Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank Farm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Organic Evaporation and Oxidation Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method to supplement vitrification. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. This work evaluates potential avenues to eliminate that impediment to permit possible use of a cementitious waste form and work towards a decision whether additional LDR organic pretreatment would be required. Savannah River National Laboratory (SRNL) performed testing using simulants to examine evaporation as a method to remove some prevalent organics from LAW. Spiking the caustic LAW simulant with selected regulated organic chemicals found one that clearly decomposes because of caustic instability. Oxidation testing of other organic chemicals found some LDR organics degrade as desired and others are stable in the presence of peroxide and permanganate. In addition to studies with simulants, a literature review was performed to evaluate radiological stability of LDR organics. Descriptions of the experimental details, equipment, and results are included in this report. Evaporation testing consisted of preparing the LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation) and also at atmospheric pressure. The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na + ] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species. Organic chemicals were chosen for the work with a consideration of how their volatility compares with that of methanol. This was done by comparing the ratio of the pure water Henry’s law coefficient (K h ) of methanol to that of the compound in question (hereafter termed the K h ratio), where ratios above unity indicated less volatility than methanol. Methanol was chosen because it is a common regulated chemical with relatively low volatility but which has been removed by evaporation in previous laboratory work. While organic separation results depend on evaporator design, laboratory experiments verified that organic partitioning to the overhead condensate stream by evaporation is a practical process. The work reported here found difficulties in quantitative analysis of the organic chemicals in aqueous samples. Most of the time there was insufficient analysis to close a mass balance for evaporator runs, but qualitative evidence of carryover was obtained. The methods were also able to show whether organic chemicals were susceptible or resistant to solution oxidation in permanganate or hydrogen peroxide tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 54 to 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form. Vacuum evaporation testing to remove LDR organics consisted of preparing a non-radioactive LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation). The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na+] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating Residual Solids Volume In Underground Storage Tanks

The Savannah River Site liquid waste system consists of multiple facilities to safely receive and store legacy radioactive waste, treat, and permanently dispose waste. The large underground storage tanks and associated equipment, known as the 'tank farms', include a complex interconnected transfer system which includes underground transfer pipelines and ancillary equipment to direct the flow of waste. The waste in the tanks is present in three forms: supernatant, sludge, and salt. The supernatant is a multi-component aqueous mixture, while sludge is a gel-like substance which consists of insoluble solids and entrapped supernatant. The waste from these tanks is retrieved and treated as sludge or salt. The high level (radioactive) fraction of the waste is vitrified into a glass waste form, while the low-level waste is immobilized in a cementitious grout waste form called saltstone. Once the waste is retrieved and processed, the tanks are closed via removing the bulk of the waste, chemical cleaning, heel removal, stabilizing remaining residuals with tailored grout formulations and severing/sealing external penetrations. The comprehensive liquid waste disposition system, currently managed by Savannah River Remediation, consists of 1) safe storage and retrieval of the waste as it is prepared for permanent disposition; (2) definition of the waste processing techniques utilized to separate the high-level waste fraction/low-level waste fraction; (3) disposition of LLW in saltstone; (4) disposition of the HLW in glass; and (5) closure state of the facilities, including tanks. This paper focuses on determining the effectiveness of waste removal campaigns through monitoring the volume of residual solids in the waste tanks. Volume estimates of the residual solids are performed by creating a map of the residual solids on the waste tank bottom using video and still digital images. The map is then used to calculate the volume of solids remaining in the waste tank. The ability to accurately determine a volume is a function of the quantity and quality of the waste tank images. Currently, mapping is performed remotely with closed circuit video cameras and still photograph cameras due to the hazardous environment. There are two methods that can be used to create a solids volume map. These methods are: liquid transfer mapping / post transfer mapping and final residual solids mapping. The task is performed during a transfer because the liquid level (which is a known value determined by a level measurement device) is used as a landmark to indicate solids accumulation heights. The post transfer method is primarily utilized after the majority of waste has been removed. This method relies on video and still digital images of the waste tank after the liquid transfer is complete to obtain the relative height of solids across a waste tank in relation to known and usable landmarks within the waste tank (cooling coils, column base plates, etc.). In order to accurately monitor solids over time across various cleaning campaigns, and provide a technical basis to support final waste tank closure, a consistent methodology for volume determination has been developed and implemented at SRS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Crucible Vitrification of CST and Simulated Hanford Tank Waste

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility for immobilization. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated by the Tank-Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18× 10 -5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream through ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural Analysis Results of Thermal, Operating and Seismic Analysis for Hanford Single-Shell Tank Integrity - 12261

Since Hanford's 149 Single-Shell Tanks (SSTs) are well beyond their design life, the U.S. Department of Energy has commissioned a state of the art engineering analysis to assess the structural integrity of the tanks to ensure that they are fit for service during the cleanup and closure phase. The structural integrity analysis has several challenging factors. There are four different tank sizes in various configurations that require analysis. Within each tank type there are different waste level and temperature histories, soil overburden depths, tank floor arrangements, riser sizes and locations, and other on-tank structures that need to be addressed. Furthermore, soil properties vary throughout the tank farms. This paper describes the structural integrity analysis that was performed for the SSTs using finite element models that incorporate the detailed design features of each tank type. The analysis was performed with two different models: an ANSYS static model for the Thermal and Operating Loads Analysis, and an ANSYS dynamic model for the seismic analysis. The TOLA analyses simulate the waste level and thermal history and it included a matrix of analysis cases that bounded the material property uncertainties. The TOLA also predicts the occurrence of concrete thermal degradations and cracking, reinforcement yielding, and soil plasticity. The seismic analysis matrix included uncertainty in waste properties, waste height and the soil modulus. In seismic analysis the tank concrete was modeled as a linear elastic material that was adjusted for the present day degraded conditions. Also, the soil was treated as a linear elastic material while special modeling techniques were used to avoid soil arching and achieve proper soil pressure on the tank walls. Seismic time histories in both the horizontal and vertical directions were applied to the seismic model. Structural demands from both Thermal and Operating Loads Analysis and seismic models were extracted in the form of section forces and moments for sections throughout the tank under the appropriate load combinations. These demands were evaluated against the American Concrete Institute (ACI) code requirements for nuclear safety-related concrete structures as defined in ACI-349-06. Structural integrity analysis of Hanford's Type II and Type III Single-Shell Tanks (SSTs) was performed using finite element models (ANSYS software) that incorporate the detailed design features of each tank type. The analysis was performed with two different models: a static model for the Thermal and Operating Loads Analysis, and a dynamic model for the seismic analysis. Structural demands from both Thermal and Operating Loads Analysis and seismic models were evaluated against the American Concrete Institute (ACI) code requirements for nuclear safety-related concrete structures as defined in ACI-349-06. The ratio of demand to capacity (D/C) was reported as a measure of structural integrity for the applicable ACI-349-06 load combinations. Although the Type II and Type III analysis matrix showed varying demands depending on the material combinations, all of the tank regions that are critical to structural stability passed the ACI 349-06 acceptance criteria. This was true for the conservative combination of maximum recorded thermal loads and maximum soil overburden depth combined with the analysis matrix of bounding material property combinations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reevaluation Of The Risk Of Solids Formation In The 2h Evaporator System

Savannah River Remediation (SRR) Tank Farm Engineering requested further technical assistance from the Savannah River National Laboratory (SRNL) to reassess the risk of solids formation in the 2H Evaporator system following feed tank and drop tank blending operations conducted between 12/15/2018 and 1/6/2019. OLI aqueous electrolyte model simulations were completed for three variable-depth, post-blending liquid waste samples collected from Tank 43 on 1/27/2019. The purpose of the new simulations is to provide guidance to SRR on a recommended maximum overhead-to-feed volume ratio to avoid unwanted solids formation upon restart of the 2H Evaporator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SNL API-653 In-Service Tank Inspection and Evaluation Tank ID: 981-A2-T0 (West)

An API Standard 653 In-Service inspection was completed on Tank 981-A2-T0 (West) located at the Sandia National Laboratories TAIV tank farm in Albuquerque, NM on September 22, 2015. The inspection was completed to collect data to evaluate the mechanical integrity and fitness for continued service of the tank. No indication or records of any previous inspection were identified for this tank. The inspection and engineering evaluation were completed using API-653, 5 th Edition and conservative engineering practices. The tank was not removed from service, so an internal inspection could not be completed. The tank was also fully insulated. The insulation was removed in specified areas of the tank shell and tank chime to accommodate an acoustic emission scan of the tank and an ultrasonic thickness evaluation of portions of the tank. The acoustic emission scan resulted in a grade of B / I - II indicating an overall TANKPAC grade B and composite grade II indicating minor active damage with highly concentrated sources related to corrosion found in the southeast and west side section of the tank. Eight Potential Localized Damage sources were found mainly in the west side (re-test in 2 years). The tank chime could not be inspected due to the configuration of the insulation welded angle support. An ultrasonic guided bulk wave inspection was completed on the tank shell to assess the lower shell section. At the time of the inspection the limited data collected showed minimal material loss from the shell at the thickness monitoring locations, however, visual inspection and pit depth gauge measurements showed > 3/16” inch pitting and significant general external surface corrosion on the shell at the shell to floor joint. This corrosion is caused by the insulation sheeting support welded angle iron trapping moisture and dirt against the tank shell. This tank should be removed from service, internally inspected, and repaired. Ultrasonic thickness measurement locations were established on this tank and the data is included in this report. The limited data collected indicated minimal material loss at these locations, with the only noted corrosion occurring on the tank shell to floor joint as noted above. An API-653 Annex B Evaluation of Tank Bottom Settlement was completed and the results are included in this report. No significant settlement issues were identified.

42 ENGINEERING↗

ELECTROCHEMICAL CORROSION TESTING OF TANKS 241-AN-102 & 241-AP-107 & 241-AP-108 IN SUPPORT OF ULTRASONIC TESTING

This report presents the results of the corrosion rates that were measured using electrochemical methods for tanks 241-AN-102 (AN-102), 241-AP-107 (AP 107), and 241-AP-108 (AP-108) performed under test plant RPP-PLAN-38215. The steel used as materials of construction for AN and AP tank farms was A537 Class 1. Test coupons of A537 Class 1 carbon steel were used for corrosion testing in the AN-107, AP-107, and AP-108 tank waste. Supernate will be tested from AN-102, AP-107, and Ap-108. Saltcake testing was performed on AP-108 only.

36 MATERIALS SCIENCE↗

Low-Activity Waste Pretreatment System Additional Engineering-Scale Integrated Test Report

Washington River Protections Solutions, LLC’s (WRPS) Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low-activity waste (ILAW) by feeding LAW directly from Tank Farms to the Waste Treatment and Immobilization Plant (WTP) LAW Facility, bypassing the WTP Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria (WAC). Full-scale and engineering-scale testing of critical technology elements, as part of the technology maturation process, are components of the overall LAWPS Project. WRPS awarded the engineering-scale integrated testing scope to AECOM via WRPS Subcontract 58349. This report is deliverable MSR-008 of the subcontract.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Sludge Solids Returns Impacts on Sludge Batch 10 Flammability, Glass Quality, and Glass Processability

The Savannah River National Laboratory (SRNL) is currently preparing to return ≤ 20 kgs of sludge solids collected over time from Tank Farm characterization activities and demonstrations of the Defense Waste Processing Facility (DWPF) flowsheets (nitric-formic and nitric-glycolic). These sludge solids will be transported and added to Tank 51 which is currently preparing Sludge Batch (SB) 10. DWPF plans to operate the under the nitric-glycolic flowsheet for the processing of SB10. The hydrogen generation rate for the nitric-glycolic flowsheet is 0.024 lb h -1 . The addition of ≤20 kg of sludge solids returns to SB 10 does not have an impact on flammability in the DWPF Chemical Process Cell (CPC) or glass quality and processability. The relatively low mass of the addition (≤20 kg) is insufficient to detect a significant analytical change to the expected SB 10 compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HANFORD DOUBLE SHELL TANK THERMAL AND SEISMIC PROJECT SUMMARY OF COMBINED THERMAL AND OPERATING LOADS WITH SEISMIC ANALYSIS

This report summarizes the results of the Double-Shell Tank Thermal and Operating Loads Analysis (TaLA) combined with the Seismic Analysis. This combined analysis provides a thorough, defensible, and documented analysis that will become a part of the overall analysis of record for the Hanford double-shell tanks (DSTs). The bases of the analytical work presented herein are two ANSYS{reg_sign} finite element models that were developed to represent a bounding-case tank. The TaLA model includes the effects of temperature on material properties, creep, concrete cracking, and various waste and annulus pressure-loading conditions. The seismic model considers the interaction of the tanks with the surrounding soil including a range of soil properties, and the effects of the waste contents during a seismic event. The structural evaluations completed with the representative tank models do not reveal any structural deficiencies with the integrity of the DSTs. The analyses represent 60 years of use, which extends well beyond the current date. In addition, the temperature loads imposed on the model are significantly more severe than any service to date or proposed for the future. Bounding material properties were also selected to provide the most severe combinations. While the focus of the analyses was a bounding-case tank, it was necessary during various evaluations to conduct tank-specific analyses. The primary tank buckling evaluation was carried out on a tank-specific basis because of the sensitivity to waste height, specific gravity, tank wall thickness, and primary tank vapor space vacuum limit. For this analysis, the occurrence of maximum tank vacuum was classified as a service level C, emergency load condition. The only area of potential concern in the analysis was with the buckling evaluation of the AP tank, which showed the current limit on demand of l2-inch water gauge vacuum to exceed the allowable of 10.4 inches. This determination was based on analysis at the design waste temperature of 350 F and the full 60-year corrosion allowance on the tank wall of 0.060 inch. However, analysis at a more realistic temperature of 250 F or corrosion allowance of 0.025 inch results in an acceptable demand/capacity ratio according to the ASME code criteria. Thus, buckling of the primary tank is judged to be unlikely for the current lack of corrosion in the tanks, and the expectation that the maximum waste temperature will not exceed 210 F. The reinforced concrete structure was evaluated as specified by the American Concrete Institute (ACI) code requirements for nuclear safety-related structures (ACI-349). The demand was demonstrated to be lower than the capacity at all locations. Revision 1 is being issued to document changes to the anchor bolt evaluation. RPP-RPT-32237 Rev. 1, Hanford Double-Shell Tank Thermal and Seismic Project-Increased Liquid Level Analysis for 241AP Tank Farms, described changes to the anchor bolt modeling and evaluation which were implemented in response to the independent reviewer's comments. Similar changes have been made in the bounding tank analysis and are documented in RPP-RPT-28968 Rev. 1. The conclusions of the previous releases of this report remain unchanged.

36 MATERIALS SCIENCE↗

ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM 2010

Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2010 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2010 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2009-00138, HLW Tank Farm Inspection Plan for 2010, were completed. Ultrasonic measurements (UT) performed in 2010 met the requirements of C-ESG-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 30, 31 and 32 and the findings are documented in SRNL-STI-2010-00533, Tank Inspection NDE Results for Fiscal Year 2010, Waste Tanks 30, 31 and 32. A total of 5824 photographs were made and 1087 visual and video inspections were performed during 2010. Ten new leaksites at Tank 5 were identified in 2010. The locations of these leaksites are documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.5. Ten leaksites at Tank 5 were documented during tank wall/annulus cleaning activities. None of these new leaksites resulted in a release to the environment. The leaksites were documented during wall cleaning activities and the waste nodules associated with the leaksites were washed away. Previously documented leaksites were reactivated at Tank 12 during waste removal activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of The Risk of Solids Formation in the 2H Evaporator System

Savannah River Remediation (SRR) Tank Farm Engineering requested technical assistance from the Savannah River National Laboratory (SRNL) to troubleshoot recent and rapid plugging of the 2H Evaporator gravity drain line (GDL) to the Evaporator Drop Tank (currently Tank 38) with unwanted solids of unknown composition and to evaluate the risk of solids formation in the 2H Evaporator system moving forward. The GDL to Tank 38 recently plugged twice within hours of startup, resulting in a one-month shutdown both times. SRNL was asked to simulate current and historic (2016 to 2017) aqueous feed chemistries in the Evaporator Feed Tank (currently Tank 43) using the OLI Systems software to determine the mass of precipitated salts that would be expected to form under 2H Evaporator operating conditions for a range of concentration factors (i.e., evaporator overhead-to-feed volume ratio). A recommended evaporator concentration factor was determined based on the current Tank 43 feed composition to minimize solids formation and extend the time between shutdowns. Current and historic (2016 to 2017) aqueous chemistries in Tank 38 were also evaluated for completeness.

42 ENGINEERING↗

Surface Geophysical Exploration – Compendium Document

This report documents the evolution of the surface geophysical exploration (SGE) program and highlights some of the most recent successes in imaging conductive targets related to past leaks within and around Hanford's tank farms. While it is noted that the SGE program consists of multiple geophysical techniques designed to (1) locate near surface infrastructure that may interfere with (2) subsurface plume mapping, the report will focus primarily on electrical resistivity acquisition and processing for plume mapping. Due to the interferences from the near surface piping network, tanks, fences, wells, etc., the results of the three-dimensional (3D) reconstruction of electrical resistivity was more representative of metal than the high ionic strength plumes. Since the first deployment, the focus of the SGE program has been to acquire and model the best electrical resistivity data that minimizes the influence of buried metal objects. Toward that goal, two significant advances have occurred: (1) using the infrastructure directly in the acquisition campaign and (2) placement of electrodes beneath the infrastructure. The direct use of infrastructure was successfully demonstrated at T farm by using wells as long electrodes (Rucker et al., 2010, 'Electrical-Resistivity Characterization of an Industrial Site Using Long Electrodes'). While the method was capable of finding targets related to past releases, a loss of vertical resolution was the trade-off. The burying of electrodes below the infrastructure helped to increase the vertical resolution, as long as a sufficient number of electrodes are available for the acquisition campaign.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ostwald Ripening and Its Effect on PuO2 Particle Size in Hanford Tank Waste

Between 1944 and 1989, the Hanford Site produced 60 percent (54.5 metric tons) of the United States weapons plutonium and produced an additional 12.9 metric tons of fuels-grade plutonium. High activity wastes, including plutonium lost from the separations processes used to isolate the plutonium, were discharged to underground storage tanks during these operations. Plutonium in the Hanford tank farms is estimated to be {approx}700 kg but may be up to {approx}1000 kg. Despite these apparent large quantities, the average plutonium concentration in the {approx}200 million liter tank waste volume is only about 0.003 grams per liter ({approx}0.0002 wt%). The plutonium is largely associated with low solubility metal hydroxide/oxide sludges where its low concentration and intimate mixture with neutron-absorbing elements (e.g., iron) are credited in nuclear criticality safety. However, concerns have been expressed that plutonium, in the form of plutonium hydrous oxide, PuO{sub 2} {center_dot} xH{sub 2}O, could undergo sufficient crystal growth through Ostwald ripening in the alkaline tank waste to potentially be separable from neutron absorbing constituents by settling or sedimentation. It was found that plutonium that entered the alkaline tank waste by precipitation through neutralization from acid solution is initially present as 2- to 3-nm (0.002- to 0.003-{mu}m) scale PuO{sub 2} {center_dot} xH{sub 2}O crystallite particles and grows from that point at exceedingly slow rates, posing no risk to physical segregation. These conclusions are reached by both general considerations of Ostwald ripening and specific observations of the behaviors of PuO{sub 2} and PuO{sub 2} {center_dot} xH{sub 2}O upon aging in alkaline solution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scanning Electron Microscopy and X-Ray Diffraction Analysis of Tank 18 Samples

The F-Area Tank Farm (FTF) Performance Assessment (PA) utilizes waste speciation in the waste release model used in the FTF fate and transport modeling. The waste release modeling associated with the residual plutonium in Tank 18 has been identified as a primary contributor to the Tank 18 dose uncertainty. In order to reduce the uncertainty related to plutonium in Tank 18, a better understanding of the plutonium speciation in the Tank 18 waste (including the oxidation state and stoichiometry) is desired. Savannah River National Laboratory (SRNL) utilized Scanning Electron Microscopy (SEM) and X-ray Diffraction (XRD) to analyze Tank 18 samples to provide information on the speciation of plutonium in the waste material. XRD analysis of the Tank 18 samples did not identify any plutonium mineral phases in the samples. These indicates the crystalline mineral phases of plutonium are below the detection limits of the XRD method or that the plutonium phase(s) lack long range order and are present as amorphous or microcrystalline solids. SEM analysis of the Tank 18 samples did locate particles containing plutonium. The plutonium was found as small particles, usually <1 μm but ranging up to several micrometers in diameter, associated with particles of an iron matrix and at low concentration in other elemental matrices. This suggests the plutonium has an affinity for the iron matrix. Qualitatively, the particles of plutonium found in the SEM analysis do not appear to account for all of the plutonium in the sample based on concentrations determined from the chemical analysis of the Tank 18 samples. This suggests that plutonium is also distributed throughout the solids in low concentrations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Radioactive Waste Tank Inspection Program - 2011

Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2011 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2011 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2011-00026, HLW Tank Farm Inspection Plan for 2011, were completed. Ultrasonic measurements (UT) performed in 2011 met the requirements of C-ESR-G-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 25, 26 and 34 and the findings are documented in SRNL-STI-2011-00495, Tank Inspection NDE Results for Fiscal Year 2011, Waste Tanks 25, 26, 34 and 41. A total of 5813 photographs were made and 835 visual and video inspections were performed during 2011. A potential leaksite was discovered at Tank 4 during routine annual inspections performed in 2011. The new crack, which is above the allowable fill level, resulted in no release to the environment or tank annulus. The location of the crack is documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Phase II Study - Mercury Behavior in Salt Processing Flowsheet

Mercury (Hg) in the Savannah River Site Liquid Waste System (LWS) originated from decades of canyon processing where it was used as a catalyst for dissolving the aluminum cladding of reactor fuel. Approximately 60 metric tons of mercury is currently present throughout the LWS. Mercury has long been a consideration in the LWS, from both hazard and processing perspectives. In February 2015, a Mercury Program Team was established at the request of the Department of Energy to develop a comprehensive action plan for long-term management and removal of mercury. Evaluation was focused in two Phases. Phase I activities assessed the Liquid Waste inventory and chemical processing behavior using a system-by-system review methodology, and determined the speciation of the different mercury forms (Hg+, Hg++, elemental Hg, organomercury, and soluble versus insoluble mercury) within the LWS. Phase II activities are building on the Phase I activities, and results of the LWS flowsheet evaluations will be summarized in three reports: Mercury Behavior in the Salt Processing Flowsheet (i.e. this report); Mercury Behavior in the Defense Waste Processing Facility (DWPF) Flowsheet; and Mercury behavior in the Tank Farm Flowsheet (Evaporator Operations). The evaluation of the mercury behavior in the salt processing flowsheet indicates, inter alia, the following: (1) In the assembled Salt Batches 7, 8 and 9 in Tank 21, the total mercury is mostly soluble with methylmercury (MHg) contributing over 50% of the total mercury. Based on the analyses of samples from 2H Evaporator feed and drop tanks (Tanks 38/43), the source of MHg in Salt Batches 7, 8 and 9 can be attributed to the 2H evaporator concentrate used in assembling the salt batches. The 2H Evaporator is used to evaporate DWPF recycle water. (2) Comparison of data between Tank 21/49, Salt Solution Feed Tank (SSFT), Decontaminated Salt Solution Hold Tank (DSSHT), and Tank 50 samples suggests that the total mercury as well as speciated forms in the assembled salt batches in Tanks 21/49 pass through the Actinide Removal Process (ARP) / Modular Caustic Side Solvent Extraction Unit (MCU) process to Tank 50 with no significant change in the mercury chemistry. (3) In Tank 50, Decontaminated Salt Solution (DSS) from ARP/MCU is the major contributor to the total mercury including MHg. (4) Speciation analyses of TCLP leached solutions of the grout samples prepared from Tank 21, as well as Tank 50 samples, show the majority of the mercury released in the solution is MHg.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗