At least 361 records · Page 20

Integral inverter/battery charger for use in electric vehicles

The design and test results of a thyristor based inverter/charger are discussed. A battery charger is included integral to the inverter by using a subset of the inverter power circuit components. The resulting charger provides electrical isolation between the vehicle propulsion battery and ac line and is capable of charging a 25 kWh propulsion battery in 8 hours from a 220 volt ac line. The integral charger employs the inverter commutation components at a resonant ac/dc isolated converter rated at 3.6 kW. Charger efficiency and power factor at an output power of 3.6 kW are 86% and 95% respectively. The inverter, when operated with a matching polyphase ac induction motor and nominal 132 volt propulsion battery, can provide a peak shaft power of 34 kW (45 ph) during motoring operation and 45 kW (60 hp) during regeneration. Thyristors are employed for the inverter power switching devices and are arranged in an input-commutated topology. This configuration requires only two thyristors to commutate the six main inverter thyristors. Inverter efficiency during motoring operation at motor shaft speeds above 450 rad/sec (4300 rpm) is 92-94% for output power levels above 11 KW (15 hp). The combined ac inverter/charger package weighs 47 kg (103 lbs).

Thimmesch, D.↗

Deep diode arrays for X-ray detection

Temperature gradient zone melting process was used to form p-n junctions in bulk of high purity silicon wafers. These diodes were patterned to form arrays for X-ray spectrometers. The whole fabrication processes for these X-ray detectors are reviewed in detail. The p-n junctions were evaluated by (1) the dark diode I-V measurements, (2) the diode C sub I - V measurements, and (3) the MOS C-V measurements. The results showed that these junctions were linearly graded in charge distribution with low reverse bias leakage current flowing through them (few nA at -10 volts). The X-ray detection experiments showed that an FWHM of 500 eV was obtained from these diodes with a small bias of just -5 volts (for X-ray source Fe55). A theoretical model was proposed to explain the extra peaks found in the energy spectra and a very interesting point - cross talk effect was pointed out. This might be a solution to the problem of making really high resolution X-ray spectrometers.

Zemel, J. N.↗

Design considerations for high-power VHF radar transceivers: The Poker Flat MST radar phase control system

Sixty-four separate 50-kW peak-power transmitters are distributed throughout the 200 x 200 meter Poker Flat MST radar antenna array. The relative phase of each transmitter is automatically controlled by a 64-channel unit located in the main building at the edge of the antenna. The phase control unit is described. In operation the RF pulse from a transmitter coupler is power divided and compared with the phase reference in a mixer. The mixer output is low-pass filtered and sampled near the center of the resulting video pulse by an amplifying sample-and-hold integrated circuit. Phase control is effected by maintaining the mixer output pulse near zero volts by amplifying the sample-and-hold output which then drives the voltage-controlled phase shifter in the direction to null the mixer output. The voltage-controlled shifter achieves over 360 deg phase shift in the range from 0.7 to 24 volts. When the voltage into the shifter tracks to either voltage limit the wrap-around control resets the voltage so that the shifter is always operating within its control range.

Ecklund, W. L.↗

Hy-wire measurements of atmospheric potential

A method for directly measuring the electric potential drop across the lowest portion of the atmosphere by using an apparatus called Hy-wire is described. The Hy-wire system consists of a long, high-voltage, insulated conductor connected at the top to a wire-mesh braid and terminated at the bottom inside a large-diameter corona ball mounted on 1 m Teflon legs. The system impedance is near 10 billion ohms, while the grounded mode, Hy-wire draws about 10 micro-a at 500 m altitude. Around-the-clock measurements with characteristic peaks near 1530 and 1900 UT of potentials near 125,000 volts are presented, with total daily average potential near 90,000 volts at 507 m altitude. The experimental weather conditions varied from clear to local fog, except that there was only trace precipitation. The data have been interpreted in terms of the possible source of the potential variations; neither a local nor a global source is clearly indicated.

Holzworth, R. H.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure. Previously announced in STAR as N83-25038

Smithrick, J. J.↗

The discharge mechanism of the high-temperature arc

The mechanism of the high temperature Ar arc is interpreted considering those essential points in which it deviates from the known arcs based on earlier measurements and experiments. The following points are discussed individually: the charge carrier balance, the energy balance, the volt amp characteristics, and the difference between high temperature arcs in Ar and N. Besides the volt amp characteristic of a 10 mm long arc in Ar between 10 and 200 amp, the anode fall, cathode fall, and arc gradient were obtained with the aid of probes. The difference between Ar and N arcs are attributed to variations of the heat conditions and electrical conditions at different temperatures of the gas.

Busz-Peuckert, G.↗

Surface interactions and high-voltage current collection

Spacecraft of the future will be larger and have higher power requirements than any flown to date. For several reasons, it is desirable to operate a high power system at high voltage. While the optimal voltages for many future missions are in the range 500 to 5000 volts, the highest voltage yet flown is approximately 100 volts. The NASCAP/LEO code is being developed to embody the phenomenology needed to model the environmental interactions of high voltage spacecraft. Some plasma environment are discussed. The treatment of the surface conductivity associated with emitted electrons and some simulations by NASCAP/LEO of ground based high voltage interaction experiments are described.

Mandell, M. J.↗

Environmentally-induced voltage limitations in large space power systems

Large power systems proposed for future space missions imply higher operating voltage requirements which, in turn, will interact with the space plasma environment. The effects of these interactions can only be inferred because of the limited data base of ground simulations, small test samples, and two space flight experiments. This report evaluates floating potentials for a 100 kW power system operating at 300, 500, 750, and 1000 volts in relation to this data base. Of primary concern is the possibility of discharging to space. The implications of such discharges were studied at the 500 volt operational setting. It was found that discharging can shut down the power system if the discharge current exceeds the array short circuit current. Otherwise, a power oscillation can result that ranges from 2 to 20 percent, depending upon the solar array area involved in the discharge. Means of reducing the effect are discussed.

Stevens, N. J.↗

Unbalanced-to-Balanced Video Interface

Equal but opposite video waveforms generated. Unbalanced input line terminated in 75-ohm resistor, R1. Capacitor C1 blocks dc component of input so only time-varying component fed to Q1 and inverted in polarity. Circuit intended for use with input television signal having polarity, amplitude, and dc bias such that tips of synchronizing pulses lie at zero volts while reference white level is specified positive dc level (typically about 1 volt).

Richardson, J. E.↗

Voltage Regulators for Photovoltaic Systems

Two simple circuits developed to provide voltage regulation for highvoltage (i.e., is greater than 75 volts) and low-voltage (i.e., is less than 36 volts) photovoltaic/battery power systems. Use of these circuits results in voltage regulator small, low-cost, and reliable, with very low power dissipation. Simple oscillator circuit controls photovoltaic-array current to regulate system voltage and control battery charging. Circuit senses battery (and system) voltage and adjusts array current to keep battery voltage from exceeding maximum voltage.

Delombard, R.↗

Addressable inverter matrix for process and device characterization

The addressable inverter matrix consists of 222 inverters each accessible with the aid of a shift register. The structure has proven useful in characterizing the variability of inverter transfer curves and in diagnosing processing faults. For good 3-micron CMOS bulk inverters investigated, the percent standard deviation of the inverter threshold voltage was less than one percent and the inverter gain (the slope of the inverter transfer curve at the inverter threshold vltage) was less than 3 percent. The average noise margin for the inverters was near 2 volts for a power supply voltage of 5 volts. The specific faults studied included undersize pull-down transistor widths and various open contacts in the matrix.

Buehler, M. G.↗

Addressable inverter matrix for process and device characterization

The addressable inverter matrix consists of 222 inverters each accessible with the aid of a shift register. The structure has proven useful in characterizing the variability of inverter transfer curves and in diagnosing processing faults. For good 3-micron CMOS bulk inverters investigated in this study, the percent standard deviation of the inverter threshold voltage was less than one percent and the inverter gain (the slope of the inverter transfer curve at the inverter threshold voltage) was less than 3 percent. The average noise margin for the inverters was near 2 volts for a power supply voltage of 5 volts. The specific faults studied included undersize pull-down transistor widths and various open contacts in the matrix.

Buehler, M. G.↗

Space station power semiconductor package

A package of high-power switching semiconductors for the space station have been designed and fabricated. The package includes a high-voltage (600 volts) high current (50 amps) NPN Fast Switching Power Transistor and a high-voltage (1200 volts), high-current (50 amps) Fast Recovery Diode. The package features an isolated collector for the transistors and an isolated anode for the diode. Beryllia is used as the isolation material resulting in a thermal resistance for both devices of .2 degrees per watt. Additional features include a hermetical seal for long life -- greater than 10 years in a space environment. Also, the package design resulted in a low electrical energy loss with the reduction of eddy currents, stray inductances, circuit inductance, and capacitance. The required package design and device parameters have been achieved. Test results for the transistor and diode utilizing the space station package is given.

Balodis, Vilnis↗

Variable-Speed, Constant-Frequency Generation Of Power

Feedback of stator power and reactive volt-amperes determines rotor excitation. New method involves control circuit separating rotor excitation into generation of slip frequency and control of amplitude and phase. In control circuit, speed determines slip frequency, while stator power and reactive volt-amperes determine amplitude and phase of rotor current.

Brady, Frank J.↗

Novel nitrogen-based organosulfur electrodes for advanced intermediate temperature batteries

Advanced secondary batteries operating at intermediate temperatures (100 to 200 C) have attracted considerable interest due to their inherent advantages (reduced corrosion and safety risks) over higher temperature systems. Current work in this laboratory has involved research on a class of intermediate temperature Na/beta double prime- alumina/RSSR batteries conceptually similar to Na/S cells, but operating within a temperature range of 100 to 150 C, and having an organosulfur rather than inorganic sulfur positive electrode. The organosulfur electrodes are based on the reversible, two electron eduction of organodisulfides to the corresponding thiolate anions, RSSR + 2 electrons yield 2RS(-), where R is an organic moiety. Among the advantages of such a generic redox couple for battery research is the ability to tailor the physical, chemical, and electrochemical properties of the RSSR molecule through choice of the organic moiety. The viscosity, liquidus range, dielectric constant, equivalent weight, and redox potential can in fact be verified in a largely predictable manner. The current work concerns the use of multiple nitrogen organosulfur molecules, chosen for application in Na/RSSR cells for their expected oxidizing character. In fact, a Na/RSSR cell containing one of these materials, the sodium salt of 5-mercapto 1-methyltetrazole, yielded the highest open circuit voltage obtained yet in the laboratory; 3.0 volts in the charged state and 2.6 volts at 100 percent discharge. Accordingly, the cycling behavior of a series of multiple nitrogen organodisulfides as well as polymeric organodisulfides are presented in this manuscript.

Visco, S. J.↗

Polar wind ion bands after neutral sheet acceleration

The transport of polar wind protons from their ionospheric source through the magnetosphere is examined, using three-dimensional particle codes. The trajectory simulations demonstrate the escape of the high-latitude polar wind in the boundary layers during the quiescent magnetosphere, and, in contrast, its trapping in the nightside plasma sheet at times of high Kp. It is shown that the equatorial curvature of the magnetic field lines plays the role of an acceleration filter which yields, during active conditions, an 'ion band'-like precipitation of the polar wind protons characterized by a decrease of the downflowing ion energy with latitude, from several hundred down to a few electron volts. A further comparison between data and computations tends to indicate that, during disturbed times, the dayside originating polar wind provides an important contribution to the hundreds of electron volt downflowing protons in the nightside sector.

Delcourt, D. C.↗

The effect of electrode configuration on arcjet performance

A segmented anode/nozzle for a low-power (1 kW) arc jet thruster was fabricated to investigate the effect of electrode configuration on the arc jet performance. The five segments of the nozzle, which could be isolated individually or in groups made it possible to observe current distribution from the constrictor through the diverging section of the nozzle; measurements of the potential difference between the cathode and any of the individual segments were possible. Results showed that the discharge initiates in the high pressure region of the nozzle upstream of the diverging section, and then rapidly moves to the diverging section of the nozzle. When the arc was allowed to seat in the diverging section, the anode fall voltage was between 10 to 20 volts. When the current was forced to the high-pressure section of the constrictor, the anode fall voltage increased to more than 40 volts.

Curran, Frank M.↗

Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control subsystem, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.

Schmeckpeper, K. R.↗