Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Satellite thermal modeling using the illuminographic camera

The application is discussed of illuminographic camera techniques to the measurement of radiative form factors for satellite modeling applications. The equation for the illuminographic mirror is derived, and the advantages of the method are discussed. Proximity error for the illuminographic mirror is defined, and estimates of this error as a function of the scale factor of the model are given, together with a method for halving this error. Designs for illuminographic mirrors are presented: the first provides a further threefold reduction in proximity error; the second permits the estimation of thermal radiation transfer coefficients to interior regions of otherwise inaccessible volumes. Finally, reflex Polaroid camera techniques appropriate to the relatively small size of the illuminographic mirror are described.

Wiesner, S. J.↗

Thermal Modeling of Comet-like Objects from AKARI Observation

We investigated the physical properties of the comet-like objects 107P/(4015) Wilson–Harrington (4015WH) and P/2006 HR30 (Siding Spring; HR30) by applying a simple thermophysical model to the near-infrared spectroscopy and broadband observation data obtained by the AKARIsatellite of JAXA when they showed no detectable comet-like activity. We selected these two targets because the tendency of thermal inertia to decrease with the size of an asteroid, which has been demonstrated in recent studies, has not been confirmed for comet-like objects. It was found that 4015WH, which was originally discovered as a comet but has not shown comet-like activity after its discovery, has effective size D = 3.74–4.39 km and geometric albedo p{sub V}≈0.040--0.055 with thermal inertia Γ=100--250 J m{sup −2} K{sup −1} s{sup −1/2}. The corresponding grain size is estimated as 1–3 mm. We also found that HR30, which was observed as a bare cometary nucleus at the time of our observation, has D=23.9--27.1 km and p{sub V}=0.035--0.045 with Γ=250--1000 J m{sup −2} K{sup −1} s{sup −1/2}. We conjecture the pole latitude −20{sup ∘}≲β{sub s}≲+60{sup ∘}. The results for both targets are consistent with previous studies. Based on the results, we propose that comet-like objects are not clearly distinguishable from their asteroidal counterparts on the D–Γ plane.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Thermal Contact Resistance

One difficulty in using cryocoolers is making good thermal contact between the cooler and the instrument being cooled. The connection is often made through a bolted joint. The temperature drop associated with this joint has been the subject of many experimental and theoretical studies. The low temperature behavior of dry joints have shown some anomalous dependence on the surface condition of the mating parts. There is also some doubts on how well one can extrapolate from the test samples to predicting the performance of a real system. Both finite element and analytic models of a simple contact system have been developed. The model assumes (a) the contact is dry (contact limited to a small portion of the total available area and the spaces in-between the actual contact patches are perfect insulators), (b) contacts are clean (conductivity of the actual contact is the same as the bulk), (c) small temperature gradients (the bulk conductance may be assumed to be temperature independent), (d) the absolute temperature is low (thermal radiation effects are ignored), and (e) the dimensions of the nominal contact area are small compared to the thickness of the bulk material (the contact effects are localized near the contact). The models show that in the limit of actual contact area much less than the nominal area (a much less than A), that the excess temperature drop due to a single point of contact scales as a(exp -1/2). This disturbance only extends a distance approx. A(exp 1/2) into the bulk material. A group of identical contacts will result in an excess temperature drop that scales as n(exp -1/2), where n is the number of contacts and n dot a is constant. This implies that flat rough surfaces will have a lower excess temperature drop than flat polished surfaces.

Kittel, Peter↗

Thermal modeling and analysis of structurally complex spacecraft using the IDEAS system

Large antenna satellites of unprecedented sizes are needed for a number of applications. Antenna diameters on the order of 50 meters and upward are required. Such antennas involve the use of large expanses of lattice structures with hundreds or thousands of individual connecting members. In connection with the design of such structures, the consideration of thermal effects represents a crucial factor. Software capabilities have emerged which are coded to include major first order thermal effects and to purposely ignore, in the interest of computational efficiency, the secondary effects. The Interactive Design and Evaluation of Advanced Spacecraft (IDEAS) is one such system. It has been developed for an employment in connection with thermal-structural interaction analyses related to the design of large structurally complex classes of future spacecraft. An IDEAS overview is presented. Attention is given to a typical antenna analysis using IDEAS, the thermal and loading analyses of a tetrahedral truss spacecraft, and ecliptic and polar orbit analyses.

Garrett, L. B.↗

Infrared observations and thermal models of the Beta Pictoris disk

Measurements of the flux from the central portion of the Beta Pic disk performed via photometry at 3.5-20 microns in 4- and 8-arcsec apertures are presented. The 10.1- and 20-micron measurements show an excess which is extended, with significant flux located in the annulus between 4- and 8-arcsec diameter centered on the star. Disk models are calculated to reproduce the ground-based IR data, IRAS fluxes, IRAS 60-micron scan profile widths, and optical scattered light distribution. The color temperature and angular scale of the disk are found to be inconsistent with emission from large ('blackbody') particles: most of the thermal emission originates from particles which are inefficient radiators, with sizes near 1 micron. A simple disk with a single power-law spatial distribution is inconsistent with the combined optical and IR data. The inner disk component represents a gross deficit of material relative to an inward extrapolation of the outer component.

Backman, D. E.↗

Thermal Model for Horizontal In-Water and In-Air Mini-Plate Experiments in the Advanced Test Reactor

Mini-Plate (MP) irradiation tests are a fueled experiment designed for irradiation in multiple test locations in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). MP experiments are considered a non-instrumented drop-in test where small aluminum-clad fuel plate samples are cooled directly by the ATR Primary Coolant System (PCS) water. These fueled experiments contain aluminum-clad fuel mini plates consisting of monolithic U-10Mo. Previous thermal analyses have been documented concerning oxide growth[1] and thermal safety margin[2] for the MP-2 experiment. A thermal analysis has been performed on the MP-2 experiment using a new technique for calculating the necessary time after the experiment has been irradiated and reactor shutdown necessary to not exceed the 95% lower bound blister threshold temperature for the fuel in a horizontal in air configuration. A horizontal in water model has also been analyzed and will be discussed. After the experiment is irradiated in the ATR, it is necessary to calculate the fuel meat temperatures at 12 hours after shutdown. This is done to assure that at the 12 hour mark, if this experiment is removed from the reactor and accidentally dropped onto the working tray and is in the most severe geometrical configuration of horizontal (minimum heat transfer) that fission products will not be released. The blister threshold temperature is considered this safety limit. The horizontal in air analysis is also performed considering that the experiment is horizontal in a drained canal and filled with air and natural convection heat transfer with air on the outside. The initial mini-plate testing campaign known as MP-1 [3] has been irradiated and its purpose was to form the base fuel specimens fabricated by various processes so that a single process can be down-selected for qualification. MP-2 will then serve to populate a comprehensive fuel performance data set for the down-selected fabrication process. The MP-2 experiment will be irradiated in several locations of the ATR as shown in Figure 1. The fuel plate thickness and geometry is identical to the MP-1 experiment [3], with the only variable being the fuel meat thickness. This model of the B-12 position is treated as encompassing the I-21, I-24, and B-9 positions since it has more fuel and higher total heat than the other positions. Since the blister threshold temperature is a function of fission density, a series of fission densities is calculated for the B-12 position to cover the other three positions. The B 12 position specifically uses fuel meat that is 0.016 in thick by 3.25 in long and 0.75 in tall. The total plate thickness is 0.050 in. Aluminum cladding forms the barrier between the PCS and the fuel meat. The purpose of this paper is to demonstrate this new technique developed to calculate the necessary decay time after shutdown for a series of fission densities using the ABAQUS [4] finite element and heat transfer code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Modeling and Cryogenic Design of a Helical Superconducting Undulator Cryostat

A conceptual design for a helical superconducting undulator (HSCU) for the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) has been completed. The device differs sufficiently from the existing APS planar superconducting undulator (SCU) design to warrant development of a new cryostat based on value engineering and lessons learned from the existing planar SCU. Changes include optimization of the existing cryocooler-based refrigeration system and thermal shield as well as cost reduction through the use of standard vacuum hardware. The end result is a design that provides significantly larger 4.2 K refrigeration margin in a smaller package for greater installation flexibility in the APS storage ring. This paper presents ANSYS-based thermal analysis of the cryostat, including estimated static and dynamic

Shiroyanagi, Y.↗

Accelerating Adoption of Energy-Efficient Technology with the Thermalize Model

The accelerating impacts of climate change destabilize food systems and ecosystems alongside the communities that rely on them. Thus, climate resilience is a health equity issue at both a physical (relating to biological impacts of pollution and environmental degradation) and a cultural level (loss of subsistence lifestyles, languages, etc). With roughly 20% of US energy-related greenhouse gas emissions stemming from heating, cooling, and powering households, accessible energy-efficient home retrofits are a critical element of climate change mitigation strategies. For communities already producing electricity from renewable sources, like Juneau, incentivizing ductless heat pump upgrades and energy efficiency retrofits provides an accessible pathway to transition households away from oil heating and drastically reduce emissions. Thermalize Juneau is a pilot program that will explore a repeatable framework for accelerating the adoption of energy-efficient technology in Alaska communities. This poster will describe Thermalize Juneau's goals and framework, progress through spring 2021, and future plans.

ductless heat pumps↗

Thermal Model of Oxide Growth for Full Size Fuel Plate Experiments in the Advanced Test Reactor

The full-size plate number one (FSP-1) irradiation test designed for irradiation testing of plate type fuel is planned to be irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). This FSP-1 experiment is a non-instrumented drop-in test where aluminum-clad fuel plates are cooled directly by the ATR Primary Coolant System (PCS) water. This experiment is one of a series of experiments being irradiated at ATR for the United States High Performance Research Reactor (USHPRR) program. This fueled experiment contains aluminum-clad fuel full-size plates consisting of monolithic U-10Mo. Previous thermal analyses have been documented concerning oxide growth [1] and thermal safety margins [2] for similar U-10Mo mini plate experiments. This analysis is part of the thermal safety analysis of the experiment to be irradiated in ATR. Departure from nucleate boiling ratio (DNBR) and flow instability ratio (FIR) have been calculated for the flow coastdown condition 2 and the reactivity insertion accident condition-2 (RIA2) transient. The purpose of this paper is to investigate the thermal margin of the fuel meat during a RIA2 transient when oxide has accumulated on the plate surfaces acting as an insulator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DPC Direct Disposal Postclosure Thermal Modeling

Performance of geologic radioactive waste repositories depends on near-field and far-field processes, including km-scale flow and transport in engineered and natural barriers, that may require simulations of up to 1 M years of regulatory period. For a relatively short time span (less than 1000 years), the thermohydro-mechanical-chemical (THMC) coupled processes caused by heat from the waste package will influence near-field multiphase flow, chemical/reactive transport, and mechanical behaviors in the repository system. This study integrates the heat-driven perturbations in thermo-hydro-mechanical characteristics into thermo-hydro-chemical simulations using PFLOTRAN to reduce dimensionality and improve computational efficiency by implementing functions of stress-dependent permeability and saturation-temperature-dependent thermal conductivity. These process couplings are developed for spent nuclear fuel in dual-purpose canisters in two different hypothetical repositories: a shale repository and a salt repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal model to quantify the impact of sub-bandgap reflectance on operating temperature of fielded PV modules

Minimizing module heating is an effective way to increase the lifetime energy output of photovoltaic systems. Maximizing the reflection of light that is unusable for energy conversion is one of the most promising ways to reduce the operating temperature of fielded modules. We derive a model based on a steady-state energy balance to quantify the temperature benefit of cell or module optical modifications aimed at improving reflection of light with photon energies below the photovoltaic cell bandgap energy. This more detailed model is then simplified so that, from outdoor measured data, temperature differences arising from reflectance can be isolated from those arising from irradiance, wind speed, and module standard-test-condition efficiency.

14 SOLAR ENERGY↗

Ion Exchange Column Thermal Modeling: Prevention of Process Effluent Boiling - 18577

The Savannah River Site treats and disposes of legacy high-level waste, which resulted from 60 years of nuclear material production, medical research, and other nuclear related work. Complex mixtures of soluble and insoluble solids occupy tanks of which the South Carolina Department of Health and Environmental Control recognizes as the single largest environmental risk state-wide. The risk is reduced through removal, treatment, and solidification of decontaminated salt waste. Presently, SRS decontaminates the soluble salt component of the waste, a solution containing actinides and cesium, via implementation of the Actinide Removal Process and the Modular Caustic Side Solvent- Extraction Unit. Caustic solvent extraction is set to increase in scale by late 2018, with startup of the newly constructed Salt Waste Processing Facility. In conjunction with Salt Waste Processing Facility startup, Savannah River Remediation has been tasked by the Department of Energy to demonstrate modular ion exchange technology. The Tank Closure Cesium Removal project aims to demonstrate the feasibility of modular ion exchange processes for future Department of Energy applications. The Tank Closure Cesium Removal system is scheduled to begin operation in mid-2018. Dissolved salt solution, or influent, will be fed through a filter and ion exchange columns in lead-lag configuration, producing effluent. The effluent is fed to a separate high-level waste tank, for future disposition at Salt-stone Production Facility. Once the demonstration project is complete, the loaded ion exchange columns will be purged, dried, and placed in interim safe storage, awaiting final disposition. The ion exchange media selected for the Tank Closure Cesium Removal system is Honeywell UOP IONSIV{sup C} R-9120. The media is a prime candidate for separation of cesium from radioactive high-level waste. UOP R-9120{sup C} is inorganic and has high capacity, selectivity, and affinity for cesium. During operation, influent is fed to the ion exchange columns, contacting UOP R-9210{sup C} packed within the media vessel. Contact initiates loading of isotopes, and given ample time the solid phase (ion exchange media) and solution achieve thermodynamic equilibrium. UOP R-9120{sup C} is a prime candidate for separation of cesium and dissolved fission products. Although the properties of UOP R-9120{sup C} are favorable for separation, the same properties lead to accumulation of a heat source in the ion exchange bed. Cesium-137 and its daughter product, barium-137 m, generate a clear majority of heat (i.e. ∼ 94%). During operation salt solution flows through each column and transports heat from the ion exchange bed. Once operation is terminated, the effluent contained within the porous bed volume becomes essentially static. In the absence of engineering controls, the heat generated may boil the effluent. Rapid vaporization of aqueous salt solution would lead to bed over pressurization. Over pressurization and an associated release of high-level waste would result in adverse impacts to human health and the environment. This paper focuses on modeling the heat transfer associated with the Tank Closure Cesium Removal system ion exchange column. The model evaluates the maximum heat generation and the associated radionuclide loadings that prevent boiling within of the media vessel, under no flow conditions. A safety significant control, maintaining loadings less than the established loading limit ensures associated impacts to human health and the environment are prevented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗