Hydrostatic sea level changes
Inverted barometer effects and steric changes effects on hydrostatic response of ocean
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Inverted barometer effects and steric changes effects on hydrostatic response of ocean
Absolute cosmic ray ionization measurements in upper and lower atmosphere
A relatively simple method for measuring with high sensitivity the rate of stopped negative muons is described. A process in which Ar-37 is obtained from K-39 in connection with the stopping of a negative muon was used in the experiments. The Ar-37 activity can be measured in small proportional counters with extremely low backgrounds. It is possible to remove Ar-37 from potassium acetate powder at room temperature with almost 100 per cent efficiency merely by trapping the gas from the storage container with a charcoal trap at the liquid nitrogen temperature.
An empirical separation and side load model to obtain applied aerodynamic loads has been developed based on data obtained from full-scale J-2S (265K-pound-thrust engine with an area ratio of 40:1) engine and model testing. Experimental data include visual observations of the separation patterns that show the dynamic nature of the separation phenomenon. Comparisons between measured and applied side loads are made. Correlations relating the separation location to the applied side loads and the methods used to determine the separation location are given.
Explore the source record for details and available documents.
The primary experiment on the Geodynamics Experimental Ocean Satellite-3 (GEOS-3) is the radar altimeter. This experiment's major objective is to demonstrate the utility of measuring the geometry of the ocean surface, i.e. the geoid. Results obtained from this experiment so far indicate that the planned objectives of measuring the topography of the ocean surface with an absolute accuracy of + or - 5 meters can be met and perhaps exceeded. The GEOS-3 satellite altimeter measurements have an instrument precision in the range of + or - 25 cm to + or - 50 cm when the altimeter is operating in the short pulse mode.
Explore the source record for details and available documents.
Experimental evidence is reported for fixed distances (0, 1.0, 2.5 and 4.0 m) from the shower centers and for core flattening. The cores become flatter, on average, as the shower size (primary energy) increases. With improved statistics on 4192 cores, the previous results are exactly confirmed.
Simulation predictions for the Leeds 35 sq m horizontal discharge chamber array for proton primaries with a approx. E sup 2.7 spectrum extrapolated from balloon data to 10 to the 16th power eV give power law rho (r)-spectra with constant slope approx. -2 consistent with the experimental data up to the point at which they steepen but overshooting them at higher densities, and at high shower sizes predicted cores which are significantly steeper than those observed. Further comparisons with results for heavy nuclei primaries (up to A = 56) point to the inadequacy of changes in primary composition to account for the observed density spectra and core flattening, and the shower size spectrum together, and point, therefore, to the failure of the scaling interaction model at approx. 10 to the 15th power eV primary energy.
The E594 neutrino detector has been used to study the lateral distribution of muons of energy 3 GeV near shower cores. The detector consists of a 340 ton fine grain calorimeter with 400,000 cells of flash chamber and dimensions of 3.7 m x 20 m x 3.7 m (height). The average density in the calorimeter is 1.4 gm/sq cm, and the average Z is 21. The detector was triggered by four 0.6 sq m scintillators placed immediately on the top of the calorimeter. The trigger required at least two of these four counters. The accompanying extensive air showers (EAS) was sampled by 14 scintillation counters located up to 15 m from the calorimeter. Several off line cuts have been applied to the data. Demanding five particles in at least two of the trigger detectors, a total of 20 particles in all of them together, and an arrival angle for the shower 450 deg reduced the data sample to 11053 events. Of these in 4869 cases, a computer algorithm found at least three muons in the calorimeter.
Time coincident voltage pulses in the two closely space (1.6m) plastic scintillators were recorded. Most of the recorded events are expeted to be due to electrons in cosmic ray showers whose core fall at some distance from the detectors. This result is confirmed from a measurement of the frequency distribution of the recorded density ratios of the two scintillators.
The arrival time distributions of muons with energies above 1.0GeV and 0.5GeV have been measured in the Akeno air-shower array to study the longitudinal development of muons in air showers with primary energies in the range 10 to the 17th power to 10 to the 18th power ev. The average rise times of muons with energies above 1.0GeV at large core distances are consistent with those expected from very high multiplicity models and, on the contrary, with those expected from the low multiplicity models at small core distances. This implies that the longitudinal development at atmospheric depth smaller than 500 cm square is very fast and that at larger atmospheric depths is rather slow.
The discrepancy between the muon charge ratio observed at low energies and that calculated using pp data is removed by including nuclear target effects. Calculations at high energies show that the primary iron spectrum is expected to change slope from 2 to 2.2 to 2.4 to 2.5 for energies approx. 4 x 10 to the 3 GeV/nucleon if scaling features continue to the highest energies.
Energetic delayed hadrons in air showers with electron sizes in the range 10 to the 6th power to 10 to the 9th power were studied by observing the delayed bursts produced in the shield of nine square meter scintillation detectors in the Chacaltaya air-shower array. The frequency of such delayed burst is presented as a function of electron size, core distance and sec theta.
To contribute to a better understanding of the electromagnetic bias in radar altimetry, a series of experiments was conducted using a focused beam radar set at 13.5-GHz frequency. For pure wind wave fields, the authors found the bias to be a quadratic function of each of the commonly used parameters, namely, the significant wave height, the wind speed, the water elevation skewness, and significant slope. The bias divided by the significant wave height is a linear function of these parameters. The coefficients in bias representation as a function of either the significant wave height or the wind speed are significantly different from values obtained in field experiments. This led to the conclusion that none of the latter parameters can be taken solely to account for all observed bias variations. Instead, dimensionless parameters such as the wave skewness or a dimensionless wave height are shown to be more appropriate.
Frechet kernels for the RSL data in Hunson Bay are computed to determine the detailed depth-dependent sensitivity of the data to variations in a viscosity profile which is consistent with the past inferences. The RSL data provide a robust constraint on the average viscosity in the top half of the lower mantle only (the average must be near 10 exp 21 Pa s). The data admit models whose average viscosity in the deep mantle (below 1800 km depth) and in the upper mantle can differ significantly from the value (near 10 exp 21 Pa s) estimated for the top half of the lower mantle. The total variation in the viscosity from the surface to the CMB can exceed an order of magnitude or more and still satisfy the constraint provided by the Hudson Bay RSL data set. The necessity of invoking an isoviscous mantle model in previous studies is a consequence of the limited class of viscosity model solutions employed in those studies.
Explore the source record for details and available documents.
Explore the source record for details and available documents.