel spreadsheet for second checking the plan, and generated a procedure for efficient contouring and a set of optimization constraints to meet the dose volume histogram criteria. Templates were created in our treatment planning system for structures, isodose levels, optimization constraints, and plan report. This study reviews our first 20 high dose rate Contura breast treatment plans. We followed our standardized procedure for contouring, planning, and second checking. The established dose volume histogram criteria were successfully met for all plans. For the cases studied here, the balloon-skin and balloon-ribs distances ranged between 5 and 43 mm and 1 and 33 mm, respectively; air{sub s}eroma volume/PTV{sub E}val volume≤5.5% (allowed≤10%); asymmetry<1.2 mm (goal≤2 mm); PTV{sub E}val V90%≥97.6%; PTV{sub E}val V95%≥94.9%; skin max dose≤98%Rx; ribs max dose≤137%Rx; V150%≤29.8 cc; V200%≤7.8 cc; the total dwell time range was 225.4 to 401.9 seconds; and the second check agreement was within 3%. Based on this analysis, more appropriate ranges for the total dwell time and balloon diameter tolerance were found. Three major problems were encountered: balloon migration toward the skin for small balloon-to-skin distances, lumen obstruction, and length change for the flexible balloon. Solutions were found for these issues and our standardized procedure and checklists were updated accordingly. Based on our review of these cases, the use of checklists resulted in consistent results, indicating good coverage for the target without sacrificing the critical structures. This review helped us to refine our standardized procedure and update our checklists.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconfirmation of frit 803 based on the January 2016 sludge batch 9 reprojection

On January 11, 2016, Savannah River Remediation (SRR) provided the Savannah River National Laboratory (SRNL) with a Sludge Batch 9 (SB9) reprojection that was developed from the analyzed composition of a Tank 51 sample. This sample was collected after field washing had been completed in Tank 51 to support the alternate reductant task. Based on this reprojection, Frit 803 is still a viable option for the processing of SB9 under sludge-only operations and coupled (Actinide Removal Process (ARP) product with and without monosodium titanate (MST)) operations. The maximum projected volumes of ARP product that can be transferred from the Precipitate Reactor Feed Tank (PRFT) per Sludge Receipt and Adjustment Tank (SRAT) batch and the resulting Na 2 O concentrations in the SRAT for coupled operations were determined. The Na 2 O concentrations in the SRAT resulting from the maximum projected ARP product transfer volumes are consistent with those from the previous assessments that were based on the August 2015 projections. Regardless of the presence or absence of MST in the ARP product, the contribution of Na 2 O to the resulting glass will be similar at the same waste loading (WL). These projected volumes of ARP product are not anticipated to be an issue for SB9. The actual transfer volumes from the PRFT to the SRAT are determined based upon the analyzed Na 2 O concentrations in the PRFT samples, which has resulted in larger transfer volumes than those allowed by the projections for Sludge Batch 8 (SB8). An operating window of 32-40% WL around the nominal WL of 36% is achievable for both sludge-only and coupled operations; however, each of the glass systems studied does become limited by waste form affecting constraints (durability) at higher volumes of ARP product and WLs of 41-42%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations for Developing Space Suit Integrated Food Systems and Delivering Nutrition Before, During, and After Lunar EVA

The concept of providing hydration and nutrition during extravehicular activity (EVA) is nearly as old as the space program itself. Astronauts currently have access to 32 ounces of water through a disposable in-suit drink bag (DIDB) while they are confined to their space suit. During the Apollo program, methods for providing food/nutrition to crewmembers in space suits were included as contingency solutions (1) but were eventually abandoned. The main reasons that provision of in-suit nutrition beyond water was discontinued after Apollo were the complicated engineering requirements, the additional mass and volume that was required for the applicable food formulations, hardware needed for a suit-specialized food system, and because the perceived need for in-suit nutrition during EVAs was not sufficient during the Space Shuttle and the International Space Station (ISS) eras. A custom-made 165-kcal fruit bar was fitted into the EVA suit during the Space Shuttle program, but crewmembers rarely consumed it during the EVA and rather chose to consume it before or after suited activities (2). Since 2011, between 4 and 13 EVAs have been conducted from the ISS each year, with durations ranging from 1:32 to 8:17 hours (https://www.nasa.gov/mission_pages/station/spacewalks ). It has been acceptable for the crewmembers to schedule food intake around these relatively infrequent suited activities. Because upcoming Artemis missions will include nominal 8-hour lunar exploration EVAs that are expected to increase in frequency to several (4 to 5) sorties per week (3), the desire for an in-suit nutrition system has increased. In preparation for these missions, requirements to provide in-suit nutrition has been outlined in the most recent NASA Human Spaceflight Standards documents (4). Establishing general recommendations for in-suit nutrition systems precedes the selection of a lunar EVA pressure suit system. The current document is intended to define the rationale for nutrition to support EVA (whether in-suit or from the pantry in the habitat), document the requirements, constraints, and crewmember preferences, and recommend necessary next steps for developing an in-suit EVA nutrition system. Assessments presented in this report include a review of commercial off-the-shelf (COTS) food products as potential in-suit formulations, a comparison of conceptual designs for delivering nutrition to a crewmember while confined to a space suit, an evaluation of space suit volume constraints for the placement of in-suit nutrition systems, and feedback from astronauts regarding preferences for nutrition support during EVA. Based on these assessments, recommendations were formulated that can be used to help develop a method to deliver nutrition safely and acceptably to a crewmember while they are confined to a space suit for an EVA duration of up to 8 hours, and a total time in the suit of up to 12 hours.

space suit↗

Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality

Purpose: To investigate the effect of monitor unit (MU) constraints on the dose distribution created by intensity modulated proton therapy (IMPT) treatment planning using single-field optimization (SFO). Methods: Ninety-four energies between 72.5 and 221.8 MeV are available for scanning beam IMPT delivery at our institution. The minimum and maximum MUs for delivering each pencil beam (spot) are 0.005 and 0.04, respectively. These MU constraints are not considered during optimization by the treatment planning system; spots are converted to deliverable MUs during postprocessing. Treatment plans for delivering uniform doses to rectangular volumes with and without MU constraints were generated for different target doses, spot spacings, spread-out Bragg peak (SOBP) widths, and ranges in a homogeneous phantom. Four prostate cancer patients were planned with and without MU constraints using different spot spacings. Rounding errors were analyzed using an in-house software tool. Results: From the phantom study, the authors have found that both the number of spots that have rounding errors and the magnitude of the distortion of the dose distribution from the ideally optimized distribution increases as the field dose, spot spacing, and range decrease and as the SOBP width increases. From our study of patient plans, it is clear that as the spot spacing decreases the rounding error increases, and the dose coverage of the target volume becomes unacceptable for very small spot spacings. Conclusions: Constraints on deliverable MU for each spot could create a significant distortion from the ideally optimized dose distributions for IMPT fields using SFO. To eliminate this problem, the treatment planning system should incorporate the MU constraints in the optimization process and the delivery system should reliably delivery smaller minimum MUs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Highly Miniaturized Inertial Grade Gyroscope for Space Applications

The evolution of inertial grade gyroscopes for space applications represents well over 50 years of technology development and an investment of hundreds of millions of dollars. The workhorse product which represents the current state-of-the art for commercially available high performance devices is the Litton-Hemishperical Resonator Gyro (HRG) Inertial Measurement Unit (IMU). This product has a performance figure of merit of 0.003 deg/hr bias drift, a volume of 567 cubic inches, weighs 19 pounds, draws about 30 watts and costs over $1 million each. Clearly devices of this magnitude are not conducive to the minimized mass, volume, power, and cost constraints of outer planet missions. An approach to breaking these potential barriers is the use of Microelectromechanical Systems (MEMS) based inertial devices. Although substantially reduced in size, mass power and cost, this approach has produced devices in the tactical performance range of greater than 1 deg/hour bias drift. This level of performance satisfies the preponderance of high market volume requirements such as automotive and tactical munitions but does not meet the limited market quantity requirements for the high precision space based market. Because of the very limited size of the space based market, there is little economic incentive for commercial fabricators of tactical grade devices to address the necessary performance improvements. The Jet Propulsion Laboratory (JPL) in conjunction with Boeing Space Systems (BSS) is addressing this void to satisfy our mutual requirements in this area. The project objective to is to achieve 0.01 deg/hr performance in an IMU which is less than 10 cubic inches in volume, weighs less than 0.5 pounds, draws less than 1 watt and is available in volume production for less than $2500. Reductions of this magnitude will be mission enabling capabilities for a variety of anticipated outer planet mission attributes such as autonomous control and docking, formation flying and robotic outposts. The improved performance will be realized using improved relative precision fabrication, enhanced vibratory drive and sense designs, and statistical data analysis.

Wiberg, D. V.↗

SU-E-T-417: The Impact of Normal Tissue Constraints On PTV Dose Homogeneity for Intensity Modulated Radiotherapy (IMRT), Volume Modulated Arc Therapy (VMAT) and Tomotherapy

Purpose: Complex intensity modulated arc therapy tends to spread low dose to normal tissue(NT)regions to obtain improved target conformity and homogeneity and OAR sparing.This work evaluates the trade-offs between PTV homogeneity and reduction of the maximum dose(Dmax)spread to NT while planning of IMRT,VMAT and Tomotherapy. Methods: Ten prostate patients,previously planned with step-and-shoot IMRT,were selected.To fairly evaluate how PTV homogeneity was affected by NT Dmax constraints,original IMRT DVH objectives for PTV and OARs(femoral heads,and rectal and bladder wall)applied to 2 VMAT plans in Pinnacle(V9.0), and Tomotherapy(V4.2).The only constraint difference was the NT which was defined as body contours excluding targets,OARs and dose rings.NT Dmax constraint for 1st VMAT was set to the prescription dose(Dp).For 2nd VMAT(VMAT-NT)and Tomotherapy,it was set to the Dmax achieved in IMRT(~70-80% of Dp).All NT constraints were set to the lowest priority.Three common homogeneity indices(HI),RTOG-HI=Dmax/Dp,moderated-HI=D95%/D5% and complex-HI=(D2%-D98%)/Dp*100 were calculated. Results: All modalities with similar dosimetric endpoints for PTV and OARs.The complex-HI shows the most variability of indices,with average values of 5.9,4.9,9.3 and 6.1 for IMRT,VMAT,VMAT-NT and Tomotherapy,respectively.VMAT provided the best PTV homogeneity without compromising any OAR/NT sparing.Both VMAT-NT and Tomotherapy,planned with more restrictive NT constraints,showed reduced homogeneity,with VMAT-NT showing the worst homogeneity(P<0.0001)for all HI.Tomotherapy gave the lowest NT Dmax,with slightly decreased homogeneity compared to VMAT. Finally, there was no significant difference in NT Dmax or Dmean between VMAT and VMAT-NT. Conclusion: PTV HI is highly dependent on permitted NT constraints. Results demonstrated that VMAT-NT with more restrictive NT constraints does not reduce Dmax NT,but significantly receives higher Dmax and worse target homogeneity.Therefore, it is critical that planners do not use too restrictive NT constraints during VMAT optimization.Tomotherapy plan was not as sensitive to NT constraints,however,care shall be taken to ensure NT is not pushed too hard.These results are relevant for clinical practice.The biological effect of higher Dmax and increased target heterogeneity needs further study.

60 APPLIED LIFE SCIENCES↗

Lung Size and the Risk of Radiation Pneumonitis

Purpose: The purpose of this study was to identify patient populations treated for non-small cell lung cancer (NSCLC) who may be more at risk of radiation pneumonitis. Methods and Materials: A total of 579 patients receiving fractionated 3D conformal or intensity modulated radiation therapy (IMRT) for NSCLC were included in the study. Statistical analysis was performed to search for cohorts of patients with higher incidences of radiation pneumonitis. In addition to conventional risk factors, total and spared lung volumes were analyzed. The Lyman-Kutcher-Burman (LKB) and cure models were then used to fit the incidence of radiation pneumonitis as a function of lung dose and other factors. Results: Total lung volumes with a sparing of less than 1854 cc at 40 Gy were associated with a significantly higher incidence of radiation pneumonitis at 6 months (38% vs 12% for patients with larger volumes, P<.001). This patient cohort was overwhelmingly female and represented 22% of the total female population of patients and nearly 30% of the cases of radiation pneumonitis. An LKB fit to normal tissue complication probability (NTCP) including volume as a dose modifying factor resulted in a dose that results in a 50% probability of complication for the smaller spared volume cohort that was 9 Gy lower than the fit to all mean lung dose data and improved the ability to predict radiation pneumonitis (P<.001). Using an effective dose parameter of n=0.42 instead of mean lung dose further improved the LKB fit. Fits to the data using the cure model produced similar results. Conclusions: Spared lung volume should be considered when treating NSCLC patients. Separate dose constraints based on smaller spared lung volume should be considered. Smaller spared lung volume patients should be followed closely for signs of radiation pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conceptual Design Optimization of an Augmented Stability Aircraft Incorporating Dynamic Response Performance Constraints

This research focused on incorporating stability and control into a multidisciplinary de- sign optimization on a Boeing 737-class advanced concept called the D8.2b. A new method of evaluating the aircraft handling performance using quantitative evaluation of the sys- tem to disturbances, including perturbations, continuous turbulence, and discrete gusts, is presented. A multidisciplinary design optimization was performed using the D8.2b transport air- craft concept. The con guration was optimized for minimum fuel burn using a design range of 3,000 nautical miles. Optimization cases were run using xed tail volume coecients, static trim constraints, and static trim and dynamic response constraints. A Cessna 182T model was used to test the various dynamic analysis components, ensuring the analysis was behaving as expected. Results of the optimizations show that including stability and con- trol in the design process drastically alters the optimal design, indicating that stability and control should be included in conceptual design to avoid system level penalties later in the design process.

Welstead, Jason↗

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

Adaptive/Nonadaptive Proton Radiation Planning and Outcomes in a Phase II Trial for Locally Advanced Non-small Cell Lung Cancer

Purpose: To analyze dosimetric variables and outcomes after adaptive replanning of radiation therapy during concurrent high-dose protons and chemotherapy for locally advanced non-small cell lung cancer (NSCLC). Methods and Materials: Nine of 44 patients with stage III NSCLC in a prospective phase II trial of concurrent paclitaxel/carboplatin with proton radiation [74 Gy(RBE) in 37 fractions] had modifications to their original treatment plans after re-evaluation revealed changes that would compromise coverage of the target volume or violate dose constraints; plans for the other 35 patients were not changed. We compared patients with adaptive plans with those with nonadaptive plans in terms of dosimetry and outcomes. Results: At a median follow-up of 21.2 months (median overall survival, 29.6 months), no differences were found in local, regional, or distant failure or overall survival between groups. Adaptive planning was used more often for large tumors that shrank to a greater extent (median, 107.1 cm{sup 3} adaptive and 86.4 cm{sup 3} nonadaptive; median changes in volume, 25.3% adaptive and 1.2% nonadaptive; P<.01). The median number of fractions delivered using adaptive planning was 13 (range, 4-22). Adaptive planning generally improved sparing of the esophagus (median absolute decrease in V{sub 70}, 1.8%; range, 0%-22.9%) and spinal cord (median absolute change in maximum dose, 3.7 Gy; range, 0-13.8 Gy). Without adaptive replanning, target coverage would have been compromised in 2 cases (57% and 82% coverage without adaptation vs 100% for both with adaptation); neither patient experienced local failure. Radiation-related grade 3 toxicity rates were similar between groups. Conclusions: Adaptive planning can reduce normal tissue doses and prevent target misses, particularly for patients with large tumors that shrink substantially during therapy. Adaptive plans seem to have acceptable toxicity and achieve similar local, regional, and distant control and overall survival, even in patients with larger tumors, vs nonadaptive plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Meta Biome: a multiscale model integrating agent-based and metabolic networks to reveal spatial regulation in gut mucosal microbial communities

ABSTRACT Mucosal microbial communities (MMCs) are complex ecosystems near the mucosal layers of the gut essential for maintaining health and modulating disease states. Despite advances in high-throughput omics technologies, current methodologies struggle to capture the dynamic metabolic interactions and spatiotemporal variations within MMCs. In this work, we presentMetaBiome, a multiscale model integrating agent-based modeling (ABM), finite volume methods, and constraint-based models to explore the metabolic interactions within these communities. Integrating ABM allows for the detailed representation of individual microbial agents each governed by rules that dictate cell growth, division, and interactions with their surroundings. Through a layered approach—encompassing microenvironmental conditions, agent information, and metabolic pathways—we simulated different communities to showcase the potential of the model. Using ourin-silicoplatform, we explored the dynamics and spatiotemporal patterns of MMCs in the proximal small intestine and the cecum, simulating the physiological conditions of the two gut regions. Our findings revealed how specific microbes adapt their metabolic processes based on substrate availability and local environmental conditions, shedding light on spatial metabolite regulation and informing targeted therapies for localized gut diseases.MetaBiome provides a detailed representation of microbial agents and their interactions, surpassing the limitations of traditional grid-based systems. This work marks a significant advancement in microbial ecology, as it offers new insights into predicting and analyzing microbial communities. IMPORTANCE Our study presents a novel multiscale model that combines agent-based modeling, finite volume methods, and genome-scale metabolic models to simulate the complex dynamics of mucosal microbial communities in the gut. This integrated approach allows us to capture spatial and temporal variations in microbial interactions and metabolism that are difficult to study experimentally. Key findings from our model include the following: (i) prediction of metabolic cross-feeding and spatial organization in multi-species communities, (ii) insights into how oxygen gradients and nutrient availability shape community composition in different gut regions, and (iii) identification of spatiallyregulated metabolic pathways and enzymes inE. coli. We believe this work represents a significant advance in computational modeling of microbial communities and provides new insights into the spatial regulation of gut microbiome metabolism. The multiscale modeling approach we have developed could be broadly applicable for studying other complex microbial ecosystems.

Microbiology↗

Measurements of the E-mode polarization and temperature-E-mode correlation of the CMB from SPT-3G 2018 data

We present measurements of the E -mode ( E E ) polarization power spectrum and temperature- E -mode ( T E ) cross-power spectrum of the cosmic microwave background using data collected by SPT-3G, the latest instrument installed on the South Pole Telescope. This analysis uses observations of a 1500 deg 2 region at 95, 150, and 220 GHz taken over a four-month period in 2018. We report binned values of the E E and T E power spectra over the angular multipole range 300 ≤ ℓ < 3000 , using the multifrequency data to construct six semi-independent estimates of each power spectrum and their minimum-variance combination. These measurements improve upon the previous results of SPTpol across the multipole ranges 300 ≤ ℓ ≤ 1400 for E E and 300 ≤ ℓ ≤ 1700 for T E , resulting in constraints on cosmological parameters comparable to those from other current leading ground-based experiments. We find that the SPT-3G data set is well fit by a Λ CDM cosmological model with parameter constraints consistent with those from Planck and SPTpol data. From SPT-3G data alone, we find H 0 = 68.8 ± 1.5 km s - 1 Mpc - 1 and σ 8 = 0.789 ± 0.016 , with a gravitational lensing amplitude consistent with the Λ CDM prediction ( A L = 0.98 ± 0.12 ). We combine the SPT-3G and the Planck data sets and obtain joint constraints on the Λ CDM model. The volume of the 68% confidence region in six-dimensional Λ CDM parameter space is reduced by a factor of 1.5 compared to Planck-only constraints, with no significant shifts in central values. We note that the results presented here are obtained from data collected during just half of a typical observing season with only part of the focal plane operable, and that the active detector count has since nearly doubled for observations made with SPT-3G after 2018.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular Structures of Fluid Phase Phosphatidylglycerol Bilayers as Determined by Small Angle Neutron and X-ray Scattering

We have determined the molecular structures of commonly used phosphatidylglycerols (PGs) in the commonly accepted biologically relevant fluid phase. This was done by simultaneously analyzing small-angle neutron and X-ray scattering data, with the constraint of a measured volume per lipid. We report the temperature dependence of bilayer parameters obtained using the one dimensional scattering density profile model derived from molecular dynamics simulations, including the area per lipid, the overall bilayer thickness, as well as other intrabilayer parameters (e.g., hydrocarbon thickness). Lipid areas are found to be larger than their phosphatidylcholine (PC) counterparts, a result likely due to repulsive electrostatic interactions taking place between the charged PG headgroups even in the presence of Na+ counterions. In general, PG and PC bilayers show a similar response to changes in temperature and chain length, but differ in their response to chain unsaturation. For example, compared to their PC counterparts, the inclusion of a double bond in PG lipids results in a smaller incremental change in lipid area and bilayer thickness. However, the extrapolated lipid area of saturated PG lipids at infinite chain length is found to be similar to that of PCs, an indication of the glycerol-carbonyl backbone's pivotal role in influencing the lipid-water interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical-mechanical coupling failure mechanism of composite cathode in all-solid-state batteries

Composite cathode composed of active particles and solid electrolytes (SEs) can considerably enlarge the particle-SE contact areas and achieve high areal loadings in all-solid-state batteries (ASSBs). However, the challenging interfacial instability and particle damage problems remain unsolved. Herein, we establish a 3D electrochemical-mechanical coupled model to investigate the underlying failure mechanism by considering the governing electrochemical and physics processes. Micro-scale heterogeneous primary particles with random crystallographic orientation and size inside the LiNi 1/3 Co 1/3 Mn 1/3 O 2 (NCM111) secondary particle of the model result in the anisotropic Li diffusion and volume variation within the secondary particle, leading to significant nonuniformity of the Li concentration, and GPa-level stress distributions at primary particle boundaries, and finally causing the particle internal cracks. The particle volume shrinkage under the constraint of stiff Li 7 La 3 Zr 2 O 12 (LLZO) SE triggers the interface debonding (gap>50 nm) with increased interfacial impedance to degrade cell capacity. Higher C-rates result in larger residual stress (~100 MPa)/strain/debonding gap at dis-charging end, more likely to deteriorate the cell performance. Increasing the interfacial strength between the particle and SE can suppress the interface debonding but induces high stress (up to 10 GPa). In conclusion, results reveal the underlying mechanism of the electrochemical-mechanical coupling failure mechanism for composite cathode and provide promising guidance on the further improvement of a more robust composite cathode for ASSBs.

25 ENERGY STORAGE↗

Supercritical cryo-compressed hydrogen storage for fuel cell electric buses

Liquid hydrogen (LH 2 ) truck delivery and storage at dispensing sites is likely to play an important role in an emerging H 2 infrastructure. Here, we analyzed the performance of single phase, supercritical, on-board cryo-compressed hydrogen storage (CcH 2 ) with commercially-available LH 2 pump enabled single-flow refueling for application to fuel cell electric buses (FCEB). We conducted finite-element stress analyses of Type 3 CcH 2 tanks using ABAQUS for carbon fiber requirement and Fe-Safe for fatigue life. The results from these analyses indicate that, from the standpoint of weight, volume and cost, 2-mm 316 stainless steel liner is preferred to aluminium 6061 alloy in meeting the required 15,000 charge-discharge cycles for 350–700 bar storage pressures. Compared to the Type 3, 350 bar, ambient-temperature H 2 storage systems in current demonstration FCEBs, 500-bar CcH 2 storage system is projected to achieve 91% improvement in gravimetric capacity, 175% improvement in volumetric capacity, 46% reduction in carbon fiber composite mass, and 21% lower system cost, while exceeding >7 day loss-free dormancy with initially 85%-full H 2 tank.

08 HYDROGEN↗

Quality Assurance Peer Review Chart Rounds in 2011: A Survey of Academic Institutions in the United States

Purpose: In light of concerns regarding the quality of radiation treatment delivery, we surveyed the practice of quality assurance peer review chart rounds at American academic institutions. Methods and Materials: An anonymous web-based survey was sent to the chief resident of each institution across the United States. Results: The response rate was 80% (57/71). The median amount of time spent per patient was 2.7 minutes (range, 0.6-14.4). The mean attendance by senior physicians and residents was 73% and 93%, respectively. A physicist was consistently present at peer review rounds in 66% of departments. There was a close association between attendance by senior physicians and departmental organization: in departments with protected time policies, good attendance was 81% vs. 31% without protected time (p = 0.001), and in departments that documented attendance, attending presence was 69% vs. 29% in departments without documentation (p < 0.05). More than 80% of institutions peer review all external beam therapy courses; however, rates were much lower for other modalities (radiosurgery 58%, brachytherapy 40%-47%). Patient history, chart documentation, and dose prescription were always peer reviewed in >75% of institutions, whereas dosimetric details (beams, wedges), isodose coverage, intensity-modulated radiation therapy constraints, and dose-volume histograms were always peer reviewed in 63%, 59%, 42%, and 50% of cases, respectively. Chart rounds led to both minor (defined as a small multileaf collimator change/repeated port film) and major (change to dose prescription or replan with dosimetry) treatment changes. Whereas at the majority of institutions changes were rare (<10% of cases), 39% and 11% of institutions reported that minor and major changes, respectively, were made to more than 10% of cases. Conclusion: The implementation of peer review chart rounds seems inconsistent across American academic institutions. Brachytherapy and radiosurgical procedures are rarely reviewed. Attendance by senior physicians is variable, but it improves when scheduling clashes are avoided. The potential effect of a more thorough quality assurance peer review on patient outcomes is not known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robust and conductive two-dimensional metal-organic frameworks with exceptionally high volumetric and areal capacitance

For miniaturized capacitive energy storage, volumetric and areal capacitances are more important metrics than gravimetric ones because of the constraints imposed by device volume and chip area. Typically used in commercial supercapacitors, porous carbons, although they provide a stable and reliable performance, lack volumetric performance because of their inherently low density and moderate capacitances. In this paper, we report a high-performing electrode based on conductive hexaaminobenzene (HAB)-derived two-dimensional metal-organic frameworks (MOFs). In addition to possessing a high packing density and hierarchical porous structure, these MOFs also exhibit excellent chemical stability in both acidic and basic aqueous solutions, which is in sharp contrast to conventional MOFs. Submillimetre-thick pellets of HAB MOFs showed high volumetric capacitances up to 760 F cm -3 and high areal capacitances over 20 F cm -2 . Furthermore, the HAB MOF electrodes exhibited highly reversible redox behaviours and good cycling stability with a capacitance retention of 90% after 12,000 cycles. In conclusion, these promising results demonstrate the potential of using redox-active conductive MOFs in energy-storage applications.

25 ENERGY STORAGE↗