Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Ignition delay time and speciation of dibutyl ether at high pressures

Dibutyl ether (DBE) is a promising biofuel due to its high cetane number (~ 100) and high volumetric energy density (31.6 MJ/L). It could either be used directly in compression ignition engines or blended with other conventional or renewable fuels. Oxidation and pyrolysis kinetics of DBE are not well known, particularly at high pressures. In this work, we have experimentally investigated the chemical kinetics of DBE in three domains: (a) ignition delay time measurements in a rapid compression machine over T = 550–650 K, P = 10, 20, 40 bar, φ = 0.5, 1; (b) ignition delay time measurements in a shock tube over T = 900–1300 K, P = 20, 40 bar, φ = 0.5, 1; (c) laser-based carbon monoxide speciation measurements in a shock tube during DBE pyrolysis and oxidation over T = 1100–1400 K, P = 20 bar. Pressure time-histories measured in RCM experiments exhibited unique 3-stage and 4-stage ignition behavior predominantly at fuel-lean conditions. Experimental data were compared with the predictions of two recent chemical kinetic models of DBE. Sensitivity analyses were carried out to identify key reactions which may have caused the discrepancy between experiments and simulations. We found that the rate of decomposition of DBE may need to be revisited to improve the oxidative and pyrolytic predictions of DBE kinetic model.

09 BIOMASS FUELS↗

Influences of upwind emission sources and atmospheric processing on aerosol chemistry and properties at a rural location in the Northeastern U.S.

Continuous real-time measurements of atmospheric aerosol with an Aerodyne high-resolution time-of-flight aerosol mass spectrometer coupled with a fast temperature-stepping thermodenuder were carried out in summer 2011 at Brookhaven National Laboratory (BNL, 40.871°N, 72.89°W) during the Department of Energy Aerosol Life Cycle Intensive Operational Period campaign. BNL was frequently downwind of emissions from the New York metropolitan area and was exposed to various combinations of anthropogenic, biogenic, and marine emissions based on air mass history. The average concentration of submicrometer aerosol (PM1) during this study was 12.6 µg m –3 with 64% of the mass being organic. Organic aerosol (OA) at BNL was found to be overwhelmingly secondary, consisting of (1) a fresher, semivolatile oxygenated organic aerosol (SV-OOA; oxygen-to-carbon ratio (O/C) = 0.54; 63% of OA mass) that was strongly influenced by transported urban plumes; (2) a regional, more aged, low-volatility OOA (LV-OOA; O/C = 0.97; 29% of OA mass) influenced by aqueous-phase processing; and (3) a nitrogen-enriched OA (NOA; nitrogen-to-carbon ratio (N/C) = 0.185; 8% of OA mass) likely composed of amine salts formed from acid-base reactions in industrial emissions. Urban emissions from the New York metropolitan areas to the W and SW in particular led to elevated PM1 mass concentration and altered aerosol composition at BNL. Transported urban plumes and local biogenic emissions likely interacted to enhance secondary organic aerosol production, primarily represented by SV-OOA. Lastly, these results suggest an important role that urban anthropogenic emissions play in affecting ambient PM concentration, composition, and physical-chemical properties at rural areas in the Northeast U.S.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of CMEs in the LASCO Field of View

A large set (16000) of coronal mass ejections (CMEs) observed during 1996-2011 was selected to study their dynamics in the LASCO field of view (LFOV). These events were selected based on the criterion that at least three height-time measurements were available for each CME. The height-time measurements included in the SOHO/LASCO catalog were used to determine velocities and accelerations of the respective CMEs at successive distances from the Sun. Next, these parameters were sorted into 30 subsamples depending on the distance from the Sun at which they were determined. The mean velocities and accelerations calculated for the successive distance-dependent subsamples of CMEs were used to study their dynamics. We demonstrate that CMEs in the LFOV manifest three distinct phases of propagation: (i) The propelling Lorentz force dominates the dynamics of CMEs in the inner (C2 LASCO) FOV, (ii) a stable propagation occurs as a result of the balance between the propelling and drag forces, (iii) the drag force dominates at the outer edge of the LFOV. When we considered different categories of CME separately, we found different acceleration distance profiles for different categories.

Michalek, G.↗

Time-resolved measurement of a shock-driven plasma target for interaction experiments between heavy ions and plasmas

To observe nonlinearity in the stopping power of a nonideal plasma for heavy ions, we are planning a beam-plasma interaction experiment using 10-100 keV/u projectiles. For the interaction experiment, a nonideal hydrogen plasma target was developed by means of a shock technique. Time-resolved spectroscopic measurements determined the temporal evolution of the electron density and temperature of the shock plasma. These data revealed that the structure behind the shock front has an appropriate spatial and temporal distribution to be used as a target. We also evaluated the temporal evolution of the Coulomb coupling constant and the degree of ionization at a fixed position where the projectiles are injected. We discuss the feasibility of the nonlinear stopping experiment by evaluating the beam-plasma coupling constant expected from the measured plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Average Molecular Rayleigh Scattering Technique for Measurement of Velocity, Denisty, Temperature, and Turbulence Intensity in High Speed Nozzle Flows

A molecular Rayleigh scattering based flow diagnostic is developed to measure time average velocity, density, temperature, and turbulence intensity in a 25.4-mm diameter nozzle free jet facility. The spectrum of the Rayleigh scattered light is analyzed using a Fabry-Perot interferometer operated in the static imaging mode. The resulting fringe pattern containing spectral information of the scattered light is recorded using a low noise CCD camera. Nonlinear least squares analysis of the fringe pattern using a kinetic theory model of the Rayleigh scattered light provides estimates of density, velocity, temperature, and turbulence intensity of the gas flow. Resulting flow parameter estimates are presented for an axial scan of subsonic flow at Mach 0.95 for comparison with previously acquired pitot tube data, and axial scans of supersonic flow in an underexpanded screeching jet. The issues related to obtaining accurate turbulence intensity measurements using this technique are discussed.

Mielke, Amy F.↗

Evidence for Dark Energy from the Cosmic Microwave Background Alone Using the Atacama Cosmology Telescope Lensing Measurements

For the first time, measurements of the cosmic microwave background radiation (CMB) alone favor cosmologies with w = -1 dark energy over models without dark energy at a 3.2-sigma level. We demonstrate this by combining the CMB lensing deflection power spectrum from the Atacama Cosmology Telescope with temperature and polarization power spectra from the "Wilkinson Microwave Anisotropy Probe. The lensing data break the geometric degeneracy of different cosmological models with similar CMB temperature power spectra. Our CMB-only measurement of the dark energy density Omega(delta) confirms other measurements from supernovae, galaxy clusters and baryon acoustic oscillations, and demonstrates the power of CMB lensing as a new cosmological tool.

Sherwin, Blake D.↗

Measurement of time dependent CP asymmetry parameters in B{sup 0} meson decays to {omega}K{sub S}{sup 0}, {eta}{sup '}K{sup 0}, and {pi}{sup 0}K{sub S}{sup 0}

We present measurements of the time-dependent CP-violation parameters S and C in the decays B{sup 0}{yields}{omega}K{sub S}{sup 0}, B{sup 0}{yields}{eta}{sup '}K{sup 0}, reconstructed as {eta}{sup '}K{sub S}{sup 0} and {eta}{sup '}K{sub L}{sup 0}, and B{sup 0}{yields}{pi}{sup 0}K{sub S}{sup 0}. The data sample corresponds to the full BABAR dataset of 467x10{sup 6} BB pairs produced at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the Stanford Linear Accelerator Center. The results are S{sub {omega}}{sub K{sub S}{sup 0}}=0.55{sub -0.29}{sup +0.26}{+-}0.02, C{sub {omega}}{sub K{sub S}{sup 0}}=-0.52{sub -0.20}{sup +0.22}{+-}0.03, S{sub {eta}{sup '}}{sub K{sup 0}}=0.57{+-}0.08{+-}0.02, C{sub {eta}{sup '}}{sub K{sup 0}}=-0.08{+-}0.06{+-}0.02, S{sub {pi}{sup 0}}{sub K{sub S}{sup 0}}=0.55{+-}0.20{+-}0.03, and C{sub {pi}{sup 0}}{sub K{sub S}{sup 0}}=0.13{+-}0.13{+-}0.03, where the first errors are statistical and the second systematic. These results are consistent with our previous measurements and the world average of sin2{beta} measured in B{sup 0}{yields}J/{psi}K{sub S}{sup 0}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long Duration Exposure Facility (LDEF) attitude measurements of the interplanetary dust experiment

The Long Duration Exposure Facility (LDEF) Interplanetary Dust Experiment (IDE) was unique in providing a time history of impacts of micron-sized particles on six orthogonal faces of LDEF during the first year in orbit. The value of this time resolved data depended on and was enhanced by the proper operation of some basic LDEF systems. Thus, the value of the data is greatly enhanced when the location and orientation of LDEF is known for each time of impact. The location and velocity of LDEF as a function of time can be calculated from the 'two-line elements' published by GSFC during the first year of the LDEF mission. The attitude of LDEF was passively stabilized in a gravity-gradient mode and a magnetically anchored viscous damper was used to dissipate roll, pitch, and yaw motions. Finally, the IDE used a standard LDEF Experiment Power and Data System (EPDS) to collect and store data and also to provide a crystal derived clock pulse (1 count every 13.1072 seconds) for all IDE time measurements. All that remained for the IDE was to provide a system to calibrate the clock, eliminating accumulative errors, and also verify the attitude of LDEF. The IDE used solar cells on six orthogonal faces to observe the LDEF sunrise and provide data about the LDEF attitude. The data was recorded by the EPDS about 10 times per day for the first 345 days of the LDEF mission. This data consist of the number of IDE counts since the last LDEF sunrise and the status of the six solar cells (light or dark) at the time of the last IDE count. The EPDS determined the time that data was recorded and includes, with each record, the master EPDS clock counter (1 count every 1.6384 seconds) that provided the range and resolution for time measurements. The IDE solar cells provided data for an excellent clock calibration, meeting their primary purpose, and the time resolved LDEF attitude measurements that can be gleaned from this data are presented.

Kassel, Philip C., Jr.↗

A novel approach to estimate emissions from large transportation networks: Hierarchical clustering-based link-driving-schedules for EPA-MOVES using dynamic time warping measures

We present that EPA-MOVES (Motor Vehicle Emission Simulator) is often integrated with traffic simulators to assess emission levels of large-scale urban networks with signalized intersections. High variations in speed profiles exist in the context of congested urban networks with signalized intersections. The traditional average-speed-based emission estimation technique with EPA-MOVES provides faster execution while underestimates the emissions in most cases because of ignoring the speed variation at congested networks with signalized intersections. In contrast, the atomic second-by-second speed profile (i.e., the trajectory of each vehicle)-based technique provides accurate emissions at the cost of excessive computational power and time. We addressed this issue by developing a novel method to determine the link-driving-schedules (LDSs) for the EPA-MOVES tool. Our research developed a hierarchical clustering technique with dynamic time warping similarity measures (HC-DTW) to find the LDS for EPA-MOVES that is capable of producing emission estimates better than the average-speed-based technique with execution time faster than the atomic speed profile approach. We applied the HC-DTW on a sample data from a signalized corridor and found that HC-DTW can significantly reduce computational time without compromising the accuracy. The developed technique in this research can substantially contribute to the EPA-MOVES-based emission estimation process for large-scale urban transportation network by reducing the computational time with reasonably accurate estimates. This method is highly appropriate for transportation networks with higher variation in speed such as signalized intersections. Lastly, experimental results show error difference ranging from 2% to 8% for most pollutants except PM 10 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy

Purpose: TOPAS (TOol for PArticle Simulation) is a particle simulation code recently developed with the specific aim of making Monte Carlo simulations user-friendly for research and clinical physicists in the particle therapy community. The authors present a thorough and extensive experimental validation of Monte Carlo simulations performed with TOPAS in a variety of setups relevant for proton therapy applications. The set of validation measurements performed in this work represents an overall end-to-end testing strategy recommended for all clinical centers planning to rely on TOPAS for quality assurance or patient dose calculation and, more generally, for all the institutions using passive-scattering proton therapy systems. Methods: The authors systematically compared TOPAS simulations with measurements that are performed routinely within the quality assurance (QA) program in our institution as well as experiments specifically designed for this validation study. First, the authors compared TOPAS simulations with measurements of depth-dose curves for spread-out Bragg peak (SOBP) fields. Second, absolute dosimetry simulations were benchmarked against measured machine output factors (OFs). Third, the authors simulated and measured 2D dose profiles and analyzed the differences in terms of field flatness and symmetry and usable field size. Fourth, the authors designed a simple experiment using a half-beam shifter to assess the effects of multiple Coulomb scattering, beam divergence, and inverse square attenuation on lateral and longitudinal dose profiles measured and simulated in a water phantom. Fifth, TOPAS’ capabilities to simulate time dependent beam delivery was benchmarked against dose rate functions (i.e., dose per unit time vs time) measured at different depths inside an SOBP field. Sixth, simulations of the charge deposited by protons fully stopping in two different types of multilayer Faraday cups (MLFCs) were compared with measurements to benchmark the nuclear interaction models used in the simulations. Results: SOBPs’ range and modulation width were reproduced, on average, with an accuracy of +1, −2 and ±3 mm, respectively. OF simulations reproduced measured data within ±3%. Simulated 2D dose-profiles show field flatness and average field radius within ±3% of measured profiles. The field symmetry resulted, on average in ±3% agreement with commissioned profiles. TOPAS accuracy in reproducing measured dose profiles downstream the half beam shifter is better than 2%. Dose rate function simulation reproduced the measurements within ∼2% showing that the four-dimensional modeling of the passively modulation system was implement correctly and millimeter accuracy can be achieved in reproducing measured data. For MLFCs simulations, 2% agreement was found between TOPAS and both sets of experimental measurements. The overall results show that TOPAS simulations are within the clinical accepted tolerances for all QA measurements performed at our institution. Conclusions: Our Monte Carlo simulations reproduced accurately the experimental data acquired through all the measurements performed in this study. Thus, TOPAS can reliably be applied to quality assurance for proton therapy and also as an input for commissioning of commercial treatment planning systems. This work also provides the basis for routine clinical dose calculations in patients for all passive scattering proton therapy centers using TOPAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A coated-wire ion-selective electrode for ionic calcium measurements

A coated-wire ion-selective electrode for measuring ionic calcium was developed, in collaboration with Teknektron Sensor Development Corporation (TSDC). This coated wire electrode sensor makes use of advanced, ion-responsive polyvinyl chloride (PVC) membrane technology, whereby the electroactive agent is incorporated into a polymeric film. The technology greatly simplifies conventional ion-selective electrode measurement technology, and is envisioned to be used for real-time measurement of physiological and environment ionic constituents, initially calcium. A primary target biomedical application is the real-time measurement of urinary and blood calcium changes during extended exposure to microgravity, during prolonged hospital or fracture immobilization, and for osteoporosis research. Potential advanced life support applications include monitoring of calcium and other ions, heavy metals, and related parameters in closed-loop water processing and management systems. This technology provides a much simplified ionic calcium measurement capability, suitable for both automated in-vitro, in-vivo, and in-situ measurement applications, which should be of great interest to the medical, scientific, chemical, and space life sciences communities.

Hines, John W.↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Online detection of airborne nanoparticle composition with mass spectrometry: Recent advances, challenges, and opportunities

Airborne nanoparticles are receiving growing attention due to their impacts on human health, air quality, and climate. Additionally, there are increasing applications of aerosol-based nanotechnology. Real-time measurement of airborne nanoparticle composition is challenging due to their small masses and the difficulties in effectively separating them from larger particles. Custom-built instruments based on mass spectrometry have been developed for nanoparticle composition, including thermal desorption-based, laser-based, and solution-based techniques. They have significantly promoted the understanding of airborne nanoparticles in the last two decades. However, they are affected by molecular fragmentation, lack of mass-resolving power, incomplete species detection, and difficulties in directly comparing to gas-phase measurements. Recent developments in atmospheric mass spectrometry provide possible solutions. Here, this review presents the potential application of these new advances to real-time measurements of the molecular nanoparticle composition and discusses the associated challenges. Such measurements present opportunities for a more comprehensive view of airborne nanoparticles and their impacts.

47 OTHER INSTRUMENTATION↗

Measurement of time-dependent CP violation in B 0 → η'K 0 decays

We present a measurement of the time-dependent CP violation parameters in B 0 → η'K 0 decays. The measurement is based on the full data sample containing 772×10 6 BB-bar pairs collected at the Υ(4S) resonance using the Belle detector at the KEKB asymmetric-energy e + e - collider. The measured values of the mixing-induced and direct CP violation parameters are: sin 2φ 1 eff = +0.68 ± 0.07 ± 0.03, A η'K 0 = +0.03 ± 0.05 ± 0.04, where the first uncertainty is statistical and the second is systematic. The values obtained are the most accurate to date. Furthermore, these results are consistent with our previous measurements and with the world-average value of sin 2φ 1 measured in B 0 → J/ψK 0 decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-Resolved Measurements Of Laser Far-Field Patterns

Computer-controlled scanning photometric instrumentation system measures intensity pattern in far field of pulsed laser as function of time during each pulse (provided that pulse is at least 1 ns long). Such measurements important in studying dynamics of laser operation: they reveal such previously unobservable phenomena as oscillations of undesired spatial modes of radiation pattern during pulse, steering of beam during pulse, and instability of intensity of laser beam. Principal advantages of system are its relatively low cost and its ability to function under normal lighting conditions without incurring damage.

Forrest, Kathrine↗

U-238-U-234-Th-230-Th-232 systematics and the precise measurement of time over the past 500,000 years

A method is presented for the high-precision measurement of the Th-230 abundance in corals by isotope-dilution mass spectrometry using techniques developed by Chen and Wasserburg (1980, 1981) and Chen et al. (1986). It is shown that 6 x 10 to the 8th atoms of Th-230 can be measured to + or - 30 percent (2 sigma) and 2 x 10 to the 10th atoms of Th-230 to + or - 2 percent. The time over which useful age data on corals can be obtained ranges from a few years to about 500 ky, with the uncertainty in age ranging from 5 y for a 180-y-old coral, to 44 y for a 8294-y-old coral, to 1.1 ky for a 123.1-ky-old coral. Ages were determined with high analytical precision for several corals that grew during high sea-level stands about 120 ky ago, supporting the view that the dominant cause of Pleistocene climate change was Milankovitch forcing.

Edwards, R. Lawrence↗

Time-Resolved Measurements of Cygnus X-ray Production Using Aerogel Cherenkov Detector

Aerogel Cherenkov Detector for Cygnus (ACD/C) has been developed to provide time-dependent x-ray spectral information from Cygnus – an intense flash x-ray source operated at the Nevada National Security Site. Time-resolved Cygnus x-ray signals were measured at three energy thresholds: 1.3 MeV (by 197 mg/cc aerogel), 1.1 MeV (by 260 mg/cc aerogel), and 0.3 MeV (by quartz). ACD/C data qualitatively suggest that the high-energy x-ray peak exists on a shorter timescale than the Cygnus voltage or current pulse. A time-dependent, x-ray spectral information can improve the understanding of the physics of dense objects radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗