Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VASCULAR DISEASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Percutaneous CT-Guided Biopsy of C3 Vertebral Body: Modified Approach for an Old Procedure

Percutaneous biopsy of upper cervical vertebrae is challenging due to the various critical structures in the location and often requires difficult trajectory such as transoral or paramaxillary approaches. The purpose of this manuscript is to illustrate the utility of head rotation in creating a potential space for direct percutaneous access to C3 vertebral body for safe biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cryotherapy of Vascular Malformation: Initial Experience

The present report describes a case of percutaneous cryotherapy in a 36-year-old woman with a large and painful pectoral venous malformation. Cryoablation was performed in a single session for this 9-cm mass with 24 h hospitalisation. At 2- and 6-month follow-up, the pain had completely disappeared, and magnetic resonance imaging demonstrated a significant decrease in size. Percutaneous cryoablation shows promise as a feasible and apparently safe method for local control in patients with symptomatic venous vascular malformations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Revascularization for Acute Ischemic Stroke: A Single-Center, Retrospective Analysis

BackgroundEndovascular mechanical revascularization (thrombectomy) is an increasingly used method for intracranial large vessel recanalization in acute stroke. The purpose of the study was to analyze the recanalization rate, clinical outcome, and complication rate in our stroke patients treated with mechanical revascularization. A total of 57 patients with large vessel stroke (within 3 h for anterior and 12 h for posterior circulation) were treated with mechanical revascularization at a single center during 24 months. The primary goal of endovascular treatment using different mechanical devices was recanalization of the occluded vessel. Recanalization rate (reported as thrombolysis in cerebral infarction [TICI] score), clinical outcome (reported as National Institutes of Health Stroke Scale [NIHSS] score and modified Rankin scale [mRS] score), as well as periprocedural complications were analyzed. The mean age of the patients was 63.1 {+-} 12.9 years, with baseline median NIHSS score of 14 (interquartile range, 9.5-19). Successful recanalization (TICI 2b or 3) was achieved in 41 (72 %) patients. Twenty patients (35 %) presented with favorable outcome (mRS {<=}2) 30 days after stroke. Overall, significant neurological improvement ({>=}4 NIHSS point reduction) occurred in 36 (63 %) patients. A clinically significant procedure-related adverse events (vessel disruption, peri/postprocedural intracranial bleeding) defined with decline in NIHSS of {>=}4 or death occurred in three (5 %) patients. The study showed a high recanalization rate with improved clinical outcome and a low rate of periprocedural complications in our stroke patients treated with mechanical revascularization. Therefore, we could conclude that endovascular revascularization (primary or in combination with a bridging thrombolysis) was an effective and safe procedure for intracranial large vessel recanalization in acute stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transseptal Guidewire Stabilization for Device Closure of a Large Pulmonary Arteriovenous Malformation

A 46-year-old man presenting with massive hemoptysis was found to have a large pulmonary arteriovenous malformation (PAVM) in the right lung. Closure of the PAVM with an Amplatzer-type duct occluder was hampered by inability to advance the device delivery sheath into the PAVM due to vessel tortuosity and inadequate guidewire support. Atrial septal puncture was performed and a femorofemoral arteriovenous guidewire loop through the right pulmonary artery, PAVM, and left atrium was created. Traction on both ends of the guidewire loop allowed advancement of the device delivery sheath into the PAVM and successful completion of the procedure. Transseptal guidewire stabilization can be a valuable option during device closure of large PAVMs when advancement, stability, or kinking of the device delivery sheath is an issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Foot Drop after Ethanol Embolization of Calf Vascular Malformation: A Lesson on Nerve Injury

Ethanol is often used in sclerotherapy to treat vascular malformations. Nerve injury is a known complication of this procedure. However, the management of this complication is not well described in literature. This case describes a 10-year-old boy with a slow flow vascular malformation in the right calf who underwent transarterial ethanol embolization following prior unsuccessful direct percutaneous sclerotherapy. The development of a dense foot drop that subsequently recovered is described, and the management of this uncommon but distressful complication is discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Randomized Comparison of Uterine Artery Embolization (UAE) with Surgical Treatment in Patients with Symptomatic Uterine Fibroids (REST Trial): Subanalysis of 5-Year MRI Findings

Purpose. To report 5-year contrast-enhanced magnetic resonance imaging findings of the REST trial recruits who underwent either uterine artery embolization (UAE) or myomectomy. Methods. A total of 157 patients were randomized to UAE or surgery (hysterectomy or myomectomy). Ninety-nine patients who had UAE and eight patients who had myomectomy were analyzed. MRI scans at baseline, 6 months, and 5 years were independently interpreted by two radiologists. Dominant fibroid diameter, uterine volume, total fibroid infarction (complete 100 %, almost complete 90-99 %, partial <90 %), and new fibroid formation were the main parameters assessed and related to the need for reintervention. Results. In the UAE group, mean {+-} standard deviation uterine volume was 670 {+-} 503, 422 {+-} 353, and 292 {+-} 287 mL at baseline, 6 months, and 5 years, respectively. Mean dominant fibroid diameter was 7.6 {+-} 3.0, 5.8 {+-} 2.9, and 5 {+-} 2.9 cm at baseline, 6 months, and 5 years. Fibroid infarction at 6 months was complete in 35 % of women, almost complete in 29 %, and partial in 36 %. Need for reintervention was 19, 10, and 33 % in these groups, respectively (p = 0.123). No myomectomy cases had further intervention. At 5 years, the prevalence of new fibroid was 60 % in the myomectomy group and 7 % in the UAE group (p = 0.008). Conclusion. There is a further significant reduction in both uterine volume and dominant fibroid diameter between 6 months and 5 years after UAE. Complete fibroid infarction does not translate into total freedom from a subsequent reintervention. New fibroid formation is significantly higher after myomectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aberrant Left Inferior Bronchial Artery Originating from the Left Gastric Artery in a Patient with Acute Massive Hemoptysis

Massive hemoptysis is a life-threatening condition, and the major source of bleeding in this condition is the bronchial circulation. Bronchial artery embolization is a safe and effective treatment for controlling hemoptysis. However, the sites of origin of the bronchial arteries (BAs) have numerous anatomical variations, which can result in a technical challenge to identify a bleeding artery. We present a rare case of a left inferior BA that originated from the left gastric artery in a patient with recurrent massive hemoptysis caused by bronchiectasis. The aberrant BA was embolized, and hemoptysis has been controlled for 8 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36 h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Posterior Wall Capture and Femoral Artery Stenosis Following Use of StarClose Closing Device: Diagnosis and Therapy

A case of femoral artery obstruction following application of a StarClose type arterial puncture closing device (APCD) is presented. Ultrasonographic and angiographic imaging of this complication was obtained. The posterior wall of the vessel was accidentally caught in the anchoring element of the nitinol clip. This complication was successfully resolved by endovascular treatment and the implantation of a stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗