Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOSTATS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Model-Free Control of Grid-Interactive Efficient Buildings Under Communication Time Delays

Grid-interactive efficient buildings (GEBs) have recently been used to enhance the reliability and stability of the electric grid through demand response (DR) programs. However, most existing DR control strategies require accurate modeling of the various building thermostatically controlled loads (TCLs) and are computationally expensive. To address these challenges, a model-free control (MFC)-based strategy has recently been introduced for coordinating and controlling GEBs. MFC is a data-enabled control strategy that is computationally efficient and does not require the analytical models of the various building equipment. In this paper, we numerically investigate the impact of communication time delays on the performance of MFC in maintaining the TCLs' temperatures within the desired comfort levels while meeting the assigned power allocation constraint.

Telsang, Bhagyashri [University of Tennessee, Knox↗

Generalized Aggregation and Coordination of Residential Loads in a Smart Community

Flexibility from residential loads presents an enormous potential to provide various services to the smart grid. In this paper, we propose a unified hierarchical framework for aggregation and coordination of various residential loads in a smart community, such as Thermostatically Controlled Loads (TCLs), Distributed Energy Storages (DESs), residential Pool Pumps (PPs), and Electric Vehicles (EVs). A central idea of this framework is a virtual battery model, which provides a simple and intuitive tool to aggregate the flexibility of distributed loads. Moreover, a multi-stage Nash-bargainingbased coordination strategy is proposed to coordinate different aggregations of residential loads for demand response. Case studies are provided to demonstrate the efficacy of our proposed framework and coordination strategy in managing peak power demand in a smart residential community.

Hao, He↗

PMU-Based Monitoring and Mitigation of Delayed Voltage Recovery Using Admittances

This project analyzes the delayed voltage recovery phenomenon by simplifying the Western Electricity Coordinating Council (WECC) composite load model using the load admittance and the thermal relay dynamics. From this analysis, a closed form expression approximating the recovery time is derived and the key load parameters impacting the behavior of voltage recovery are identified. A monitoring scheme based on the measured load admittance is then proposed to detect the onset of stalling, even in the presence of voltage oscillations, and estimate the duration of the delayed voltage recovery. A mitigation scheme utilizing smart thermostats and offline learning is also derived to ensure that the voltage recovers to the pre-contingency voltage within a specified time. Both the monitoring and mitigation schemes only need local measurements at a substation making them promising for online applications. Results for the monitoring and mitigation schemes are described in detail for the IEEE 162 bus system validating the various assumptions used for the analysis and establishing the connection between the delayed voltage recovery phenomenon and load admittance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Appliance Commitment for Household Load Scheduling

This paper presents a novel appliance commitment algorithm that schedules thermostatically-controlled household loads based on price and consumption forecasts considering users comfort settings to meet an optimization objective such as minimum payment or maximum comfort. The formulation of an appliance commitment problem was described in the paper using an electrical water heater load as an example. The thermal dynamics of heating and coasting of the water heater load was modeled by physical models; random hot water consumption was modeled with statistical methods. The models were used to predict the appliance operation over the scheduling time horizon. User comfort was transformed to a set of linear constraints. Then, a novel linear, sequential, optimization process was used to solve the appliance commitment problem. The simulation results demonstrate that the algorithm is fast, robust, and flexible. The algorithm can be used in home/building energy-management systems to help household owners or building managers to automatically create optimal load operation schedules based on different cost and comfort settings and compare cost/benefits among schedules.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Load Ensemble Control in Chance-Constrained Optimal Power Flow

Distribution system operators (DSOs) world-wide foresee a rapid roll-out of distributed energy resources. From the system perspective, their reliable and cost effective integration requires accounting for their physical properties in operating tools used by the DSO. This work describes an decomposable approach to leverage the dispatch flexibility of thermostatically controlled loads (TCLs) for operating distribution systems with a high penetration level of photovoltaic resources. Each TCL ensemble is modeled using the Markov Decision Process (MDP). The MDP model is then integrated with a chance constrained optimal power flow that accounts for the uncertainty of PV resources. Since the integrated optimization model cannot be solved efficiently by existing dynamic programming methods or off-the-shelf solvers, this paper proposes an iterative Spatio-Temporal Dual Decomposition algorithm (ST-D2). Finally, we demonstrate the merits of the proposed integrated optimization and ST-D2 algorithm on the IEEE 33-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model for Joint Probabilistic Forecast of Solar Photovoltaic Power and Outdoor Temperature

In this paper, a stochastic model is proposed for a joint statistical description of solar photovoltaic (PV) power and outdoor temperature. The underlying correlation emerges from solar irradiance that is responsible in part for both the variability in solar PV power and temperature. The proposed model can be used to capture the uncertainty in solar PV power and its correlation with the electric power consumption of thermostatically controlled loads. First, a model for solar PV power that explicitly incorporates the stochasticity due to clouds via a regime-switching process between the three classes of sunny , overcast and partly cloudy is proposed. Then, the relationship between temperature and solar power is postulated using a second-order Volterra model. This joint modeling is leveraged to develop a joint probabilistic forecasting method for solar PV power and temperature. Real-world datasets that include solar PV power and temperature measurements in California are analyzed and the effectiveness of the joint model in providing probabilistic forecasts is verified. The proposed forecasting methodology outperforms several reference methods thus portraying that the underlying correlation between temperature and solar PV power is well defined and only requires a simple lower-complexity sampling space.

14 SOLAR ENERGY↗

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of a CO 2 sorbent for indoor air cleaning applications: Effects of environmental conditions, sorbent aging, and adsorption of co-occurring formaldehyde

Indoor air cleaning systems that incorporate CO 2 sorbent materials enable HVAC load shifting and efficiency improvements. This study developed a bench-scale experimental system to evaluate the performance of a sorbent under controlled operation conditions. A thermostatic holder containing 3.15 g sorbent was connected to a manifold that delivered CO 2 -enriched air at a known temperature and relative humidity (RH). The air stream was also enriched with 0.8-2.1 ppm formaldehyde. The CO 2 concentration was monitored in real-time upstream and downstream of the sorbent, and integrated formaldehyde samples were collected at different times using DNPH-coated silica cartridges. Sorbent regeneration was carried out by circulating clean air in countercurrent. Almost 200 loading/regeneration cycles were performed in the span of 17 months, from which 104 were carried out at reference test conditions defined by loading with air at 25°C, 38% RH, and 1000 ppm CO 2 , and regenerating with air at 80°C, 3% RH and 400 ppm CO 2 . The working capacity decreased slightly from 43-44 mg CO 2 per g sorbent to 39-40 mg per g over the 17 months. The capacity increased with lower loading temperature (in the range 15-35°C) and higher regeneration temperature, between 40 and 80°C. The CO 2 capacity was not sensitive to the moisture content in the range 6-9 g/m 3 , and decreased slightly when dry air was used. Loading isothermal breakthrough curves were fitted to three simple adsorption models, verifying that pseudo-first-order kinetics appropriately describes the adsorption process. The model predicted that equilibrium capacities decreased with increasing temperature from 15 to 35°C, while adsorption rate constants slightly increased. The formaldehyde adsorption efficiency was 80%-99% in different cycles, corresponding to an average capacity of 86 ± 36 µg/g. Formaldehyde was not quantitatively released during regeneration, but its accumulation on the sorbent did not affect CO 2 adsorption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PhaseChange Material Melting in an Energy Storage Module for a Micro Environmental ControlSystem

An experimentally validated finite element model (FEM) was developed to analyze the design parameters of a latent heat storage device (LHSD) for a micro environmental control system ( μ X). The μ X provides local cooling to an office worker in a room whose thermostat setpoint has been elevated from 23.9 °C (75 °F) to 26.1 °C (79 °F) in order to reduce heating, ventilation, and air conditioning (HVAC) energy consumption. For this application, the LHSD is designed to provide ≥50 W of cooling for a full, 8.5 h workday to restore thermal comfort in the warm, 26.1 °C room. The LHSD comprises several parallel slabs of encased phase change material (PCM) with interposed airflow channels. The airflow rate is selected to obtain ≥50 W of cooling at the end of the 8.5 h operation. The LHSD exhibits a decreasing cooling rate over the 8.5 h period when a constant airflow is passed through it, indicating that more cooling is supplied during the day than the minimum 50 W required for thermal comfort. The parametric analysis explores the effects of PCM thermal conductivity, slab thickness, air channel width, and number of slabs on LHSD performance. Parametric cases are compared against each other on the basis of their required PCM mass and energy consumption.

Engineering↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Switchable client specificity in a dual functional chaperone coordinates light-harvesting complex biogenesis

The proper assembly of light-harvesting complexes (LHCs) is critical for photosynthesis and requires the biogenesis of light-harvesting chlorophylla,b-binding proteins (LHCPs) to be coordinated with chlorophyll (Chl) biosynthesis. The mechanism underlying this coordination is not well understood. Here, we show that a conserved molecular chaperone, chloroplast signal recognition particle 43-kDa protein (cpSRP43), provides a molecular thermostat that helps maintain this coordination. cpSRP43 undergoes a conformational rearrangement between a well-folded closed state and a partially disordered open state. Closed cpSRP43 is dedicated to the biogenesis of LHCPs, whereas open cpSRP43 protects multiple Chl biosynthesis enzymes from heat-induced destabilization. Rising temperature shifts cpSRP43 to the open state, enabling it to protect heat-destabilized Chl biosynthesis enzymes. Our results reveal the molecular basis of a posttranslational mechanism for the thermoadaptation of LHC biogenesis. They also demonstrate how an adenosine triphosphate–independent chaperone uses conformational dynamics to switch its activity and client selectivity, thereby adapting to different proteostatic demands under shifting environmental conditions.

Science & Technology - Other Topics↗

On the calculation of thermodynamic quantities in the Holstein model for homogeneous polynucleotides

The dynamics of a system for different types of polarons, i.e., in polythymine nucleotides (large-radius polaron), in polyadenine fragments (small-radius polaron), and in polyguanine DNA (intermediate case) at different thermostat temperatures are calculated using the semi-classical Holstein model. The temperature dependences of the thermodynamic equilibrium values of the total energy, the energy of an excess charge, and the electronic heat capacity have been obtained. For all polaron types, the peak of the electronic heat capacity dependence on temperature separates two modes (polaron and delocalized state). The electronic part of the energy is estimated in the high-temperature limit. In all cases, the electron heat capacity at high temperatures decreases in inverse proportion to the square of the temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic Equation for the Density Matrix of Atoms in the Field of a Broadband One-Photon Packet Taking into Account the Non-Wiener Dynamics

We have derived the quantum master kinetic equation for the density matrix of an atomic system in the field of a narrow-beam one-photon broadband packet in the conditions when the latter plays the role of a thermostat. This equation takes into account the Stark interaction of atoms with the broadband field of surroundings of the system, which are in the state with zero photon number density, as well as the interaction of broadband fields at the atomic system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

N.N. Bogoliubov’s contribution to nonequilibrium statistical mechanics (1937–1945)

It is shown that many important and still relevant results in the field of nonequilibrium statistical mechanics were derived by Bogoliubov (jointly with N.M. Krylov) early in the prewar years and were completely published in a still insufficiently known monograph of 1945. Among these findings were the concept of time hierarchy for stochastic evolution, the concept of quasi-averages that remove symmetry relative to time inversion, and the mechanism of dynamic relaxation of a physical object in a thermostat.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

(ħ, k)-Dynamics as some generalization of equilibrium quantum statistical mechanics

We show that the quantum statistical mechanics (QSM) describing quantum and thermal properties of objects has only the sense of a particular semiclassical approximation. We propose a more general (than QSM) micro description of objects in a heat bath taken into account a vacuum as an object environment; we call it (ħ, k )-dynamics (ħkD ). We construct a new model of thermostat, namely, a quantum heat bath and study its properties including the cases of a “cold” and “thermal” vacua. We introduce a new generative operator, Schroedingerian, or stochastic action operator, and show its fundamental role in the determination such macro-quantities as internal energy, effective temperature, and effective entropy. We establish that in ħkD the ratio of effective action to effective entropy at zero temperature equals the universal constant ħ /2 k. This result corresponds to experimental data taken recently under studying of a new matter state—nearly perfect fluid.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modification of Optical Characteristics of a Polymer Composite Material under Irradiation

Polymer composites based on polystyrene and modified SiO{sub 2} are synthesized. Effect of the SiO{sub 2} concentration on the surface (thermostatic) properties of the composites is analyzed. Surfaces of composites with different SiO{sub 2} concentrations are microscopically studied. Minor amounts of spherical agglomerates are obtained at relatively high SiO{sub 2} concentrations, and the size of the agglomerates may amount to 80 μm at a SiO{sub 2} concentration of 30 wt %. Variations in the integral absorbance of solar radiation are studied for the polymer composites irradiated with vacuum-UV radiation at a temperature of 125°C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coarse-grained explicit-solvent molecular dynamics simulations of semidilute unentangled polyelectrolyte solutions

In this study, we present results from explicit-solvent coarse-grained molecular dynamics (MD) simulations of fully charged, salt-free, and unentangled polyelectrolytes in semidilute solutions. The inclusion of a polar solvent in the model allows for a more physical representation of these solutions at concentrations, where the assumptions of a continuum dielectric medium and screened hydrodynamics break down. The collective dynamic structure factor of polyelectrolytes, S(q, t), showed that at q > q*, where q* = 2π/ξ is the polyelectrolyte peak in the structure factor S(q) and ξ is the correlation length, the relaxation time obtained from fits to stretched exponential was $\tau$ KWW ~ q -3 , which describes unscreened Zimm-like dynamics. This is in contrast to implicit-solvent simulations using a Langevin thermostat where $\tau$ KWW ~ q -2 . At q < q*, a crossover region was observed that eventually transitions to another inflection point $\tau$ KWW ~ q -2 at length scales larger than ξ for both implicit- and explicit-solvent simulations. The simulation results were also compared to scaling predictions for correlation length, ξ ~ c$-½\atop{p}$, specific viscosity, η sp ~ c$½\atop{p}$, and diffusion coefficient, D ~ c$0\atop{p}$, where c p is the polyelectrolyte concentration. The scaling prediction for ξ holds; however, deviations from the predictions for η sp and D were observed for systems at higher c p , which are in qualitative agreements with recent experimental results. This study highlights the importance of explicit-solvent effects in molecular dynamics simulations, particularly in semidilute solutions, for a better understanding of polyelectrolyte solution behavior.

36 MATERIALS SCIENCE↗

Potential Demand Reduction from Buildings in a Simulated Utility

The availability of large-area sensing, scalable algorithms, and high-performance computing has enabled the possibility of urban-scale building energy modeling using new methods not limited to the scalability of manual building energy model creation or retrieval of county-by-county tax assessor’s data. Automatic Building detection and Energy Model creation (AutoBEM) has created 178,368 building energy models for the Electric Power Board (EPB) of Chattanooga, TN, and compared simulation performance to 15-minute data from each building. These models leverage several data sources (e.g. imagery, GIS, utility), software tools to extract building properties (e.g. footprint, height, façade type, window-to-wall ratio, occupancy, building type), simulate at scale on two of the world’s #1 fastest supercomputers, and provide web-based visual analytics.Grid-interactive efficient buildings offer the potential to reduce utility and rate-payer energy costs during each calendar month’s hour of critical generation – when the least efficient, most costly, and often dirtiest generation assets must be brought online. In this paper, EnergyPlus is used to simulate over 150,000 buildings to assess the technical potential of utility-controlled smart thermostats. This is analyzed under a couple scenarios leveraging buildings as thermal batteries via pre-conditioning to coast through peak hours. Results are provided in box and whisker plots assessing the distribution of peak demand reduction at the utility-scale along with breakouts of energy and demand savings by building type and vintage.

Bass, Brett↗