Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Line-driven winds revisited in the context of Be stars: Ω-slow solutions with high k values

The standard, or fast, solutions of m-CAK line-driven wind theory cannot account for slowly outflowing disks like the ones that surround Be stars. It has been previously shown that there exists another family of solutions—the Ω-slow solutions—that is characterized by much slower terminal velocities and higher mass-loss rates. We have solved the one-dimensional m-CAK hydrodynamical equation of rotating radiation-driven winds for this latter solution, starting from standard values of the line force parameters (α, k, and δ), and then systematically varying the values of α and k. Terminal velocities and mass-loss rates that are in good agreement with those found in Be stars are obtained from the solutions with lower α and higher k values. Furthermore, the equatorial densities of such solutions are comparable to those that are typically assumed in ad hoc models. For very high values of k, we find that the wind solutions exhibit a new kind of behavior.

79 ASTRONOMY AND ASTROPHYSICS↗

STRONGLY LENSED JETS, TIME DELAYS, AND THE VALUE OF H {sub 0}

In principle, the most straightforward method of estimating the Hubble constant relies on time delays between mirage images of strongly lensed sources. It is a puzzle, then, that the values of H {sub 0} obtained with this method span a range from ∼50-100 km s{sup –1}Mpc{sup –1}. Quasars monitored to measure these time delays are multi-component objects. The variability may arise from different components of the quasar or may even originate from a jet. Misidentifying a variable-emitting region in a jet with emission from the core region may introduce an error in the Hubble constant derived from a time delay. Here, we investigate the complex structure of the sources as the underlying physical explanation of the wide spread in values of the Hubble constant based on gravitational lensing. Our Monte Carlo simulations demonstrate that the derived value of the Hubble constant is very sensitive to the offset between the center of the emission and the center of the variable emitting region. Therefore, we propose using the value of H {sub 0} known from other techniques to spatially resolve the origin of the variable emission once the time delay is measured. We particularly advocate this method for gamma-ray astronomy, where the angular resolution of detectors reaches approximately 0.°1; lensed blazars offer the only route for identify the origin of gamma-ray flares. Large future samples of gravitationally lensed sources identified with Euclid, SKA, and LSST will enable a statistical determination of H {sub 0}.

79 ASTRONOMY AND ASTROPHYSICS↗

Variance control in weak-value measurement pointers

The variance of an arbitrary pointer observable is considered for the general case that a complex weak value is measured using a complex valued pointer state. For the typical cases where the pointer observable is either its position or momentum, the associated expressions for the pointer's variance after the measurement contain a term proportional to the product of the weak value's imaginary part with the rate of change of the third central moment of position relative to the initial pointer state just prior to the time of the measurement interaction when position is the observable--or with the initial pointer state's third central moment of momentum when momentum is the observable. These terms provide a means for controlling pointer position and momentum variance and identify control conditions which, when satisfied, can yield variances that are smaller after the measurement than they were before the measurement. Measurement sensitivities which are useful for estimating weak-value measurement accuracies are also briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Updated evaluation of potential ultralow Q -value β -decay candidates

“Ultralow” Q-value β decays are referred to as such due to their low decay energies of less than ≈1 keV. Such a low energy decay is possible when the parent nucleus decays to an excited state in the daughter, with an energy close to that of the Q value. These decays are of interest as potential new candidates for neutrino mass determination experiments and as a testing ground for studies of atomic interference effects in the nuclear decay process. In this paper, we provide an updated evaluation of atomic mass data and nuclear energy-level data to identify potential ultralow Q-value β decay candidates. For many of these candidates, more precise and accurate atomic mass data is needed to determine if the Q value of the potential ultralow decay branch is energetically allowed and in fact ultralow. Furthermore, the relevant precise atomic mass measurements can be achieved via Penning trap mass spectrometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-throughput determination of Hubbard $U$ and Hund $J$ values for transition metal oxides via the linear response formalism

DFT+U provides a convenient, cost-effective correction for the self-interaction error (SIE) that arises when describing correlated electronic states using conventional approximate density functional theory (DFT). The success of a DFT+U(+J) calculation hinges on the accurate determination of its Hubbard U and Hund J parameters, and the linear response (LR) methodology has proven to be computationally effective and accurate for calculating these parameters. This study provides a high-throughput computational analysis of the U and J values for transition metal d-electron states in a representative set of over 1000 magnetic transition metal oxides (TMOs), providing a frame of reference for researchers who use DFT+U to study transition metal oxides. In order to perform this high-throughput study, an ATOMATE workflow is developed for calculating U and J values automatically on massively parallel supercomputing architectures. Here, to demonstrate an application of this workflow, the spin-canting magnetic structure and unit cell parameters of the multiferroic olivine LiNiPO4 are calculated using the computed Hubbard U and Hund J values for Ni-d and O-p states, and are compared with experiment. Both the Ni-d U and J corrections have a strong effect on the Ni-moment canting angle. Additionally, including a O-pU value results in a significantly improved agreement between the computed lattice parameters and experiment

36 MATERIALS SCIENCE↗

Value to the Grid From Managed Charging Based on California's High Renewables Study

Managed charging of electric vehicle (EV) loads has the potential to use renewable energy more effectively, shave peak demand, and fill demand valleys while serving transportation needs. However, the potential value to the grid from managed charging has not been fully quantified. This paper adopts the tools used in the National Renewable Energy Laboratory's California Low Carbon Grid Study to quantify value to the grid from managed charging by using three levels of managed loads for 13 terawatt-hours of annual load from three million EVs in a 2030 California grid scenario. Simulation results show that management of the EV fleet's aggregate load from unmanaged to 100% managed results in savings between 210 million and 660 million annually in generation system costs, depending on grid conditions. The simulation results also suggest that targeted EV supply equipment (EVSE) deployments at workplaces and other mid-day parking locations will be needed to support managed charging in a high-renewables California and enable the identified value to the grid. Although the value of generation to the grid from managed EV load paired with high renewables seems substantial, we estimate that the installed cost of an EVSE must be between 1,000 and 3,000 for a 10-year life to be cost neutral, depending on grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Complex-valued universal linear transformations and image encryption using spatially incoherent diffractive networks

As an optical processor, a diffractive deep neural network (D2NN) utilizes engineered diffractive surfaces designed through machine learning to perform all-optical information processing, completing its tasks at the speed of light propagation through thin optical layers. With sufficient degrees of freedom, D2NNs can perform arbitrary complex-valued linear transformations using spatially coherent light. Similarly, D2NNs can also perform arbitrary linear intensity transformations with spatially incoherent illumination; however, under spatially incoherent light, these transformations are nonnegative, acting on diffraction-limited optical intensity patterns at the input field of view. Here, we expand the use of spatially incoherent D2NNs to complex-valued information processing for executing arbitrary complex-valued linear transformations using spatially incoherent light. Through simulations, we show that as the number of optimized diffractive features increases beyond a threshold dictated by the multiplication of the input and output space-bandwidth products, a spatially incoherent diffractive visual processor can approximate any complex-valued linear transformation and be used for all-optical image encryption using incoherent illumination. The findings are important for the all-optical processing of information under natural light using various forms of diffractive surface-based optical processors.

36 MATERIALS SCIENCE↗

Measurement of the infrared optical constants for spectral modeling: n and k values for (NH4)2SO4 via single-angle reflectance and ellipsometric methods

The optical constants n and k can be used to model infrared spectra, including refraction, absorption, reflectance, and emissivity, but obtaining reliable values for solid materials (pure or otherwise) presents a challenge: In the past, the best results for n and k have been obtained from bulk, homogeneous materials, free of defects. That is, materials where the Fresnel equations are operant since there is no light scattering. Since it is often not possible to obtain a pure macroscopic (crystalline) material, it may be possible to press the material into a (uniform, void-free) disk. We have recently been able to do this with ammonium sulfate powder and then measured the n & k values via two independent methods: 1) Ellipsometry - which measures the changes in amplitude and phase of light reflected from the material of interest as a function of wavelength and angle of incidence, and 2) Single angle specular reflectance with an FT spectrometer using a specular reflectance device within an FT instrument which measures the change in amplitude of light reflected from the material of interest as a function of wavelength and angle of incidence over a wide wavelength range. The quality of the derived n & k values was tested by generating the reflectance spectra of the pellet and comparing to the calculated to measured reflectance spectra of the pure material which has been previously published. The comparison to literature values showed good accuracy and good agreement, indicating promise to measure other materials by such methods.

ammonium sulfate↗

SU-E-T-161: Characterization and Validation of CT Simulator Hounsfield Units to Relative Stopping Power Values for Proton Treatment Planning

Purpose: To develop a calibration curve that includes and minimizes the variations of Hounsfield Unit (HU) from a CT scanner to Relative Stopping Power (RSP) of tissues along the proton beam path. The variations are due to scanner and proton energy, technique, phantom size and placement, and tissue arrangement. Methods: A CIRS 062 M phantom with 10 plugs of known relative electron density (RED) was scanned through a 16 slice GE Discovery CT Simulator scanner. Three setup combinations of plug distributions and techniques clinically implemented for five treatment regions were scanned with energies of 100, 120, and 140 kV. Volumetric HU values were measured for each plug and scan. The RSP values derived through the Bethe-Bloch formula are currently being verified with parallel-plate ionization chamber measurements in water using 80, 150, and 225 MeV proton beam. Typical treatment plans for treatment regions of brain, head-&-neck, chest, abdomen, and pelvis are being planned and dose delivered will be compared with film and Optically Stimulated Luminescence (OSL) measurements. Results: Percentage variations were determined for each variable. For tissues close to water, variations were <1% from any given parameter. Tissues far from water equivalence (lung and bone) showed the greatest sensitivity to change (7.4% maximum) with scanner energy and up to 5.3% with positioning of the phantom. No major variations were observed for proton energies within the treatment range. Conclusion: When deriving a calibration curve, attention should be placed to low and high HU values. A thorough verification process of calculated vs. water-phantom measured RSP values at different proton energies, followed by dose validation of planned vs. measured doses in phantom with film and OSL detectors are currently being undertaken.

60 APPLIED LIFE SCIENCES↗

SU-E-T-271: Direct Measurement of Tenth Value Layer Thicknesses for High Density Concretes with a Clinical Machine

Purpose: Use of high density concrete for radiation shielding is increasing, trading cost for space savings associated with the reduced tenth value layer (TVL). Precise information on the attenuation properties of high-density concretes is not readily present in the literature. A simple approximation is to scale the TVLs from NCRP 151 according relative increase in density. Here we present measured TVLs for heavy concretes of various densities using a built-in shielding test port. Methods: Concrete densities tested range from 2.35 g cc{sup −1} (147 pcf) to 5.6 g cc{sup −1} (350 pcf). Measurements were taken using 6MV, 6FFF, and 10FFF on a Varian Truebeam linear accelerator. Field sizes of 4x4, 9x9 and 30x30 cm{sup 2} were measured. A PTW 31013 Farmer chamber with a buildup cap was positioned 5.5 m from isocenter along the beam CAX. Concrete thicknesses were incremented in 5 cm intervals. Comparison TVLs were determined by scaling the NCRP 151 TVLs by the density ratio between the sample and standard density. Results: The trend from the first to equilibrium TVL was an increase in thickness, compared with MC modeling, which predicted a decrease. Measured TVLs for 6 MV were reduced by as much as 8.9 cm for TVL{sub 1} and 3.4 cm for TVL{sub E} compared to values scaled from NCRP 151. There was 1–3 mm difference in TVL between measurements done at 4x4 versus 30x30 cm{sup 2}. TVL{sub 1} for 6FFF was 1.1 cm smaller than TVL{sub 1} for 6MV, but TVL{sub E} was consistent to within 4 mm. TVL{sub 1} and TVL{sub E} for 10FFF were reduced by 8.8 and 3.7 cm from scaled NCRP values, respectively. Conclusions: We have measured the TVL thicknesses for various concretes. Simple density scaling of the values in NCRP 151 is a conservatively safe approximation, but actual TVLs may be reduced enough to eliminate some of the expense of installation. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.

43 PARTICLE ACCELERATORS↗

SU-B-BRA-00: The Medical Physicist Value Proposition for Tomorrow and Today

In the current rapidly changing Healthcare environment, many groups are competing for limited resources. How can medical physicists position themselves to be a relevant stakeholder in the discussion of how those resources are allocated Our value goes beyond what can be shown in a business plan and is heavily involved with safety and quality. Three areas will be explored: What is our value? Who needs to receive that message? How do we communicate that message? To help frame the discussion in terms of how other stakeholders may view the value of medical physicists, a physician and an administrator will present their perspective. Lastly, a multidisciplinary panel will present real life examples of strategies that can be utilized today to establish the value of medical physicists. The presentation of these examples will lead into an interactive question and answer time. V. Willcut, I work for Elekta. There was no research associated with this talk.

60 APPLIED LIFE SCIENCES↗

SU-B-BRA-02: The Medical Physics Value Proposition for Tomorrow and Today

In the current rapidly changing Healthcare environment, many groups are competing for limited resources. How can medical physicists position themselves to be a relevant stakeholder in the discussion of how those resources are allocated Our value goes beyond what can be shown in a business plan and is heavily involved with safety and quality. Three areas will be explored: What is our value? Who needs to receive that message? How do we communicate that message? To help frame the discussion in terms of how other stakeholders may view the value of medical physicists, a physician and an administrator will present their perspective. Lastly, a multidisciplinary panel will present real life examples of strategies that can be utilized today to establish the value of medical physicists. The presentation of these examples will lead into an interactive question and answer time. V. Willcut, I work for Elekta. There was no research associated with this talk.

60 APPLIED LIFE SCIENCES↗

SU-B-BRA-03: A Physician Perspective on the Value of Medical Physics

In the current rapidly changing Healthcare environment, many groups are competing for limited resources. How can medical physicists position themselves to be a relevant stakeholder in the discussion of how those resources are allocated Our value goes beyond what can be shown in a business plan and is heavily involved with safety and quality. Three areas will be explored: What is our value? Who needs to receive that message? How do we communicate that message? To help frame the discussion in terms of how other stakeholders may view the value of medical physicists, a physician and an administrator will present their perspective. Lastly, a multidisciplinary panel will present real life examples of strategies that can be utilized today to establish the value of medical physicists. The presentation of these examples will lead into an interactive question and answer time. V. Willcut, I work for Elekta. There was no research associated with this talk.

60 APPLIED LIFE SCIENCES↗

SU-B-BRA-04: An Administrators Perspective on the Value of Medical Physics

In the current rapidly changing Healthcare environment, many groups are competing for limited resources. How can medical physicists position themselves to be a relevant stakeholder in the discussion of how those resources are allocated Our value goes beyond what can be shown in a business plan and is heavily involved with safety and quality. Three areas will be explored: What is our value? Who needs to receive that message? How do we communicate that message? To help frame the discussion in terms of how other stakeholders may view the value of medical physicists, a physician and an administrator will present their perspective. Lastly, a multidisciplinary panel will present real life examples of strategies that can be utilized today to establish the value of medical physicists. The presentation of these examples will lead into an interactive question and answer time. V. Willcut, I work for Elekta. There was no research associated with this talk.

60 APPLIED LIFE SCIENCES↗

SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and pose the potential to affect PET accuracy.

60 APPLIED LIFE SCIENCES↗

Accurate Determination of the Values of Fundamental Physical Constants: The Basis of the New “Quantum” SI Units

The metric system appeared as the system of units designed for macroscopic (laboratory scale) measurements. The progress in accurate determination of the values of quantum constants (such as the Planck constant) in SI units shows that the capabilities in high-precision measurement of microscopic and macroscopic quantities in terms of the same units have increased substantially recently. At the same time, relative microscopic measurements (for example, the comparison of atomic transition frequencies or atomic masses) are often much more accurate than relative measurements of macroscopic quantities. This is the basis for the strategy to define units in microscopic phenomena and then use them on the laboratory scale, which plays a crucial role in practical methodological applications determined by everyday life and technologies. The international CODATA task group on fundamental constants regularly performs an overall analysis of the precision world data (the so-called Adjustment of the Fundamental Constants ) and publishes their recommended values. The most recent evaluation was based on the data published by the end of 2014; here, we review the corresponding data and results. The accuracy in determination of the Boltzmann constant has increased, the consistency of the data on determination of the Planck constant has improved; it is these two dimensional constants that will be used in near future as the basis for the new definition of the kelvin and kilogram, respectively. The contradictions in determination of the Rydberg constant and the proton charge radius remain. The accuracy of determination of the fine structure constant and relative atomic weight of the electron has improved. Overall, we give a detailed review of the state of the art in precision determination of the values of fundamental constants. The mathematical procedure of the Adjustment, the new data and results are considered in detail. The limitations due to macroscopic properties of material standards (such as the International prototype of the kilogram) and the isotopic composition of substances involved in precision studies in general (as standard measures for the triple point of water) and, in particular, in the determination of the fundamental constants are discussed. The perspectives of the introduction of the new quantum units, which will be free from the mentioned problems, are considered. Many physicists feel no sympathy for the International system of units (SI), believing that it does not properly reflect the character of physical laws. In fact, there are three parallel systems, namely the systems of quantities, system of their units and the related standards. The definition of the units, in particular, the SI units, above all, reflects our ability to perform precision measurements of physical values under certain conditions, in particular, to create appropriate standards. This requirement is not related to the beauty of fundamental laws of nature. More accurate determination of the fundamental constants is one of the areas where we accumulate such experience.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toxicity Values for Chemicals

The toxicity values for chemicals contained in this dataset comprise acute, subchronic, and chronic exposure durations. Cancer slope factors, inhalation unit risk, reference dose, and reference concentrations are available. These values should be used in cancer risk and noncancer hazard assessments for the calculation of preliminary remediation goals (PRGs) and hazard characterization. Users can select toxicity values from 10 combinations of exposure durations and cancer/noncancer toxicity values and select up to 1000 chemicals per query. The dataset supports environmental risk assessments, regulatory decision-making, and environmental planning with tools for benchmarking against risk-based standards. This structured approach ensures a robust evaluation of environmental risks tailored to regulatory needs.

Stewart, Debra [Oak Ridge National Laboratory (ORN↗

iBLAST: Incremental BLAST of new sequences via automated e-value correction

Search results from local alignment search tools use statistical scores that are sensitive to the size of the database to report the quality of the result. For example, NCBI BLAST reports the best matches using similarity scores and expect values (i.e., e-values) calculated against the database size. Given the astronomical growth in genomics data throughout a genomic research investigation, sequence databases grow as new sequences are continuously being added to these databases. As a consequence, the results (e.g., best hits) and associated statistics (e.g., e-values) for a specific set of queries may change over the course of a genomic investigation. Thus, to update the results of a previously conducted BLAST search to find the best matches on an updated database, scientists must currently rerun the BLAST search against the entire updated database, which translates into irrecoverable and, in turn, wasted execution time, money, and computational resources. To address this issue, we devise a novel and efficient method to redeem past BLAST searches by introducing iBLAST. iBLAST leverages previous BLAST search results to conduct the same query search but only on the incremental (i.e., newly added) part of the database, recomputes the associated critical statistics such as e-values, and combines these results to produce updated search results. Our experimental results and fidelity analyses show that iBLAST delivers search results that are identical to NCBI BLAST at a substantially reduced computational cost, i.e., iBLAST performs (1 + δ )/ δ times faster than NCBI BLAST, where δ represents the fraction of database growth. We then present three different use cases to demonstrate that iBLAST can enable efficient biological discovery at a much faster speed with a substantially reduced computational cost.

59 BASIC BIOLOGICAL SCIENCES↗