At least 361 records · Page 20

Results of the GCMS Effluent Gas Analysis for the Brine Processing Test

The effluent gas for the Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB) were analyzed using Headspace GCMS Analysis in the recent AES FY14 Brine Processing Test. The results from the analysis describe the number and general chemical species of the chemicals produced. Comparisons were also made between the different chromatograms for each system, and an explanation of the differences in the results is reported.

GCMS↗

Nondestructive testing of welds on thin-walled tubing

Special ultrasonic search unit, or transducer assembly, reliably inspects the quality of melt-through welds of fusion welded tubing couplers for hydraulic lines. This instrumentation can also be used to detect faulty braze bonds in thin-walled, small diameter joints and wall thickness of thin-walled metal tubing.

Hagemaier, D. J.↗

Effect of cavitation on fluid stability in polymer thickened fluids and lubricants

The effects of cavitating flow on the polymeric additives used in functional fluids are described. A comparison of thermal and mechanical stability tests for these polymer solutions show distinct differences in the machanism of the polymer degradation. The thermal degradation tests appear to cause an unzippering or depolymerization type of reaction in which there is no particular selectivity based on molecular weight. The mechanical degradation of these fluids appears to be based on molecular weight. Measurements of molecular weight distributions during mechanical degradation show that for a given level of intensity only molecules above a certain minimum size are degraded. The effects of ultrasonic radiation on polymer degradation are reported. Tests were conducted to demonstrate the mechanism of mechanical polymer degradiation in an orifice. A more severe test than the orifice test in which two tapered roller bearings loaded against each other produce the mechanical breakdown is discussed.

Duda, J. L.↗

Individual recognition between mother and infant bats (Myotis)

The recognition process and the basis for that recognition, in brown bats, between mother and infant are analyzed. Two parameters, ultrasonic communication and olfactory stimuli, are investigated. The test animals were not allowed any visual contact. It was concluded that individual recognition between mother and infant occurred. However, it could not be determined if the recognition was based on ultrasonic signals or olfactory stimuli.

Turner, D.↗

Development and Testing of a Multi-Transducer System for Measuring Height of Condensed Water in Steam Pipes with Steady-State and Turbulent Flow Conditions

One of the critical requirements for ensuring the safety of a steam pipe is to monitor the condensed water level under operation. For this objective, the authors initially developed methods and obtained preliminary test results based on the use of ultrasonic pulse-echo transducers and enhanced signal-processing tool; however, the methodology needed further development in order to obtain measurements in turbulent dynamic flow conditions. To improve the reliability of measurements taken in turbulent flow conditions, an experimental system was developed using multiple transducers driven by a multiplexer, and a data acquisition module capable of operating in any flow conditions. The system consists of a simulation testbed, which allows testing the performance over a range of flow rates and water levels and to observe flow conditions and patterns, as well as measure actual water level, flow velocities, wave conditions, etc. In this paper, we present the development details that include description of the testbed for simulating the flow of condensed water, the multiple transducers arrangement, the signal processing method, and the test results of both steady state and turbulent flow.

Lih, Shyh-Shiuh↗

Noncontact Flow Rate Using Laser Ultrasonics

Several types of advanced nuclear reactors are cooled with high-temperature liquid metal or molten salt flows. There is a critical need to measure flow velocity in flow channels for test purposes, and eventually in operational reactors. In conventional ultrasonic flow sensors, ultrasonic waves traveling in both the upstream and downstream directions are generated and detected by transducers that must contact the flow channels. A shift in the frequency or transit time between the two ultrasonic waves is measured to determine flow velocity. We describe here an initial effort to apply that sensing concept when the contact transducers are replaced by laser-based generation and detection instrumentation. This noncontact sensing avoids many practical problems associated with contact transducers when implemented on flow channels at high temperature. Laser-based flow monitoring can also be applied to hot-process piping in the geothermal energy, chemical-processing and petroleum-refining industries. Our effort has included theoretical simulation of noncontact laser-based flow monitoring, indicating capability of measuring flow velocities relevant to reactor cooling. It also included a room-temperature experimental demonstration using water as the flow liquid, and indicating capability of measuring flow velocity at a responsivity roughly consistent with simulation predictions. Plans were made for an experimental demonstration at Oregon State University using liquid metal at 110 degrees C.

02 PETROLEUM↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Eight-ply (0, + or - 45, 0)s laminates of Hercules AS/3501-6 graphite epoxy composite are fabricated using various cure pressures ranging from 0.52 to 0.86 MPa and cure temperatures ranging from 150 C to 200 C. In general, the minimum composite void volume fraction is obtained at a cure temperature of 175 C and a cure pressure of 0.86 MPa, or at 200 C and 0.86 MPa. The ultrasonic attenuation at 4 MHz was found to correlate with the composite void volume fraction. Composite specimens were tested in flexural fatigue. Beyond 10,000 fatigue cycles, the ultrasonic attenuation at 4 MHz was found to increase and the flexural stiffness was found to decrease. The ultrasonic attenuation at 4 MHz of the as-fabricated composite can be correlated with the number of fatigue cycles to failure.

Williams, J. H., Jr.↗

Summary of nondestructive testing theory and practice

The ability to fabricate design critical and man-rated aerospace structures using materials near the limits of their capabilities requires a comprehensive and dependable assurance program. The quality assurance program must rely heavily on nondestructive testing methods for thorough inspection to assess properties and quality of hardware items. A survey of nondestructive testing methods is presented to provide space program managers, supervisors and engineers who are unfamiliar with this technical area with appropriate insight into the commonly accepted nondestructive testing methods available, their interrelationships, used, advantages and limitations. Primary emphasis is placed on the most common methods: liquid penetrant, magnetic particle, radiography, ultrasonics and eddy current. A number of the newer test techniques including thermal, acoustic emission, holography, microwaves, eddy-sonic and exo-electron emission, which are beginning to be used in applications of interest to NASA, are also discussed briefly.

Meister, R. P.↗

Correlation of the deply technique with the ultrasonic imaging of impact damage in graphite/epoxy composites

A quantitative ultrasonic technique for the nondestructive assessment of impact damage is described. The method, which involves digitizing the entire backscattered ultrasonic wave from a sample, was applied to two test panels removed from a 16-ply graphite/epoxy laminate and impacted with an aluminum ball fired at a velocity of 150 ft/sec. The results of the ultrasonic NDE were compared with the results obtained using the destructive deply technique of Freeman (1984). The NDE method provides through-the-thickness information on damage and only requires access to a single side of the material, while the deply technique gives exact information on the actual damage. Good quantitative agreement between the two techniques was obtained.

Smith, B. T.↗

TPSAS-NF1676L-11096-DND

A PRSEUS test article was subjected to controlled impact on the skin face followed by static and cyclic axial compressions. Phased array ultrasonic inspection was conducted before impact, and after each of the test conditions. A linear phased array probe with a manual X-Y scanner was used for interrogation. Ultrasound showed a delamination between the skin and stringer flange adjacent to the impact. As designed, the stitching in the flange arrested the lateral flaw formation. Subsequent ultrasonic data showed no delamination growth due to continued loading

Phased array↗

Novel Foaming Solutions for High Level Waste (HLW) Processing - 20195

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site's Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical offgas products [1]. The presence of amphiphilic particles in the waste slurry stabilizes the foam [2], [3]. Efficient processing of HLW requires foam control, as foam-overs lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Siovation Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. Despite its ability to control foam generation, processing issues have arisen from its use [4]. During DWPF chemical processing, a chemical antifoam agent must be effective at temperatures up to 103 deg. C between pH 3-13. Antifoam 747 is effective at pH 7 but degrades as pH deviates [5]. Antifoam 747 is 90% by weight Momentive{sup TM} L77 and 10% by weight Momentive{sup TM} Y-17580. These ingredients are trisiloxane products, which are especially vulnerable to attack in acidic and caustic environments. Since Antifoam 747 readily degrades, periodic addition is required. Several processing concerns related to Antifoam 747 have affected DWPF operation. Its overuse warranted concern of potential flammable melter offgas under upset conditions due to the generation of carbon dioxide and hydrogen. As a result, a Potential Inadequacy in the Safety Analysis (PISA) was declared [6]. Antifoam contribution has been included in the melter offgas flammability strategy and the quantity of antifoam is monitored to ensure limits are not exceeded. Testing at Savannah River National Laboratory (SRNL) determined that propanal, tri-methylsilanol, and hexamethyldisiloxane are generated as Antifoam 747 degrades, leading to a second PISA [7]. The formation of these byproducts poses additional flammability risks. Furthermore, the methyl and ethyl groups of these compounds may be responsible for the formation of the methyl and ethyl mercury discovered in DWPF [8], [9]. The formation of organomercury has specifically been called out by DOE as a need for increased research. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoam agents were evaluated as part of an effort to improve HLW treatment operations at DWPF and to reduce, or eliminate, the flammability hazards associated with Antifoam 747 currently in use. Foaming of high-level waste (HLW) slurries is an issue at the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) which is currently mitigated with a chemical antifoam agent. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoams were examined to improve HLW treatment at DWPF and to eliminate the flammability hazards associated with Siovation Antifoam 747 currently in use. Non-chemical foam control methods were deemed unviable for chemical processing at DWPF, as the spray/mist technique requires too much water and space limitations make installation and implementation of headspace agitators unfeasible. The use of ultrasonic energy thickened and further stabilized the foam. Two suitable alternative defoaming agents, Momentive{sup TM} Y- 17112 and Evonik Surfynol{sup R} MD-20, were identified. Both defoamers control foam over a pH range of 4- 13 at boiling, with no flammable degradation products, and only minimal quantities (100-200 mg/kg) are required under glycolic acid conditions. In order to validate the effectiveness of these defoaming agents, SRNL recommends irradiation testing and laboratory scale SRAT/SME experiments with actual radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Definition of defect size from ultrasonic inspection.

Attempt to obtain a set of relationships between testing parameters defining the range of defect size that can be associated with a given echo amplitude and defect depth. These relationships allow the user to find the largest defect that will return a signal equal to that from a flat hole of known diameter and depth, and the signal amplitude ratio between worst case and flat hole defects of equal diameter. The variation of the data with defect and testing parameters is shown. The results are obtained analytically, with laboratory corroboration, by calculation of the echo amplitude of the defect shape yielding the smallest return signal, a sphere, and the echo amplitude of the defect shape yielding the largest return signal, a flat hole.

Bennet, S. B.↗

Review of mechanical vibration tests conducted on control moment gyros and life test fixtures

Experimental vibration studies performed on a number of flight control moment gyros and bearing life test fixtures are summarized. Tests were performed at MSFC, at Wyle Laboratories, Huntsville, Alabama, and at the Bendix Corporation facilities in Teterboro, New Jersey. A description of test and analysis equipment is included as well as test procedures and overall performance rankings. Advanced ultrasonic rolling element bearing fault detection techniques were applied for bearing analysis along with conventional vibration and sound analysis procedures.

Burchill, R. F.↗

Ultrasonic-mammography apparatus

Improved transmitted/tissue/receiver coupling enhances sensitivity of mammography test. Device involves chamber into which organ is inserted or drawn by vacuum.

Buchea, O. C.↗

Characterization of constraint effects on flaw growth

Experimental results have been presented for the case of a flawed unidirectional lamina constrained by off-axis unflawed plies under static and fatigue loading. Flaw growth in the interior of the laminate, around the embedded flaw, was followed by nondestructive testing methods including video-thermographs and ultrasonic C-scan schemes. Two aspects of the results were distinctive. There was an effort of lamination on damage development which was independent of the presence of the notch, and effects which were directly related to the influence of the notch on the local situation. The results are compared with sectioning studies, surface replication, and stiffness change measurements.

Yeung, P. C.↗

NDE of simulated Space Shuttle tile disbonds

A technique which involves the use of ultrasonic Lamb waves for assaying the structural integrity of adhesive bonds between layered materials on thin metal plates, particularly with regard to the Shuttle TPS, is presented. The Lamb waves are generated by a pulse impact, resulting in surface waves propagating radially at 2.4 mm/microsec. Trials were performed with the sound waves applied to samples, of aluminum similar to the Orbiter external skin, which were coated with Teflon and a RTV silicone screed. The goal was to detect localized debonded areas or potentially debonded areas, which, during reentry, could result in blistering of the aluminum skin. The ultrasonic probes are described, noting the usage of broadband ultrasonic harmonics and a minicomputer processor. The testing system was found to accurately identify weakened bonds by the ratio of high and low frequency component areas of the received signal of the Lamb waves sent across the surface.

Ahlberg, L.↗

Ultra-Stable Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (5STAR)

The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with diffraction spectroscopy to improve knowledge of atmospheric constituents and their links to airpollution and climate. Direct beam hyperspectral measurement of optical depth improves retrievals of gas constituentsand determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution.Hyperspectral cloud-transmitted radiance measurements enable the retrieval of cloud properties from below clouds.These measurements tighten the closure between satellite and ground-based measurements. 4STAR incorporates amodular sun-tracking sky-scanning optical head with optical fiber signal transmission to rack mounted spectrometers,permitting miniaturization of the external optical tracking head, and future detector evolution.4STAR has supported a broad range of flight experiments since it was first flown in 2010. This experience provides thebasis for a series of improvements directed toward reducing measurement uncertainty and calibration complexity, andexpanding future measurement capabilities, to be incorporated into a new 5STAR instrument. A 9-channel photodioderadiometer with AERONET-matched bandpass filters will be incorporated to improve calibration stability. A wide dynamic range tracking camera will provide a high precision solar position tracking signal as well as an image of sky conditions around the solar axis. An ultrasonic window cleaning system design will be tested. A UV spectrometer tailored for formaldehyde and SO2 gas retrievals will be added to the spectrometer enclosure. Finally, expansion capability for a 4 channel polarized radiometer to measure the Stokes polarization vector of sky light will be incorporated. This paper presents initial progress on this next-generation 5STAR instrument.

atmosphere↗

Ultrasonic corona sensor study

The overall objective of this program is to determine the feasibility of using ultrasonic (above 20 kHz) corona detection techniques to detect low order (non-arcing) coronas in varying degrees of vacuum within large high vacuum test chambers, and to design, fabricate, and deliver a prototype ultrasonic corona sensor.

Harrold, R. T.↗