Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Chapter 6: CPV Tracking and Trackers

This chapter explains the functional requirements of a concentrator photovoltaic (CPV) sun tracker. It derives the design specifications of a CPV tracker. The chapter presents taxonomy of trackers describing the most common tracking architectures, based on the number of axes, their relative position, and the foundation and placing of tracking drives. It deals with the structural issues related to tracker design, mainly related to structural flexure and its impact on the system's acceptance angle. The chapter analyzes the auto-calibrated sun tracking control, by describing the state of the art and its development background. It explores the sun tracking accuracy measurement with a practical example. The chapter discusses tracker manufacturing and tracker field works. It reviews survey of different types of tracker designs obtained from different manufacturers. Finally, the chapter deals with IEC62817, the technical standard developed for CPV sun trackers.

14 SOLAR ENERGY↗

Optimizing trigger-level track reconstruction for sensitivity to exotic signatures

Many compelling beyond the Standard Model scenarios predict signals that result in unconventional charged particle trajectories. Signatures for which unusual tracks are the most conspicuous feature of the event pose significant challenges for experiments at the Large Hadron Collider (LHC), particularly for the trigger. This article presents a study of track-based triggers for a representative set of long-lived and unconventional signatures at the upcoming High Luminosity LHC, as well as resulting recommendations for the target parameters of a hardware-based tracking system. Scenarios studied include large multiplicities of low-p T tracks produced in a soft-unclustered-energy-pattern model, displaced leptons and anomalous prompt tracks predicted in a Supersymmetry model with long-lived staus, and displaced hadrons predicted in a Higgs portal scenario with long-lived scalars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files

Purpose: To quantify the clinical accuracy of the respiratory motion tracking system of the CyberKnife treatment device. Methods and Materials: Data in log files of 44 lung cancer patients treated with tumor tracking were analyzed. Errors in the correlation model, which relates the internal target motion with the external breathing motion, were quantified. The correlation model error was compared with the geometric error obtained when no respiratory tracking was used. Errors in the prediction method were calculated by subtracting the predicted position from the actual measured position after 192.5 ms (the time lag to prediction in our current system). The prediction error was also measured for a time lag of 115 ms and a new prediction method. Results: The mean correlation model errors were less than 0.3 mm. Standard deviations describing intrafraction variations around the whole-fraction mean error were 0.2 to 1.9 mm for cranio-caudal, 0.1 to 1.9 mm for left-right, and 0.2 to 2.5 mm for anterior-posterior directions. Without the use of respiratory tracking, these variations would have been 0.2 to 8.1 mm, 0.2 to 5.5 mm, and 0.2 to 4.4 mm. The overall mean prediction error was small (0.0 {+-} 0.0 mm) for all directions. The intrafraction standard deviation ranged from 0.0 to 2.9 mm for a time delay of 192.5 ms but was halved by using the new prediction method. Conclusions: Analyses of the log files of real clinical cases have shown that the geometric error caused by respiratory motion is substantially reduced by the application of respiratory motion tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility Study for Markerless Tracking of Lung Tumors in Stereotactic Body Radiotherapy

Purpose: To evaluate the feasibility and accuracy of a method for markerless tracking of lung tumors in electronic portal imaging device (EPID) movies and to analyze intra- and interfractional variations in tumor motion. Methods and Materials: EPID movies were acquired during stereotactic body radiotherapy (SBRT) given to 40 patients with 49 pulmonary targets and retrospectively analyzed. Tumor visibility and tracking accuracy were determined by three observers. Tumor motion of 30 targets was analyzed in detail via four-dimensional computed tomography (4DCT) and EPID in the superior-inferior direction for intra- and interfractional variations. Results: Tumor visibility was sufficient for markerless tracking in 47% of the EPID movies. Tumor size and visibility in the DRR were correlated with visibility in the EPID images. The difference between automatic and manual tracking was a maximum of 2 mm for 98.3% in the x direction and 89.4% in the y direction. Motion amplitudes in 4DCT images (range, 0.7-17.9 mm; median, 4.9 mm) were closely correlated with amplitudes in the EPID movies. Intrafractional and interfractional variability of tumor motion amplitude were of similar magnitude: 1 mm on average to a maximum of 4 mm. A change in moving average of more than {+-}1 mm, {+-}2 mm, and {+-}4 mm were observed in 47.1%, 17.1%, and 4.5% of treatment time for all trajectories, respectively. Mean tumor velocity was 3.4 mm/sec, to a maximum 61 mm/sec. Conclusions: Tracking of pulmonary tumors in EPID images without implanted markers was feasible in 47% of all treatment beams. 4DCT is representative of the evaluation of mean breathing motion on average, but larger deviations occurred in target motion between treatment planning and delivery effort a monitoring during delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear Accelerator

Purpose: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. Methods and Materials: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Goettingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error {Sigma} and the random error {sigma} were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. Results: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, {Sigma} was 0.5 mm/0.4 mm in the two imager directions, whereas {sigma} was 0.5 mm/1.1 mm. Without tracking, {Sigma} and {sigma} would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. Conclusion: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy. The study mimicked the envisioned patient workflow of future patient treatments. Clinical implementation of MV image-based tracking would require markers designed for MV visibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended live-tracking and quantitative characterization of wound healing and cell migration with SiR-Hoechst

Highlights: • SiR-Hoechst is a nuclear dye that enables cell tracking without affecting migration. • Single cell analysis provides multiple migration metrics during wound healing. • Cell density-based report of wound healing is less susceptible to subjective bias. • Cell directionality is an important contributor of early wound recovery. Cell migration is essential to many life processes, including immune response, tissue repair, and cancer progression. A reliable quantitative characterization of the cell migration can therefore aid in the high throughput screening of drug efficacy in wound healing and cancer treatments. In this work, we report what we believe is the first use of SiR-Hoechst for extended live tracking and automated analysis of cell migration and wound healing. We showed through rigorous statistical comparisons that this far-red label does not affect migratory behavior. We observed excellent automated tracking of random cell migration, in which the motility parameters (speed, displacement, path length, directionality ratio, persistence time, and direction autocorrelation) obtained closely match those obtained from manual tracking. We also present an analysis framework to characterize the healing of a scratch wound from the perspective of single cells. The use of SiR-Hoechst is advantageous for the crowded environments in wound healing assays because as long as cell nuclei do not overlap, continuous tracking can be maintained even if there is cell-cell contact. In this paper, we report wound recovery based on the number of cells migrating into the wound over time, normalized by the initial cell count prior to the infliction of the wound. This normalized cell count approach is impervious to operator bias during the arbitration of wound edges and is also robust against variability that arises due to differences in the cell density of different samples. Additional wound healing characteristics were also defined based on the evolution of cell speed and directionality during healing. Not unexpected, the wound healing cells exhibited much higher tendency to maintain the same migratory direction in comparison to the randomly migrating cells. The use of SiR-Hoechst thus greatly simplified the automation of single cell and whole population analysis with high spatial and temporal resolution over extended periods of time.

60 APPLIED LIFE SCIENCES↗

Unveiling Swift Heavy Ion Track Morphology in Sr-Based High-Entropy Perovskites

The incorporation of multiple cations on a single lattice site in the high-entropy oxides is considered the key driving factor for modifying the known atomic-level response to energetic ion irradiation due to the presence of structural disorder; however, these effects are not well-understood yet. In this work, we present atomic-level insight into irradiation-induced nanoscale phase transformations in a perovskite-structured high-entropy oxide, Sr(Zr 0.2 Sn 0.2 Ti 0.2 Hf 0.2 Nb 0.2 )O 3 (Sr(HE)O 3 ), subjected to 774 MeV swift Xe heavy ions, where damage is dominated by inelastic ion−lattice interactions. While these ions generally are known to create nanoscale disordered channels, “ion tracks”, along the penetration direction in the material, this study shows the formation of discontinuous and partially recrystallized ion tracks in Sr(HE)O 3 . Compared to SrTiO 3 irradiated under identical energy loss conditions, the ion tracks in Sr(HE)O 3 exhibit significantly reduced diameters and a markedly different interfacial structure. Notably, the crystalline−amorphous interface in Sr(HE)O 3 shows minimal lattice distortion, confined to approximately 2−3 monolayers, in contrast to the extended disordered shell commonly observed in SrTiO 3 . Using in situ atomic-resolution electron microscopy, we further demonstrate that the amorphous/disordered regions within Sr(HE)O 3 ion tracks remain highly stable under electron irradiation, whereas tracks in SrTiO 3 readily recrystallize. This enhanced stability is attributed to the dominance of structural and chemical complexity arising from multiple B-site cations, which suppress defect migration and templated recrystallization driven by electronic excitations and local heating. Overall, this study highlights how high-entropy oxide chemistry fundamentally reshapes irradiation damage evolution, offering insights into defect formation and phase stability under extreme conditions.

36 MATERIALS SCIENCE↗

Weakening of the Extratropical Storm Tracks in Solar Geoengineering Scenarios

Solar geoengineering that aims to offset global warming could nonetheless alter atmospheric temperature gradients and humidity and thus affect the extratropical storm tracks. Here, we first analyze climate model simulations from experiment G1 of the Geoengineering Model Intercomparison Project, in which a reduction in incoming solar radiation balances a quadrupling of CO 2 . The Northern Hemisphere extratropical storm track weakens by a comparable amount in G1 as it does for increased CO2 only. The Southern Hemisphere storm track also weakens in G1, in contrast to a strengthening and poleward shift for increased CO 2 . Using mean available potential energy, we show that the changes in zonal-mean temperature and humidity are sufficient to explain the different responses of storm-track intensity. We also demonstrate similar weakening in a more complex geoengineering scenario. Here, our results offer insight into how geoengineering affects storm tracks, highlighting the potential for geoengineering to induce novel climate changes.

54 ENVIRONMENTAL SCIENCES↗

Tracking single particle rotation: Probing dynamics in four dimensions

Direct visualization and tracking of small particles at high spatial and temporal resolution provides a powerful approach to probing complex dynamics and interactions in chemical and biological processes. Analysis of the rotational dynamics of particles adds a new dimension of information that is otherwise impossible to obtain with conventional 3-D particle tracking. In this review, we survey recent advances in single-particle rotational tracking, with highlights on the rotational tracking of optically anisotropic Janus particles. Furthermore, strengths and weaknesses of the various particle tracking methods, and their applications are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallelized Kalman-Filter-Based Reconstruction of Particle Tracks on Many-Core Processors and GPUs

For over a decade now, physical and energy constraints have limited clock speed improvements in commodity microprocessors. Instead, chipmakers have been pushed into producing lower-power, multi-core processors such as Graphical Processing Units (GPU), ARM CPUs, and Intel MICs. Broad-based efforts from manufacturers and developers have been devoted to making these processors user-friendly enough to perform general computations. However, extracting performance from a larger number of cores, as well as specialized vector or SIMD units, requires special care in algorithm design and code optimization. One of the most computationally challenging problems in high-energy particle experiments is finding and fitting the charged-particle tracks during event reconstruction. This is expected to become by far the dominant problem at the High-Luminosity Large Hadron Collider (HL-LHC), for example. Today the most common track finding methods are those based on the Kalman filter. Experience with Kalman techniques on real tracking detector systems has shown that they are robust and provide high physics performance. This is why they are currently in use at the LHC, both in the trigger and offine. Previously we reported on the significant parallel speedups that resulted from our investigations to adapt Kalman filters to track fitting and track building on Intel Xeon and Xeon Phi. Here, we discuss our progresses toward the understanding of these processors and the new developments to port the Kalman filter to NVIDIA GPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking shocked dust: State estimation for a complex plasma during a shock wave

We consider a two-dimensional complex (dusty) plasma crystal excited by an electrostatically-induced shock wave. Dust particle kinematics in such a system are usually determined using particle tracking velocimetry. In this work we present a particle tracking algorithm which determines the dust particle kinematics with significantly higher accuracy than particle tracking velocimetry. The algorithm uses multiple extended Kalman filters to estimate the particle states and an interacting multiple model to assign probabilities to the different filters. This enables the determination of relevant physical properties of the dust, such as kinetic energy and kinetic temperature, with high precision. We use a Hugoniot shock-jump relation to calculate a pressure-volume diagram from the shocked dust kinematics. Calculation of the full pressure-volume diagram was possible with our tracking algorithm, but not with particle tracking velocimetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local characterization of hindered Brownian motion by using digital video microscopy and 3D particle tracking

In this article we present methods for measuring hindered Brownian motion in the confinement of complex 3D geometries using digital video microscopy. Here we discuss essential features of automated 3D particle tracking as well as diffusion data analysis. By introducing local mean squared displacement-vs-time curves, we are able to simultaneously measure the spatial dependence of diffusion coefficients, tracking accuracies and drift velocities. Such local measurements allow a more detailed and appropriate description of strongly heterogeneous systems as opposed to global measurements. Finite size effects of the tracking region on measuring mean squared displacements are also discussed. The use of these methods was crucial for the measurement of the diffusive behavior of spherical polystyrene particles (505 nm diameter) in a microfluidic chip. The particles explored an array of parallel channels with different cross sections as well as the bulk reservoirs. For this experiment we present the measurement of local tracking accuracies in all three axial directions as well as the diffusivity parallel to the channel axis while we observed no significant flow but purely Brownian motion. Finally, the presented algorithm is suitable also for tracking of fluorescently labeled particles and particles driven by an external force, e.g., electrokinetic or dielectrophoretic forces.

74 ATOMIC AND MOLECULAR PHYSICS↗

SIZE AND DENSITY ESTIMATION FROM IMPACT TRACK MORPHOLOGY IN SILICA AEROGEL: APPLICATION TO DUST FROM COMET 81P/WILD 2

A large number of cometary dust particles were captured with low-density silica aerogel during the NASA Stardust mission. The dust particles penetrated into the aerogel and formed various track shapes. To estimate the properties of the dust particles, such as density and size, based on the morphology of the tracks, we carried out systematic experiments testing impacts into low-density aerogel at 6 km s{sup -1} using projectiles of various sizes and densities. We found that the maximum track diameter and the ratio of the track length to the maximum track diameter in aerogel are good indicators of projectile size and density, respectively. Based on these results, we estimated the size and density of individual dust particles from comet 81P/Wild 2. The average density of the 'fluffy' dust particles and the bulk density of all dust particles were obtained as 0.35 {+-} 0.07 and 0.49 {+-} 0.18 g cm{sup -3}, respectively. These statistical data provided the content of monolithic and coarse grains in the Stardust particles, {approx}30 wt%. Combining this result with some mid-infrared observational data, we found that the content of crystalline silicates is {approx}50 wt% or more of non-volatile material.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional track reconstruction for directional Dark Matter detection

Directional detection of Dark Matter is a promising search strategy. However, to perform such detection, a given set of parameters has to be retrieved from the recoiling tracks: direction, sense and position in the detector volume. In order to optimize the track reconstruction and to fully exploit the data of forthcoming directional detectors, we present a likelihood method dedicated to 3D track reconstruction. This new analysis method is applied to the MIMAC detector. It requires a full simulation of track measurements in order to compare real tracks to simulated ones. We conclude that a good spatial resolution can be achieved, i.e. sub-mm in the anode plane and cm along the drift axis. This opens the possibility to perform a fiducialization of directional detectors. The angular resolution is shown to range between 20° to 80°, depending on the recoil energy, which is however enough to achieve a high significance discovery of Dark Matter. On the contrary, we show that sense recognition capability of directional detectors depends strongly on the recoil energy and the drift distance, with small efficiency values (50%–70%). We suggest not to consider this information either for exclusion or discovery of Dark Matter for recoils below 100 keV and then to focus on axial directional data.

79 ASTRONOMY AND ASTROPHYSICS↗

Test beam demonstration of silicon microstrip modules with transverse momentum discrimination for the future CMS tracking detector

A new CMS Tracker is under development for operation at the High Luminosity LHC from 2026 onwards. It includes an outer tracker based on dedicated modules that will reconstruct short track segments, called stubs, using spatially coincident clusters in two closely spaced silicon sensor layers. These modules allow the rejection of low transverse momentum track hits and reduce the data volume before transmission to the first level trigger. The inclusion of tracking information in the trigger decision is essential to limit the first level trigger accept rate. A customized front-end readout chip, the CMS Binary Chip (CBC), containing stub finding logic has been designed for this purpose. A prototype module, equipped with the CBC chip, has been constructed and operated for the first time in a 4 GeemVem/emc positron beam at DESY. The behaviour of the stub finding was studied for different angles of beam incidence on a module, which allows an estimate of the sensitivity to transverse momentum within the future CMS detector. A sharp transverse momentum threshold around 2 emVem/emc was demonstrated, which meets the requirement to reject a large fraction of low momentum tracks present in the LHC environment on-detector. This is the first realistic demonstration of a silicon tracking module that is able to select data, based on the particle's transverse momentum, for use in a first level trigger at the LHC . The results from this test are described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

Track reconstruction as a service for collider physics

Optimizing charged-particle track reconstruction algorithms is crucial for efficient event reconstruction in Large Hadron Collider (LHC) experiments due to their significant computational demands. Existing track reconstruction algorithms have been adapted to run on massively parallel coprocessors, such as graphics processing units (GPUs), to reduce processing time. Nevertheless, challenges remain in fully harnessing the computational capacity of coprocessors in a scalable and non-disruptive manner. This paper proposes an inference-as-a-service approach for particle tracking in high energy physics experiments. To evaluate the efficacy of this approach, two distinct tracking algorithms are tested: Patatrack, a rule-based algorithm, and Exa.TrkX, a machine learning-based algorithm. The as-a-service implementations show enhanced GPU utilization and can process requests from multiple CPU cores concurrently without increasing per-request latency. The impact of data transfer is minimal and insignificant compared to running on local coprocessors. This approach greatly improves the computational efficiency of charged particle tracking, providing a solution to the computing challenges anticipated in the High-Luminosity LHC era.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗