SEARCH · Engineering Papers
Results for “TREATIES”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A stilbene - CdZnTe based radioxenon detection system
Atmospheric monitoring of radioxenon is one of the most widely used methods by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) to detect elevated levels of 131m Xe, 133/133m Xe, and 135 Xe. The ratios of these radionuclides help discriminate between peaceful use of nuclear technology and nuclear weapon explosions. Radioxenon detection systems often use plastic scintillators in the capacity of an electron detector and a gas cell, plastic gas cells are responsible for introducing high memory effect in these systems. This work presents the design of a new detection system for radioxenon monitoring that utilizes silicon photomultipliers, a stilbene gas cell, and a CdZnTe detector. This detector was evaluated using xenon radioisotope samples produced in the TRIGA reactor at Oregon State University. Here, a 48-h background was collected and calculations of the Minimum Detectable Concentration (MDC) were carried out using the Region of Interest (ROI) approach. An MDC of less than 1 mBq/m 3 was obtained for 131m Xe, 133 Xe, and 133m Xe in accordance with the sensitivity limits set by the CTBTO and performs respectably when compared to state-of-the-art radioxenon detection systems. Using 131m Xe, this study indicates that the stilbene gas cell exhibits a memory effect of 0.045 ±0.017%, this is almost a two-order magnitude improvement compared to plastic scintillators. The main purpose of this work is to explore the use of new stilbene detection media for radioxenon application and addressing the problem of memory effect.
The detectability of the Wigwam underwater nuclear explosion by the radionuclide stations of the International Monitoring System
Not Available
Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere
Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.
Modeling of fission and activation products in molten salt reactors and their potential impact on the radionuclide monitoring stations of the International Monitoring System
Molten Salt Reactors (MSRs) are one of six Generation IV reactor designs currently under development around the world. Because of the unique operating conditions of MSRs, which include molten fuel and the continuous removal of gaseous fission products during operation, work was performed to analyze the potential impact of emissions on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Simulations were performed to predict the production of IMS-relevant radionuclides in four MSR designs operating under two scenarios: (1) a sealed reactor with releases only during operational shutdown, and (2) continuous reprocessing or sparging of the fuel salt. From these production estimates the radioxenon and radioiodine signatures were extracted and compared to three current reactor designs (Pressurized Water Reactor (PWR), BWR, RBMK). In cases where continuous reprocessing of the fuel salt occurred, both the radioxenon and radioiodine signatures were nearly indistinguishable from a nuclear explosion. Estimates were also made of the potential emission rate of radioxenon for three reactor designs and it was found that MSRs have the potential to emit radioxenon isotopes at a rate of 10^15-8×10^16 Bq/d for 133Xe if no abatement is used. An assessment was made of activation products using a candidate fuel salt (FLiBe) mixed with corrosion products for the Thorium Molten Salt Reactor (TMSR-LF1).
Projected network performance for multiple isotopes using next-generation xenon monitoring systems
Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.
Phase II testing of Xenon International on Mount Schauinsland, Germany
Station RN33 on Mount Schauinsland near Freiburg, Germany, is part of the International Monitoring System monitoring radioxenon in air ( 131m Xe, 133 Xe, 133m Xe, and 135 Xe) for verification of the Comprehensive Nuclear Test Ban Treaty. Here, we present data from phase II testing of a new system, Xenon International at RN33, July 14th, 2021 to Jan 22nd, 2022, together with SPALAX data from the same time period. Radioxenon could be detected in 473 of 719 samples, among them many multiple isotope detections. Activity concentrations of spiked and selected environmental samples were verified by laboratory reanalysis. Finally, the sensitivity of Xenon International for radioxenons is up to one order of magnitude better for the metastable isotopes than that of the SPALAX, with a shorter sampling duration of 6 h.
Projected network performance for next generation aerosol monitoring systems
Aerosol monitoring for radioactivity is a mature and proven technology. However, by improving key specifications of aerosol monitoring equipment, more samples per day can be collected and analyzed with the same minimum detectable concentrations as current systems. This work models hypothetical releases of 140 Ba and 131 I over a range of magnitudes corresponding to the inventory produced from the fission of about 100 g to 1 kiloton TNT-equivalent of 235 U. The releases occur over an entire year to incorporate the natural variability in atmospheric transport. Sampling equipment located at the 79 locations for radionuclide stations identified in the Comprehensive Nuclear-Test-Ban Treaty (CTBT) for the International Monitoring System are used to determine the detections of the individual releases. Alternative collection schemes in next generation equipment that collect 2, 3, or 4 samples per day, rather than the current 1 sample per day, would result in detections in many more samples at more stations with detections for a given release level. The authors posit that next generation equipment will result in increased network resilience to outages and improved source-location capability for lower yield source releases. The application of dual-detector and coincidence measurements to these systems would significantly boost sensitivity for some isotopes and would further enhance the monitoring capability.
Radionuclide measurements of the international monitoring system
The International Monitoring System (IMS) is a unique global network of sensors, tuned to measure various phenomenology, with the common goal of detecting a nuclear explosion anywhere in the world. One component of this network collects measurements of radioactive particulates and gases (collectively known as radionuclides) present in the atmosphere; through this, compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) can be verified. The radionuclide sub-network consists of 120 sensors across 80 locations, supported by 16 measurement laboratories. All radionuclide stations make use of a form of γ-ray spectroscopy to measure radionuclides from samples; this remains largely unchanged since the network was first established 25 years ago. Advances in sampling and spectroscopy systems can yield improvements to the sensitivity of the network to detect a nuclear explosion. This paper summarises the status of the IMS radionuclide network, the current suite of technology used and reviews new technology that could enhance future iterations, potentially improving the verification power of the IMS.
Comparison of source-location algorithms for atmospheric samplers
Numerous algorithms have been developed to determine the source characteristics for an atmospheric release, e.g., (Bieringer et al., 2017). This study compares three models that have been applied to the data collected by the International Monitoring System operated by the Comprehensive Nuclear-Test-Ban Treaty Preparatory Commission to estimate source event parameters. Each model uses a different approach to estimate the parameters. A deterministic model uses a possible source region (PSR) approach (Ringbom et al., 2014) that is based on the correlation between predicted and measured sample values. An unnamed model developed at Pacific Northwest National Laboratory (herein called BAYEST) uses a Bayesian formulation (Eslinger et al., 2019; Eslinger et al., 2020; Eslinger and Schrom, 2016). The FREAR model uses a different Bayesian formulation (De Meutter and Hoffman, 2020; De Meutter et al., 2021; Pieter De Meutter, 2021). The performance of the three source-location models is evaluated with 100 synthetic release cases for the single xenon isotope, 133 Xe. The release cases resulted in detections in a fictitious network with 120 noble gas samplers. All three source-location models use the same sampling data. The two Bayesian models yield more accurate location estimates than the deterministic PSR model, with FREAR having slightly better location performance than BAYEST. Samplers with collection periods of 3, 6, 8, 12, and 24-h were used. Results from BAYEST show that location accuracy improves with each reduction in sample collection length. The BAYEST model is slightly better for estimating the start time of the release. The PSR model has about the same spread in start times as the FREAR model, but the PSR results have a better average start time. The Bayesian source-location algorithms give more accurate results than the PSR approach, and provide release magnitude estimates, while the base PSR model does not estimate the release magnitude. This investigation demonstrates that a reasonably dense sampling grid will sometimes yield poor location and time estimates regardless of the model. The poor estimates generally coincide with cases where there is a much larger distance between the release point and the first detecting sampler than the average sampler spacing.
Information barrier experimental: Toward a trusted and open-source computing platform for nuclear warhead verification
Trusted measurement systems are critical for the verification of future arms-control treaties that involve confirming the authenticity of nuclear warheads on the basis of their radiation signatures. Several research efforts have produced prototype systems, but their designs are typically not published in detail, making it difficult to enable trust in these devices. The Information Barrier Experimental (IBX) is a new prototype built around the Red Pitaya computing platform using passive gamma spectroscopy. It is the first such platform designed to help a broad research community study vulnerabilities and define the required specifications for a common, trusted inspection system. It is low-cost, simple to assemble, and enables comprehensive hardware and software authentication studies. The device follows a digital data acquisition approach, which significantly reduces the number of components between scintillator and spectrum output. Finally, measurements demonstrate that this approach is technically feasible and produces excellent measurement results.
Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33
Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.
Above-ground Antineutrino Detection for Nuclear Reactor Monitoring
Antineutrino monitoring of nuclear reactors has been demonstrated many times, however the technique has not as of yet been developed into a useful capability for treaty verification purposes. The most notable drawback is the current requirement that detectors be deployed underground, with at least several meters-water-equivalent of shielding from cosmic radiation. In addition, the deployment of liquid-based detector media presents a challenge in reactor facilities. We are currently developing a detector system that has the potential to operate above ground and circumvent deployment problems associated with a liquid detection media: the system is composed of segments of plastic scintillator surrounded by 6 LiF/ZnS:Ag. ZnS:Ag is a radio-luminescent phosphor used to detect the neutron capture products of lithium-6. Because of its long decay time compared to standard plastic scintillators, pulse-shape discrimination can be used to distinguish positron and neutron interactions resulting from the inverse beta decay (IBD) of antineutrinos within the detector volume, reducing both accidental and correlated backgrounds. Segmentation further reduces backgrounds by identifying the positron’s annihilation gammas, which are absent for most correlated and uncorrelated backgrounds. This work explores different configurations in order to maximize the size of the detector segments without reducing the intrinsic neutron detection efficiency. We believe this technology will ultimately be applicable to potential safeguards scenarios such as those recently described.
Variations in AmLi source spectra and their estimation utilizing the 5 Ring Multiplicity Counter
Active-mode assay systems are widely used for the safeguards of uranium items to verify compliance with the Non-Proliferation Treaty. Systems such as the Active-Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL) use americium-lithium (AmLi) neutron sources to induce fissions which are measured to determine the sample mass. These systems have historically relied on calibrations derived from well-defined standards. Recently, restricted access to standards or more difficult measurements have resulted in a reliance on modeling and simulation for the calibration of systems, which introduces potential simulation biases. Furthermore, the AmLi source energy spectra commonly used in the safeguards community do not accurately represent measurement results and the spectrum uncertainty can represent a large contribution to the total modeling uncertainty in active-mode systems.
A prototype detection system for atmospheric monitoring of xenon radioisotopes
The design of a radioxenon detection system utilizing a CdZeTe crystal and a plastic scintillator coupled to an array of SiPMs to conduct beta-gamma coincidence detection for atmospheric radioxenon monitoring, as well as the measurement of 135 Xe and 133/133m Xe, have been detailed previously. This paper presents recent measurements of 133/133m Xe and 131m Xe and the observation of conversion electrons in their coincidence spectra, as well as a 48-hour background measurement to calculate the Minimum Detectable Concentration (MDC) of radioxenon isotopes in the system. The identification of Regions of Interest (ROIs) in the coincidence spectra yielded from the radioxenon measurements, and the subsequent calculation of the MDCs of the system for 135 Xe, 133/133m Xe, and 131m Xe, are also discussed. Calculated MDCs show that the detection system preforms respectably when compared to other state of the art radioxenon detection systems and achieved an MDC of less than 1 mBq/m 3 for 131m Xe, 133 Xe, and 133m Xe, in accordance with limits set by the Comprehensive Nuclear-Test-Ban Treaty (CTBTO). Lastly, the system also provides the advantage of room temperature operation, compactness, low noise operation and having simple readout electronics.
A secure measurement unit for an inspection system used in nuclear arms-control verification
Verification of arms control treaties may require information barriers to protect sensitive data acquired during the verification process. These information barriers are commonly implemented in software, but must store and operate on data that are vulnerable to attack and tampering. Here, we present a new Secure Measurement Unit based on a modified pipeline SAR ADC architecture. The idea is to move the information barrier back into the digitization process so that prohibited data is never created. A prototype 65nm CMOS Secure Measurement Unit (SMU) was tested using U-235, U-238, Co-60, Cs-137 and Am-241 sources. Here, the prototype accurately digitized allowable signals while being immune to side-channel attacks on signals within preset forbidden regions.
Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay
Verification of the fissile (and fertile) content in fresh nuclear fuel assemblies is conducted by the IAEA to enforce the Nuclear Non-Proliferation Treaty using the UNCL (Uranium Neutron Collar — Light Water Reactor Fuel). The UNCL uses an uncorrelated AmLi neutron source to interrogate the fuel, producing a signal of coincident fission neutrons (Doubles rate) used to assay 235 U content of the fuel. The cost of producing calibration assemblies and limited availability of diverse commercial assemblies at any one time historically restricted the ability to explore the full parameter space experimentally. Monte Carlo simulations can overcome this, but introduce additional sources of uncertainty. In this work, the sensitivity of simulations and measurements to various parameters is assessed for a reference 1616 PWR assembly of uniform 3.2% enrichment. Uncertainty contributions in this evaluation include: simulated AmLi neutron source spectrum, AmLi neutron emission rate, AmLi anisotropicity, high density polyethylene (HDPE) density, the precise position of the fuel assembly within the detector, and experimentally the statistical uncertainty. The overall total systematic uncertainty estimate for the simulation of the absolute/relative Doubles rates responses are estimated to be approximately 2.0%/1.5%, and for experimental measurements systematic uncertainty reduces to 1.1%. This analysis supports further work using the relative Doubles rates in place of measurements for updating and extending the UNCL analysis methodology as systematic uncertainty is reasonably small.
A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring
The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.