Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

STAT7 v2.0 User Guide

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software includes non-power research and test reactor analysis, and it has been used for the conversion to low- enriched uranium fuel of U.S. High Performance Research Reactors such as the Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat reactor safety analysis, such as during fuel reloading, STAT7 accommodates flexibility in analyzing many practical aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for reactor thermal hydraulics analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to fitted functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze every axial node in each lateral stripe of all fuel plates and coolant channels in every fuel element of an entire reactor core. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. In a single execution, STAT7 can be used to perform full core analysis by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving Thermal Management Strategies for Data Centers: A Physical Testbed Incorporating Small Modular Reactor and Microreactor Technology

This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pyomo: Accidentally outrunning the bear

Pyomo is an open-source optimization modeling software that has undergone significant evolution since its inception in 2008. Pyomo has evolved to enhance flexibility, solver integration, and community engagement. Modern collaborative tools for open-source software have facilitated the development of new Pyomo functionality and improved our development process through automated testing and performance-tracking pipelines. However, Pyomo faces challenges typical of research software, including resource limitations and knowledge retention. The Pyomo team’s commitment to better development practices and community engagement reflects a proactive approach to these issues. We describe Pyomo’s development journey, highlighting both successes and failures, in the hopes that other open-source research software packages may benefit from our experiences.

automation↗

FEbeam: Cavity and electron emission data conversion, processing, and analysis. A freeware toolkit for rf injectors

FEbeam is an all-in-one field emission data processing interface with the capability to analyze the field emission cathode performance in an rf injector by extracting the field enhancement factor, local field, and effective emission area from the Fowler–Nordheim equations. It also has the capability of processing beam imaging micrographs using its sister software, FEpic. Furthermore, the current version of FEbeam was designed for the Argonne Cathode Test-stand of the Argonne Wakefield Accelerator facility switch yard. With slight modifications, FEbeam could work for many rf field emission injectors. This software is open-source and can be found at GitHub.

43 PARTICLE ACCELERATORS↗

Low Energy Muon Beam Diagnostics - Scintillating Fiber Profile Monitor (SFPM)

The MeV Test Area (MTA) houses the 400 MeV H^− Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Tabletop Testing for EV Charging Ecosystem PKI (Project T34PKI Final Report)

To test the communications and cybersecurity functionality, Electric Vehicle and charging station vendors have had to ship their products to in-person testing events. This is cumbersome, expensive, inefficient, and an impediment to rapid time-to-deployment. In this project Sandia used COTS hardware and Open-Source Software to develop and demonstrate a more agile, productive approach: testing low-voltage controllers independently from high-voltage power delivery sub-systems. This approach allows communications controllers to be transported easily (e.g. shipped at low cost, checked as airline baggage); set up on a table-top (“bench testing”); and use ordinary 120 VAC outlets to conduct agile testing. Table-top platforms become end nodes that can connect to laboratory and cloud-based servers to test communications and cybersecurity, specifically Public Key Infrastructure (PKI) functionality and interoperability, separately from EV battery charging (power/energy transfer) functionality.

33 ADVANCED PROPULSION SYSTEMS↗

Community-Driven Methods for Open and Reproducible Software Tools for Analyzing Datasets from Atom Probe Microscopy

Atom probe tomography, and related methods, probe the three-dimensional architecture of a material. The software tools that microscopists use, and how these tools are connected into workflows, makes a substantial contribution to the accuracy and precision of such a material characterization experiment. Typically, we adapt methods from other communities like mathematics, data science, computational geometry, artificial intelligence, or scientific computing. We also realize that improving on research data management is a challenge when it comes to align with the FAIR data stewardship principles. Faced with this global challenge, we are convinced that collaborating is useful. Here, we report the results and challenges with an inter-laboratory call for developing test cases for several types of atom probe software tools. The results support why defining detailed recipes of software workflows and sharing these recipes is necessary and rewarding: Open source tools and (meta)data exchange can help to make our day-to-day data processing tasks become more efficient, the training of new users and knowledge transfer become easier, and assist us with automated quantification of uncertainties to gain access to substantiated results.

36 MATERIALS SCIENCE↗

Validating automated resonance evaluation with synthetic data

The integrity and precision of nuclear data are crucial for a broad spectrum of applications, from national security and nuclear reactor design to medical diagnostics, where the associated uncertainties can significantly impact outcomes. A substantial portion of uncertainty in nuclear data originates from the subjective biases in the evaluation process, a crucial phase in the nuclear data production pipeline. Recent advancements indicate that automation of certain routines can mitigate these biases, thereby standardizing the evaluation process and enhancing reproducibility. This research aims to provide a methodology, framework, and metrics for the validation of automated nuclear data evaluation software leveraging high-quality synthetic data that closely mimic real experimental observables. An introduced error metric provides a scale and intuitive measure of the evaluation quality by quantifying the estimate’s accuracy and performance across the specified energy range. Synthetic data provides access to experimental observables and underlying resonance parameters, enabling comparison of different evaluations. The methodology is demonstrated using Ta-181 isotope data in the resolved resonance region. The Automated Resonance Identification Subroutine (ARIS), which operates without prior resonance information, was used to test and showcase the framework’s capabilities utilizing the proposed error metrics. The results demonstrate the effectiveness of the proposed approach and framework for optimizing software parameters and testing hypotheses through “what-if” controlled experiments, such as modifying assumptions about experimental conditions or average resonance parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Guideline 36 Conformance Test v2.0

ASHRAE Guideline 36 provides guidance for how typical commercial building HVAC systems should be controlled to reduce energy costs and improve the indoor environmental quality for occupants. An industry-led effort is developing test scripts for how control manufacturers can test that the control logic in their control products follows Guideline 36. This software intends to support that effort in two ways. First, by providing a testbed for control manufacturers to run the test scripts against their own control products and compare their generated results to the expected results provided by the test scripts. Second, by providing a testbed that can be used during the development of test scripts to rapidly and repeatably verify they exercise Guideline 36 logic as desired and generate accurate expected results that control products can be compared to. An initial version of the software has already been developed and released open-source by a previous CEC-funded project that implemented the first use case (https://github.com/LBNL-ETA/guideline36_conformance_test/blob/master/LICENSE.txt), while this software disclosure will add the functionality of the second use case, as well as update the software where needed, all open-source. We intend to extend and contribute to the existing open-source software repository.

Blum, David [Lawrence Berkeley National Laboratory↗

Exploratory Investigation of Disengagements and Crashes in Autonomous Vehicles Under Mixed Traffic: An Endogenous Switching Regime Framework

Autonomous Vehicles (AVs) have a large potential to improve traffic safety but also pose some critical challenges. While AVs may help reduce crashes caused by human error, they still may experience failures of technologies and sensing, as well as decision-making errors in a mixed traffic environment. A disengagement refers to an AV transitioning control from autonomous systems to the trained test driver. The safety critical nature of disengagements makes it imperative to analyze disengagements and crashes together. In this study, we analyze both crashes and disengagements from real-world AV driving in California to fill the knowledge gap regarding the relationship between disengagements and crashes in a mixed traffic environment. A nested logit model was calibrated using three different outcomes: (1) disengagement with a crash, (2) disengagement with no crash, and (3) no disengagement with a crash. Furthermore, endogenous switching regime models were also calibrated to draw distinctions between the relation of disengagements and crashes while accounting for endogeneity effects. The results show that factors related to AV systems (such as software failures) and other roadway participants increase the propensity of a disengagement without a crash. Furthermore, AVs were observed to disengage less often as the technology matured over time. Marginal effects revealed an 8% decrease. The results thus suggest that disengagements are a part of AVs' safe performance and disengagement alerts may need to be triggered in order to avoid certain failures with current technology.

42 ENGINEERING↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

FAST-1.2 User Installation and Verification Guide: Developed Under NQA-1-2017

The purpose of this document is to provide the user information about the installation of Fuel Analysis for Steady state and Transient (FAST)-1.2 on their computers or servers. General information about the code and supported operating systems is described in Section 1.0. Self-service oriented FAST-1.2 software licensing steps are described in Section 2.0. An installation verification test suite is provided with FAST-1.2 and described in Section 3.0. A convenience script for converting Fuel Rod Analysis Program – Constant (FRAPCON) to FAST inputs is discussed in Section 4.0. FAST-1.2 was developed and released under a software quality assurance program based upon NQA-1-2017 at Pacific Northwest National Laboratory (PNNL). FAST-1.2 is the latest baseline code. The installation verification test suite contains both steady state and transient Anticipated Operation Occurrences (AOOs), accident conditions, such as Reactivity Initiated Accidents (RIAs) and Loss of Coolant Accidents (LOCAs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Generalized framework for likelihood-based field-level inference of growth rate from velocity and density fields

Measuring the growth rate of large-scale structures ( f ) as a function of redshift has the potential to break degeneracies between modified gravity and dark energy models, when combined with expansion-rate probes. Direct estimates of peculiar velocities of galaxies have attracted interest as a means of estimating fσ 8 . In particular, field-level methods can be used to fit the field nuisance parameter along with cosmological parameters simultaneously. This article aims to provide the community with a unified framework for the theoretical modeling of the likelihood-based field-level inference by performing fast field covariance calculations for velocity and density fields. Our purpose is to lay the foundations for a nonlinear extension of the likelihood-based method at the field level. We have developed a generalized framework, implemented in the dedicated software flip to perform a likelihood-based inference of fσ 8 . We derived a new field covariance model, which includes wide-angle corrections. We also included the models previously described in the literature inside our framework. We compared their performance against ours, and we validated our model by comparing it with the two-point statistics of a recent N-body simulation. The tests we performed have allowed us to validate our software and determine the appropriate wavenumber range to integrate our covariance model and its validity in terms of separation. Our framework allows for a wider wavenumber coverage to be used in our calculations than in previous works, which is particularly interesting for nonlinear model extensions. Finally, our generalized framework allows us to efficiently perform a survey geometry-dependent Fisher forecast of the fσ 8 parameter. We show that the Fisher forecast method we developed gives an error bar that is 30% closer to a full likelihood-based estimation than a standard volume Fisher forecast.

Ravoux, Corentin↗

Machine learning accelerated discrete element modeling of granular flows

Granular flows are widely encountered in many industrial processes and natural phenomena. Discrete Element Modeling (DEM) is a useful tool for understanding and troubleshooting devices, which handle granular materials. However, its applicability is significantly limited by the huge computational cost associated with detecting and computing collisions. In this research, the computation speed of DEM was accelerated by orders of magnitude using a convolutional neural network to replace the direct calculation of particle-particle and particle-boundary collisions. The MFiX software was used to generate the training and testing dataset. Additionally, a GPU accelerated TensorFlow model was used to train the neural network and test the results. The model fluctuations caused by different training steps were reduced with a multi-scale loss function. The accuracy was improved with more frames within one training step. The modeling of a rotating drum and a hopper demonstrated the accuracy and efficiency of this machine learning accelerated DEM in the simulation of granular flows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗