Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Overview of Integrated Random Vibration Testing of the NASA Orion Crew Survival Suit

The launch ascent and abort random vibration environments from NASA’s Orion spacecraft drove the need to test the NASA Orion Crew Survival Suit as an integrated system with exposure to the design levels. In order to properly characterize component responses, a series of integrated tests were designed to incorporate the interaction between a crew member, suit, seat, and the attenuation system. The first Development Test (2017) included human subjects, and was performed with early development seat and suit components, and low level inputs. It provided a baseline for frequency response and behavior of the integrated system. The next two tests, Development Test (2019) and Qualification Test (2020), used manikin surrogates to represent the crew member and increasing levels of component hardware fidelity in order to test to higher input levels. Testing was performed at NASA Johnson Space Center (JSC) and Kennedy Space Center (KSC) Vibration Labs and provided the input levels required to represent the ascent and abort vehicle profiles as well as recorded component response behavior from accelerometer instrumentation and high speed cameras. Inspection of the suit and related components showed that for all seat orientations, and input environments, no damage occurred. Additional pre and post-test checks confirmed the functionality of all suited hardware. Response data of the suited components generally showed heavy attenuation across most of the tested frequency range. Transmissibility plots showed some amplification of components at lower frequency ranges. Overall this series of integrated tests showed that 1) the use of surrogate manikins in the tests were adequate for representing crew in a vibration environment, 2) full vibration levels for ascent and abort were heavily attenuated in the suit components and were non-damaging, and 3) the suit and related components are qualified for the Orion random vibration environments.

Jeffrey D Suhey↗

Overview of Integrated Random Vibration Testing of the NASA Orion Crew Survival Suit

The launch ascent and abort random vibration environments from NASA’s Orion spacecraft drove the need to test the NASA Orion Crew Survival Suit as an integrated system with exposure to the design levels. In order to properly characterize component responses, a series of integrated tests were designed to incorporate the interaction between a crew member, suit, seat, and the attenuation system. The first Development Test (2017) included human subjects, and was performed with early development seat and suit components, and low level inputs. It provided a baseline for frequency response and behavior of the integrated system. The next two tests, Development Test (2019) and Qualification Test (2020), used manikin surrogates to represent the crew member and increasing levels of component hardware fidelity in order to test to higher input levels. Testing was performed at NASA Johnson Space Center (JSC) and Kennedy Space Center (KSC) Vibration Labs and provided the input levels required to represent the ascent and abort vehicle profiles as well as recorded component response behavior from accelerometer instrumentation and high speed cameras. Inspection of the suit and related components showed that for all seat orientations, and input environments, no damage occurred. Additional pre and post-test checks confirmed the functionality of all suited hardware. Response data of the suited components generally showed heavy attenuation across most of the tested frequency range. Transmissibility plots showed some amplification of components at lower frequency ranges. Overall this series of integrated tests showed that 1) the use of surrogate manikins in the tests were adequate for representing crew in a vibration environment, 2) full vibration levels for ascent and abort were heavily attenuated in the suit components and were non-damaging, and 3) the suit and related components are qualified for the Orion random vibration environments.

Jeffrey Suhey↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Understanding how critical mission tasks are performed in partial gravity such as on the moon or Mars is necessary to define effective and comprehensive countermeasure strategies for preserving crew performance during exploration missions. We studied the performance of tasks such as standing, balancing, walking, and jumping during the partial gravity phases of parabolic flight. We hypothesized that the acute effects of partial gravity on vestibular, proprioceptive, and sensorimotor functions would negatively impact performance. METHODS Twelve subjects (6F, 6M; 40.2 ± 8.5 years) were tested over three flights of 30 parabolas each, including 10 parabolas at 0.25g, 10 parabolas at 0.5g, and 10 parabolas at 0.75g. Subjects also performed tests in 1g between parabolas. During the seat egress and walk task, subjects rose from a seated position and walked as quickly as possible straight ahead towards a cone (4 m distance), stepped over a 30 cm high obstacle, walked around the cone making a 180° left turn, returned to the chair, and sat down in the chair. Other tasks included a tandem stance on rails, jump down from a 30cm platform, recovery from fall (prone to stand), and limits of stability tasks. Data were collected using inertial measurement units (Opal V2, APDM, Portland, OR) worn on the head and trunk, heart rate monitors (Polar, Finland), and a force plate (Bertec, Columbus, OH). During the jump down and limits of stability tasks, falls were recorded if subjects took extra steps, lifted their heels/toes, or used their arms to recover balance. RESULTS Gravity level had a significant effect on performance, with the greatest changes from 1g tending to be at the 0.25g level (Table 1). Lower gravity levels were associated with increased times to complete the seat egress and walk task and the recovery from fall task, increased head-trunk coordination, decreased tandem stance rail balance times, decreased change in heart rate during the recovery from fall task, and increased cone of stability distance in the anterior-posterior direction. In addition, there were significantly more falls recorded at the lower gravity levels: 31 falls at 0.25g, 14 falls at 0.5g, 6 falls at 0.75g, and 6 falls at 1g. DISCUSSION These data suggest that there is a dose-response relationship between gravity level and functional task performance. The largest changes in performance were expected at the lowest gravity level (0.25g) because subjects would no longer be able to use the gravitational reference for the perception of upright. Understanding the extent of performance deficits informs the risks and design of countermeasures for exploration spaceflight missions.

T R Macaulay↗

A Summary of Results from Vertical Drop Testing of Hybrid III and WIAMan ATDs

With the development and maturation of the Urban Air Mobility (UAM) market, many new types of electric vertical take-off and landing (eVTOL) vehicles will be flying in the national airspace carrying goods, people or conducting operations for a variety of missions. These types of vehicles are unlike current aircraft due to their novel design and operational profile. Several considerations must be examined in areas including noise, comfort and safety in order for these vehicles to be utilized and accepted into the current airspace system. Researchers at NASA Langley Research Center (LaRC) have conducted sub-scale and full-scale tests on representative eVTOL airframes and seats under a variety of dynamic impact conditions. These tests were conducted to generate data necessary to inform the development of standards in the areas specific to crashworthiness of eVTOL vehicle systems and safety. The data in this report relates to occupant responses obtained during a test campaign utilizing various makes, models, and sizes of Anthropomorphic Test Devices (ATD’s, a.k.a. crash test dummies) undergoing vertical impacts in a variety of seats. The data is intended to provide occupant behavior response and injury metrics for several anticipated impact scenarios that may occur in eVTOL operations. This report will present test data highlighting the effects of several variables on the test results. Discussions on the ATD sizes, along with comparisons between different ATD makes and types will be included. The performance of an in-house developed energy absorbing seat will be detailed, and discussions pertaining to the applicability in various loading conditions will be presented. Finally, a discussion as to the applicability of the tested results to eVTOL full-scale conditions will be included.

Dynamic Drop Testing↗

Passive integral isolation valve

A valve assembly includes a flange connected to a vessel penetration of a reactor pressure vessel of a nuclear reactor. A valve is disposed inside the flange or protrudes from the flange into the vessel penetration. The valve includes a valve seat and a movable valve member positioned so that pressure inside the reactor pressure vessel urges the movable valve member against the valve seat to close the valve. The valve assembly further includes a plenum having an inlet via which the plenum can be pressurized to apply pressure to the movable valve member that urges the movable valve member away from the valve seat to open the valve. The plenum may be defined in part by a surface of the movable valve member. The valve assembly preferably does not include a valve actuator.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiosynthesis and Biodistribution of {sup 99m}Tc-Metronidazole as an Escherichia coli Infection Imaging Radiopharmaceutical

Bacterial infection poses life-threatening challenge to humanity and stimulates to the researchers for developing better diagnostic and therapeutic agents complying with existing theranostic techniques. Nuclear medicine technique helps to visualize hard-to-diagnose deep-seated bacterial infections using radionuclide-labeled tracer agents. Metronidazole is an antiprotozoal antibiotic that serves as a preeminent anaerobic chemotherapeutic agent. The aim of this study was to develop technetium-99m-labeled metronidazole radiotracer for the detection of deep-seated bacterial infections. Radiosynthesis of {sup 99m}Tc-metronidazole was carried by reacting reduced technetium-99m and metronidazole at neutral pH for 30 min. The stannous chloride dihydrate was used as the reducing agent. At optimum radiolabeling conditions, ~ 94% radiochemical was obtained. Quality control analysis was carried out with a chromatographic paper and instant thin-layer chromatographic analysis. The biodistribution study of radiochemical was performed using Escherichia coli bacterial infection-induced rat model. The scintigraphic study was performed using E. coli bacterial infection-induced rabbit model. The results showed promising accumulation at the site of infection and its rapid clearance from the body. The tracer showed target-to-non-target ratio 5.57 ± 0.04 at 1 h post-injection. The results showed that {sup 99m}Tc-MNZ has promising potential to accumulate at E. coli bacterial infection that can be used for E. coli infection imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subcellular localization of leptin and leptin receptor in breast cancer detected in an electron microscopic study

Leptin (LEP) and leptin receptor (LEPR) have long been found associated with breast cancer. So far no high-resolution method such as electron microscopy has been used to investigate the subcellular localization of leptin and leptin receptor in breast cancer. We collected cancer and non-cancer breast tissues from 51 women with invasive ductal breast cancer. Leptin and leptin receptor in the tissues were estimated using immunohistochemistry (IHC). LEP and LEPR were localized at subcellular level by immunocytochemistry (ICC) using ultra-fine gold particle conjugated antibody, and visualized with transmission electron microscopy (TEM). IHC showed high presence of LEP and LEPR in 65% and 67% respectively of the breast cancer samples, 100% and 0% respectively of the adipose tissue samples, and no high presence in the non-cancer breast tissue samples. On TEM views both LEP and LEPR were found highly concentrated within the nucleus of the cancer cells, indicating that nucleus is the principal seat of action. However, presence of high concentration of LEP does not necessarily prove its over-expression, as often concluded, because LEP could be internalized from outside by LEPR in the cells. In contrast, LEPR is definitely over-expressed in the ductal breast cancer cells. Therefore, we hypothesize that over-expression of LEPR, rather than that of LEP has a fundamental role in breast carcinogenesis in particular, and probably for LEP-LEPR associated tumors in general. - Highlights: • Leptin-leptin receptor complex is localized mostly in and around the nucleus. • Nucleus might be the final seat of action of leptin-leptin receptor complex. • Immunohistochemistry can prove over-expression of leptin receptor, not of leptin. • Over-expression of leptin receptor is of primary importance in breast cancer.

60 APPLIED LIFE SCIENCES↗

Applications of Nd:YAG laser micromanufacturing in High Temperature Gas Reactor research

Two innovative applications of Nd:YAG laser micromachining techniques are demonstrated in this publication. Research projects to determine the fission product transport mechanisms in TRISO coated particles necessitate heat treatment studies as well as the manufacturing of a unique sealed system for experimentation at very high temperatures. This article describes firstly the design and creation of an alumina jig designed to contain 500 {mu}m diameter ZrO2 spheres intended for annealing experiments at temperatures up to 1600 C. Functional requirements of this jig are the precision positioning of spheres for laser ablation, welding and post weld heat treatment in order to ensure process repeatability and accurate indexing of individual spheres. The design challenges and the performance of the holding device are reported. Secondly the manufacture of a sealing system using laser micromachining is reported. ZrO2 micro plugs isolate the openings of micro-machined cavities to produce a gas-tight seal fit for application in a high temperature environment. The technique is described along with a discussion of the problems experienced during the sealing process. Typical problems experienced were seating dimensions and the relative small size ({approx} 200 {mu}m) of these plugs that posed handling challenges. Manufacturing processes for both the tapered seating cavity and the plug are demonstrated. In conclusion, this article demonstrates the application of Nd-YAG micromachining in an innovative way to solve practical research problems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Activated ClpP kills persisters and eradicates a chronic biofilm infection.

The current antibiotic crisis stems from two distinct phenomena-drug resistance, and drug tolerance. Resistance mechanisms such as drug efflux or modification prevent antibiotics from binding to their targets 1, allowing pathogens to grow. Antibiotic tolerance is the property of persister cells, phenotypic variants of regular bacteria 2. Antibiotics kill by corrupting targets, but these are inactive in dormant persisters, leading to tolerance. Persisters were first identified by Joseph Bigger in 1944, when he discovered a surviving sub-population of Staphylococcus following treatment with penicillin3. Persisters are largely responsible for recalcitrance of chronic diseases such as tuberculosis, and various infections associated with biofilms - endocarditis, osteomyelitis, infections of catheters and indwelling devices, and deep-seated infections of soft tissues 4. There are a number of redundant pathways involved in persister formation5,6 precluding development of drugs inhibiting their formation. The acyldepsipeptide antibiotic (ADEP 4) has been shown to activate the ClpP protease resulting in death of growing cells 7. Here we show that ADEP4 activated ClpP becomes a fairly non-specific protease and kills persister cells by degradation of over 400 intracellular targets. clpP mutants are resistant to ADEP4 7, but we find that they display increased susceptibility to killing by a range of conventional antibiotics. Combining ADEP4 with rifampicin leads to eradication of persisters, stationary and biofilm populations of Staphylococcus aureus in vitro and in a deep-seated murine infection. Target corruption/activation provides an approach to killing persisters and eradicating chronic infections.

Environmental Molecular Sciences Laboratory↗

High-pressure high-temperature phase diagram of gadolinium studied using a boron-doped heater anvil

A boron-doped designer heater anvil is used in conjunction with powder x-ray diffraction to collect structural information on a sample of quasi-hydrostatically loaded gadolinium metal up to pressures above 8 GPa and 600 K. The heater anvil consists of a natural diamond anvil that has been surface modified with a homoepitaxially grown chemical-vapor-deposited layer of conducting boron-doped diamond, and is used as a DC heating element. Internally insulating both diamond anvils with sapphire support seats allows for heating and cooling of the high-pressure area on the order of a few tens of seconds. This device is then used to scan the phase diagram of the sample by oscillating the temperature while continuously increasing the externally applied pressure and collecting in situ time-resolved powder diffraction images. In the pressure-temperature range covered in this experiment, the gadolinium sample is observed in its hcp, αSm, and dhcp phases. Under this temperature cycling, the hcp → αSm transition proceeds in discontinuous steps at points along the expected phase boundary. From these measurements (representing only one hour of synchrotron x-ray collection time), a single-experiment equation of state and phase diagram of each phase of gadolinium is presented for the range of 0–10 GPa and 300–650 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Eruptive Activity on the Western Flank of Piton de la Fournaise (La Réunion Island, Indian Ocean): Insights on Magma Transfer, Storage and Evolution at an Oceanic Volcanic Island

Abstract Petrological and geochemical (major element, trace element, Sr–Nd isotope) data for recent (<5 kyr old) basalts that sporadically erupt on the western flank of Piton de la Fournaise (PdF), one of the most active volcanoes on Earth, allow the tracking of magma transfer and evolution from mantle to crustal depths. In the western peripheral area of PdF we document the broadly synchronous eruptions of (1) primitive olivine and olivine–clinopyroxene transitional basalts with tholeiitic affinity that are closely associated in space with (2) transitional olivine basalts with alkaline affinity, and (3) hybrid lavas, intermediate between the ‘alkaline’ and the ‘tholeiitic’ end-members. The composition of the latter overlaps with that of the lavas frequently erupted from the conduit system feeding the main summit cone. AlphaMELTS modelling, and fluid inclusion and clinopyroxene barometry, constrain the conditions of magma storage at 10–30 km, and the ascent of magma from the upper mantle to the shallow crustal plumbing system. Variable degrees of mantle melting, together with minor source heterogeneity and contamination with cumulate-derived partial melts, contribute to the diversity of PdF magmas. However, all these processes do not represent the dominant factors that produce the large variability we found in major element composition. Indeed, the composition of basalts erupted from PdF peripheral centers is strongly controlled by polybaric olivine–clinopyroxene fractionation at pressures higher than 3 kbar. Crystal textures and geochemical modelling suggest that fast magma ascent is critical to prevent clinopyroxene dissolution. Conversely, long-lasting magma stagnation promotes pyroxene resorption and magma differentiation. ‘Central’ eruptions occurring close to the PdF summit cone emit variably more evolved melts, which result from olivine–clinopyroxene–plagioclase differentiation at intermediate–shallow pressure (<3 kbar and in most cases <1 kbar). Deep and extensive magma mixing before injection into the crustal magma conduit system, located below the summit region, results in the apparent homogeneity of basalts erupted from the central area. As regards ‘peripheral’ eruptions, deep-seated stagnation of basaltic melts and differentiation at the mantle–crust transition zone (c. 4 kbar) produces a range of magma compositions. We demonstrate that rapid magma ascent from deep-seated reservoirs can bypass the central plumbing system. The eruptions of these magmas both in the central area and on the densely populated flanks have major consequences in terms of volcanic hazard at PdF.

Boudoire, G.↗

Modality comparison for small animal radiotherapy: A simulation study

Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by the SARRP plan due to the sensitivity of the lower energy microCT beam to target heterogeneities and image noise. Conclusions: The two treatment planning examples demonstrate that modern small animal radiotherapy techniques employing image guidance, variable collimation, and multiple beam angles deliver superior dose distributions to small animal tumors as compared to conventional treatments using a single-field irradiator. For deep-seated mouse tumors, however, higher-energy conformal radiotherapy could result in higher doses to critical organs compared to lower-energy conformal radiotherapy. Treatment planning optimization for small animal radiotherapy should therefore be developed to take full advantage of the novel conformal systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Z linac targets for low-MV gold nanoparticle radiation therapy

Purpose: To investigate the potential of low-Z/low-MV (low-Z) linac targets for gold nanoparticle radiotherapy (GNPT) and to determine the microscopic dose enhancement ratio (DER) due to GNP for the alternative beamlines. In addition, to evaluate the degradation of dose enhancement arising from the increased attenuation of x rays and larger skin dose in water for the low-MV beams compared to the standard linac. Methods: Monte Carlo simulations were used to compute dose and DER for various flattening-filter-free beams (2.5, 4, 6.5 MV). Target materials were beryllium, diamond, and tungsten-copper high-Z target. Target thicknesses were selected based on 20%, 60%, 70%, and 80% of the continuous slowing down approximation electron ranges for a given target material and energy. Evaluation of the microscopic DER was carried out for 100 nm GNP including the degradation factors due to beam attenuation. Results: The greatest increase in DER compared to the standard 6.5 MV linac was for a 2.5 MV Be-target (factor of ∼2). Skin dose ranged from ∼10% (Be, 6.5 MV-80%) to ∼85% (Be, 2.5 MV-20%) depending on the target case. Attenuation of 2.5 MV beams at 22 cm was higher by ∼75% compared with the standard beam. Taking into account the attenuation at 22 cm depth, the effective dose enhancement was up to ∼60% above the DER of the high-Z target. For these cases the effective DER ranged between ∼1.6 and 6 compared with the standard linac. Conclusions: Low-Z (2.5 MV) GNPT is possible even after accounting for greater beam attenuation for deep-seated tumors (22 cm) and the increased skin dose. Further, it can lead to significant sparing of normal tissue while simultaneously escalating the dose in the tumor cells.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-P-30: Clinical Applications of Spatially Fractionated Radiation Therapy (GRID) Using Helical Tomotherapy

Purpose: To present the first clinical applications of Helical Tomotherapy-based spatially fractionated radiotherapy (HT-GRID) for deep seated tumors and associated dosimetric study. Methods: Ten previously treated GRID patients were selected (5 HT-GRID and 5 LINAC-GRID using a commercially available GRID block). Each case was re-planned either in HT-GRID or LINAC-GRID for a total of 10 plans for both techniques using same prescribed dose of 20 Gy to maximum point dose of GRID GTV. For TOMO-GRID, a programmable virtual TOMOGRID template mimicking a GRID pattern was generated. Dosimetric parameters compared included: GRID GTV mean dose (Dmean) and equivalent uniform dose (EUD), GRID GTV dose inhomogeneity (Ratio(valley/peak)), normal tissue Dmean and EUD, and other organs-at-risk(OARs) doses. Results: The median tumor volume was 634 cc, ranging from 182 to 4646 cc. Median distance from skin to the deepest part of tumor was 22cm, ranging from 8.9 to 38cm. The median GRID GTV Dmean and EUD was 10.65Gy (9.8–12.5Gy) and 7.62Gy (4.31–11.06Gy) for HT-GRID and was 6.73Gy (4.44–8.44Gy) and 3.95Gy (0.14–4.2Gy) for LINAC-GRID. The median Ratio(valley/peak) was 0.144(0.05–0.29) for HT-GRID and was 0.055(0.0001–0.14) for LINAC-GRID. For normal tissue in HT-GRID, the median Dmean and EUD was 1.24Gy (0.34–2.54Gy) and 5.45 Gy(3.45–6.89Gy) and was 0.61 Gy(0.11–1.52Gy) and 6Gy(4.45–6.82Gy) for LINAC-GRID. The OAR doses were comparable between the HT-GRID and LINAC-GRID. However, in some cases it was not possible to avoid a critical structure in LINAC-GRID; while HT-GRID can spare more tissue doses for certain critical structures. Conclusion: HT-GRID delivers higher GRID GTV Dmean, EUD and Ratio(valley/peak) compared to LINAC-GRID. HT-GRID delivers higher Dmean and lower EUD for normal tissue compared to LINAC-GRID. TOMOGRID template can be highly patient-specific and allows adjustment of the GRID pattern to different tumor sizes and shapes when they are deeply-seated and cannot be safely treated with LINAC-GRID.

60 APPLIED LIFE SCIENCES↗

SU-E-T-93: Activation of Psoralen at Depth Using Kilovoltage X-Rays: Physics Considerations in Implementing a New Teletherapy Paradigm

Purpose: Psoralen is a UV-light activated anti-cancer biotherapeutic used for treating skin lesions (PUVA) and advanced cutaneous T-cell lymphoma (ECP). To date psoralen has not been used to treat deep seated tumors due to difficulty in generating UV-light at depth. We recently demonstrated psoralen activation at depth by introducing energy converting particles that absorb kV x-ray radiation and re-emit UV-light. Our in-vitro work found that 0.2–1Gy using 40–100kVp x-rays combined with psoralen and particles can induce a substantial apoptotic response beyond that expected from the sum of individual components. In preparation for a phase I clinical trial of canine companion animals, we address the physics and dosimetry considerations for applying this new teletherapy paradigm to an in-vivo setting. Methods: The kV on-board imaging (OBI) system mounted on a medical linear accelerator (Varian) was commissioned to deliver the prescribed dose (0.6Gy) using 80 and 100kVp. Dosimetric measurements included kVp, HVL, depth dose, backscatter factors, collimator and phantom scatter factors, field size factors, and blade leakage. Absolute dosimetry was performed following AAPM TG61 recommendations and verified with an independent kV dose meter. We also investigated collimated rotational delivery to minimize skin dose using simple dose calculations on homogeneous cylindrical phantoms. Results: Single beam delivery is feasible for shallow targets (<5cm) without exceeding skin tolerance, while a rotational delivery may be utilized for deeper targets; skin dose is ∼75% of target dose for 80kVp collimated rotational delivery to a 3cm target within a 20cm phantom. Heat loading was tolerable; 0.6Gy to 5cm can be delivered before the anode reaches 75% capacity. Conclusion: KV teletherapy for Psoralen activation in deep seated tissue was successfully commissioned for a Varian OBI machine for use in a phase I clinical trial in canines. Future work will use Monte Carlo dosimetry to investigate dose in presence of bone. Research funded by Immunolight LLC. H. Walder, Z. Fathi, & W. Beyer are employees of Immunolight LLC which holds a patent on the technology. Drs. Adamson and Oldham are consultants to Immunolight LLC.

60 APPLIED LIFE SCIENCES↗

Exploring the Interaction Between Head-Supported Mass, Posture, and Visual Stress on Neck Muscle Activation

Objective Assess neck muscle activity for varying interactions between helmet, posture, and visual stress in a simulated “helo-hunch” posture. Background Military aviators frequently report neck pain (NP). Risk factors for NP include head-supported mass, awkward postures, and mental workload. Interactions between these factors could induce constant low-level muscle activation during helicopter flight and better explain instances of NP. Method Interactions between physical loading (helmet doffed/donned), posture (symmetric/asymmetric), and visual stress (low/high contrast) were studied through neck muscle electromyography (EMG), head kinematics, subjective discomfort, perceived workload, and task performance. Subjects ( n = 16) performed eight 30-min test conditions (varied physical loading, posture, and visual stress) while performing a simple task in a simulated “helo-hunch” seating environment. Results Conditions with a helmet donned had fewer EMG median frequency cycles (which infer motor unit rotation for rest/recovery, where more cycles are better) in the left cervical extensor and left sternocleidomastoid. Asymmetric posture (to the right) resulted in higher normalized EMG activity in the right cervical extensor and left sternocleidomastoid and resulted in less lateral bending compared with neutral across all conditions. Conditions with high visual stress also resulted in fewer EMG cycles in the right cervical extensor. Conclusion A complex interaction exists between the physical load of the helmet, postural stress from awkward postures, and visual stress within a simulated “helo-hunch” seating environment. Application These results provide insight into how visual factors influence biomechanical loading. Such insights may assist future studies in designing short-term administrative controls and long-term engineering controls.

Behavioral Sciences↗

Electrostatic microvalves utilizing conductive nanoparticles for improved speed, lower power, and higher force actuation.

We have designed and built electrostatically actuated microvalves compatible with integration into a PDMS based microfluidic system. The key innovation for electrostatic actuation was the incorporation of carbon nanotubes into the PDMS valve membrane, allowing for electrostatic charging of the PDMS layer and subsequent discharging, while still allowing for significant distention of the valveseat for low voltage control of the system. Nanoparticles were applied to semi-cured PDMS using a stamp transfer method, and then cured fully to make the valve seats. DC actuation in air of these valves yielded operational voltages as low as 15V, by using a supporting structure above the valve seat that allowed sufficient restoring forces to be applied while not enhancing actuation forces to raise the valve actuation potential. Both actuate to open and actuate to close valves have been demonstrated, and integrated into a microfluidic platform, and demonstrated fluidic control using electrostatic valves.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

“A System for Automatically Maintaining Pressure in a Commercial Truck Tire”

Under-inflated tires significantly reduce a vehicle’s fuel efficiency by increasing rolling resistance (drag force). The Air Maintenance Technology (“AMT”) system developed through this project replenishes lost air and maintains optimal tire cavity pressure whenever the tire is rolling in service, thus improving overall fuel economy by reducing the tire’s rolling resistance. The system consists of an inlet air filter, an air pump driven by tire deformation during rotation, and a pressure regulating device. Pressurized air in the tire cavity naturally escapes by diffusion through the tire and wheel, leaks in tire seating, and through the filler valve and its seating. As a result, tires require constant maintenance to replenish lost air. Since manual tire inflation maintenance is both labor intensive and time consuming, it is frequently overlooked or ignored. By automating the maintenance of optimal tire pressure, the tire’s contribution to the vehicle’s overall fuel economy can be maximized. The work was divided into three phases. The objectives of Phase 1, Planning and Initial Design, resulted in an effective project plan and to create a baseline design. The objectives for Phase 2, Design and Process Optimization, were: to identify finalized design for the pump, regulator and filter components; identify a process to build prototype tires; assemble prototype tires; test prototype tires and document results. The objectives of Phase 3, Design Release and Industrialization, were to finalize system tire assembly, perform release testing and industrialize the assembly process.

42 ENGINEERING↗