Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Flutter spectral measurements using stationary pressure transducers

Engine-order sampling was used to eliminate the integral harmonics from the flutter spectra corresponding to a case-mounted static pressure transducer. Using the optical displacement data, it was demonstrated that the blade-order sampling of pressure data may yield erroneous results due to the interference caused by blade vibration. Two methods are presented which effectively eliminate this interference yielding the blade-pressure-difference spectra. The phase difference between the differential-pressure and the displacement spectra was evaluated.

Kurkov, A. P.↗

Digital ultrasonic signal processing: Primary ultrasonics task and transducer characterization use and detailed description

This manual describes the use of the primary ultrasonics task (PUT) and the transducer characterization system (XC) for the collection, processing, and recording of data received from a pulse-echo ultrasonic system. Both PUT and XC include five primary functions common to many real-time data acquisition systems. Some of these functions are implemented using the same code in both systems. The solicitation and acceptance of operator control input is emphasized. Those operations not under user control are explained.

Hammond, P. L.↗

Solar cell angular position transducer

An angular position transducer utilizing photocells and a light source is disclosed. The device uses a fully rotatable baffle which is connected via an actuator shaft to the body whose rotational displacement is to be measured. The baffle blocks the light path between the light source and the photocells so that a constant semicircular beam of light reaches the photocells. The current produced by the photocells is fed through a resistor, a differential amplifier measures the voltage drop across the resistor which indicates the angular position of the actuator shaft and hence of the object.

Sandford, M. C.↗

Flutter spectral measurements using stationary pressure transducers

The paper deals with an analysis procedure, based on engine-order sampling, which eliminates effectively the engine harmonics from the overall flutter spectra obtained with a case-mounted static pressure transducer. Qualitative spectral analyses of pressure data, performed on the basis of blade order sampling, are examined. The interference of blade motion with the pressure signal in the steep gradient portion of the blade passage is demonstrated, using optimal displacement spectra. Two methods which remove the contribution of blade motion from the blade-pressure-difference spectra are described.

Kurkov, A. P.↗

Ultrasonic Transducer Analyzer

Ultrasonic transducer-beam-intensity distributions are determined by analyzing echoes from a spherical ball. Computers control equipment and process data. Important beam characteristics, such as location of best beam focus and beam diameter at focus, can be determined quickly from extensive set of plots generated by apparatus.

Grounds, M. K.↗

Low current linearization of magnetic amplifier for dc transducer

A magnetic amplifier having two saturable reactor cores with a separate excitation winding on each connected in series opposition, a common control winding, and a common output winding, is adapted for use as a low level signal transducer. The separate excitation windings are excited in push-pull mode through a center tapped transformer, and at least one diode is included in series with a load resistor connected to the output winding. A resistor in series with the output winding and load resistor is connected between the center tap of the excitation transformer and the connection between the two excitation windings of the saturable cores. This series resistor provides a return current path for the output winding and allows the excitation windings of the saturable cores to operate as primary windings of transformers.

Nagano, S.↗

Ultrasonic imaging using trapped energy mode Fresnel lens transducers

Trapped-energy focusing transducers operating in the 2-5 MHz range have been fabricated by plating concentric rings of electrodes on a piezoelectric plate. The concentric ring structure acts as a Fresnel lens and can be used to obtain excellent lateral focusing of ultrasonic waves. The trapping is sufficiently strong to permit optimization of electrode spacings to suppress spurious virtual foci and ring sidelobes.

Das, P.↗

Transducer System Traces Mine-Face Curve

Electromechanical system capable of obtaining contour information on longwall coal face while longwall shearer mines coal. Two heavy-duty angle transducers 2.5 feet apart are attached to common reference surface and operate in conjunction with distance encode to measure angle between adjacent track sections along coal face.

Source record↗

Liquid-immersible electrostatic ultrasonic transducer

A broadband megahertz range electrostatic acoustic transducer for use in a liquid environment is described. A liquid tight enclosure includes a metallic conducting membrane as part of its outside surface and has a means inside the liquid tight enclosure for applying a tension to the membrane and for mounting an electrode such that the flat end of the electrode is aproximately parallel to the membrane. The invention includes structure and a method for ensuring that the membrane and the flat end of the electrode are exactly parallel and a fixed predetermined distance from each other.

Cantrell, J. H., Jr.↗

Transducer Joint for Kidney-Stone Ultrasonics

Ultrasonic therapy for kidney stones improved by new way of connecting wire-probe ultrasonic waveguide to transducer. Improved mounting allows joint to last long enough for effective treatment. Sheath and rubber dampers constrain lateral vibration of wire waveguide. Combination of V-shaped mounting groove, sheath, and rubber dampers increases life expectancy of wire 15 times or more.

Angulo, E. D.↗

Polyamine formation by arginine decarboxylase as a transducer of hormonal, environmental and stress stimuli in higher plants

Recent evidence implicates polyamines including putrescine in the regulation of such diverse plant processes as cell division, embryogenesis and senescence. We find that the enzyme arginine decarboxylase, which controls the rate of putrescine formation in some plant systems, is activated by light acting through P(r) phytochrome as a receptor, by the plant hormone gibberellic acid, by osmotic shock and by other stress stimuli. We therefore propose arginine decarboxylase as a possible transducer of the various initially received tropistic stimuli in plants. The putrescine formed could act by affecting cytoskeletal components.

Galston, A. W.↗

Pulsed-Current Transducers

Diode circuit linearizes output of pulsating dc tranducers. Circuit consists of diode in series with sensing resistor placed across secondary winding of transducer transformer.

Nagano, S. S.↗

Dynamic Calibration of Pressure Transducers

Sinusoidal calibration signal produced in 4- to 100-Hz range. Portable oscillating-pressure device measures dynamic characteristics of pressure transducers installed in models or aircraft at frequency and oscillating-pressure ranges encountered during unsteady-pressure-measurement tests. Calibration is over range of frequencies and amplitudes not available with commercial acoustic calibration devices.

Hess, R. W.↗

Ultrasonic transducer with Gaussian radial pressure distribution

An ultrasonic transducer that produces an output that is a symmetrical function comprises a piezoelectric crystal with several concentric ring electrodes on one side of the crystal. A resistor network applies different amplitudes of an ac source to each of the several electrodes. A plot of the different amplitudes from the outermost electrode to the innermost electrode is the first half of a Gaussian function. Consequently, the output of the crystal from the side opposite the electrodes has a Gaussian profile.

Claus, R. O.↗

Thin film strain transducer

A strain transducer system and process for making the same is disclosed. A beryllium copper ring having four strain gages is electrically connected in Wheatstone bridge fashion to the output instrumentation. Tabs are bonded to a balloon or like surface with strain on the surface causing bending of a ring which provides an electrical signal through the gages proportional to the surface strain. A photographic pattern of a one half ring segment as placed on a sheet of beryllium copper for chem-mill etch formation is illustrated.

Rand, J. L.↗

Shaft transducer having dc output proportional to angular velocity

A brushless dc tachometer is disclosed that includes a high strength toroidal permanent magnet for providing a uniform magnetic field in an air gap, an annular pole piece opposite the magnet, and a pickup coil wound around the pole piece and adapted to rotate about the axis of the pole piece. The pickup coil is rotated by an input shaft to which the coil is coupled with the friction clip. The output of the coil is conducted to circuitry by a twisted wire pair. The input shaft also activates a position transducing potentiometer.

Handlykken, M. B.↗

Fixture for Linearly Variable Displacement Transducers

Original point of interest on shear panel tracked throughout loading. Technique and fixture measure out-of-plane displacements on shear panel using linearly variable displacement transducers (LVDT's) while tracking original panel location. Technique adaptable to any size shear panel.

Farley, G. L.↗