Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Method for error correction in scanning probe microscopy

Disclosed here is a scanning probe microscope system and method for operating the same for producing scanning probe microscope images at fast scan rates and reducing oscillation artifacts. In some embodiments, an inverse consistent image registration method is used to align forward and backward scan traces for each line of the scanning microscope image. In some embodiments, the aligned forward and backward scan traces are combined using a weighting factor favoring the scan trace with higher smoothness. In some embodiments, the scanning probe microscope image is a potentiometry map and a method is provided to extract from the potentiometry map a conductivity map.

47 OTHER INSTRUMENTATION↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, and B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector

Purpose: The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. Methods: A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve either a uniform dose or a 2-level “step-dose” pattern. Results: With 6% refractive index mismatching, a circular field of view of 85% of the diameter of a cylindrical sample can be reconstructed accurately. Reconstructed images of the test solution phantom were uniform (within 3%) inside this radius. However, the dose responses of the PRESAGE® samples were not spatially uniform, with variations of at least 5% in sensitivity. The variation appears as a “cupping” artifact with less sensitivity in the middle than at the periphery of the PRESAGE® cylinder. Polarization effects were also detected for these samples. Conclusions: The fiducial-based ray path measurement scheme, coupled with an iterative reconstruction algorithm, enabled optical CT scanning of PRESAGE® dosimeters immersed in mismatched refractive index solutions. However, improvements to PRESAGE® dose response uniformity are required.

60 APPLIED LIFE SCIENCES↗

STARscan: Spatial Targeting and Alignment Rig for Scanning

The Spatial Targeting and Alignment Rig for Scanning (STARScan) is a 3D photogrammetry system developed at NASA Ames Research Center to address bottlenecks in pre/post-test scanning of arcjet test articles. It reduces scan time from 15 minutes with handheld laser scanners to under 2 minutes, while maintaining high accuracy (±0.2-0.5 mm). STARScan integrates an array of cameras, a 3D-printed rack, turntable, and LED light panels, all controlled via a user-friendly graphical user interface (GUI). The system offers tools for scan visualization, mesh analysis, and data export, automating tasks such as alignment of pre/post-test scans, material recession measurements, surface roughness assessment, and curvature analysis. By integrating scanning, imaging, and post-processing into one application, STARScan significantly improves efficiency in scanning and analyzing arcjet test samples.

Ablation↗

High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method

High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation↗

Workhorse minimally empirical dispersion-corrected density functional with tests for weakly bound systems: r 2 SCAN + rVV 10

SCAN+rVV10 has been demonstrated to be a versatile van der Waals (vdW) density functional that delivers good predictions of both energetic and structural properties for many types of bonding. Recently, the r 2 SCAN functional was devised as a revised form of SCAN with improved numerical stability. In this work, we refit the rVV10 functional to optimize the r 2 SCAN+rVV10 vdW density functional and test its performance for molecular interactions and layered materials. Our molecular tests demonstrate that r 2 SCAN+rVV10 outperforms its predecessor SCAN+rVV10 in both efficiency (numerical stability) and accuracy. This good performance is also found in lattice-constant predictions. In comparison with benchmark results from higher-level theories or experiments, r 2 SCAN+rVV10 yields excellent interlayer binding energies and phonon dispersions for layered materials.

36 MATERIALS SCIENCE↗

Evaluation of hybrid depth scanning for carbon-ion radiotherapy

Purpose: In radiotherapy with a scanned carbon-ion beam, its Bragg peak is shifted along the depth direction either by inserting the range shifter plates or by changing the beam-extraction energy of a synchrotron. In the former technique (range shifter scanning: RS), the range shifter plates broaden the beam size and produce secondary fragments through nuclear reactions. In the latter technique (active-energy scanning: ES), it may take several seconds to change the beam energy depending on the synchrotron operation cycle, leading to a long treatment time. The authors propose a hybrid depth scan technique (hybrid scanning: HS), where several beam energies are used in conjunction with the range shifter plates for finer range shift. In this study, HS is evaluated from the viewpoints of dose distribution and treatment time. Methods: Assuming realistic accelerator and beam-delivery systems, the authors performed computer simulations using GEANT4 Monte Carlo code for beam modeling and a treatment planning system to evaluate HS. Three target volumes with the same dimensions of 60 x 60 x 60 mm{sup 3} were generated at depths of 45, 85, and 125 mm in water phantom, and uniform clinical dose was planned for these targets. The sizes of lateral dose falloff and the peak to plateau ratio defined as the ratio of the clinical dose averaged over the target to the clinical dose at the entrance as well as the treatment time were compared among the three depth scan techniques. Results: The sizes of lateral dose falloffs at the center of SOBP are 11.4, 8.5, and 5.9 mm for the three targets in RS, while they are 5.7, 4.8, and 4.6 mm in ES and 6.6, 5.7, and 5.0 mm in HS, respectively. The peak to plateau ratios are 1.39, 1.96, and 2.15 in RS, while they are 1.48, 2.04, and 2.19 in ES and 1.47, 2.03, and 2.18 in HS, respectively. The treatment times are 128.7, 128.6, and 128.6 s in ES, while they are 61.2, 54.6, and 47.8 s in RS and 43.2, 44.1, and 44.7 s in HS, respectively. The multiple scattering and the nuclear reaction by range shifter degraded the beam qualities such as lateral dose falloff and peak to plateau ratio, which was especially pronounced for the shallow target in RS. The depth scan timing was limited by accelerator cycle in ES. That increased the treatment time by a few times. Conclusions: This study revealed that HS can provide dose distributions with steeper lateral dose falloffs and higher peak to plateau ratio comparing to RS and comparable to ES. In addition, the treatment time can be considerably reduced in HS compared to ES.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking of a treatment planning system for spot scanning proton therapy: Comparison and analysis of robustness to setup errors of photon IMRT and proton SFUD treatment plans of base of skull meningioma

Purpose: Base of skull meningioma can be treated with both intensity modulated radiation therapy (IMRT) and spot scanned proton therapy (PT). One of the main benefits of PT is better sparing of organs at risk, but due to the physical and dosimetric characteristics of protons, spot scanned PT can be more sensitive to the uncertainties encountered in the treatment process compared with photon treatment. Therefore, robustness analysis should be part of a comprehensive comparison between these two treatment methods in order to quantify and understand the sensitivity of the treatment techniques to uncertainties. The aim of this work was to benchmark a spot scanning treatment planning system for planning of base of skull meningioma and to compare the created plans and analyze their robustness to setup errors against the IMRT technique. Methods: Plans were produced for three base of skull meningioma cases: IMRT planned with a commercial TPS [Monaco (Elekta AB, Sweden)]; single field uniform dose (SFUD) spot scanning PT produced with an in-house TPS (PSI-plan); and SFUD spot scanning PT plan created with a commercial TPS [XiO (Elekta AB, Sweden)]. A tool for evaluating robustness to random setup errors was created and, for each plan, both a dosimetric evaluation and a robustness analysis to setup errors were performed. Results: It was possible to create clinically acceptable treatment plans for spot scanning proton therapy of meningioma with a commercially available TPS. However, since each treatment planning system uses different methods, this comparison showed different dosimetric results as well as different sensitivities to setup uncertainties. The results confirmed the necessity of an analysis tool for assessing plan robustness to provide a fair comparison of photon and proton plans. Conclusions: Robustness analysis is a critical part of plan evaluation when comparing IMRT plans with spot scanned proton therapy plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye award; Disclosure/Conflict of interest: Raymond H. Mak: Stock ownership: Celgene, Inc. Consulting: Boehringer-Ingelheim, Inc.

60 APPLIED LIFE SCIENCES↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗

SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CT technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.

60 APPLIED LIFE SCIENCES↗

SU-F-R-40: Robustness Test of Computed Tomography Textures of Lung Tissues to Varying Scanning Protocols Using a Realistic Phantom Environment

Purpose: The reliability of computed tomography (CT) textures is an important element of radiomics analysis. This study investigates the dependency of lung CT textures on different breathing phases and changes in CT image acquisition protocols in a realistic phantom setting. Methods: We investigated 11 CT texture features for radiation-induced lung disease from 3 categories (first-order, grey level co-ocurrence matrix (GLCM), and Law’s filter). A biomechanical swine lung phantom was scanned at two breathing phases (inhale/exhale) and two scanning protocols set for PET/CT and diagnostic CT scanning. Lung volumes acquired from the CT images were divided into 2-dimensional sub-regions with a grid spacing of 31 mm. The distribution of the evaluated texture features from these sub-regions were compared between the two scanning protocols and two breathing phases. The significance of each factor on feature values were tested at 95% significance level using analysis of covariance (ANCOVA) model with interaction terms included. Robustness of a feature to a scanning factor was defined as non-significant dependence on the factor. Results: Three GLCM textures (variance, sum entropy, difference entropy) were robust to breathing changes. Two GLCM (variance, sum entropy) and 3 Law’s filter textures (S5L5, E5L5, W5L5) were robust to scanner changes. Moreover, the two GLCM textures (variance, sum entropy) were consistent across all 4 scanning conditions. First-order features, especially Hounsfield unit intensity features, presented the most drastic variation up to 39%. Conclusion: Amongst the studied features, GLCM and Law’s filter texture features were more robust than first-order features. However, the majority of the features were modified by either breathing phase or scanner changes, suggesting a need for calibration when retrospectively comparing scans obtained at different conditions. Further investigation is necessary to identify the sensitivity of individual image acquisition parameters.

60 APPLIED LIFE SCIENCES↗