RM3 Wave Tank Validation Model

An approximately 1/75th scale point absorber wave energy absorber was built to validate the testing systems of a 16k gallon single paddle wave tank. The model was build based on the RM3 design and incorporated a linear position sensor, a force transducer, and wetness detection sensors. The data set also includes motion tracking data of the device's two bodies acquired from 4x Qualisys cameras. The tank wave spectrum is measured by 4 ultrasonic water height sensors.

16 TIDAL AND WAVE POWER↗

Shale drilling field notes, lithologic descriptions, and core photographs of wells PLM5, PLM8, GUM1, and GLS1 at the East River Watershed, Colorado

The purpose of this dataset is to maintain a record of the shale drilling field notes, lithologic descriptions, and core photographs taken at the PLM5 (Pumphouse Lower Montane Borehole #5), PLM8 (Pumphouse Lower Montane Borehole #8), GUM1 (Gothic Upper Montane Borehole #1), and GLS1 (GLS1 = Gothic Lower Subalpine Borehole #1) wells at the East River Watershed, Colorado during October 2018 through November 2019. The wells were created as part of data collection for the Lawrence Berkeley National Laboratory Watershed Function Scientific Focus Area (WF SFA). This dataset consists of (1) detailed field notes and metadata (well locations, elevations, completion depths, and pressure transducer deployments) associated with drilling and coring activities accompanying the 2018 and 2019 installations of wells PLM5, PLM8, GUM1, and GLS1 and (2) high resolution photographs (*.png format) of all shale core recovered during the installations. Core photographs are labeled with location- and depth-specific names (e.g. PLM5_134-144ft), with the prefix (e.g. PLM5) indicating the well location and the suffix (e.g. 134-144ft) indicating the depth below ground surface of the recovered core. With the exception of core collected from well PLM5 from depths 0-59 feet, which were photographed by Tetsu Tokunaga in Berkeley, CA, all core was photographed by Kenneth H. Williams at the US Geological Survey core repository in Denver, Colorado, where all core samples are permanently archived.

54 ENVIRONMENTAL SCIENCES↗

Stream discharge and temperature data collected within the East and Taylor Watershed, Colorado for the Lawrence Berkeley National Laboratory Watershed Function Science Focus Area (water years 2019 to 2025)

This dataset contains stream discharge and temperature data for water years 2019 to 2025 from the East and Taylor Watersheds in Colorado, United States. This data was collected to understand hydrological processes occurring in the East River and Taylor River Watersheds, Colorado, which is part of the Lawrence Berkeley National Laboratory Watershed Function Scientific Focus Area. Data includes instantaneous observed discharge using salt dilution and acoustic doppler velocimeter techniques, raw pressure transducer downloaded data, sub-hourly temperature as well as corrected water level and associated stream discharge and mean daily values. Notes on water level corrections, rating curve development and metadata provided. A rating curve is the translation of depth to streamflow. The rating curve can be used as a quantitative measure of the “quality of the data.” Data within this dataset is formatted using ESS-DIVE’s Hydrological Monitoring Reporting Format. This data package contains (1) a zip file (Stream_Discharge_Data_WY19-WY25.zip) containing stream discharge and temperature data organized by location; (2) an InstallationMethods file (InstallationMethods.csv) describing metadata about the installation; (3) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; (4) a data dictionary (dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (5) a locations metadata file (locations.csv); (6) and a sensor metadata file (sensors.csv). All data files are in non-proprietary formats (csv, png, or pdf formats). Please contact Rosemary Carroll, Curtis Beutler, or Austin Shirley for any support in accessing the files. Update on 2023-05-12: Additional data from WYs 2021 and 2022 were added. Additionally, the dataset was converted using ESS-DIVE’s Hydrological Monitoring Reporting Format. Data files were reformatted to match reporting format guidance, new metadata files were added, and files were converted from excel to CSV. Update on 2025-05-16: Additional data from WYs 2022 (for locations not previously included), 2023, and 2024 were added. An additional descriptive PDF (WFSFA_Streamflow_Hydrograph_Disclaimer.pdf) was added. Metadata files were updated to reflect the addition of new data and locations. Update on 2026-05-18: Additional data from WY 2025 were added, including a new location Upper Trail Creek (TR-TCG2). Metadata files were updated to reflect the addition of new data.

54 ENVIRONMENTAL SCIENCES↗

Subsurface redox potential and water level at the Elkhorn Slough NERR

This resource contains various hydrological, and geochemical data from Elkhorn Slough National Estuarine Research Reserve from the years 2020 and 2021. These data have been used to assess how continuous measurements of environmental variables. The data can be used to understand processes at timescales over which biochemical transformations can happen. Especially, the data were used to explain the local subsurface hydrology, and its implication, in an experimental transect in a coasta estuary. Water level and water temperature were measured in-situ with Solinst pressure transducer loggers (Ontario, Canada). Redox potential was collected using in-situ, redox sensors (Paleoterra, The Netherlands) connected to CR1000X Campbell data loggers (Logan, Utah). Meteorological data was gathered from the Elkhorn Slough meteorological station.

54 ENVIRONMENTAL SCIENCES↗

QA/QC of the East River, Colorado, discharge and geochemical time series datasets (Almont, BCC, and Pump House) to be used for modeling of hydrogeochemical balance

The following datasets were QA/QC-ed (Quality Assurance/Quality Control): 1. Brush Creek Confluence (BCC) discharge data (from Helen Malenda, USGS, Colorado School of Mines), which were calculated using the pressure transducer data and rating curves. The original 15 min time series data were presented as mean daily discharge. 2. Almont discharge data from United States Geological Survey (USGS). The original data were in 15 min time intervals, and were averaged to mean daily discharge time series. 3. Pump House discharge data as mean daily discharge (downloaded from the SFA portal). 4. BCC and Pump House chemistry data from SFA data portal and/or original spreadsheets provided by Roelof Versteeg. The following challenging QA/QC problems of the datasets were resolved: Missing data with the duration of gaps up to >1 month; Duplicated dates; Anomalies and outliers of discharge and concentrations; Time stamps of measurements of the discharge and concentrations are not aligned (hydrogeochemical balance calculations require the timestamps to be aligned). All QA/QC-ed datasets are given as csv files. The csv files were prepared using the xts files with multiple worksheets, which are also included in the data packages. Figures of the QA/QC-ed datasets are given in the jpeg and pdf formats. The QA/QC-ed datasets have been used to quantify discharge and chemical concentrations in river water in order to understand riverine exports of water and dissolved constituents in the East River watershed. These datasets served as a basis in the presentation given by P. Fox et al. at the 2021 Goldschmidt Conference.

54 ENVIRONMENTAL SCIENCES↗

Monitoring of ground water table depth and soil moisture at the Point Reyes field site

Ground water table (GWT) depth and soil moisture (SM) have been monitored at several locations at the Point Reyes field site (Californian coastal grassland) from 2021 to 2024. Monitoring is still on-going and data may be added to this archive at later time. The SM data have been acquired using Teros 12 Meter soil moisture sensors placed at 10, 30, 60 and 90 cm depth at 5 locations along a small hillslope. These sensors also collect soil temperature and bulk conductance. In addition, some collocated sensors provide pore pressure and Photochemical Reflectance Index (PRI). The GWT depth has been inferred from various type of Onset pressure transducers. The pressure measurements have been corrected for atmospheric pressure variations and sensor position relative to the ground surface to infer GWT depth, as well as with RTK GPS data to infer GWT elevation. The GWT data have been acquired at 5 distinct locations from 2020 to 2024 with the sensors placed at about 4 m depth. In addition, GWT data has been acquired for the 2023-2024 period with sensors located in 1 m deep shallow wells installed near each deeper well. This data is intended to evaluate possibly different dynamic in shallow (perched) and deep aquifer. The datasets are all provided in csv format. Please note that the interpretation of the GWT data needs to be done with consideration of environmental and well characteristics at the site and uncertainty in various variables. For more information on GWT and SM data, please contact the author.

54 ENVIRONMENTAL SCIENCES↗

TASK3 Laboratory Experiments Data

Laboratory Experiments Data of TASK3 of DOE project DE- FE0031686. Each signal has its own excel file. 150 signals are sent through the rock sample per each load configuration. There were approximately 50 to 150 load combinations tested during the experiments. Experiments were repeated after changing the polarity direction of the transducers. Signals of these repeats are in separate folders called "Reverse". There are three formations tested from the Michigan Core and four formations tested from the FutureGen site. The "Code" folder contains the Python code developed to analyze the signals. Large Dataset, please contact EDXSupport@netl.doe.gov

core↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Accelerometer Drift Study

Accelerometers are energy transducers that convert mechanical energy into an electrical signal. That electrical signal is proportional to the amount of mechanical stress the accelerometer was subjected to. Knowing this proportionality allows the electrical signal to be interpreted as an acceleration. There are three types of sensing technologies utilized in capacitors: piezoelectric, piezoresistive and capacitive. In this study, all of the accelerometers utilized are of the piezoelectric type and purchased from one particular vendor, MEGGITT. The piezoelectric effect is the phenomena by which a material generates an electrical charge when subjected to a mechanical stress. A piezoelectric accelerometer will not generate an electrical charge when placed in a static acceleration field because no stress will be placed on the piezoelectric element. However if the acceleration field is dynamic, the piezoelectric element will generate an electrical charge. So the types of accelerations these accelerometers are measuring are dynamic in nature, such as vibrations. Knowledge of dynamic acceleration is useful in characterizing the structural response of some object. The sensitivity of an accelerometer is the ratio of its electrical output to mechanical input. The more sensitive an accelerometer is, the greater the value of the electrical output to a given mechanical input. An accelerometer’s sensitivity is known to drift over time. The objective of this study is to quantify this drift. Questions to answer are: Does the accelerometer become more or less sensitive over time and by how much. This is important to understand because this will establish a time frame of when readings from the accelerometer can be utilized. The larger this time frame is the better because that would preclude the need to purchase accelerometers frequently, which saves on costs. This would further bolster the relationship between MEGGITT and LANL if it is found that MEGGITT produces accelerometers that can be used for a relatively long period of time. This would create less uncertainty in picking a vendor for accelerometers.

42 ENGINEERING↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Shockwave Arrival Times from Operation Redwing and Operation Upshot-Knothole

Back in the 1940s, 50s, and 60s, 210 nuclear tests were conducted in the atmosphere. As part of the testing program, EG&G performed shockwave arrival-time measurements for different shots in different operations using pressure transducers at different distances from ground zero. They then developed correlations unique to each set of data. They did not attempt to correlate all data onto one curve. As a fireball moves, material is picked up and pulled in, which is called entrainment. This extra material increases the mass of the fireball, and as the energy is spread out over a larger and larger mass, the specific internal energy of the fireball gases drops, which causes the temperature to drop as well. When the energy in the solid angle of a spherical shockwave hits the surface, it is reflected. Shortly thereafter, it catches up with the outward-moving shockwave and re-combines with it, causing it to expand at a slightly faster rate. As the shockwave grows, it approaches a hemispherical shape. The purpose of this project is to demonstrate that the shockwave arrival-time data can, in fact, be correlated onto a single function when the shockwave time-dependent solution is modified to include a geometric factor, θ, and is corrected for an entrainment coefficient.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

“Mirror” magnet experiment for quench studies, quench analysis techniques development and in support of superconducting magnet modeling

In order to progress on various research points related to superconducting magnets, we suggest performing series of tests with induced and natural quenches on a mirror magnet, probably using a “11 T” coil. The “mirror” is to have voltage taps instrumented on half the strands, on both coil ends. It is to be instrumented with multiple spot-heaters, of the order of ten, in designated pole-turn areas. Instrumentation is to include quench antenna array facing the inner coil surface, as well as acoustic sensors on the inner layer pole. Further, acoustic sensors at the magnet ends and an acoustic calibration transducer are to be installed. Thus, we are to test sensitivity and precision of acoustic and quench antenna (QA) array sensors, both at close proximity to the coil, and we are to test and commission acoustic on-magnet real-time “calibration”. New or extended DAQ will be tested as well. In addition to diagnostic development, the purpose of the magnet experiment is to investigate current redistribution in the coil, both during quenching and in operating conditions; to assess voltage build up across strands and in the coil segments during quenching, to explore voltage signature differentiation between different type of quenches; to improve modeling of processes during quenching and for magnet design purposes. In this experiment, we expect to be able to characterize the processes during a quench in unprecedented details.

43 PARTICLE ACCELERATORS↗

Simulations of SITI Cookoff Experiments Carried Out with Different Lots of PBX 9502

A pressure dependent cookoff model for PBX 9502 was developed by Hobbs’ et. al. PBX 9502 is composed of 95% by mass triaminotrinitrobenzene (TATB) and a 5% by mass chlorotrifluoroethylene/vinylidine fluoride binder. The objective in this study is to implement this cookoff model in Aria to simulate Sandia Instrumented Thermal Ignition (SITI) experiments that were carried out with different manufacturing lots of PBX 9502. The SITI design consists of solid cylinders (1" diameter × 1" height) of insensitive high explosive (IHE) confined by a cylindrical aluminum case. An electric heater is wrapped around the lateral surface of the case. This heater produces a temperature heating ramp on the outer surface of the case. Internal thermocouples measure the IHE temperature rise from the center to locations close to the IHE-aluminum interface. The energetic material is heated until thermal ignition occurs. Pressure is measured with a static pressure transducer installed on top of the confinement case. Two–dimensional axisymmetric heat conduction finite element models were implemented to simulate these experiments using four options of the PBX 9502 cookoff model. In addition, the predictive ability of this thermal decomposition model is evaluated using Latin Hypercube Sampling (LHS) techniques.

42 ENGINEERING↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Brine Availability Test in Salt (BATS) FY21 Update

This report summarizes the 2021 fiscal year (FY21) status of ongoing borehole heater tests in salt funded by the disposal research and development (R&D) program of the Office of Spent Fuel & Waste Science and Technology (SFWST) of the US Department of Energy’s Office of Nuclear Energy’s (DOE-NE) Office of Spent Fuel and Waste Disposition (SFWD). This report satisfies SFWST milestone M2SF- 21SN010303052 by summarizing test activities and data collected during FY21. The Brine Availability Test in Salt (BATS) is fielded in a pair of similar arrays of horizontal boreholes in an experimental area at the Waste Isolation Pilot Plant (WIPP). One array is heated, the other unheated. Each array consists of 14 boreholes, including a central borehole with gas circulation to measure water production, a cement seal exposure test, thermocouples to measure temperature, electrodes to infer resistivity, a packer-isolated borehole to add tracers, fiber optics to measure temperature and strain, and piezoelectric transducers to measure acoustic emissions. The key new data collected during FY21 include a series of gas tracer tests (BATS phase 1b), a pair of liquid tracer tests (BATS phase 1c), and data collected under ambient conditions (including a period with limited access due to the ongoing pandemic) since BATS phase 1a in 2020. A comparison of heated and unheated gas tracer test results clearly shows a decrease in permeability of the salt upon heating (i.e., thermal expansion closes fractures, which reduces permeability).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Guidance on Use of the Linseis Vertical Dilatometer L75

Linseis vertical Dilatometer L75 thermal expansion equipment is a complete system which can be used for measuring change of the absolute length of a sample, determination of the thermal expansion coefficient (CTE), shrinkage, and sintering. The 238 Pu Supply Program is interested in re-establishing the capability to determine CTE and measuring the change of the absolute length of various 237 Np Al/cermet samples during heating. The change in length of the measured sample is recorded using a highly sensitive Linear Variable Differential Transformer (LVDT). The dilatometer is user-friendly and simple to operate which will allow technicians to be trained easily on its use. This equipment was designed to be used specifically for ceramics. It has a highly vacuum tight push rod dilatometer, a high-resolution inductive transducer using innovative and comprehensive temperature controls which provide excellent performance as a measurement system yielding high accuracy, reproducibility, and long-term stability.

07 ISOTOPE AND RADIATION SOURCES↗

A MEMS Gyroscope for Reliable Long Duration Measurement While Drilling at 300°C

The 300°C Microelectromechanical system (MEMS) gyroscope project aims to contribute to DOE’s goal of increased geothermal drilling efficiency by 2025 through the development of a 300°C MEMS gyroscope for Measurement While Drilling (MWD). At the conclusion of the 2-year project, the team will develop a 300°C capable MEMS gyroscope containing GE’s patented Multi-Ring Gyroscope Transducer (MRGT) design, custom Silicon-On-Insulator (SOI) based frontend and feedback control electronics, and with demonstrated functionality and lifetime beyond 1000 hours. The project is divided into two budget periods with Go/No-Go decision at the end of the first budget period. The goal for the first budget period is to establish the feasibility of the MRGT and electronics design for meeting the 300°C performance requirements. The goal for the second budget period is to integrate the MRGT with the SOI-based application specific integrated circuit (ASIC) and demonstrate capability to operate at 300°C for 1000 hours. In Budget Period 1 we met the phase 1 goal. We successfully validated the combined MRG, electronics and packaging capability entitlement to achieving 0.5 degrees azimuth uncertainty while enabling operation at significantly higher temperatures than the state-of-the-art. In Budget Period 2, we successfully completed the integration of the MRGT and ASIC with associated high temperature, high reliability packaging to demonstrate the performance and functionality of the integrated gyroscope across the temperature range from room temperature to at 300°C. Furthermore, the team demonstrated operating life of >1,000 hours at 300°C, thus providing a validation of application-relevant lifetime capability.

15 GEOTHERMAL ENERGY↗

Niowave: Flow measurement development - FY2022

It is critical to maintain proper flow rate of lead bismuth eutectic (LBE) for the operation of the Niowave converter. The high temperature of the LBE (> 200 °C) makes it difficult to purchase simple off the shelf flow meters. One method that can be used to measure the flow rate indirectly, is to use a venturi, with a known throat diameter and differential pressure measurement across the throat. LANL designed the venturi and after numerous iterations with vendors, narrowed down a differential pressure transducer to use with the venturi.