Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sleeves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Analysis of International Space Station Vehicle Materials on MISSE 6

The International Space Station Materials and Processes team has multiple material samples on MISSE 6, 7 and 8 to observe Low Earth Orbit (LEO) environmental effects on Space Station materials. Optical properties, thickness/mass loss, surface elemental analysis, visual and microscopic analysis for surface change are some of the techniques employed in this investigation. Results for the following MISSE 6 samples materials will be presented: deionized water sealed anodized aluminum; Hyzod(tm) polycarbonate used to temporarily protect ISS windows; Russian quartz window material; Beta Cloth with Teflon(tm) reformulated without perfluorooctanoic acid (PFOA), and electroless nickel. Discussion for current and future MISSE materials experiments will be presented. MISSE 7 samples are: more deionized water sealed anodized aluminum, including Photofoil(tm); indium tin oxide (ITO) over-coated Kapton(tm) used as thermo-optical surfaces; mechanically scribed tin-plated beryllium-copper samples for "tin pest" growth (alpha/beta transformation); and beta cloth backed with a black coating rather than aluminization. MISSE 8 samples are: exposed "scrim cloth" (fiberglass weave) from the ISS solar array wing material, protective fiberglass tapes and sleeve materials, and optical witness samples to monitor contamination.

Finckenor, Miria↗

GeoLab in NASA's Pressurized Excursion Module: First Results from the 2010 Field Trials

Before humans explore other planets, NASA must develop advanced techniques for collection, preservation and return of unique extraterrestrial samples. To help evaluate hardware requirements and operational concepts for future sample-return missions, we designed and built GeoLab our first generation lab for geological samples into NASA s Habitat Demonstration Unit in the Pressurized Excursion Module (HDU1-PEM). The center of GeoLab is a glovebox for the examination of samples in a shirt-sleeve environment. As part of a deployable habitat, GeoLab can participate in NASA s analog missions that simulate planetary exploration activities and support the testing of relevant technologies for collecting and handling geological samples. Over time, these tests will evaluate sample handling environments (field and lab), sampling tools and analytical instruments, and different scenarios involving both robotic and human procedures. The GeoLab design supports evolving tests and configurations. The glovebox is mounted on the habitat bulkhead, with three sample pass-though chambers that allow for direct sample transfer into the glovebox from the outside. The glovebox design and construction (low-particle shedding, minimally off-gassing materials) provides a clean environment to reduce sample contamination; in the future, we will integrate a positive pressure, enriched nitrogen atmosphere. The glovebox is equipped with configurable instrument ports. The 2010 test included a mass balance, a stereomicroscope with a HD camera for detailed imaging of samples, and a handheld XRF analyzer for preliminary geochemical characterization of samples. Network cameras provided context imagery and sample handling activities. We present early results from the initial field trial of GeoLab during the 2010 Desert Research and Technology Studies (D-RATS) planetary analog test near Flagstaff AZ. The 2010 D-RATS mission involved two rovers, the habitat with GeoLab, four crew members, and a team of scientists and flight controllers. The crewed rovers conducted geological traverses and collected samples on the planetary surface. Selected samples were transferred into GeoLab for detailed examination and initial analysis, providing critical data to the science team for evaluation and prioritization of samples.

Evans, Cynthia A.↗

Selecting Tasks for Evaluating Human Performance as a Function of Gravity

A challenge in understanding human performance as a function of gravity is determining which tasks to research. Initial studies began with treadmill walking, which was easy to quantify and control. However, with the development of pressurized rovers, it is less important to optimize human performance for ambulation as rovers will likely perform gross translation for them. Future crews are likely to spend much of their extravehicular activity (EVA) performing geology, construction and maintenance type tasks, for which it is difficult to measure steady-state-workloads. To evaluate human performance in reduced gravity, we have collected metabolic, biomechanical and subjective data for different tasks at varied gravity levels. Methods: Ten subjects completed 5 different tasks including weight transfer, shoveling, treadmill walking, treadmill running and treadmill incline walking. All tasks were performed shirt-sleeved at 1-g, 3/8-g and 1/6-g. Off-loaded conditions were achieved via the Active Response Gravity Offload System. Treadmill tasks were performed for 3 minutes with reported oxygen consumption (VO2) averaged over the last 2 minutes. Shoveling was performed for 3 minutes with metabolic cost reported as ml O2 consumed per kg material shoveled. Weight transfer reports metabolic cost as liters O2 consumed to complete the task. Statistical analysis was performed via repeated measures ANOVA. Results: Statistically significant metabolic differences were noted between all 3 gravity levels for treadmill running and incline walking. For the other 3 tasks, there were significant differences between 1-g and each reduced gravity, but not between 1/6-g and 3/8-g. For weight transfer, significant differences were seen between gravities in both trial-average VO2 and time-to-completion with noted differences in strategy for task completion. Conclusion: To determine if gravity has a metabolic effect on human performance, this research may indicate that tasks should be selected that require the subject to work vertically against the force of gravity.

Norcross, J. R.↗

Method and apparatus for shape and end position determination using an optical fiber

A method of determining the shape of an unbound optical fiber includes collecting strain data along a length of the fiber, calculating curvature and bending direction data of the fiber using the strain data, curve-fitting the curvature and bending direction data to derive curvature and bending direction functions, calculating a torsion function using the bending direction function, and determining the 3D shape from the curvature, bending direction, and torsion functions. An apparatus for determining the 3D shape of the fiber includes a fiber optic cable unbound with respect to a protective sleeve, strain sensors positioned along the cable, and a controller in communication with the sensors. The controller has an algorithm for determining a 3D shape and end position of the fiber by calculating a set of curvature and bending direction data, deriving curvature, bending, and torsion functions, and solving Frenet-Serret equations using these functions.

Moore, Jason P.↗

Hybrid Composite Cryogenic Tank Structure

A hybrid lightweight composite tank has been created using specially designed materials and manufacturing processes. The tank is produced by using a hybrid structure consisting of at least two reinforced composite material systems. The inner composite layer comprises a distinct fiber and resin matrix suitable for cryogenic use that is a braided-sleeve (and/or a filamentwound layer) aramid fiber preform that is placed on a removable mandrel (outfitted with metallic end fittings) and is infused (vacuum-assisted resin transfer molded) with a polyurethane resin matrix with a high ductility at low temperatures. This inner layer is allowed to cure and is encapsulated with a filamentwound outer composite layer of a distinct fiber resin system. Both inner and outer layer are in intimate contact, and can also be cured at the same time. The outer layer is a material that performs well for low temperature pressure vessels, and it can rely on the inner layer to act as a liner to contain the fluids. The outer layer can be a variety of materials, but the best embodiment may be the use of a continuous tow of carbon fiber (T-1000 carbon, or others), or other high-strength fibers combined with a high ductility epoxy resin matrix, or a polyurethane matrix, which performs well at low temperatures. After curing, the mandrel can be removed from the outer layer. While the hybrid structure is not limited to two particular materials, a preferred version of the tank has been demonstrated on an actual test tank article cycled at high pressures with liquid nitrogen and liquid hydrogen, and the best version is an inner layer of PBO (poly-pphenylenebenzobisoxazole) fibers with a polyurethane matrix and an outer layer of T-1000 carbon with a high elongation epoxy matrix suitable for cryogenic temperatures. A polyurethane matrix has also been used for the outer layer. The construction method is ideal because the fiber and resin of the inner layer has a high strain to failure at cryogenic temperatures, and will not crack or produce leaks. The outer layer serves as more of a high-performance structural unit for the inner layer, and can handle external environments.

DeLay, Thomas↗

Generating Control Commands From Gestures Sensed by EMG

An effort is under way to develop noninvasive neuro-electric interfaces through which human operators could control systems as diverse as simple mechanical devices, computers, aircraft, and even spacecraft. The basic idea is to use electrodes on the surface of the skin to acquire electromyographic (EMG) signals associated with gestures, digitize and process the EMG signals to recognize the gestures, and generate digital commands to perform the actions signified by the gestures. In an experimental prototype of such an interface, the EMG signals associated with hand gestures are acquired by use of several pairs of electrodes mounted in sleeves on a subject s forearm (see figure). The EMG signals are sampled and digitized. The resulting time-series data are fed as input to pattern-recognition software that has been trained to distinguish gestures from a given gesture set. The software implements, among other things, hidden Markov models, which are used to recognize the gestures as they are being performed in real time. Thus far, two experiments have been performed on the prototype interface to demonstrate feasibility: an experiment in synthesizing the output of a joystick and an experiment in synthesizing the output of a computer or typewriter keyboard. In the joystick experiment, the EMG signals were processed into joystick commands for a realistic flight simulator for an airplane. The acting pilot reached out into the air, grabbed an imaginary joystick, and pretended to manipulate the joystick to achieve left and right banks and up and down pitches of the simulated airplane. In the keyboard experiment, the subject pretended to type on a numerical keypad, and the EMG signals were processed into keystrokes. The results of the experiments demonstrate the basic feasibility of this method while indicating the need for further research to reduce the incidence of errors (including confusion among gestures). Topics that must be addressed include the numbers and arrangements of electrodes needed to acquire sufficient data; refinements in the acquisition, filtering, and digitization of EMG signals; and methods of training the pattern- recognition software. The joystick and keyboard simulations were chosen for the initial experiments because they are familiar to many computer users. It is anticipated that, ultimately, interfaces would utilize EMG signals associated with movements more nearly natural than those associated with joysticks or keyboards. Future versions of the pattern-recognition software are planned to be capable of adapting to the preferences and day-today variations in EMG outputs of individual users; this capability for adaptation would also make it possible to select gestures that, to a given user, feel the most nearly natural for generating control signals for a given task (provided that there are enough properly positioned electrodes to acquire the EMG signals from the muscles involved in the gestures).

Wheeler, Kevin R.↗

Modifications of a Composite-Material Combustion Chamber

Two short reports discuss modifications of a small, lightweight combustion chamber that comprises a carbon/carbon composite outer shell and an iridium/ rhenium inner liner. The first report discusses chamber design modifications made as results of hot-fire tests and post-test characterization. The Books & Reports 32 NASA Tech Briefs, June 2005 modifications were intended to serve a variety of purposes, including improving fabrication, reducing thermal-expansion mismatch stresses, increasing strength-to-weight ratios of some components, and improving cooling of some components. The second report discusses (1) the origin of stress in the mismatch between the thermal expansions of the Ir/Re liner and a niobium sleeve and flange attached to the carbon/ carbon shell and (2) a modification intended to relieve the stress. The modification involves the redesign of an inlet connection to incorporate a compressible seal between the Ir/Re liner and the Nb flange. A nickel alloy was selected as the seal material on the basis of its thermal-expansion properties and its ability to withstand the anticipated stresses, including the greatest stresses caused by the high temperatures to be used in brazing during fabrication.

Williams, Brian E.↗

Deployable Wide-Aperture Array Antennas

Inexpensive, lightweight array antennas on flexible substrates are under development to satisfy a need for large-aperture antennas that can be stored compactly during transport and deployed to full size in the field. Conceived for use aboard spacecraft, antennas of this type also have potential terrestrial uses . most likely, as means to extend the ranges of cellular telephones in rural settings. Several simple deployment mechanisms are envisioned. One example is shown in the figure, where the deployment mechanism, a springlike material contained in a sleeve around the perimeter of a flexible membrane, is based on a common automobile window shade. The array can be formed of antenna elements that are printed on small sections of semi-flexible laminates, or preferably, elements that are constructed of conducting fabric. Likewise, a distribution network connecting the elements can be created from conventional technologies such as lightweight, flexible coaxial cable and a surface mount power divider, or preferably, from elements formed from conductive fabrics. Conventional technologies may be stitched onto a supporting flexible membrane or contained within pockets that are stitched onto a flexible membrane. Components created from conductive fabrics may be attached by stitching conductive strips to a nonconductive membrane, embroidering conductive threads into a nonconductive membrane, or weaving predetermined patterns directly into the membrane. The deployable antenna may comprise multiple types of antenna elements. For example, thin profile antenna elements above a ground plane, both attached to the supporting flexible membrane, can be used to create a unidirectional boresight radiation pattern. Or, antenna elements without a ground plane, such as bow-tie dipoles, can be attached to the membrane to create a bidirectional array such as that shown in the figure. For either type of antenna element, the dual configuration, i.e., elements formed of slots in a conductive membrane, can also be used. Finally, wide bandwidth antennas or arrays can be formed in which the principal direction of radiation is in the plane of the membrane. For this embodiment, the set of elements on the membrane is arranged to form one or more traveling wave antennas. In this case, a nonconductive form of the perimeter springlike material is required to provide the deploying force.

Fink, Patrick W.↗

NASA Tech Briefs, February 2003

opics covered include: Integrated Electrode Arrays for Neuro-Prosthetic Implants; Eroding Potentiometers; Common/Dependent-Pressure-Vessel Nickel-Hydrogen Batteries; 120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna; 80-GHz MMIC HEMT Voltage-Controlled Oscillator; High-Energy-Density Capacitors; Microscale Thermal-Transpiration Gas Pump; Instrument for Measuring Temperature of Water; Improved Measurement of Coherence in Presence of Instrument Noise; Compact Instruments Measure Helium-Leak Rates; Irreversible Entropy Production in Two-Phase Mixing Layers; Subsonic and Supersonic Effects in Bose-Einstein Condensate; Nanolaminate Mirrors With "Piston" Figure-Control Actuators; Mixed Conducting Electrodes for Better AMTEC Cells; Process for Encapsulating Protein Crystals; Lightweight, Self-Deployable Wheels; Grease-Resistant O Rings for Joints in Solid Rocket Motors; LabVIEW Serial Driver Software for an Electronic Load; Software Computes Tape-Casting Parameters; Software for Tracking Costs of Mars Projects; Software for Replicating Data Between X.500 and LDAP Directories; The Technical Work Plan Tracking Tool; Improved Multiple-DOF SAW Piezoelectric Motors; Propulsion Flight-Test Fixture; Mechanical Amplifier for a Piezoelectric Transducer; Swell Sleeves for Testing Explosive Devices; Linear Back-Drive Differentials; Miniature Inchworm Actuators Fabricated by Use of LIGA; Using ERF Devices to Control Deployments of Space Structures; High-Temperature Switched-Reluctance Electric Motor; System for Centering a Turbofan in a Nacelle During Tests; Fabricating Composite-Material Structures Containing SMA Ribbons; Optimal Feedback Control of Thermal Networks; Artifacts for Calibration of Submicron Width Measurements; Navigating a Mobile Robot Across Terrain Using Fuzzy Logic; Designing Facilities for Collaborative Operations; and Quantitating Iron in Serum Ferritin by Use of ICP-MS.

Source record↗

Fabricating Composite-Material Structures Containing SMA Ribbons

An improved method of designing and fabricating laminated composite-material (matrix/fiber) structures containing embedded shape-memory-alloy (SMA) actuators has been devised. Structures made by this method have repeatable, predictable properties, and fabrication processes can readily be automated. Such structures, denoted as shape-memory-alloy hybrid composite (SMAHC) structures, have been investigated for their potential to satisfy requirements to control the shapes or thermoelastic responses of themselves or of other structures into which they might be incorporated, or to control noise and vibrations. Much of the prior work on SMAHC structures has involved the use SMA wires embedded within matrices or within sleeves through parent structures. The disadvantages of using SMA wires as the embedded actuators include (1) complexity of fabrication procedures because of the relatively large numbers of actuators usually needed; (2) sensitivity to actuator/ matrix interface flaws because voids can be of significant size, relative to wires; (3) relatively high rates of breakage of actuators during curing of matrix materials because of sensitivity to stress concentrations at mechanical restraints; and (4) difficulty of achieving desirable overall volume fractions of SMA wires when trying to optimize the integration of the wires by placing them in selected layers only.

Turner, Travis L.↗

A Comparison Between Jerusalem Cross and Square Patch Frequency Selective Surfaces for Low Profile Antenna Applications

In this paper, a comparison between Jerusalem Cross (JC) and Square Patch (SP) based Frequency Selected Surfaces (FSS) for low profile antenna applications is presented. The comparison is aimed at understanding the performance of low profile antennas backed by high impedance surfaces. In particular, an end loaded planar open sleeve dipole (ELPOSD) antenna is examined due to the various parameters within its configuration, offering significant design flexibility and a wide operating bandwidth. Measured data of the antennas demonstrate that increasing the number of unit cells improves the fractional bandwidth. The antenna bandwidth increased from 0.8% to 1.8% and from 0.8% to 2.7% for the JC and SP structures, respectively. The number of unit cells was increased from 48 to 80 for the JC-FSS and from 24 to 48 for the SP-FSS.

Cure, David↗

Low Cost Space Demonstration for a Single-Person Spacecraft

This paper introduces a concept for a single-person spacecraft and presents plans for flying a low-cost, robotic demonstration mission. Called FlexCraft, the vehicle integrates propulsion and robotics into a small spacecraft that enables rapid, shirt-sleeve access to space. It can be flown by astronauts or tele-operated and is equipped with interchangeable manipulators used for maintaining the International Space Station (ISS), exploring asteroids, and servicing telescopes or satellites. Most FlexCraft systems are verified using ground facilities; however, a test in the weightless environment is needed to assess propulsion and manipulator performance. For this, a simplified, unmanned, version of FlexCraft is flown on a low-cost launch vehicle to a 350 km circular orbit. After separation from the upper stage, the vehicle returns to a target box mounted on the stage testing the propulsion and control capability. The box is equipped with manipulator test items that are representative of tasks performed on ISS, asteroid missions, or for satellites servicing. Nominal and off-nominal operations are conducted over 3 days then the vehicle re-enters the atmosphere without becoming a debris hazard. From concept to management to operations, the FlexCraft demonstration is designed to be low cost project that is launched within three years. This is possible using a simplified test configuration that eliminates nine systems unique to the operational version and by designing-to-availability. For example, the propulsion system is the same as the Manned Maneuvering Unit because it capable, simple, human-rated and all components or equivalent parts are available. A description of the launch vehicle options, mission operations, configuration, and demonstrator subsystems is presented.

Griffin, Brand N.↗

Post STS-134 Evaluation of Main Flame Deflector Witness Materials

NASA and USA design engineers submitted witness materials from the solid rocket booster (SRB) main flame deflector for evaluation after the launch of STS-134. The following items were submitted for analysis: 1018 steel witness rods 304 stainless steel caps, tungsten pistons, and A-286 piston sleeves. All of the items were photographed in order to document their condition after the launch of STS-134. All of the items were dimensionally measured in order to determine the amount of material lost during launch. Microstructural changes were observed in the 1018 witness rod metallographic samples due to the heat of the launch

Long, Victoria↗

Sample Sealing Approaches for Mars Sample Return Caching

Objective ot this project was to investigate sealing methods for encapsulating samples in 1 cm diameter thin-walled sample tubes applicable to future proposed Mars Sample Return Techniques implemented include a spring energized Teflon sleeve plug, a crimped tube seal, a heat-activated shape memory alloy plug, a shape memory alloy activated cap, a solder-based plug, and a solder-based cap

Mars Sample Return (MSR) mission↗

NASA Tech Briefs, March 2014

Topics include: Data Fusion for Global Estimation of Forest Characteristics From Sparse Lidar Data; Debris and Ice Mapping Analysis Tool - Database; Data Acquisition and Processing Software - DAPS; Metal-Assisted Fabrication of Biodegradable Porous Silicon Nanostructures; Post-Growth, In Situ Adhesion of Carbon Nanotubes to a Substrate for Robust CNT Cathodes; Integrated PEMFC Flow Field Design for Gravity-Independent Passive Water Removal; Thermal Mechanical Preparation of Glass Spheres; Mechanistic-Based Multiaxial-Stochastic-Strength Model for Transversely-Isotropic Brittle Materials; Methods for Mitigating Space Radiation Effects, Fault Detection and Correction, and Processing Sensor Data; Compact Ka-Band Antenna Feed with Double Circularly Polarized Capability; Dual-Leadframe Transient Liquid Phase Bonded Power Semiconductor Module Assembly and Bonding Process; Quad First Stage Processor: A Four-Channel Digitizer and Digital Beam-Forming Processor; Protective Sleeve for a Pyrotechnic Reefing Line Cutter; Metabolic Heat Regenerated Temperature Swing Adsorption; CubeSat Deployable Log Periodic Dipole Array; Re-entry Vehicle Shape for Enhanced Performance; NanoRacks-Scale MEMS Gas Chromatograph System; Variable Camber Aerodynamic Control Surfaces and Active Wing Shaping Control; Spacecraft Line-of-Sight Stabilization Using LWIR Earth Signature; Technique for Finding Retro-Reflectors in Flash LIDAR Imagery; Novel Hemispherical Dynamic Camera for EVAs; 360 deg Visual Detection and Object Tracking on an Autonomous Surface Vehicle; Simulation of Charge Carrier Mobility in Conducting Polymers; Observational Data Formatter Using CMOR for CMIP5; Propellant Loading Physics Model for Fault Detection Isolation and Recovery; Probabilistic Guidance for Swarms of Autonomous Agents; Reducing Drift in Stereo Visual Odometry; Future Air-Traffic Management Concepts Evaluation Tool; Examination and A Priori Analysis of a Direct Numerical Simulation Database for High-Pressure Turbulent Flows; and Resource-Constrained Application of Support Vector Machines to Imagery.

Source record↗

Acquisition and Retaining Granular Samples via a Rotating Coring Bit

This device takes advantage of the centrifugal forces that are generated when a coring bit is rotated, and a granular sample is entered into the bit while it is spinning, making it adhere to the internal wall of the bit, where it compacts itself into the wall of the bit. The bit can be specially designed to increase the effectiveness of regolith capturing while turning and penetrating the subsurface. The bit teeth can be oriented such that they direct the regolith toward the bit axis during the rotation of the bit. The bit can be designed with an internal flute that directs the regolith upward inside the bit. The use of both the teeth and flute can be implemented in the same bit. The bit can also be designed with an internal spiral into which the various particles wedge. In another implementation, the bit can be designed to collect regolith primarily from a specific depth. For that implementation, the bit can be designed such that when turning one way, the teeth guide the regolith outward of the bit and when turning in the opposite direction, the teeth will guide the regolith inward into the bit internal section. This mechanism can be implemented with or without an internal flute. The device is based on the use of a spinning coring bit (hollow interior) as a means of retaining granular sample, and the acquisition is done by inserting the bit into the subsurface of a regolith, soil, or powder. To demonstrate the concept, a commercial drill and a coring bit were used. The bit was turned and inserted into the soil that was contained in a bucket. While spinning the bit (at speeds of 600 to 700 RPM), the drill was lifted and the soil was retained inside the bit. To prove this point, the drill was turned horizontally, and the acquired soil was still inside the bit. The basic theory behind the process of retaining unconsolidated mass that can be acquired by the centrifugal forces of the bit is determined by noting that in order to stay inside the interior of the bit, the frictional force must be greater than the weight of the sample. The bit can be designed with an internal sleeve to serve as a container for granular samples. This tube-shaped component can be extracted upon completion of the sampling, and the bottom can be capped by placing the bit onto a corklike component. Then, upon removal of the internal tube, the top section can be sealed. The novel features of this device are: center dot A mechanism of acquiring and retaining granular samples using a coring bit without a closed door. center dot An acquisition bit that has internal structure such as a waffle pattern for compartmentalizing or helical internal flute to propel the sample inside the bit and help in acquiring and retaining granular samples. center dot A bit with an internal spiral into which the various particles wedge. center dot A design that provides a method of testing frictional properties of the granular samples and potentially segregating particles based on size and density. A controlled acceleration or deceleration may be used to drop the least-frictional particles or to eventually shear the unconsolidated material near the bit center.

Bar-Cohen, Yoseph↗

Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e.g., 44 percent increase as relative humidity changed from 18 percent and dew point 33 degF to 50 percent and dew point of 57 degF.

Ashpis, David E.↗

Human Performance in Simulated Reduced Gravity Environments

NASA is currently designing a new space suit capable of working in deep space and on Mars. Designing a suit is very difficult and often requires trade‐offs between performance, cost, mass, and system complexity. Our current understanding of human performance in reduced gravity in a planetary environment (the moon or Mars) is limited to lunar observations, studies from the Apollo program, and recent suit tests conducted at JSC using reduced gravity simulators. This study will look at our most recent reduced gravity simulations performed on the new Active Response Gravity Offload System (ARGOS) compared to the C‐9 reduced gravity plane. Methods: Subjects ambulated in reduced gravity analogs to obtain a baseline for human performance. Subjects were tested in lunar gravity (1.6 m/sq s) and Earth gravity (9.8 m/sq s) in shirt‐sleeves. Subjects ambulated over ground at prescribed speeds on the ARGOS, but ambulated at a self‐selected speed on the C‐9 due to time limitations. Subjects on the ARGOS were given over 3 minutes to acclimate to the different conditions before data was collected. Nine healthy subjects were tested in the ARGOS (6 males, 3 females, 79.5 +/- 15.7 kg), while six subjects were tested on the C‐9 (6 males, 78.8 +/- 11.2 kg). Data was collected with an optical motion capture system (Vicon, Oxford, UK) and was analyzed using customized analysis scripts in BodyBuilder (Vicon, Oxford, UK) and MATLAB (MathWorks, Natick, MA, USA). Results: In all offloaded conditions, variation between subjects increased compared to 1‐g. Kinematics in the ARGOS at lunar gravity resembled earth gravity ambulation more closely than the C‐9 ambulation. Toe‐off occurred 10% earlier in both reduced gravity environments compared to earth gravity, shortening the stance phase. Likewise, ankle, knee, and hip angles remained consistently flexed and had reduced peaks compared to earth gravity. Ground reaction forces in lunar gravity (normalized to Earth body weight) were 0.4 +/- 0.2 on the ARGOS, but only 0.2 +/- 0.1 on the C‐9. Discussion: Gait analysis showed differences in joint kinematics and temporal‐spatial parameters between the reduced gravity simulators and with respect to earth gravity. Although most of the subjects chose a somewhat unique ambulation style as a result of learning to ambulate in a new environment, all but two were consistent with keeping an Earth‐like gait. Learning how reduced gravity affects ambulation will help NASA to determine optimal suit designs, influence mission planning, help train crew, and may shed light on the underlying methods the body uses to optimize gait for energetic efficiency. Conclusion: Kinematic and kinetic analysis demonstrated noteworthy differences between an offloaded environment and 1‐g, as would be expected. The analysis showed a trend to change the ambulation style in an offloaded environment to a rolling‐loping walk (resembling crosscountry skiing) with increased swing time. This ambulation modification, particularly in the ARGOS, indicated that the relative kinetic energy of the subject was increased, on average, per the static body weight compared to the 1‐g condition. How much of this was influenced by the active offloading of the ARGOS system is unknown.

Cowley, Matthew↗