Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Experimental and Computational Studies of the Production of 1,3-Butadiene from 2,3-Butanediol Using SiO2-Supported H3PO4 Derivatives

Silica-supported phosphoric acid and metal phosphate catalyzed 1,3-butadiene (BDE) production from 2,3-butanediol (2,3-BDO) was studied using experimental and computational techniques. The catalyst was initially tested in a continuous flow reactor using commercially available 2,3-BDO, leading to maximum BDE yields of 63C%. Quantum chemical mechanistic studies revealed 1,2-epoxybutane is a kinetically viable and thermodynamically stable intermediate, supported by experimental demonstration that this epoxide can be converted to BDE under standard reaction conditions. Newly proposed E2 and SN2' elementary steps were studied to rationalize the formation of BDE and all detected side-products. Additionally, using quantum mechanics/molecular mechanics (QM/MM) calculations, we modeled silica-supported phosphate catalysts to study the effect of the alkali metal center. Natural population analysis showed that phosphate oxygen atoms are more negatively charged in CsH2PO4/SiO2 than in H3PO4/SiO2. In combination with temperature-programmed desorption experiments using CO2, the results of this study suggest that the improved selectivity achieved when adding the metal center is related to an increase in the basicity of the catalyst.

butadiene↗

Steam generator model design parameter sensitivity study for small modular reactor system

Here, this study focuses on design parameter sensitivity studies pertaining to several Once-Through Steam Generator (OTSG) model cases both with and without a riser using python and advanced risk assessment and optimization tool, i.e. Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), to support a Small Modular Reactor (SMR) system. The presented Steam Generator (SG) python-based model is a mathematical representation of a steam-generating unit for a Pressurized Water Reactor (PWR)-type SMR system, including fluid flow and heat transfer equations, models, and correlations. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system, such as the Heat Transfer Coefficient (HTC), Reynolds number, Nusselt number, and heat transfer performance. Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in the input parameters. By using RAVEN, detailed design parametric sensitivity studies. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10 % relative changes) for 600 samples. The analysis results give valuable insights into SG system performance, and provide justification for further research and development such as optimized sensor placement, design verification, validation, and optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NSAID use and clinical outcomes in COVID-19 patients: a 38-center retrospective cohort study

Abstract Background Non-steroidal anti-inflammatory drugs (NSAIDs) are commonly used to reduce pain, fever, and inflammation but have been associated with complications in community-acquired pneumonia. Observations shortly after the start of the COVID-19 pandemic in 2020 suggested that ibuprofen was associated with an increased risk of adverse events in COVID-19 patients, but subsequent observational studies failed to demonstrate increased risk and in one case showed reduced risk associated with NSAID use. Methods A 38-center retrospective cohort study was performed that leveraged the harmonized, high-granularity electronic health record data of the National COVID Cohort Collaborative. A propensity-matched cohort of 19,746 COVID-19 inpatients was constructed by matching cases (treated with NSAIDs at the time of admission) and 19,746 controls (not treated) from 857,061 patients with COVID-19 available for analysis. The primary outcome of interest was COVID-19 severity in hospitalized patients, which was classified as: moderate, severe, or mortality/hospice. Secondary outcomes were acute kidney injury (AKI), extracorporeal membrane oxygenation (ECMO), invasive ventilation, and all-cause mortality at any time following COVID-19 diagnosis. Results Logistic regression showed that NSAID use was not associated with increased COVID-19 severity (OR: 0.57 95% CI: 0.53–0.61). Analysis of secondary outcomes using logistic regression showed that NSAID use was not associated with increased risk of all-cause mortality (OR 0.51 95% CI: 0.47–0.56), invasive ventilation (OR: 0.59 95% CI: 0.55–0.64), AKI (OR: 0.67 95% CI: 0.63–0.72), or ECMO (OR: 0.51 95% CI: 0.36–0.7). In contrast, the odds ratios indicate reduced risk of these outcomes, but our quantitative bias analysis showed E-values of between 1.9 and 3.3 for these associations, indicating that comparatively weak or moderate confounder associations could explain away the observed associations. Conclusions Study interpretation is limited by the observational design. Recording of NSAID use may have been incomplete. Our study demonstrates that NSAID use is not associated with increased COVID-19 severity, all-cause mortality, invasive ventilation, AKI, or ECMO in COVID-19 inpatients. A conservative interpretation in light of the quantitative bias analysis is that there is no evidence that NSAID use is associated with risk of increased severity or the other measured outcomes. Our results confirm and extend analogous findings in previous observational studies using a large cohort of patients drawn from 38 centers in a nationally representative multicenter database.

60 APPLIED LIFE SCIENCES↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Specialty chemicals production case study: Economic analysis of modular chemical process intensification versus conventional stick‐built approaches

Abstract The beneficial synergies of chemical process intensification and plant modularization present a unique step‐wise advancement opportunity for many chemical manufacturers, but economic case studies are needed to raise awareness of such opportunities. The primary objective of this case study is to better understand the business case economics of a specialty chemical plant using modular chemical process intensification (MCPI), by comparing it with that of a conventional stick‐built (CSB) plant that produces the same product at the same production capacity. When comparing MCPI against CSB approaches for a plant project strategy decision, analysts should thoroughly understand and model the differences and similarities in scope bases. The MCPI approach for this case study benefitted from dramatic reductions in capital expenditures (CAPEX). A sizeable reduction in plant spatial volume likely explains some of these reductions. Sizeable operational expenditure (OPEX) reductions with the MCPI plant appear to be associated with the reduced operator staffing required from converting a labor‐intensive batch process into an automated, continuous flow process. Traditional project investment economic measures strongly favored the MCPI case for the design, construction, and operation of the specialty chemical plant. The net present value for the MCPI case was nearly twice that for the CSB case over a ten‐year period, and the payback period for the CSB case was nearly five times longer than that of the MCPI case. The opinion‐based perspective of the study participant identified significant contributors to superior MCPI economic performance for this case study. With the two conditions of low MCPI CAPEX and high product profit margin, economic analysis indicates that incorporation of a backup MCPI train, for operational redundancy when downtime occurs, is a very beneficial strategy.

O'Connor, James T.↗

Nanosecond time-resolved infrared spectroscopy for the study of electron transfer in photosystem I

Abstract Microsecond time-resolved step-scan FTIR difference spectroscopy was used to study photosystem I (PSI) from Thermosynechococcus vestitus BP-1 ( T. vestitus, formerly known as T. elongatus ) at 77 K. In addition, photoaccumulated (P700 + –P700) FTIR difference spectra were obtained at both 77 and 293 K. The FTIR difference spectra are presented here for the first time. To extend upon these FTIR studies nanosecond time-resolved infrared difference spectroscopy was also used to study PSI from T. vestitus at 296 K. Nanosecond infrared spectroscopy has never been used to study PSI samples at physiological temperatures, and here it is shown that such an approach has great value as it allows a direct probe of electron transfer down both branches in PSI. In PSI at 296 K, the infrared flash-induced absorption changes indicate electron transfer down the B- and A-branches is characterized by time constants of 33 and 364 ns, respectively, in good agreement with visible spectroscopy studies. These time constants are associated with forward electron transfer from A 1 – to F X on the B- and A-branches, respectively. At several infrared wavelengths flash-induced absorption changes at 296 K recover in tens to hundreds of milliseconds. The dominant decay phase is characterized by a lifetime of 128 ms. These millisecond changes are assigned to radical pair recombination reactions, with the changes being associated primarily with P700 + rereduction. This conclusion follows from the observation that the millisecond infrared spectrum is very similar to the photoaccumulated (P700 + –P700) FTIR difference spectrum.

59 BASIC BIOLOGICAL SCIENCES↗

Results of an interlaboratory study on the working curve in vat photopolymerization II: Towards a standardized method

The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.

36 MATERIALS SCIENCE↗

Preliminary investigation of 48 V-labeled VO(acac) 2 for cancer imaging: An initial proof-of-concept study

In this preliminary study, a procedure for synthesizing novel PET radiotracer vanadium-48-labeled-vanadyl acetylacetonate was developed, including radioisotope production via cyclotron, separation of 48 V, chelation as 48 VO(acac) 2 , and assessment through in vitro cellular studies. We employed the beam-stop setup in a cyclotron as the target holder to irradiate titanium foils in the reaction of nat Ti (p,n) 48 V. The radioisotope production rate was 4.84 ± 0.67 μCi/μA-h. Overall radiochemical yield was 12.86 ± 0.51% with gamma-ray spectroscopy showing no detectable contaminant peaks. HPLC of 48 VO(acac) 2 showed a retention time (1:48) corresponding closely to that (1:50) of commercial VO(acac) 2 , verifying the successful synthesis of 8VO(acac) 2 . In vitro cellular studies demonstrated radiotracer uptake and saturation around 0.48 nM. These studies pave the way for improving methodologies and in vivo experiments, including imaging studies, in future investigations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

An experimental study on round-trip efficiency of a preheating control with a medium office building

The interactions between building energy efficiency and demand response (DR) with buildings may complicate their impacts on the electricity grid and buildings, yet those interactions are not well understood. This work fills this gap by presenting an experimental study that quantifies the effects of DR on building energy efficiency. Unlike existing studies, this work 1) investigates the uncertainty levels when assessing the effects of DR; 2) studies the impact of rooftop heat pumps with direct expansion refrigerant-to-air coils on the round-trip efficiency. Specifically, we considered a medium office building (~1860 m 2 ), which is served by rooftop units, located in eastern Washington State. We performed preheating control tests during typical heating days in the year 2022 and compared the building’s energy consumption during the testing days to that during normal operation days under similar weather conditions. To understand how well those normal operation days represent the baseline for the assessment, the relationship between the energy performance of this building and weather conditions was also studied. Experimental results reveal that the round-trip efficiency (i.e., the ratio of discharging energy output from the building to charging energy input into the building) was between 0.16 and 0.92. The results show that significant energy loss may occur during the preheating process. Finally, it also suggests a significant correlation between the energy efficiency of the studied building under the preheating control and the outdoor temperature; and a highly nonlinear relationship between the zone temperature changing rate and the weather condition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar cities: A case study analysis of city-level enablers of expanded solar energy access

Rooftop solar photovoltaic (PV) adoption can benefit households by reducing electricity bills and enhancing energy resiliency. Low and moderate-income (LMI) households have been less likely to adopt PV and experience these benefits in the United States than higher-income households. Adopter income trends are often explored through quantitative analysis with limited explanatory power. Our quantitative analysis only explains around one-third of city-level variation in LMI adoption trends through socioeconomic factors such as median home values and income inequality and PV market factors such as cumulative adoption and incentives. We implement semi-structured interviews in three case studies of cities with relatively high rates of LMI PV adoption to better understand the factors that explain PV adopter income trends. The case studies partly reiterate findings from quantitative analysis, such as the role of PV incentives. The case studies reveal a broader set of LMI adoption drivers that are missed in quantitative analyses. The case studies show how city contexts can affect LMI adoption, such as the role of supportive city governments. The case studies also reveal the importance of partnerships, such as partnerships between city governments and state LMI PV program implementers. Finally, interviewees emphasized the importance of building trust among prospective LMI PV adopters. Interviewees suggested that partnerships, outreach, and consumer protection measures were crucial to building trust in PV installers among LMI households.

Adoption↗

Stability study of aqueous foams under high-temperature and high-pressure conditions relevant to Enhanced Geothermal Systems (EGS)

In Enhanced Geothermal System (EGS) hydraulic fracturing is carried out by injecting cold water into deep Hot Dry Rocks (HDR) under carefully controlled conditions to create new or reopen existing fractures. Water-based fracturing fluids demonstrate some challenges including immense quantity of water usage, water sensitivity of the formations, water blocking, and lack of proppant carrying capacity and transportation. Thus, an alternative is to use foam-based fracturing fluid which offers potential advantage over conventional water-based fracturing fluid such as minimum water usage, reduced wellbore damage, high proppant carrying capacity, and less environmental damage. However, foams are complex mixture of gaseous phase and liquid phase which are thermodynamically unstable at downhole conditions, and their stability can decrease over time due to liquid drainage, bubble coarsening, and coalescence. This paper shows laboratory experiments executed to study foam stability at high temperature (200°C) and high pressure (6.9MPa) conditions which simulates the geothermal environment. Foam stability was characterized by half-life of foam, which is defined as the time taken by the foam to decreases by 50% of its original height due to drainage. In this paper, two types of gaseous phases, nitrogen (N 2 ) and carbon dioxide (CO 2 ) were investigated. Also, based on successful practice of foam-based fracturing fluid in oil and gas industries, four surfactants, including Alpha olefin sulfonate (AOS), Sodium dodecyl sulfonate (SDS), Tergitol™ (NP – 40), and Cetyltrimethylammonium chloride (CTAC) at optimum concentration of 1wt.% were tested for best stability performance. In addition, different stabilizing agents including guar gum, bentonite clay, crosslinker, silicon dioxide nanoparticles (SiO 2 ), graphene oxide (GO) were also studied. Experimental results showed that N 2 foams were more stable than CO 2 foams. It was observed that foam half-life decreased with the increase in temperature. Among all the surfactants, AOS foams showed the most promising thermal stability at high temperatures. Moreover, with the addition of stabilizing agents, foam's half-life was enhanced. Stabilizing agents such as crosslinker and GO dispersion showed the most stable foams with half-life recorded at 20min and 17min, respectively, at 200°C and 6.9MPa. Finally, pressure also showed a positive effect on foam stability; with increased pressure, foam half-life was increased. Based on the experimental data, analytical models for the effect of temperature and pressure were developed, considering foam degradation is a first-order kinetic reaction that linearly depends on the foam drainage mechanism. The effect of temperature on foam half-life was studied as an exponential decay model. In this model, foam half-life is a function of drainage rate constant (D A ) and activation energy (E a ) of the foam system. The effect of pressure on foam half-life was found to obey a power-law model where an increase in pressure showed an increase in foam half-life. Furthermore, a linear relation was studied for the effect of pressure on foam activation energy and drainage rate. Then the combined effects of temperature and pressure were studied, which yielded an analytical model to predict the foam stabilities in terms of half-life for different foam compositions. In conclusion, this research indicates that with an appropriate selection of surfactants and stabilizing agents, it is possible to obtain stable foams, which could replace conventional water fracturing fluid under EGS conditions.

15 GEOTHERMAL ENERGY↗

Geological study of an outburst flood event in the upper Yangtze River and risk of similar extreme events

Here, outburst flood sediments are studied on the upper course of the Yangtze River (known as the Jinsha River) where is a key region for the development of hydroelectric power. As the history and magnitude of outburst flooding in this stretch of the Jinsha River during historic times has remained largely undocumented, we have endeavored as part of this study to conduct field investigations into, and provide numerical dating (using OSL and 14 C dating techniques) of outburst flood evidence found in the First Bend area of the Yangtze River. Carbonized nutshells and charcoal from the ancient settlement yielded 14 C ages that precisely pinpointed an outburst flood event ~1200–1300 cal yr BP, during China's Tang Dynasty (618–907 CE). However, OSL ages using the minimum age model for all outburst flood samples ranged from 9.1 to 1.8 ka, which was ~0.5–7.8 ka older than the 14 C-dated outburst flood. This discrepancy suggests a potential overestimation of quartz age when dating outburst flood sediments from the Holocene period. Furthermore, using 2D hydraulic modeling, we estimated the magnitude of the aforementioned outburst flood, revealing a reconstructed peak flow discharge of 51,000–55,300 m 3 /s. This discharge was three times greater than the 10,000-year flood for the hydroelectric power station nearest to the study area. Our study underscores the significant role of combining archaeological and geological evidence in enhancing paleoflood hydrology research. Through a multidisciplinary approach, our findings emphasize the importance of paleoflood hydrology studies in comprehending both the latent and catastrophic flood risks in alpine mountain areas amid the context of global warming.

14C dating↗

State-of-the-art and review of condensation heat transfer for small modular reactor passive safety: Computational studies

The small modular reactor (SMR) is a promising option with added safety features, economical manufacturing, reliable parts, portability, and scalable energy capacity that emits no greenhouse gas during its operating lifespan. The SMR safety systems, however, need to be evaluated for design and licensing. Thus, they require the verification and validation of the physics models and correlations. This study focuses on state-of-the-art condensation heat transfer analysis and a review of previous studies related to the passive containment cooling system (PCCS) of a SMR. In the PCCS of a SMR, due to its smaller size containment, filmwise condensation is dominant and therefore emphasized in this study. Furthermore, previous condensation heat transfer studies for PCCSs did not make the SMR the primary focus, so a critical review for formulating the state-of-the-art is necessary. A previous review covered experimental condensation heat transfer studies with a brief overview of associated test facilities and empirical correlations. This review covers the empirical, resistance-layer and theoretical (numerical and commercial CFD) approaches.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of grain size and porosity on cladding failure in high-burnup UO 2 : A sensitivity and uncertainty study

Isotopic taggants are being studied to aid in the provenance assessment of nuclear materials. However, these taggants must be selected such that they do not adversely affect fuel performance during normal operation or accident scenarios. Taggants are known to affect the fuel’s grain size and porosity. In the work described in this paper, the BISON fuel performance code was used to assess the potential effects of taggants (i.e., grain size and porosity) on fuel rod behavior and cladding failure during a high-burnup, large-break loss-of-coolant accident. Here, 281 individual fuel rods from the same reactor core were modeled for a sensitivity study, a parametric study, and uncertainty quantification. The cladding failure predictions often exhibited stochastic behavior. After additional study, it was found that the cladding failure model is highly sensitive to residual error inherent to numerical approximation solvers. Some strategies to mitigate this sensitivity are discussed. The study found no relationship between known taggant effects and cladding failure status. However, taggants were found to affect the time and location of failure in certain rods. In conclusion, future work to continue investigating and validating these findings is briefly discussed.

Doped UO 2↗

Margin to onset of nucleate boiling and flow instability studies for preliminary MITR design-demonstration element thermal-hydraulics

This study covers the onset of flow instability (OFI) preliminary results obtained from leveraging correlations, in addition to the preliminary thermal hydraulics results such as pressure, flow velocity, temperature, and oxide layer over the design demonstration experiment (DDE) for the Massachusetts Institute of Technology Reactor (MITR). Current computational fluid dynamics (CFD) models in fluid structure interaction (FSI) have added the capability of assessing margins to onset of nucleate boiling (ONB). This study initiates the capability to model the margin to OFI and ONB presented for the MITR. Such study is supportive of the United States High Performance Research Reactor (USHPRR) program. Previous studies provided preliminary thermal-hydraulic and mechanical analyses of the hydrodynamic effects in the MITR DDE under conservative approximations for plate power distribution. In conclusion, this study focuses on providing insights into the OFI future research direction optimizing the transport of thermal energy, mass-flow rates, flow-channel geometries, and boundary conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗