Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Variable Grid Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

A coupled multipoint stress–multipoint flux mixed finite element method for the Biot system of poroelasticity

In this work, we present a mixed finite element method for a five-field formulation of the Biot system of poroelasticity that reduces to a cell-centered pressure–displacement system on simplicial and quadrilateral grids. A mixed stress–displacement–rotation formulation for elasticity with weak stress symmetry is coupled with a mixed velocity–pressure Darcy formulation. The spatial discretization is based on combining the multipoint stress mixed finite element (MSMFE) method for elasticity and the multipoint flux mixed finite element (MFMFE) method for Darcy flow. It uses the lowest order Brezzi–Douglas–Marini mixed finite element spaces for the poroelastic stress and Darcy velocity, piecewise constant displacement and pressure, and continuous piecewise linear or bilinear rotation. A vertex quadrature rule is applied to the velocity, stress, and stress–rotation bilinear forms, which block-diagonalizes the corresponding matrices and allows for local velocity, stress, and rotation elimination. This leads to a cell-centered positive-definite system for pressure and displacement at each time step. We perform error analysis for the semidiscrete and fully discrete formulations, establishing first order convergence for all variables in their natural norms. The numerical tests confirm the theoretical convergence rates and illustrate the locking-free property of the method.

42 ENGINEERING↗

Analysis of Differential Financial Impacts of LWR Load-Following Operations. Revision 1

This document reports the application of HERON (Holistic Energy Resource Optimization Network), a newly-developed RAVEN (Risk Analysis Virtual ENvironment) plugin for grid and capacity optimization, to a case study conducted in collaboration with Arizona Public Service (APS). The study is a work in progress; this report presents a description of current models and corresponding results for a particular consideration. APS is anticipating several operational challenges. The first is rapid growth of Variable Renewable Energy (VRE) sources such as wind and solar power providing energy to the grid in the APS service region. This creates challenges for baseload operation of the Palo Verde Generating Station (PVGS), a nuclear power plant co-owned and operated by APS. The second challenge for APS is a change in the cooling water acquisition contract with the Sub Regional Operating Group (SROG). The existing contract is expiring soon, and a renewal is only available for a significantly higher price of water. These two challenges represent a difficulty in maintaining profitability for PVGS as local area demand is highly fluctuant and water prices may increase. Furthermore, excess production at PVGS is currently traded on the Palo Verde energy Hub (PVH), which occasionally offers very low or negative locational marginal prices (LMP) for electricity. This analysis considers the potential benefits of occasional curtailment of PVGS as a method to mitigate unprofitable production hours. Similar to load following, optional daily curtailment would allow APS to elect curtailment of PVGS as low as 70% of its nominal operating level between the hours of 08:00 and 16:00 provided local area demand is met and it is profitable to do so. This document reports a stochastic differential analysis of the Net Present Value (NPV) of PVGS as operated by NPS as a result of optional curtailment operation. To model this differential case, HERON has been designed from previous efforts in this study as a generic tool to accelerate the design and execution of RAVEN workflows for technoeconomic analysis of grid energy systems. HERON leverages both RAVEN and the CashFlow plugin for RAVEN to stochastically explore or optimize a response surface with energy grid system production capacities as inputs and mean NPV as a goal function. HERON performs these evaluations by stochastically sampling market, weather, and demand events using RAVEN’s ARMA reduced-order model capability to generate boundary conditions for dispatch optimization. The algorithm performs the dispatch optimization for each of the synthetic scenarios. For this case, HERON designs workflows to simulate behavior of the PVH, wind, solar, and APS local area demand, and use these synthetic scenarios to stochastically evaluate the differential benefit of optional curtailment for each scenario. While this study finds optional curtailment to be a potential source of revenue, the magnitude of the differential NPV is sufficiently small that it is unlikely a priority for increasing the profitability of PVGS. Further, the differential NPV shrinks throughout the simulated years, suggesting the long-term benefit of such operation given current assumptions is negligible.

14 SOLAR ENERGY↗

Comprehensive assessment of deep reinforcement learning approaches for economic dispatch in nuclear-driven microgrids

As the electrical grid integrates more variable renewable energy sources such as wind and solar, the demand for distributed and flexible systems to address this increased variability becomes critical. Nuclear-driven microgrids provide a promising solution by offering stable generation to complement intermittent renewables, ensuring grid reliability and operating efficiency. This paper proposes a recurrent deep reinforcement learning framework for optimal economic dispatch in a nuclear-powered microgrid integrating renewable energy sources, small modular reactors, battery storage systems, and balance-of-plant dynamics. A three-agent control architecture is developed, where demand and renewable energy agents act as forecasters, and a reinforcement learning-based dispatch agent performs real-time energy allocation. A nonlinear programming formulation is first used to generate an optimal baseline for benchmarking. The proposed dispatch controller, based on Proximal Policy Optimization enhanced with Long Short-Term Memory networks, exploits temporal correlations in system dynamics by taking advantage of the time series used as inputs to improve policy robustness under uncertainty. Comparative analysis against established deep reinforcement learning methods, including Proximal Policy Optimization with a feedforward architecture, Soft Actor-Critic, and Twin Delayed Deep Deterministic Policy Gradient, demonstrates superior performance. Numerical results indicate that the proposed controller achieves a 0.39% cost reduction relative to the nonlinear programming benchmark and outperforms other learning-based methods by generating additional revenue of up to 0.35%. All reinforcement learning controllers compute dispatch actions in less than 0.3 s, resulting in a computational speedup of more than three orders of magnitude over the nonlinear programming baseline. The findings of this paper highlight their applicability for real-time operation and control in nuclear-integrated microgrids under volatile operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Redesigning capacity market to include flexibility via ramp constraints in high-renewable penetrated system

Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Fidelity Active Subspaces for Wind Farm Uncertainty Quantification

Wind plants operate in stochastic environments characterized by complex turbulent flow dynamics and high-dimensional random variables. A key step in uncertainty quantification studies is sensitivity analysis and dimension reduction that can facilitate the development of surrogate models to be used for forward and inverse propagation or optimization under uncertainty. Prior work has shown active subspaces are an effective tool for identifying important directions in the space of stochastic inputs; however, they have only been applied to single-fidelity wind plant models. In this study, we investigate the efficacy of a multi-fidelity active subspace method for analyzing the uncertainty in wind plant power output. The multi-fidelity active subspace estimator offers the promise of increased accuracy in identifying active subspaces as compared to a single-fidelity estimator for the same computational cost, or a reduction in cost for the same accuracy. This makes the study of uncertainty in larger wind plants and with higher fidelity physics tractable. The multi-fidelity active subspace method is applied to gridded and existing wind plant layouts with single and multiple inflow conditions and its performance for surrogate modeling and uncertainty propagation is compared against a single-fidelity active subspace method. This multi-fidelity approach yields substantial computational speedups of 2x - 3.4x across the test cases along with acceptable accuracy in surrogate modeling and computing statistical moments.

active subspace↗

Optimization of a High Pressure Turbine Blade and Sector-Based Annular Rig Design for Supercritical CO2 Power Cycle Representative Testing

Abstract As part of the ongoing research into the design of hardware for zero emission cycles, a first-stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design three-dimensional with objectives of increasing efficiency and decreasing heat load to the blade. Supercritical CO2 property tables are constructed from NIST REFPROP data for the condensable gas simulation in FINE/Turbo. A detailed mesh sensitivity study is performed for a baseline design to identify the proper-grid refinement and efficiently allocate resources for the optimization. Seventy design variables are selected for the initial population generation. Self-organizing maps are then used to focus the design variables on the most important ones affecting the objective functions. The optimization results in approximately 3000 three-dimensional Reynolds Averaged Navier Stokes simulations of different blade shapes with increases in efficiency of up to 0.85% and decreases in heat load of 14%. Families of blade shapes are identified for experimental testing in an annular rig at the Purdue Experimental Turbine Aerothermal Laboratory. A design to adapt the annular cascade for testing optimized geometries is introduced, which features eccentric radius sectors allowing for scaled-up geometries of sCO2 optimized blade profiles to be tested at design cycle representative conditions at high Reynolds numbers in dry air. Analysis into the effects of Reynolds number, working fluid, and geometric relations are presented to prove the efficacy of the test method.

Engineering↗

A simplified regression building thermal modelling method for detached two-floor house in U.S.

The residential building sector accounts for approximately 37% of total U.S. electricity consumption. Within the residential building sector, heating and cooling is the main target for peak load shifting/reduction since it is the largest contributor to peak demand. In fact, the flexibility of residential HVAC loads can provide continuous variation of demand to provide grid services by varying their demand over a baseline. The performance of HVAC load control to provide grid services relies heavily on the accuracy of indoor air temperature or cooling/heating demand predictions and therefore the quality of building model. Besides forward models, popular building models are data-driven models which can be broken down into two categories: gray-box model, e.g. Resistance-Capacitance (RC) model and black-box model. RC model, also called lumped capacitance or network model, which is constituted with electrical analogue pattern with resistance (R) and capacitance (C). In general, RC models require considerable computation burden and long periods of data to train limited number of model coefficients. Black-box models have gained increasing interest due to their capability in analyzing large-scale data and flexibility in practical applications. But, the data-mining based (machine learning algorithms/techniques based) models tend to have invisible model structures which poses a problem when trying to use the model for optimal control or model predictive control of the HVAC system. Hence, there is a continuing need for efficient online system identification techniques, which can provide explicit parameters for the model. Traditional regression models fit well for this specific purpose. This paper presents an innovative way to predict average indoor temperature in separate floors of typical detached residential house. A rolling horizon linear regression model, which includes online adaptive correction component, is proposed to predict the temperature difference between downstairs and upstairs. A RC model is used to predict the overall mean indoor air temperature. Since the adaptive algorithm needs to be implemented online, a less computation-demanding polynomial fitting algorithm is adopted. This kind of fitting problem can be cast as linear regression problem with multiple variables, parameters of which can be efficiently obtained by well-known gradient descent method.The validation is conducted by comparing the predicted results with the results from data-mining based models as well as measured data from a real typical detached two-floor house. The results show that the developed method has satisfactory performance in predicting the building indoor temperature in 1st and 2nd floors.

Cui, Borui↗

Impacts of Spatial Heterogeneity and Temporal Non-Stationarity on Intensity-Duration-Frequency Estimates—A Case Study in a Mountainous California-Nevada Watershed

Changes in extreme precipitation events may require revisions of civil engineering standards to prevent water infrastructures from performing below the designated guidelines. Climate change may invalidate the intensity-duration-frequency (IDF) computation that is based on the assumption of data stationarity. Efforts in evaluating non-stationarity in the annual maxima series are inadequate, mostly due to the lack of long data records and convenient methods for detecting trends in the higher moments. In this study, using downscaled high resolution climate simulations of the historical and future periods under different carbon emission scenarios, we tested two solutions to obtain reliable IDFs under non-stationarity: (1) identify quasi-stationary time windows from the time series of interest to compute the IDF curves using data for the corresponding time windows; (2) introduce a parameter representing the trend in the means of the extreme value distributions. Focusing on a mountainous site, the Walker Watershed, the spatial heterogeneity and variability of IDFs or extremes are evaluated, particularly in terms of the terrain and elevation impacts. We compared observations-based IDFs that use the stationarity assumption with the two approaches that consider non-stationarity. The IDFs directly estimated based on the traditional stationarity assumption may underestimate the 100-year 24-h events by 10% to 60% towards the end of the century at most grids, resulting in significant under-designing of the engineering infrastructure at the study site. Strong spatial heterogeneity and variability in the IDF estimates suggest a preference for using high resolution simulation data for the reliable estimation of exceedance probability over data from sparsely distributed weather stations. Discrepancies among the three IDFs analyses due to non-stationarity are comparable to the spatial variability of the IDFs, underscoring a need to use an ensemble of non-stationary approaches to achieve unbiased and comprehensive IDF estimates.

54 ENVIRONMENTAL SCIENCES↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Modeling of Cloud Microphysics: Can We Do Better?

Representation of cloud microphysics is a key aspect of simulating clouds. From the early days of cloud modeling, numerical models have relied on an Eulerian approach for all cloud and thermodynamic and microphysics variables. Over time the sophistication of microphysics schemes has steadily increased, from simple representations of bulk masses of cloud and rain in each grid cell, to including different ice particle types and bulk hydrometeor concentrations, to complex schemes referred to as bin or spectral schemes that explicitly evolve the hydrometeor size distributions within each model grid cell. As computational resources grow, there is a clear trend toward wider use of bin schemes, including their use as benchmarks to develop and test simplified bulk schemes. We argue that continuing on this path brings fundamental challenges difficult to overcome. The Lagrangian particle-based probabilistic approach is a practical alternative in which the myriad of cloud and precipitation particles present in a natural cloud is represented by a judiciously selected ensemble of point particles called superdroplets or superparticles. Here, the advantages of the Lagrangian particle-based approach when compared to the Eulerian bin methodology are explained, and the prospects of applying the method to more comprehensive cloud simulations—for instance, targeting deep convection or frontal cloud systems—are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How Would the Twenty-First-Century Warming Influence Pacific Decadal Variability and Its Connection to North American Rainfall: Assessment Based on a Revised Procedure for the IPO/PDO

Decadal climate variability of sea surface temperature (SST) over the Pacific Ocean can be characterized by interdecadal Pacific oscillation (IPO) or Pacific decadal oscillation (PDO) based on empirical orthogonal function (EOF) analysis. Although the procedures to derive the IPO and PDO indices differ in their regional focuses and filtering methods to remove interannual variability, the IPO and PDO are highly correlated in time and are often used interchangeably. Studies have shown that the IPO and PDO conjointly (IPO/PDO for conciseness) play a vital role in modulating the pace of global warming. It is less clear, however, how externally forced global warming may, in turn, affect the IPO/PDO. One obstacle to revealing this effect is that the conventional definitions of the IPO/PDO fail to account for the spatial heterogeneity of the background warming trend, which causes the IPO/PDO to be conflated with the warming trend, especially for the twenty-first-century simulation when the forced change is likely to be more dominant. Using a large-ensemble simulation in the Community Earth System Model, version 1 (CESM1), it is shown here that a better practice of detrending prior to EOF analysis is to remove the local and nonlinear trend, defined as the ensemble-mean time series at each grid box (or simply as the quadratic fit of the local time series if such an ensemble is not available). The revised IPO/PDO index is purely indicative of internal decadal variability. In the twenty-first-century warmer climate, the IPO/PDO has a weaker amplitude in space, a higher frequency in time, and a muted impact on global and North American temperature and rainfall.

54 ENVIRONMENTAL SCIENCES↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On the Accuracy of the ALMA Flux Calibration in the Time Domain and across Spectral Windows

A diverse array of science goals requires accurate flux calibration of observations with the Atacama Large Millimeter/submillimeter array (ALMA); however, this goal remains challenging due to the stochastic time-variability of the “grid” quasars ALMA uses for calibration. In this work, we use 343.5 GHz (Band 7) ALMA Atacama Compact Array observations of four bright and stable young stellar objects over seven epochs to independently assess the accuracy of the ALMA flux calibration and to refine the relative calibration across epochs. The use of these four extra calibrators allows us to achieve an unprecedented relative ALMA calibration accuracy of ~3%. On the other hand, when the observatory calibrator catalog is not up to date, the Band 7 data calibrated by the ALMA pipeline may have a flux calibration poorer than the nominal 10%, which can be exacerbated by weather-related phase decorrelation when self-calibration of the science target is either not possible or not attempted. We also uncover a relative flux calibration uncertainty between spectral windows of 0.8%, implying that measuring spectral indices within a single ALMA band is likely highly uncertain. We thus recommend various methods for science goals requiring high flux accuracy and robust calibration, in particular, the observation of additional calibrators combined with a relative calibration strategy, and observation of solar system objects for high absolute accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

CUDA Computation of the Feynman Distribution

In 2006, NVIDIA Corporation introduced the Computer Unified Device Architecture (CUDA) for C, C++, and Fortran programming languages. The CUDA parallel computing platform uses the Graphics Processing Unit (GPU) of NVIDIA graphics card, and it is designed for parallel computations. In these computations, the same algorithms are executed on the data in parallel. The GPU contains many Streaming Multiprocessors (SM) that can independently execute blocks of threads. A thread is a sequence of serial programmed instructions. The SM executes threads in groups of 32 and a group of 32 threads is called warp. The threads within a block can be synchronized and have access to a shared memory that is visible only to them. Conversely, blocks of threads cannot be synchronized and have access only to the global memory of the graphics card. This memory is called device memory and is independent of the host memory controlled by the Central Processing Unit (CPU). A single thread has access to a local memory (register) that is not visible to any other thread. The part of the program that is executed on the graphics card is called kernel. Each thread of the kernel has a unique identification index that is accessible by the in-built variable threadIdx; the latter is a 3-component vector. A threads block can contain up to 1024 threads. Blocks of threads have a unique identification index that is accessible by the in-built variable blockIdx; the latter is a 3-component vector. The in-built variable blockDim contains the number of threads per block; this variable is a 3-component vector. Threads and blocks represent different levels of parallelism; a kernel is executed as a grid of blocks of threads. Figure 1 illustrates a grid of thread blocks for a GPU with 2 SM. A SM can execute multiple blocks of threads in parallel; a block of threads is executed on a single SM. A GPU can execute multiple kernels concurrently. This work has used the Quadro M5000 graphics card with the following technical specifications: - 2048 cores with 861 MHz frequency, - 16 streaming multiprocessors, - 5.2 trillion transistors, - 8.2 Gb device memory, - 64 kb register memory (per thread), - 48 kb shared memory (per block) - 211.6 GB/s memory bandwidth, and - 3.5 GFLOPS floating point performance.

97 MATHEMATICS AND COMPUTING↗

Intra-hour Solar Irradiance Forecast in Multiple Locations using Deep Transfer Learning

In recent years, solar power system installation imposes several challenges on the operations of local and regional power grids due to the inherent variability of ground-level solar irradiance. This work proposes a novel real-time solar forecast methodology for intra-hour solar irradiance based on deep transfer learning from ground-based sky imager for time horizons ranging from 5-15 min. There are three unique aspects of the proposed methodology: (1) a Deep Learning based algorithm development which is modeled as a classification approach rather than a traditional regression approach; (2) the use of the Transfer Learning technique to show generalization capability, robustness, and portability of baseline model in the newly deployed location where availability of enough data for training is typically scarce, and (3) redefinition of point-based irradiation forecast error estimation technique with a window-based one that is more intuitive and user-friendly. The system is developed using multiple years of irradiance and sky image recording in New Jersey and one-year data from Colorado, USA. The method is validated against ground telemetry from these two locations of diverse geographic and climatic conditions. Results show that the forecasting method proposed in this work is robust and highly accurate (8% MAPE error) for multiple locations deployment.

Deep Learning, Convolution Neural Networks, transf↗

A minimally-dissipative low-Mach number solver for complex reacting flows in Open$\mathrm{FOAM}$

Large eddy simulation (LES) has become the de-facto computational tool for modeling complex reacting flows, especially in gas turbine applications. However, readily usable general-purpose LES codes for complex geometries are typically academic or proprietary/commercial in nature. In this report the objective is to develop and disseminate an open source LES tool for low-Mach number turbulent combustion using the OpenFOAM framework. In particular, a collocated-mesh approach suited for unstructured grid formulation is provided. Unlike other fluid dynamics models, LES accuracy is intricately linked to so-called primary and secondary conservation properties of the numerical discretization schemes. This implies that although the solver only evolves equations for mass, momentum, and energy, the implied discrete equation for kinetic energy (square of velocity) should be minimally-dissipative. Here, a specific spatial and temporal discretization is imposed such that this kinetic energy dissipation is minimized. The method is demonstrated using manufactured solutions approach on regular and skewed meshes for a canonical flow and a lab-scale turbulent flow problem.

42 ENGINEERING↗

Physics‐Informed Machine Learning Method for Large‐Scale Data Assimilation Problems

Abstract We develop a physics‐informed machine learning approach for large‐scale data assimilation and parameter estimation and apply it for estimating transmissivity and hydraulic head in the two‐dimensional steady‐state subsurface flow model of the Hanford Site given synthetic measurements of said variables. In our approach, we extend the physics‐informed conditional Karhunen‐Loéve expansion (PICKLE) method to modeling subsurface flow with unknown flux (Neumann) and varying head (time‐dependent Dirichlet) boundary conditions. We demonstrate that the PICKLE method is comparable in accuracy with the standard maximum a posteriori (MAP) method, but is significantly faster than MAP for large‐scale problems. Both methods use a mesh to discretize the computational domain. In MAP, the parameters and states are discretized on the mesh; therefore, the size of the MAP parameter estimation problem directly depends on the mesh size. In PICKLE, the mesh is used to evaluate the residuals of the governing equation, while the parameters and states are approximated by the truncated conditional Karhunen‐Loéve expansions with the number of parameters controlled by the smoothness of the parameter and state fields, and not by the mesh size. For a considered example, we demonstrate that the computational cost of PICKLE increases near linearly (as N 1.15 ) with the number of grid nodes N , while that of MAP increases much faster (as N 3.28 ). We also show that once trained for one set of Dirichlet boundary conditions (i.e., one river stage), the PICKLE method provides accurate estimates of the hydraulic head for any value of the Dirichlet boundary conditions (i.e., for any river stage).

97 MATHEMATICS AND COMPUTING↗