Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis

State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 {mu}m in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program 'SARINA,' which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic Pairs: A DESI Census of Dual and Offset AGN as Precursors to Massive Black Hole Binaries

We present a systematic census of dual and offset active galactic nuclei (AGN) using spectroscopic data from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). After correcting for observational systematics, our final sample contains $>7,000$ dual AGN and 27,000 galaxy pairs containing one AGN over the redshift range $0 \lesssim z \lesssim 3.6$. This sample expands the known dual AGN sample by $\sim 1-2$ orders of magnitude at $0.2 \lesssim z \lesssim 0.4$, includes $\sim 50$ dwarf dual AGN candidates in a regime where only a handful were previously known, and triples the census at $z>2$. Dual AGN are preferentially found at small separations, consistent with merger-driven triggering of AGN activity. The two members of a pair differ in their star formation response: the more massive (primary) host changes little with separation, while the less massive (secondary) lies $\sim 0.3$ dex above matched inactive and one-AGN companions at the same projected separation in main-sequence offset. Using ASTRID simulations, we predict that the fraction of DESI dual AGN whose central black holes will merge by $z \sim 0$ increases with redshift, reaching $\sim 76\%$ by $z \sim 2$, while the fraction producing LISA-detectable mergers peaks at $\sim 37\%$ near $z \sim 0.9$. These results provide the largest uniformly selected spectroscopic sample of kpc-scale dual and offset AGN candidates from a single survey, connecting their host-galaxy and AGN demographics to the progenitor population of massive black hole mergers detectable by LISA.

Dadiani, Ekaterine [Carnegie Mellon U.] (ORCID:000↗

Secondary Ion Mass Spectrometry of Environmental Aerosols

Atmospheric particles influence many aspects of climate, air quality and human health. Understanding the composition, chemistry and behavior of atmospheric aerosols is a key remaining challenge in improving climate models. Furthermore, particles may be traced back to a particular source based on composition, stable isotope ratios, or the presence of particular surface chemistries. Finally, the characterization of atmospheric particles in the workplace plays an important role in understanding the potential for exposure and environmental and human health effects to engineered and natural nanoscale particles. Secondary ion mass spectrometry (SIMS) is a useful tool in determining any of several aspects of the structure, composition and chemistry of these particles. Often used in conjunction with other surface analysis and electron microscopy methods, SIMS has been used to determine or confirm reactions on and in particles, the presence of particular organic species on the surface of atmospheric aerosols and several other interesting and relevant findings. Various versions of SIMS instruments – dynamic SIMS, time of flight secondary ion mass spectrometry or TOF-SIMS, nanoSIMS – have been used to determine specific aspects of aerosol structure and chemistry. This article describes the strengths of each type of SIMS instrument in the characterization of aerosols, along with guidance on sample preparation, specific characterization specific to the particular information sought in the analysis. Examples and guidance are given for each type of SIMS analysis.

54 ENVIRONMENTAL SCIENCES↗

Search for top squarks in the four-body decay mode with single lepton final states in proton-proton collisions at $ \sqrt{s} $ = 13 TeV

A search for the pair production of the lightest supersymmetric partner of the top quark, the top squark ($ {\overset{\sim }{\textrm{t}}}_1 $), is presented. The search targets the four-body decay of the $ {\overset{\sim }{\textrm{t}}}_1 $, which is preferred when the mass difference between the top squark and the lightest supersymmetric particle is smaller than the mass of the W boson. This decay mode consists of a bottom quark, two other fermions, and the lightest neutralino ($ {\overset{\sim }{\chi}}_1^0 $), which is assumed to be the lightest supersymmetric particle. The data correspond to an integrated luminosity of 138 fb$^{−1}$ of proton-proton collisions at a center-of-mass energy of 13 TeV collected by the CMS experiment at the CERN LHC. Events are selected using the presence of a high-momentum jet, an electron or muon with low transverse momentum, and a significant missing transverse momentum. The signal is selected based on a multivariate approach that is optimized for the difference between m($ {\overset{\sim }{\textrm{t}}}_1 $) and m($ {\overset{\sim }{\chi}}_1^0 $). The contribution from leading background processes is estimated from data. No significant excess is observed above the expectation from standard model processes. The results of this search exclude top squarks at 95% confidence level for masses up to 480 and 700 GeV for m($ {\overset{\sim }{\textrm{t}}}_1 $) − m($ {\overset{\sim }{\chi}}_1^0 $) = 10 and 80 GeV, respectively.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric comparison of two arc-based stereotactic body radiotherapy techniques for early-stage lung cancer

To compare the dosimetric and delivery characteristics of two arc-based stereotactic body radiotherapy (SBRT) techniques for early-stage lung cancer treatment. SBRT treatment plans for lung tumors of different sizes and locations were designed using a single-isocenter multisegment dynamic conformal arc technique (SiMs-arc) and a volumetric modulated arc therapy technique (RapidArc) for 5 representative patients treated previously with lung SBRT. The SiMs-arc plans were generated with the isocenter located in the geometric center of patient's axial plane (which allows for collision-free gantry rotation around the patient) and 6 contiguous 60° arc segments spanning from 1° to 359°. 2 RapidArc plans, one using the same arc geometry as the SiMs-arc and the other using typical partial arcs (210°) with the isocenter inside planning target volume (PTV), were generated for each corresponding SiMs-arc plan. All plans were generated using the Varian Eclipse treatment planning system (V10.0) and were normalized with PTV V{sub 100} to 95%. PTV coverage, dose to organs at risk, and total monitor units (MUs) were then compared and analyzed. For PTV coverage, the RapidArc plans generally produced higher PTV D{sub 99} (by 1.0% to 3.3%) and higher minimum dose (by 2.7% to 12.7%), better PTV conformality index (by 1% to 8%), and less volume of 50% dose outside 2 cm from PTV (by 0 to 20.8 cm{sup 3}) than the corresponding SiMs-arc plans. For normal tissues, no significant dose differences were observed for the lungs, trachea, chest wall, and heart; RapidArc using partial arcs produced lowest maximum dose to spinal cord. For dose delivery, the RapidArc plans typically required 50% to 90% more MUs than SiMs-arc plans to deliver the same prescribed dose. The additional intensity modulation afforded by variable gantry speed and dose rate and by overlapping arcs enabled RapidArc plans to produce dosimetrically improved plans for lung SBRT, but required more MUs (by a factor > 1.5) to deliver. The dosimetric improvements, most notably in PTV minimum dose and in dose conformality for irregularly shaped PTVs, may outweigh the increased MUs in using RapidArc. For small and peripherally located tumors, SiMs-arc produces comparable dosimetric quality and could be more efficient in both treatment planning and dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Metal–Organic-Framework-Supported and -Isolated Ceria Clusters with Mixed Oxidation States

The formation of oxygen vacancies via reversible transitions between Ce(IV) and Ce(III) plays a crucial role in the propensity of cerium oxide to act as a supporting promoter in oxidative heterogeneous catalysis. An open challenge is, however, preparation of high-porosity, supported arrays of isolated ceria(IV, III) clusters with high porosity. In this article, we report two examples of oxy-Ce(IV, III) clusters supported and spatially isolated on an oxy-zirconium MOF, NU-1000. The clusters are introduced using either of two Ce complexes (precursors): Ce IV (tmhd) 4 (tmhd = 2,2,6,6-tetramethyl-3,5-heptanedionate) or Ce III (iPrCp) 3 (iPrCp = tris(isopropyl-cyclopenta-dienyl), via SIM (solvothermal installation in MOFs). The prepared materials are named Ce-l-SIM-NU-1000 and Ce-n-SIM-NU-1000, respectively. X-ray photoelectron spectroscopy characterization shows that the ratio of Ce(III) to Ce(IV) oxidation states can be modulated. Difference envelope density analyses of X-ray scattering show that Ce x O y H z clusters in Ce-n-SIM-NU-1000 are located between pairs of Zr6 nodes, whereas in Ce-l-SIM-NU-1000, they are sited on MOF linkers throughout the micropores of NU-1000. Cluster size differences were further evaluated by pair function distribution (PDF) analyses of total X-ray scattering reveal that the node sited clusters contain of only a few cerium ions, whereas the linker-sited clusters each contain ~90 cerium ions. The observed size appears to be defined by the size of NU-1000s triangular pores, that is, cluster formation appears to be pore templated. The Ce-SIM functionalized materials are catalytically active for hydrolysis of DMNP (dimethyl 4-nitrophenyl phosphate), a nerve-agent simulant. Conversion of a small fraction of the Ce(IV) ions in which the presence of small fractions of the cerium(IV) ions in Ce-l-SIM-NU-1000 to cerium(III) significantly enhances catalytic activity-perhaps by labilizing aqua ligands and facilitating simulant binding to the clusters Lewis-basic metal ions. While not explored here, the larger clusters, when partially reduced, are, we believe, candidate catalysts for O 2 activation and subsequent selective oxidation of organic substrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties of a fading AGN from SDSS-IV MaNGA

ABSTRACT We identify a fading AGN SDSS J220141.64+115124.3 from the internal Product Launch-11 (MPL-11) in Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey. The central region with a projected radius of $\sim$2.4 kpc is characterized as LINER-like line ratios while the outskirts extended to $\sim$15 kpc show Seyfert-like line ratios. The ${\rm{[O {\small III}]}}$$\lambda$5007 luminosity of the Seyfert regions is a factor of 37 (2) higher than the LINER regions without (with) dust attenuation correction, suggesting that the AGN activity decreases at least $\sim$8 $\times$ 10$^3$ yr ($\sim$2.4 kpc/light-speed) ago. We model the emission line spectra in the central region with double Gaussian components (a narrow core and a broad wing) and analyse the properties of each component. The narrow core component mostly co-rotates with the stellar disc, whereas the broad wing component with a median of the velocity dispersion $\sim$300 km s$^{-1}$ is related to a wind outflow. The kinematic position angle (PA) of the ionized gas shows an $\sim 20^{\circ }$ twist from the galaxy centre to 1.5 effective radius. The median of the PA difference between the gas and stellar components is as large as $\sim 50^{\circ }$ within 0.4 effective radius. The tidal feature in DESI image and star–gas misalignment suggest this galaxy is a merger remnant. Combining all these observational results as well as public available X-ray and MIR luminosities, we confirm this is a fading AGN, the merger process kick-started the central engine to quasar phase which ionized gas composed of tidal debris, and now the activity of the central black hole decreases. The discontinuity in ${\rm{[O {\small III}]}}$$\lambda$5007 flux and EQW maps is due to multiple AGN outbursts triggered by merger remnant gas inflows.

Mo, Hao (ORCID:0000000234430768)↗

Inspection of next-generation EUV resists with nano-projectile secondary ion mass spectrometry

There is a rapidly growing need for new materials for extreme ultraviolet (EUV) lithography, which incorporate high EUV absorbing elements. Hybrid resists, which are a combination of inorganic and organic moieties, are promising as they offer both high EUV sensitivity and high etch resistance. However, there is a glaring lack of methods to examine the uniformity of these important materials at the nanoscale. We examine the capabilities of nano-projectile secondary ion mass spectrometry (NP-SIMS) to investigate hybrid resists. NP-SIMS is a mass spectrometry-based technique with high lateral resolution. Using NP-SIMS, a surface is probed stochastically with a suite of individual projectiles, 10 6 to 10 7 in total, separated in time and space. Examining these individual mass spectra allows for nanoscale investigation of the uniformity of the surface. We evaluated the performance of NP-SIMS using samples of poly(methyl methacrylate) (PMMA) infiltrated with varying amounts of InO x via vapor-phase infiltration (VPI), an organic–inorganic hybridization method derived from atomic layer deposition. Here, we found that NP-SIMS measurements contained abundant characteristic ions related to both the PMMA and infiltrated In. The intensity of In atomic ions increased linearly with the number of infiltration cycles; however, the uniformity of In and PMMA varied with the number of infiltration cycles. After one cycle, we found that both the PMMA and In were relatively inhomogeneous. The homogeneity improved with subsequent infiltration cycles. In addition, NP-SIMS measurements contained characteristic ions related to the infiltration reaction and provided insights into the VPI mechanism. Overall, the results show that NP-SIMS is capable of examining both the inorganic and organic moieties in a hybrid resist and will be an important method for understanding the performance of these materials for use in EUV lithography.

36 MATERIALS SCIENCE↗

SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between the plans on CT-sim with assigned CT-number and the deformable SEMAR CT datasets.

60 APPLIED LIFE SCIENCES↗

Evaluation of micromilling/conventional isotope ratio mass spectrometry and secondary ion mass spectrometry of δ 18 O values in fish otoliths for sclerochronology

Stable oxygen isotope ratios (δ 18 O values) measured in fish otoliths can provide valuable detailed information on fish life history, fish age determination, and ocean thermography. Traditionally, otoliths are sampled by micromilling followed by isotope ratio mass spectrometry (IRMS), but direct analysis by secondary ion mass spectrometry (SIMS) is becoming more common. However, these two methods have not been compared to determine which, if either, is better for fish age validation studies. Hence, the goals were to: (1) determine if the δ 18 O signatures from the two different methods are similar, (2) determine which method is better for fish age validation studies, and (3) examine biogeographic and migration history. Both analytical techniques, micromilling/IRMS and SIMS, were used to measure δ 18 O values in six Pacific cod (Gadus macrocephalus) otoliths. A series of measurements was made from the center of each otolith to its edge to develop a life-history δ 18 O signature for each fish. The sampling resolution of SIMS analyses was 2–3 times greater than that obtained by micromilling/IRMS. We found an offset between SIMS and micromilling/IRMS δ 18 O values, about 0.5‰ on average, with SIMS yielding lower values. However, the δ 18 O patterns from both methods (i.e., the number of δ 18 O maxima) correspond to the estimated age determined by otolith growth-zone counts, validating fish age determination methods. Both techniques resolved δ 18 O life-history signatures and showed patterns consistent with seasonal variation in temperatures and changes due to fish migration. When otoliths are large, micromilling/IRMS can provide adequate resolution for fish age validation. Finally, SIMS is the better option if greater sampling resolution is required, such as when otoliths are small or specimens are longer lived and have compact growth zones.

54 ENVIRONMENTAL SCIENCES↗

Effect of wind pressure and modulation schemes on rain interrupted optical wireless links under tropical climates

Tropical and subtropical regions experience heavy rain intensities often accompanied with medium to strong winds. In this work, the effect of perpendicular wind flow and various modulation formats on a rain interrupted optical wireless link is investigated experimentally under controlled laboratory conditions. Attenuation as a function of rain rate is observed at different wind pressure. It is found that rain induced scattering dominates the rain specific attenuation however significant attenuation is expected at much higher wind pressure which normally increases with altitudes. A comparative performance of modulation formats like direct intensity modulation (D-IM), pulse width modulation (PWM) and various subcarrier intensity modulated (SIM) signals under heavy rain conditions is reported. It is found that SIM-FSK and SIM-AM offer better signal to noise performance (approximately two times) followed by subcarrier phase (SIM-PM) and frequency (SIM-FM) respectively. Also, SIM-FSK and PWM are least attenuated in heavy precipitation.

42 ENGINEERING↗

Transfer learning-based soybean LAI estimations by integrating PROSAIL, UAV, and PlanetScope imagery

Accurate Leaf Area Index (LAI) estimations at the soybean plot scale is achievable using high-resolution Unmanned Aerial Vehicle (UAV) imagery and field measurement samples. However, the limited coverage of UAV flights restricts large-scale remote sensing monitoring in expansive soybean fields. This study leverages the broad coverage and 3-m resolution of PlanetScope satellite imagery to extend LAI prediction from UAV to satellite scales through transfer learning, using UAV-scale LAI estimates as a benchmark to validate cross-scale consistency. To address this challenge, this study proposed the LAI-TransNet, a two-stage transfer learning framework designed for precise and scalable soybean LAI prediction across large areas, demonstrating its effectiveness in cross-scale monitoring. In Stage 1, a UAV-scale benchmark is established using PROSAIL-simulated UAV reflectance data (UAV-Sim) and field-measured soybean LAI. Traditional machine learning, deep learning, and transfer learning models are trained on a hybrid UAV-Sim and field-measured dataset (UAV-Sim_Measured), with the transfer learning model CNN-TL, fine-tuned using pre-trained weights derived from UAV-Sim, achieving the highest accuracy (R 2 = 0.81, RMSE = 0.64 m 2 /m 2 , rRMSE = 11.5 %). In Stage 2, LAI-TransNet is developed by fine-tuning the CNN-TL model on PlanetScope simulated data (PS-Sim), preprocessed via cross-domain mapping to align UAV and satellite spectral features. Real PlanetScope imagery is corrected for reflectance consistency with reference to UAV imagery spectral profiles. LAI-TransNet outperforms other deep learning models trained directly on PS-Sim (R 2 = 0.69 vs. 0.60–0.63), ensuring robust cross-scale consistency. In conclusion, by bridging UAV and satellite scales, LAI-TransNet enables large-scale soybean LAI monitoring, enhancing precision agriculture management through improved monitoring with the PlanetScope imagery.

Leaf area index (LAI)↗

Enhanced SUMOylation of proteins containing a SUMO-interacting motif by SUMO-Ubc9 fusion

Identifying new targets for SUMO and understanding the function of protein SUMOylation are largely limited by low level of SUMOylation. It was found recently that Ubc9, the SUMO E2 conjugating enzyme, is covalently modified by SUMO at a lysine 14 in the N-terminal alpha helix, and that SUMO-modified Ubc9 has enhanced conjugation activity for certain target proteins containing a SUMO-interacting motif (SIM). Here, we show that, compared to intact Ubc9, the SUMO-Ubc9 fusion protein has higher conjugating activity for SIM-containing targets such as Sp100 and human cytomegalovirus IE2. Assays using an IE2 SIM mutant revealed the requirement of SIM for the enhanced IE2 SUMOylation by SUMO-Ubc9. In pull-down assays with cell extracts, the SUMO-Ubc9 fusion protein bound to more diverse cellular proteins and interacted with some SIM-containing proteins with higher affinities than Ubc9. Therefore, the devised SUMO-Ubc9 fusion will be useful for identifying SIM-containing SUMO targets and producing SUMO-modified proteins.

60 APPLIED LIFE SCIENCES↗

Implementation of a Novel Algorithm For Generating Synthetic CT Images From Magnetic Resonance Imaging Data Sets for Prostate Cancer Radiation Therapy

Purpose: To describe and evaluate a method for generating synthetic computed tomography (synCT) images from magnetic resonance simulation (MR-SIM) data for accurate digitally reconstructed radiograph (DRR) generation and dose calculations in prostate cancer radiation therapy. Methods and Materials: A retrospective evaluation was performed in 9 prostate cancer patients who had undergone MR-SIM in addition to CT simulation (CT-SIM). MR-SIM data were used to generate synCT images by using a novel, voxel-based weighted summation approach. A subset of patients was used for weight optimization, and the number of patients to use during optimization was determined. Hounsfield unit (HU) differences between CT-SIM and synCT images were analyzed via mean absolute error (MAE). Original, CT-based treatment plans were mapped onto synCTs. DRRs were generated, and agreement between CT and synCT-generated DRRs was evaluated via Dice similarity coefficient (DSC). Dose was recalculated, and dose-volume metrics and gamma analysis were used to evaluate resulting treatment plans. Results: Full field-of-view synCT MAE across all patients was 74.3 ± 10.9 HU with differences from CTs of 2.0 ± 8.1 HU and 11.9 ± 46.7 HU for soft tissue structures (prostate, bladder, and rectum) and femoral bones, respectively. Calculated DSCs for anterior-posterior and lateral DRRs were 0.90 ± 0.04 and 0.92 ± 0.05, respectively. Differences in D99%, mean dose, and maximum dose to the clinical target volume from CT-SIM dose calculations were 0.75% ± 0.35%, 0.63% ± 0.34%, and 0.54% ± 0.33%, respectively, for synCT-generated plans. Gamma analysis (2%/2 mm dose difference/distance to agreement) revealed pass rates of 99.9% ± 0.1% (range, 99.7%-100%). Conclusion: Generated synCTs enabled accurate DRR generation and dose computation for prostate MR-only simulation. Dose recalculated on synCTs agreed well with original planning distributions. Further validation using a larger patient cohort is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MeV Au Ion Irradiation in Silicon and Nanocrystalline Zirconia Film Deposited on Silicon Substrate

Nanocrystalline zirconia (ZrO2) film with thickness of 305 nm deposited on a silicon substrate was irradiated with 2 MeV Au ions to different fluences at different temperatures. The implanted ion profiles were measured by time-of-flight secondary ion mass spectrometry (ToF-SIMS) and simulated using the stopping and range of ions inmatter (SRIM) code, respectively. The experimental results show that a large fraction of the incident Au ions penetrates through the ZrO2 film and are deposited into the Si substrate. At the interface of ZrO2 and Si, a sudden decrease of Au concentration is observed due to the much larger scattering cross section of Au in ZrO2 than in Si. The depth profile of the Au ions is measured in both the ZrO2 films and the Si substrates, and the results show that the Au distribution profiles do not exhibit a dependence on irradiation temperature. The local Au concentration increases proportionally with the irradiation fluence, suggesting that no thermal or irradiation-induced redistribution of the implanted Au ions. However, the Au concentration in the ZrO2 films, as determined by SIMS, is considerably lower than that predicted by the SRIM results, and the penetration depth from the SIMS measurements is much deeper than that from the SRIM predictions. These observations can be explained by an overestimation of the electronic stopping power, used in the SRIM program, for heavy incident ions in light targets. Over-estimation of the heavy-ion electronic stopping power may lead to errors in local dose calculation and underestimation of the projected range of slow heavy ions in targets that contain light elements. A quick estimate based on a reduced target density may be used to compensate the overestimation of the electronic stopping power in the SRIM program to provide better ion profile prediction.

Environmental Molecular Sciences Laboratory↗

Comparison Between Simulated And Experimental Au-ion Profiles Implanted in nanocrystalline ceria

Radiation response of nanocrystalline ceria films deposited on a silicon substrate was investigated under a 3-MeV Au-ion irradiation at 300 K. A uniform grain growth cross the ceria films is observed and effective densification of the ceria thin films occurs during irradiation. The Au ion profiling was measured by secondary ion mass spectrometry (SIMS) and compared to the Au ion distribution predicted by the Stopping and Range of Ions in Solids (SRIM) code. It is observed that the Au-ion penetration depth is underestimated in comparison with the SIMS measurements. An overestimation of the electronic stopping power for heavy incident ions in the SRIM program may account for the discrepancies between the calculations and the SIMS experimental results. This work presents an approach to compensate the overestimation of the electronic stopping powers in the SRIM program by adjusting the nanocrystalline ceria target density to better predict the ion implantation profile.

Environmental Molecular Sciences Laboratory↗

In Situ Liquid Secondary Ion Mass Spectrometry: A Surprisingly Soft Ionization Process for Investigation of Halide Ion Hydration

The understanding of ion solvation phenomenon is of significance due to their influences on many important chemical, biological and environmental processes. Mass spectrometry (MS) based methods have been used to investigate this topic with molecular insights. As ion-solvent interactions are weak, ionization processes should be as soft as possible in order to retain solvation structures. An in situ liquid secondary ion MS (SIMS) approach developed in our group has been recently utilized in investigations of Li ion solvation in non-aqueous solution and detected a series of solvated Li ions. As traditionally SIMS has long been recognized as a hard ionization process with strong damage occurring at the sputtering interface, it is very interesting to study further how soft in situ liquid SIMS can be. In this work, we used halide ion hydration as an example to compare the ionization performance of in situ liquid SIMS approach with regular electrospray ionization MS (ESI-MS). Results show that although ESI has been recognized as a soft ionization method, nearly no solvated halide ions were detected by ESI-MS analysis, which acquired only strong signals of salt ion clusters. In contrast, in liquid SIMS spectra, a series of obvious hydrated halide ion compositions could be observed. We further evaluated the hydration numbers of halide ions and revealed the effects of the ion size, charge density and polarizability on the hydration phenomenon. Our findings demonstrated that the in situ liquid SIMS approach is surprisingly soft, and expected to have very broad applications on investigation of various ion-solvent interactions and many other interesting chemical processes (e.g., the initial nucleation of nanoparticle formation) in liquid environment.

Zhang, Yanyan↗