Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Controlled Pyroshock Test Transients Can Be Used To Better Match Operational Shock Transients and Reduce Artificial Pyroshock Test Failures [Slides]

Shock analysis is typically done via SRS (shock response spectrum). Oftentimes shock analysis is not performed because most loads specifications only supply SRS requirements with no representative shock transients that can be used for analysis. SRS analysis is too conservative. There is no structural dynamics involved as all modes are assumed to have peak responses simultaneously and in-phase with each other. It is possible that all other loads and combination of loads show the design to be good, whereas SRS analysis (1000 g’s are involved) results may require redesign. Multiple shock transients can satisfy a SRS, yet most loads documents don’t provide a representative shock transient that could be used for shock analysis. Shock testing is less common than harmonic and random vibration testing. Engineers typically go into shock tests with very little knowledge of what to expect. A pass/fail type of approach with very little engineering done to prepare for the test or to control the type of shock transient is used. Most engineers will not model the shock test fixture due to lack of knowledge about the details of the test setup. Shock analysis and testing is often an open loop type situation with no test setup modeling, no test correlation, and no control over the test shock transient. In this work, if we can create applied test force transient that comes close to matching calculated force transient then a more reasonable acceleration transient will be created at the test reference accelerometer that better matches operational shocks.

42 ENGINEERING↗

Frequency–wavenumber spectral analysis of spatio-temporal flows

We propose a fully spatio-temporal approach for identifying spatially varying modes of oscillation in fluid dynamics simulation output by means of multitaper frequency–wavenumber spectral analysis. One-dimensional spectrum estimation has proven to be a valuable tool in the analysis of turbulence data applied spatially to determine the rate of energy transport between spatial scales, or temporally to determine frequencies of oscillatory flows. It also allows for the quantitative comparison of flow characteristics between two scenarios using a standard basis. It has the limitation, however, that it neglects coupling between spatial and temporal structures. Two-dimensional frequency–wavenumber spectral analysis allows one to decompose waveforms into standing or travelling variety. The extended higher-dimensional multitaper method proposed here is shown to have improved statistical properties over conventional non-parametric spectral estimators, and is accompanied by confidence intervals which estimate their uncertainty. Multitaper frequency–wavenumber analysis is applied to a canonical benchmark problem, namely, a direct numerical simulation of von Kármán vortex shedding off a square wall-mounted cylinder with two inflow scenarios with matching momentum-thickness Reynolds numbers $Re_{\unicode[STIX]{x1D703}}\approx 1000$ at the obstacle. Frequency–wavenumber analysis of a two-dimensional section of these data reveals that although both the laminar and turbulent inflow scenarios show a turbulent $-5/3$ cascade in wavenumber ( $\unicode[STIX]{x1D708}$ ) and frequency ( $f$ ), the flow characteristics differ in that there is a significantly more prominent discrete harmonic oscillation near $(f,\unicode[STIX]{x1D708})=(0.2,0.21)$ in wavenumber and frequency in the laminar inflow scenario than the turbulent scenario. This frequency–wavenumber pair corresponds to a travelling wave with velocity near one near the centre path of the vortex street.

Geoga, Christopher J. (ORCID:0000000250604799)↗

The gas-rich circumbinary disk of HR 4049. I. A detailed study of the mid-infrared spectrum

We present a detailed analysis of the mid-infrared spectrum of the peculiar evolved object HR 4049. The full Spitzer-IRS high-resolution spectrum shows a wealth of emission with prominent features from CO{sub 2} and H{sub 2}O and possible contributions from HCN and OH. We model the molecular emission and find that it originates from a massive (M ≳ 8 × 10{sup –3} M {sub ☉}), warm (T {sub ex} ≈ 500 K) and radially extended gas disk that is optically thick at infrared wavelengths. We also report less enrichment in {sup 17}O and {sup 18}O than previously found and a comparison of the Spitzer observations to earlier data obtained by the Short Wavelength Spectrometer on board the Infrared Space Observatory reveals that the CO{sub 2} flux has more than doubled in 10 yr time, indicating active and ongoing chemical evolution in the circumbinary disk. If the gas originates from interaction between the stellar wind and the dust, this suggests that the dust could be oxygen-rich in nature. The molecular gas plays a crucial role in the thermal properties of the circumbinary disk by allowing visible light to heat the dust and then trapping the infrared photons emitted by the dust. This results in higher temperatures and a more homogeneous temperature structure in the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the U-235 Content of Concreted Waste Drums

A challenging assay situation recently arose, whereby the fissile (i.e. total plutonium plus U-235) content of a population of 164 historical waste drums containing concrete needed to be measured, to comply with nuclear safety limits for transport to, and interim storage within, an Engineered Drum Store. BIL Solutions Ltd has developed a new methodology for measurement of the U-235 content of these 'concrete' drums, because the approach normally used by the in-situ Drum Monitors was found to be overly pessimistic. Initial investigations indicated significant quantities of uranium were present in these drums (but negligible plutonium), mixed with Np-237 and / or Ra-226. These initial measurements also indicated that the uranium was likely to be depleted in enrichment. The U-235 content was therefore determined by measuring the U-238 mass via the passive coincident neutron emission, and combining this with the U-235 and U-238 isotopic abundances, obtained by analysis of a gamma spectrum. Of the uranium isotopic analysis codes available, the FRAM (Fixed energy, Response function Analysis with Multiple efficiencies) software was selected as being most suitable for this application. A wide gamma-ray energy range is used (i.e. 120 keV to 1200 keV) which was considered more likely to yield results when there is significant attenuation. The software is also user configurable, enabling interferences from the other radionuclides present (i.e. Np-237 and Ra-226) to be accounted for. A series of test measurements were performed with well-characterised uranium sources attenuated by concrete shielding, to gain confidence in the performance of FRAM under such conditions. These test measurements indicated that FRAM was able to correctly determine the enrichment of heavily shielded uranium. The new U-235 measurement methodology was then applied to the population of concrete drums; successfully yielding U-235 results despite the dense waste matrix and significant interference from Np-237 and / or Ra-226. The U-235 mass results obtained were significantly more accurate than those that would have been obtained had the traditional approach (i.e. transmission corrected 186 keV count rate) been used, facilitating safe transport and storage of the drums. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

HIGH-RESOLUTION SPECTROSCOPY DURING ECLIPSE OF THE YOUNG SUBSTELLAR ECLIPSING BINARY 2MASS 0535-0546. II. SECONDARY SPECTRUM: NO EVIDENCE THAT SPOTS CAUSE THE TEMPERATURE REVERSAL

We present high-resolution optical spectra of the young brown dwarf eclipsing binary 2M0535-05, obtained during eclipse of the higher-mass (primary) brown dwarf. Combined with our previous spectrum of the primary alone (Paper I), the new observations yield the spectrum of the secondary alone. We investigate, through a differential analysis of the two binary components, whether cool surface spots are responsible for suppressing the temperature of the primary. In Paper I, we found a significant discrepancy between the empirical surface gravity of the primary and that inferred via fine analysis of its spectrum. Here we find precisely the same discrepancy in surface gravity, both qualitatively and quantitatively. While this may again be ascribed to either cool spots or model opacity errors, it implies that cool spots cannot be responsible for preferentially lowering the temperature of the primary: if they were, spot effects on the primary spectrum should be preferentially larger, and they are not. The T{sub eff}'s we infer for the primary and secondary, from the TiO-{epsilon} bands alone, show the same reversal, in the same ratio, as is empirically observed, bolstering the validity of our analysis. In turn, this implies that if suppression of convection by magnetic fields on the primary is the fundamental cause of the T{sub eff} reversal, then it cannot be a local suppression yielding spots mainly on the primary (though both components may be equally spotted), but a global suppression in the interior of the primary. We briefly discuss current theories of how this might work.

79 ASTRONOMY AND ASTROPHYSICS↗

Stellar parameters and accretion rate of the transition disk star HD 142527 from X-shooter

HD 142527 is a young pre-main-sequence star with properties indicative of the presence of a giant planet and/or a low-mass stellar companion. We have analyzed an X-Shooter/Very Large Telescope spectrum to provide accurate stellar parameters and accretion rate. The analysis of the spectrum, together with constraints provided by the spectral energy distribution fitting, the distance to the star (140 ± 20 pc), and the use of evolutionary tracks and isochrones, led to the following set of parameters: T{sub eff} = 6550 ± 100 K, log g = 3.75 ± 0.10, L{sub *}/L{sub ☉} = 16.3 ± 4.5, M{sub *}/M{sub ☉} = 2.0 ± 0.3, and an age of 5.0 ± 1.5 Myr. This stellar age provides further constraints to the mass of the possible companion estimated by Biller et al., being between 0.20 and 0.35 M{sub ☉}. Stellar accretion rates obtained from UV Balmer excess modeling and optical photospheric line veiling, and from the correlations with several emission lines spanning from the UV to the near-IR, are consistent with each other. The mean value from all previous tracers is 2 (±1) × 10{sup –7} M{sub ☉} yr{sup –1}, which is within the upper limit gas flow rate from the outer to the inner disk recently provided by Cassasus et al.. This suggests that almost all gas transferred between both components of the disk is not trapped by the possible planet(s) in between but fall onto the central star, although it is discussed how the gap flow rate could be larger than previously suggested. In addition, we provide evidence showing that the stellar accretion rate of HD 142527 has increased by a factor ∼7 on a timescale of 2 to 5 yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Supersymmetric Higgs Bosons and Beyond

We consider supersymmetric models that include particles beyond the Minimal Supersymmetric Standard Model (MSSM) with masses in the TeV range, and that couple significantly to the MSSM Higgs sector. We perform a model-independent analysis of the spectrum and couplings of the MSSM Higgs fields, based on an effective theory of the MSSM degrees of freedom. The tree-level mass of the lightest CP-even state can easily be above the LEP bound of 114 GeV, thus allowing for a relatively light spectrum of superpartners, restricted only by direct searches. The Higgs spectrum and couplings can be significantly modified compared to the MSSM ones, often allowing for interesting new decay modes. We also observe that the gluon fusion production cross section of the SM-like Higgs can be enhanced with respect to both the Standard Model and the MSSM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rotational band structure in Mg 32

There is significant evidence supporting the existence of deformed ground states within the neutron-rich N ≈ 20 neon, sodium, and magnesium isotopes that make up what is commonly called the “island of inversion.” However, the rotational band structures, which are a characteristic fingerprint of a rigid nonspherical shape, have yet to be observed. Here, in this work, we report on a measurement and analysis of the yrast (lowest lying) rotational band in 32 Mg up to spin I = 6 + produced in a two-step projectile fragmentation reaction and observed using the state-of-the-art γ-ray tracking detector array, GRETINA (γ-ray energy tracking in-beam nuclear array). Large-scale shell-model calculations using the SDPF-U-MIX effective interaction show excellent agreement with the new data. Finally, a theoretical analysis of the spectrum of rotational states as a function of the pairing gap, together with cranked-shell-model calculations, provides intriguing evidence for a reduction in pairing correlations with increased angular momentum, also in line with the shell-model results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Population Genomic Analysis of 1,777 Extended-Spectrum Beta-Lactamase-Producing Klebsiella pneumoniae Isolates, Houston, Texas: Unexpected Abundance of Clonal Group 307

Klebsiella pneumoniae is a major human pathogen responsible for high morbidity and mortality rates. The emergence and spread of strains resistant to multiple antimicrobial agents and documented large nosocomial outbreaks are especially concerning. To develop new therapeutic strategies for K. pneumoniae, it is imperative to understand the population genomic structure of strains causing human infections. To address this knowledge gap, we sequenced the genomes of 1,777 extended-spectrum beta-lactamase-producing K. pneumoniae strains cultured from patients in the 2,000-bed Houston Methodist Hospital system between September 2011 and May 2015, representing a comprehensive, population-based strain sample. Strains of largely uncharacterized clonal group 307 (CG307) caused more infections than those of well-studied epidemic CG258. Strains varied markedly in gene content and had an extensive array of small and very large plasmids, often containing antimicrobial resistance genes. Some patients with multiple strains cultured over time were infected with genetically distinct clones. We identified 15 strains expressing the New Delhi metallo-beta-lactamase 1 (NDM-1) enzyme that confers broad resistance to nearly all beta-lactam antibiotics. Transcriptome sequencing analysis of 10 phylogenetically diverse strains showed that the global transcriptome of each strain was unique and highly variable. Experimental mouse infection provided new information about immunological parameters of host-pathogen interaction. We exploited the large data set to develop whole-genome sequence-based classifiers that accurately predict clinical antimicrobial resistance for 12 of the 16 antibiotics tested. We conclude that analysis of large, comprehensive, population-based strain samples can assist understanding of the molecular diversity of these organisms and contribute to enhanced translational research.

59 BASIC BIOLOGICAL SCIENCES↗

CHANDRA PHASE-RESOLVED X-RAY SPECTROSCOPY OF THE CRAB PULSAR

We present a new study of the X-ray spectral properties of the Crab Pulsar. The superb angular resolution of the Chandra X-Ray Observatory enables distinguishing the pulsar from the surrounding nebulosity. Analysis of the spectrum as a function of pulse phase allows the least-biased measure of interstellar X-ray extinction due primarily to photoelectric absorption and secondarily to scattering by dust grains in the direction of the Crab Nebula. We modify previous findings that the line of sight to the Crab is underabundant in oxygen and provide measurements with improved accuracy and less bias. Using the abundances and cross sections from Wilms et al. we find [O/H] = (5.28 {+-} 0.28) Multiplication-Sign 10{sup -4} (4.9 Multiplication-Sign 10{sup -4} is solar abundance). We also measure for the first time the impact of scattering of flux out of the image by interstellar grains. We find {tau}{sub scat} = 0.147 {+-} 0.043. Analysis of the spectrum as a function of pulse phase also measures the X-ray spectral index even at pulse minimum-albeit with increasing statistical uncertainty. The spectral variations are, by and large, consistent with a sinusoidal variation. The only significant variation from the sinusoid occurs over the same phase range as some rather abrupt behavior in the optical polarization magnitude and position angle. We also compare these spectral variations to those observed in gamma-rays and conclude that our measurements are both a challenge and a guide to future modeling and will thus eventually help us understand pair cascade processes in pulsar magnetospheres. The data are also used to set new, and less biased, upper limits to the surface temperature of the neutron star for different models of the neutron star atmosphere. We discuss how such data are best connected to theoretical models of neutron star cooling and neutron star interiors. The data restrict the neutrino emission rate in the pulsar core and the amount of light elements in the heat-blanketing envelope. The observations allow the pulsar, irrespective of the composition of its envelope, to have a neutrino emission rate higher than {approx}0.2 of the standard rate of a non-superfluid star cooling via the modified Urca process. The observations also allow the rate to be lower but now with a limited amount of accreted matter in the envelope.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements and analysis of bremsstrahlung x-ray spectrum obtained in NANOGAN electron cyclotron resonance ion source

From the ECR plasma, hot electrons leak across the magnetic lines of force and by striking the plasma chamber produce bremsstrahlung x-rays. The wall bremsstrahlung gives information on the confinement status of hot electron. In our studies, experimental measurements are carried out in NANOGAN electron cyclotron resonance (ECR) ion source for the wall bremsstrahlung x-rays and the results are presented. While optimizing a particular charge state in ECR ion source, experimental parameters are adjusted to get a maximum current. The wall bremsstrahlung components are studied in these cases for understanding the hot electron confinement conditions.

43 PARTICLE ACCELERATORS↗

Security Analysis of a Class of Spread Spectrum Systems Presentation

A method of adding physical layer security to a class of spread spectrum systems has been recently proposed. In this paper, we look into the rate at which an eavesdropper may gain information about the system to decipher the data symbols. The Shannon mutual information is used to measure the rate of information that may be gained by an eavesdropper. The k-nearest neighbors (k-NN) method is used to obtain estimates of relevant entropy values, which will then be used to quantify the rate of information recovery as more data is transmitted. It turns out that such information recovery requires the adoption of special methods that avoid any destructive bias in the estimates. Details of these methods are also presented.

97 - MATHEMATICS AND COMPUTING↗

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multivariate statistical analysis of atom probe tomography data

The application of spectrum imaging multivariate statistical analysis methods, specifically principal component analysis (PCA), to atom probe tomography (APT) data has been investigated. The mathematical method of analysis is described and the results for two example datasets are analyzed and presented. The first dataset is from the analysis of a PM 2000 Fe-Cr-Al-Ti steel containing two different ultrafine precipitate populations. PCA properly describes the matrix and precipitate phases in a simple and intuitive manner. A second APT example is from the analysis of an irradiated reactor pressure vessel steel. Fine, nm-scale Cu-enriched precipitates having a core-shell structure were identified and qualitatively described by PCA. Advantages, disadvantages, and future prospects for implementing these data analysis methodologies for APT datasets, particularly with regard to quantitative analysis, are also discussed.

36 MATERIALS SCIENCE↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable bandpass filter channel for signal spectrum analysis and signal discrimination is presented, including performance improvements to stability and precise matching between filter stages. The 8 th -order filter channel achieves an effective Q-factor of 4.5 and dynamic range of 60 dB, has an operational frequency range from 2 kHz to 100 kHz, and consumes 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology is selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2 nd -order filter cells and is fabricated in 130-nm 1.2-V CMOS technology, making it suitable for use in monolithic integrated spectral analysis (MISA) applications.

Long, Gavin↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications, while maintaining high dynamic range and a wide operational frequency range. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable analog filter channel for signal spectrum analysis and signal discrimination is presented. Project specifications required a programmable, high-order, monolithic bandpass filter channel with small chip area, low power consumption, high dynamic range, and wide operational frequency range. The 8th-order filter channel presented in this work provides an effective Q-factor of 4.5 and a minimum dynamic range (DR) of approximately 85 dB, while allowing for tuning across a range of center frequencies from 2 kHz to 100 kHz, with power consumption of a single 8th-order filter channel measured at 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology was selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2nd-order filter cells, resulting in a single 8th-order filter channel, fabricated in 130-nm 1.2-V CMOS technology, suitable for use in monolithic integrated spectral analysis (MISA1) applications.

Long, Gavin B.↗