Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Behavior of Single-Line-Ground Faults in Inverter-Based Resource Dominated Grids Explained

It has been observed by protection engineers that it is difficult for a protective relay to identify the faulted phase during a single-line-ground (SLG) fault in a power system with a high ingression of inverter-based resources (IBR) using currents (phase or sequence). Further studies using electromagnetic transient (EMT) simulation show that the initial operating conditions of the IBRs influence the response of phase currents during an SLG fault. In this letter, we conduct a quantitative analysis using sequence components. We find that the pre-fault condition determines the relative position of the current contributed by the grid versus that from the IBR, and further dictates which phase has the largest magnitude during an SLG condition. Finally, this finding is further verified by the EMT simulation results.

electromagnetic transient simulation↗

EMT and Phasor-Domain Co-simulation of a Low Frequency AC Transmission System for Offshore Wind Integration

This work investigates system level interactions of multi-terminal low frequency high-voltage alternating current (LF-HVac) system using back-to back converters and grid-level 60 Hz system. A co-simulation framework by integrating high- fidelity dynamic model of multi-terminal LF-HVac system in electromagnetic transient (EMT) simulation platform and phasor model of IEEE 39 bus system in transient-stability (phasor) program. The co-simulation framework for multi-terminal LF- HVac system with offshore wind integrated in a bulk power system is developed successfully and its steady state and dynamic operation is demonstrated and compared with EMT simulation. The co-simulation results show accurate representation of the dynamic responses with reduced computation burden and time compared to EMT platform.

low-frequency transmission, co-simulation, electro↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

Accelerated Climate Model for Energy (ACME): Ocean and Sea-Ice Processes

The primary goal of this project was to understand the role of the ocean and sea-ice components in the evolution of the climate in both a high-resolution fully-coupled 1850 preindustrial control and present day transient climate simulations run using the Energy Exascale Earth System Model (E3SM), formerly known as the Accelerated Climate Model for Energy (ACME). Two distinct approaches to the initialization of the present day transients were tested: in the first, an ensemble of three transients used atmospheric reanalysis forced 0.1-degree ocean/sea-ice states, while a fourth transient was branched off the preindustrial control. Biases from the control were inherited by its successor transient, in particular, sea surface temperatures (SSTs) at high latitudes were too warm and too much northward meridional heat transport occurred in the North Atlantic Ocean. SSTs in the Northern Hemisphere and Atlantic meridional heat transport increased in the transients initialized from the ocean/sea-ice simulation over a 40-50 year period to largely resemble the transient branched off the control simulation. Excessive absorbed solar radiation (ASR) is considered to be responsible for the SST biases as well as the formation of mode waters in lighter density classes than in reality both in the Southern Ocean and the North Atlantic Ocean subtropical gyre. These mode waters ventilate the thermocline waters to the north of their formation sites explaining the excessive Atlantic meridional heat transport and some of the warming in the high-latitude North Atlantic Ocean after multiple decades.

54 ENVIRONMENTAL SCIENCES↗

Digital system upset. The effects of simulated lightning-induced transients on a general-purpose microprocessor

Flight critical computer based control systems designed for advanced aircraft must exhibit ultrareliable performance in lightning charged environments. Digital system upset can occur as a result of lightning induced electrical transients, and a methodology was developed to test specific digital systems for upset susceptibility. Initial upset data indicates that there are several distinct upset modes and that the occurrence of upset is related to the relative synchronization of the transient input with the processing sate of the digital system. A large upset test data base will aid in the formulation and verification of analytical upset reliability modeling techniques which are being developed.

Belcastro, C. M.↗

Magnetohydrodynamic simulation of the coronal transient associated with the solar limb flare of 1980, June 29, 18:21 UT

The spatial and temporal behavior of excess and depleted density regions of the coronal transient accompanying the west limb solar flare of 18:21 UT on June 29, 1980, is modeled mathematically on the basis of SMM-X-ray-polychrometer data, and the results are compared to observations made with the radio spectrograph at Harvard Radio Astronomy Station at Fort Davis and with the NCAR/HAO Mark III K-coronameter at Mauna Loa. Input data for the model include T(max) = about 20 x 10 to the 6th K, n(max) = about 4 x 10 to the 11th/cu cm, and an assumed ejection velocity of 200 km/sec. Computations using an improved 2D nonplane MHD model are carried out for locally open and closed magnetic topologies. The spatially wide, large-amplitude, temporarily steepened MHD wave predicted by the model for both magnetic topologies is shown to agree well with the observations, except that the predicted density enhancement exceeded observed values by at least 50 percent for the closed field and by a factor of 3 for the open field. This discrepancy is seen as an indication that the mass emitting soft X-rays was confined in closed-field regions near the sun during the obervation period.

Wu, S. T.↗

Developing a PSCAD Model of the Reduced 240-Bus WECC Test System: Preprint

Fast-acting controls of inverter-based resources (IBR) introduce unprecedented dynamics to bulk power systems and island power grids, especially the high-frequency dynamics ranging from $>5$ Hz to hundreds of Hz. These oscillatory stability problems cannot be captured by the phasor domain simulations, e.g., in PSS/E, Powerworld and TSAT, due to insufficient modeling. Instead, they should be studied by electromagnetic transient (EMT) simulations by using proper EMT dynamic models. This paper develops and validates the PSCAD model of the reduced 240-bus Western Electricity Coordinating Council (WECC) test system. The PSCAD model will be released to the public, which can be used by both academia and power industry practitioners for studying the fast dynamic problems without any Critical Energy/Electric Infrastructure Information (CEII).

240-bus WECC test system↗

Hybrid EMT-TS Simulation Strategies to Study High Bandwidth MMC-Based HVdc Systems

Modular multilevel converters (MMCs) are widely used in the design of modern high-voltage direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based HVdc system require small simulation time step and can be accurately modeled in electro-magnetic transient (EMT) simulation programs. The EMT program exhibits slow simulation speed and limitation on the size of the model and brings certain challenges to test the high-fidelity HVdc model in system-level simulations. This paper presents the design and implementation of a hybrid simulation framework, which enables the co-simulation of the EMT model of Atlanta-Orlando HVdc line and the transient stability (TS) model of the entire Eastern Interconnection system. This paper also introduces the implementation of two high-fidelity HVdc line models simulated at different time steps and discusses a dedicated method for sizing the buffer areas on both sides of the HVdc line. The simulation results of the two HVdc models with different sizes of buffer areas are presented and compared.

Liu, Yuan↗

Experiments in sensing transient rotational acceleration cues on a flight simulator

Results are presented for two transient motion sensing experiments which were motivated by the identification of an anomalous roll cue (a 'jerk' attributed to an acceleration spike) in a prior investigation of realistic fighter motion simulation. The experimental results suggest the consideration of several issues for motion washout and challenge current sensory system modeling efforts. Although no sensory modeling effort is made it is argued that such models must incorporate the ability to handle transient inputs of short duration (some of which are less than the accepted latency times for sensing), and must represent separate channels for rotational acceleration and velocity sensing.

Parrish, R. V.↗

Radiation-Induced Transient Effects in Near Infrared Focal Plane Arrays

This viewgraph presentation describes a test simulate the transient effects of cosmic ray impacts on near infrared focal plane arrays. The objectives of the test are to: 1) Characterize proton single events as function of energy and angle of incidence; 2) Measure charge spread (crosstalk) to adjacent pixels; 3) Assess transient recovery time.

Reed, Robert A.↗

Comparison of Electromagnetic Transient and Phasor-based Simulation for the Stability of Grid-Forming-Inverter-based Microgrids

The increasing interest in studying feeder-level, inverter-based microgrids requires appropriate simulation methods that can effectively simulate the dynamics of distribution feeders that typically have thousands of nodes. To examine the accuracy of phasor-based simulation for the stability of feeder-level, inverter-based microgrids, a comparative study between electromagnetic transient (EMT) and phasor-based simulation was conducted. Case studies of a two-inverter small microgrid and a modified version of the IEEE 34-Node Test System that has seven grid-forming inverters show that phasor-based simulation agrees well with EMT simulation when the P-f droop gains of grid-forming inverter controllers are within normal ranges. However, under extremely high P-f droop gains, phasor-based simulation can result in over-optimistic stability results. This study provides insight into the applicability of phasor-based simulation for the stability of feeder-level, inverter-based microgrids.

Du, Wei↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient thermoregulatory model with graphics output

A user's guide is presented for the transient version of the thermoregulatory model. The model is designed to simulate the transient response of the human thermoregulatory system to thermal inputs. The model consists of 41 compartments over which the terms of the heat balance are computed. The control mechanisms which are identified are sweating, vaso-constriction and vasodilation.

Grounds, D. J.↗

Mars atmospheric dynamics as simulated by the NASA Ames General Circulation Model. II - Transient baroclinic eddies

A large set of experiments performed with the NASA Ames Mars General Circulation Model is analyzed to determine the properties, structure, and dynamics of the simulated transient baroclinic eddies. There is strong transient baroclinic eddy activity in the extratropics of the Northern Hemisphere during the northern autumn, winter, and spring seasons. The eddy activity remains strong for very large dust loadings, though it shifts northward. The eastward propagating eddies are characterized by zonal wavenumbers of 1-4 and periods of about 2-10 days. The properties of the GCM baroclinic eddies in the northern extratropics are compared in detail with analogous properties inferred from Viking Lander meteorology observations.

Barnes, Jeffrey R.↗

Control Design and EMT Simulation Toward the Restoration of Faulted Wind-Dominant Grids

Present power engineers have been challenged to employ electromagnetic transient (EMT) simulations to study the restoration of wind-dominant grids. This paper addresses this hurdle by developing strategies to: (i) reliably control the dc-link voltage of grid-forming wind turbines with dc-coupled batteries, (ii) tune controllers to stably interconnect wind power plants into a grid under recovery, and (iii) autonomously make restoration decisions if transmission faults occur during restoration. These contributions are assessed via EMT simulations of wind-dominant versions of the WSCC 9-bus grid and a 22-bus power system. Furthermore, this paper is significant to address recommendations by the North American Electric Reliability Corporation.

17 WIND ENERGY↗

Numerical simulation of two-dimensional heat transfer in composite bodies with application to de-icing of aircraft components

Transient, numerical simulations of the de-icing of composite aircraft components by electrothermal heating were performed for a two dimensional rectangular geometry. The implicit Crank-Nicolson formulation was used to insure stability of the finite-difference heat conduction equations and the phase change in the ice layer was simulated using the Enthalpy method. The Gauss-Seidel point iterative method was used to solve the system of difference equations. Numerical solutions illustrating de-icer performance for various composite aircraft structures and environmental conditions are presented. Comparisons are made with previous studies. The simulation can also be used to solve a variety of other heat conduction problems involving composite bodies.

Chao, D. F. K.↗

One-dimensional transient finite difference model of an operational salinity gradient solar pond

This paper describes the modeling approach used to simulate the transient behavior of a salinity gradient solar pond. A system of finite difference equations are used to generate the time dependent temperature and salinity profiles within the pond. The stability of the pond, as determined by the capacity of the resulting salinity profile to suppress thermal convection within the primary gradient region of the pond, is continually monitored and when necessary adjustments are made to the thickness of the gradient zone. Results of the model are then compared to measurements taken during two representative seasonal periods at the University of Texas at El Paso's (UTEP's) research solar pond.

Hicks, Michael C.↗