At least 361 records · Page 20

Holography vs. Scale Separation

In this work, we point out a contradiction between holography and scale-separated AdS (i.e. parametrically large mass gap) in string theory, making the standard assumption that the holographic CFT describes the IR degrees of freedom on a brane that decouple from gravity. We show that the CFT can only decouple from gravity if the scalar potential in the dual AdS satisfies a certain criterion. Namely, there must exist a scalar field trajectory that follows the gradient of the scalar potential to the asymptotic region of the scalar field space in which limit $\partial_ϕ\ln(V)\partial_ϕ\ln(Λ_s)\leq2/(d-2)$, where $Λ_s$ is the quantum gravity cut-off. This condition, which generically implies lack of scale-separation, is satisfied in the standard examples of AdS/CFT. However, proposed attempts at achieving scale separation, such as DGKT, employ scalar potentials that violate this condition. We therefore conclude that the CFT duals of DGKT vacua cannot exist in string theory. Barring fine-tuning, our conclusions apply to other Ricci-flat flux compactifications including the KKLT scenario which relies on scale separation to obtain a metastable de Sitter uplift.

FOS: Physical sciences↗

Upwind vs. downwind: loads and acoustics of a 1.5 MW wind turbine

This paper discusses the motivation, preparation, risk mitigation, execution, and results of a full-scale experiment where the conventional upwind rotor of a 1.5 MW wind turbine was operated in a downwind configuration. The experiment took place at the National Renewable Energy Laboratory Flatirons Campus in Colorado, USA, and involved the collection of loads and power together with acoustic measurements from an array of four microphones. To validate the numerical predictions of the aeroelastic solver OpenFAST in terms of loads and performance, 410 min of downwind operation and 960 min of conventional upwind operations were used. In the wind speed range from 4.5 to 12.5 m s−1, the downwind rotor generates higher damage equivalent loads for the blade root flapwise moment, blade root edgewise moment, and tower-base fore-aft moment compared to the upwind rotor. For these metrics of fatigue loads, numerical predictions match the experimental observations well. OpenFAST is, however, also seen underpredicting a power gain in the downwind rotor. In terms of acoustics, the overall sound pressure levels recorded in the field are similar between the upwind and downwind cases, but downwind operation worsens the metrics describing amplitude modulation.

17 WIND ENERGY↗

Difference in load predictions obtained with effective turbulence vs. a dynamic wake meandering modeling approach

Abstract. According to the international standard for wind turbine design, the effects of wind turbine wakes on structural loads can be considered in two ways: (1) by augmenting the ambient turbulence levels with the effective turbulence model (EFF) and then calculating the resulting loads and (2) by performing dynamic wake meandering (DWM) simulations, which compute wake effects and loads for all turbines on a farm at once. There is no definitive answer in scientific literature as to the consequences of choosing one model over the other, but the two approaches are unarguably very different. The work presented here expounds on these differences and investigates to what extent they affect the simulated structural loads. We consider an idealized 4×4 rectangular array of National Renewable Energy Laboratory 5 MW wind turbines with a spacing of 5 by 8 rotor diameters and three wind speed scenarios at high ambient turbulence. Load simulations are performed in OpenFAST with EFF and in FAST.Farm with the DWM implementation. We compare ambient turbulence, wind farm turbulence, and loads between both approaches. When omnidirectional results are compared, EFF wind farm turbulence intensity is consistently higher by 0.2 % (above-rated wind speed) to 2.7 % (below-rated wind speed). However, for certain wind directions, the EFF turbulence can be lower than FAST.Farm by almost 9 %. Wind speeds within the farm were found to differ by up to 3 m s−1 due to the lack of wake deficits in the EFF approach, leading to longer tails toward low values in the FAST.Farm mean load distributions. Consistent with the turbulence results, the median EFF load standard deviations are also consistently higher, by a maximum of 20 % and 17 % for blade-root out-of-plane and tower-base fore-aft moments, respectively.

17 WIND ENERGY↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Total variation vs L1 regularization: a comparison of compressive sensing optimization methods for chemical detection

One of the fundamental assumptions of compressive sensing (CS) is that a signal can be reconstructed from a small number of samples by solving an optimization problem with the appropriate regularization term. Two standard regularization terms are the L1 norm and the total variation (TV) norm. We present a comparison of CS reconstruction results based on these two approaches in the context of chemical detection, and we demonstrate that optimization based on the L1 norm outperforms optimization based on the TV norm. Our comparison is driven by CS sampling, reconstruction, and chemical detection in two real-world datasets: the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset and the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset. Both datasets contain the release of a chemical simulant such as glacial acetic acid, triethyl phosphate, and sulfur hexafluoride. For chemical detection we use the adaptive coherence estimator (ACE) and bulk coherence, and we propose algorithmic ACE thresholds to define the presence or absence of a chemical of interest in both un-compressed data cubes and reconstructed data cubes. The un-compressed data cubes provide an approximate ground truth. We demonstrate that optimization based on either the L1 norm or TV norm results in successful chemical detection at a compression rate of 90%, but we show that L1 optimization is preferable. We present quantitative comparisons of chemical detection on reconstructions from the two methods, with an emphasis on the number of pixels with an ACE value above the threshold.

Hyperspectral imagery, L1-norm, total variation, A↗

Molten Salt vs. Liquid Sodium Receiver Selection Using the Analytic Hierarchy Process: Preprint

An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ °C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process (AHP) to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six-month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two-tank chloride salt thermal energy storage system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Emitter Reconstruction for Cleaved CdSexTe1-x Devices with Cu vs. As Doping

CdTe absorbers have had historically low carrier densities of ~10^14 cm-3 due to the self-compensating nature of copper dopants. Recent advances in group-V (e.g., arsenic) doping have increased this to 10^16-10^17 cm-3, but modeling suggests that the front interface and emitter properties become limiting in this case. By cleaving arsenic- and copper-doped CdTe device stacks at the emitter/absorber interface, we gain the ability to reconstruct emitters with known properties, which will not change during subsequent device processing, and directly test the modeling. By doing so, we find a much larger performance drop in arsenic devices; this is attributed to insufficient electron density in the emitter and increased sensitivity to interface changes due to collapsed depletion width. This work can help guide emitter engineering for highly-doped CdTe devices in both the as-grown-superstrate- and cleaved-substrate configurations.

As-doped↗

Molten Salt vs. Liquid Sodium Receiver Selection Using the Analytic Hierarchy Process

An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ degrees C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six-month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two-tank chloride salt thermal energy storage system.

central receiver↗