Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Equilibrium shape and location of a liquid drop acoustically positioned in a resonant rectangular chamber

The effect of a standing wave field in a rectangular chamber on the shape and location of an acoustically positioned drop or bubble is calculated. The sample deformation and equilibrium position are obtained from an analysis of the spherical harmonic projections of the total surface stress tensor. The method of calculation relies on the assumed condition that the sample is only slightly distorted from a spherical form. The equilibrium location of a levitated drop is combined with a formula introduced by Hasegawa (1979) to calcualte the ka dependence of the radiation force function. The present theory is valid for large as well as small ka values. Calculations in the small ka limit agree with previous theories and experimental results. Examples are presented for nonplane-wave modes as well as plane-wave rectangular modes.

Jackson, H. W.↗

An Open Port Sampling Interface for Liquid Introduction Atmospheric Pressure Ionization Mass Spectrometry

RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creating a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-kilovolt coherent electron diffractive imaging instrument based on a single-atom electron source

In this work, a transmission-type, low-kilovolt coherent electron diffractive imaging instrument was constructed. It comprised a single-atom field emitter, a triple-element electrostatic lens, a sample holder, and a retractable delay line detector to record the diffraction patterns at different positions behind the sample. It was designed to image materials thinner than 3 nm. The authors analyzed the asymmetric triple-element electrostatic lens for focusing the electron beams and achieved a focused beam spot of 87 nm on the sample plane at the electron energy of 2 kV. High-angle coherent diffraction patterns of a suspended graphene sample corresponding to (0.62 Å){sup −1} were recorded. This work demonstrated the potential of coherent diffractive imaging of thin two-dimensional materials, biological molecules, and nano-objects at a voltage between 1 and 10 kV. The ultimate goal of this instrument is to achieve atomic resolution of these materials with high contrast and little radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sample 67215: An Anomalous Ferroan Anorthosite

Sample 67215c is a ferroan anorthosite clast with an age of 4.4 Ga and a positive Nd. The sample has a well preserved microcumulate texture. Relatively rapid cooling rates coupled with preserved pigeonite are consistent with a shallow (<1 km) origin. Additional information is contained in the original extended abstract.

McCallum, I. S.↗

Self-Organized Criticality and Phase Problem in Magnetoaocustic Emission Burst in Ferromagnets

Two types of ferromagnets, pure iron and steel with varying geometry and microstructural properties, were prepared for the present study of magnetoacoustic emission (MAE). The purpose was to separate the effects of structural property variations from changes caused by differences in the sample geometry. The position and shape of the leading MAE sub-burst and its variation among the samples are explained by magnetic anisotropy and the results of numerical simulations which utilized the concept of self-organized criticality (SOC). The amplitude and duration of the second sub-burst, which previously was thought to occur as a result of a complicated interaction between non-180 deg domain walls and lattice defects, can easily be explained by the results of our simulation.

Namkung, M.↗

An instrument for 3D x-ray nano-imaging

We present an instrument dedicated to 3D scanning x-ray microscopy, allowing a sample to be precisely scanned through a beam while the angle of x-ray incidence can be changed. The position of the sample is controlled with respect to the beam-defining optics by laser interferometry. The instrument achieves a position stability better than 10 nm standard deviation. The instrument performance is assessed using scanning x-ray diffraction microscopy and we demonstrate a resolution of 18 nm in 2D imaging of a lithographic test pattern while the beam was defined by a pinhole of 3 {mu}m in diameter. In 3D on a test object of copper interconnects of a microprocessor, a resolution of 53 nm is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV-SIMS TOF Imaging of Organic Tissue with Continuous Primary Beam

MeV-SIMS is an emerging mass spectrometry imaging method, which utilizes fast, heavy ions to desorb secondary molecules. High yields and low fragmentation rates of large molecules, associated with the electronic sputtering process, make it particularly useful in biomedical research, where insight into distribution of organic molecules is needed. Since the implementation of MeV-SIMS in to the micro-beam line at the tandem accelerator of Jožef Stefan Institute, MeV-SIMS provided some valuable observations on the distribution of biomolecules in plant tissue, as discussed by Jenčič et al. (Nucl. Inst. Methods Phys. Res. B. 371, 205–210, 2016; Nucl. Inst. Methods Phys. Res. B. 404, 140–145, 2017). However, limited focusing ability of the chlorine ion beam only allowed imaging at the tissue level. In order to surpass shortcomings of the existing method, we introduced a new approach, where we employ a continuous, low-current primary beam. In this mode, we bombard thin samples with a steady chlorine ion flux of approx. 5000 ions/s. After desorbing molecules, chlorine ions penetrate through the thinly cut sample and trigger the time-of-flight “start” signal on a continuous electron multiplier detector, positioned behind the sample. Such bombardment is more effective than previously used pulsing-beam mode, which demanded several orders of magnitude higher primary ion beam currents. Sub-micrometer focusing of low-current primary ion beam allows imaging of biological tissue on a subcellular scale. Simultaneously, new time-of-flight acquisition approach also improves mass resolution by a factor of 5. Within the article, we compare the performance of both methods and demonstrate the application of continuous mode on biological tissue. We also describe the thin sample preparation protocol, necessary for measurements with low primary ion currents. .

74 ATOMIC AND MOLECULAR PHYSICS↗

The x-ray source application test cassette for radiation exposures at the OMEGA laser

We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5{sup Double-Prime }) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Imaging of Advanced Transportation Technologies

Unlike X-rays, neutrons are very sensitive to light elements such as hydrogen (H) atoms and can penetrate through thick layers of metals (Figure 1a). These two properties suggest neutrons are well suited to probe engine parts such as diesel particulate filters, exhaust gas recirculation coolers, fuel injectors, oil in engines, oil residues in filters, batteries, advanced materials, etc. Neutron imaging is based on the interactions of a sample with a neutron beam. The interactions are dependent on sample thickness/density and elemental make-up and result in absorption and scattering of neutrons within the sample. A two-dimensional position-sensitive detector placed behind the sample can measure the transmitted neutron flux (Figure 1b). When combined with a high-precision (~1/100 of a degree) rotational stage, it is possible to perform computed tomography (CT) scans and thus generate 3-dimensional images of working fluids inside real devices. Samples can be analyzed at one position or a complete reconstruction can provide a cross-section of the entire sample at a resolution of the detector; the detector resolution is currently at ~50–80 microns (at the detector).

47 OTHER INSTRUMENTATION↗

Chip-based device for parallel sorting, amplification, detection, and identification of nucleic acid subsequences

An apparatus for chip-based sorting, amplification, detection, and identification of a sample having a planar substrate. The planar substrate is divided into cells. The cells are arranged on the planar substrate in rows and columns. Electrodes are located in the cells. A micro-reactor maker produces micro-reactors containing the sample. The micro-reactor maker is positioned to deliver the micro-reactors to the planar substrate. A microprocessor is connected to the electrodes for manipulating the micro-reactors on the planar substrate. A detector is positioned to interrogate the sample contained in the micro-reactors.

47 OTHER INSTRUMENTATION↗

Analysis of sensitivity and rapid hybridization of a multiplexed Microbial Detection Microarray

Microarrays have proven to be useful in rapid detection of many viruses and bacteria. Pathogen detection microarrays have been used to diagnose viral and bacterial infections in clinical samples and to evaluate the safety of biological drug materials. A multiplexed version of the Lawrence Livermore Microbial Detection Array (LLMDA) was developed and evaluated with minimum detectable concentrations for pure unamplified DNA viruses, along with mixtures of viral and bacterial DNA subjected to different whole genome amplification protocols. In addition the performance of the array was tested when hybridization time was reduced from 17 h to 1 h. The LLMDA was able to detect unamplified vaccinia virus DNA at a concentration of 14 fM, or 100,000 genome copies in 12 μL of sample. With amplification, positive identification was made with only 100 genome copies of input material. When tested against human stool samples from patients with acute gastroenteritis, the microarray detected common gastroenteritis viral and bacterial infections such as rotavirus and E. coli. Accurate detection was found but with a 4-fold drop in sensitivity for a 1 h compared to a 17 h hybridization. The array detected 2 ng (equivalent concentration of 15.6 fM) of labeled DNA from a virus with 1 h hybridization without any amplification, and was able to identify the components of a mixture of viruses and bacteria at species and in some cases strain level resolution. Sensitivity improved by three orders of magnitude with random whole genome amplification prior to hybridization; for instance, the array detected a DNA virus with only 20 fg or 100 genome copies as input. This multiplexed microarray is an efficient tool to analyze clinical and environmental samples for the presence of multiple viral and bacterial pathogens rapidly.

59 BASIC BIOLOGICAL SCIENCES↗

A Comprehensive Characterization of Microorganisms and Allergens in Spacecraft Environment

The determination of risk from infectious disease during long-duration missions is composed of several factors including the concentration and the characteristics of the infectious agent. Thus, a thorough knowledge of the microorganisms aboard spacecraft is essential in mitigating infectious disease risk to the crew. While stringent steps are taken to minimize the transfer of potential pathogens to spacecraft, several medically significant organisms have been isolated from both the Mir and International Space Station (ISS). Historically, the method for isolation and identification of microorganisms from spacecraft environmental samples depended upon their growth on culture media. Unfortunately, only a fraction of the organisms may grow on a culture medium, potentially omitting those microorganisms whose nutritional and physical requirements for growth are not met. Thus, several pathogens may not have been detected, such as Legionella pneumophila, the etiological agent of Legionnaire s disease. We hypothesize that environmental analysis using non-culture-based technologies will reveal microorganisms, allergens, and microbial toxins not previously reported in spacecraft, allowing for a more complete health assessment. The development of techniques for this flight experiment, operationally named SWAB, has already provided advances in NASA laboratory processes and beneficial information toward human health risk assessment. The translation of 16S ribosomal DNA sequencing for the identification of bacteria from the SWAB experiment to nominal operations has increased bacterial speciation of environmental isolates from previous flights three fold compared to previous conventional methodology. The incorporation of molecular-based DNA fingerprinting using repetitive sequence-based polymerase chain reaction (rep-PCR) into the capabilities of the laboratory has provided a methodology to track microorganisms between crewmembers and their environment. Both 16S ribosomal DNA identification and bacterial fingerprinting have improved NASA s capability to better understand spacecraft environments and determine the source of contamination events. Preflight sampling has been completed for air, surface, and water samples. In-flight sample collection has been completed for a total of 8 air and surface sample collection sessions. In-flight hardware has performed well and the surface sampling device received positive feedback from the crew for its ease of use. While processing and analysis continue for these samples, early results have begun to provide information on the spacecraft environment. Using a method called Denaturing Gradient Gel Electrophoresis (DGGE), several air and samples were evaluated to determine the types of organisms that were present. Using only molecular techniques, DGGE does not depend on any microbial growth on culture media, allowing a more comprehensive assessment of the spacecraft interior. Preliminary results have identified several microorganisms that would not have been isolated using current technology, though none of these organisms would be considered medically significant. Interestingly, the isolation of Gram negative organisms is greater using DGGE than conventional media based isolation. The cause of this finding is unclear, though it may be the result of the technique s ability to isolate both viable and non-viable bacteria. The next phase of the SWAB sample analysis is the use of quantitative polymerase chain reaction (QPCR) to look for specific medically significant organisms. While not as broad as DGGE, QPCR is much more sensitive and may reveal findings that were not seen during the initial evaluation. Together, this information will lead toward an accurate microbial risk assessment to help set flight requirements to protect the safety, health, and performance of the crew.

Castro, V.A.↗

Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) in Support of Plant-Growth Systems

As the National Aeronautics and Space Association (NASA) begins to pursue long-duration space flights, they will need to be able to provide astronauts with a nutritious and reliable food source. To meet the administration’s goal of traveling to the Moon and Mars, astronauts will need to begin to grow their own food in space. To protect their food source, extensive monitoring will occur to test for the effects of a space flight environment (e.g., radiation) as well as for early pathogen and disease detection. Genomic sequencing allows for both concerns to be tested on a regular basis. However, NASA’s current sequencer is unable to process plant tissues. Therefore, a novel method for plant DNA extraction using microneedle (MN) patches that will be able to feed into NASA’s existing system, but also require minimal human input is proposed. To support this, the design was broken down into four components (1) MN patch fabrication (2) MN patch extraction, (3) automated sampling motion control, and (4) a processing module. The MN patch is fabricated using a custom mold with conically shaped needles. The mold is filled with Polyvinyl alcohol (PVA) solution and placed in a vacuum desiccator. The mold is left in the vacuum overnight until the patch is dry and ready for use. The protocol was tested with varying pressures, drying times, volume amounts, and preparation methods to determine if highquality needles can be produced. A MN is a method of DNA extraction where the patch is applied to a leaf, the needles penetrate the leaf, breaking the rigid plant cell wall to isolate the DNA. A protocol for this method of extraction was tested to ensure the patch could produce the needed yield and purity. The tests varied by the number of patches, number of applications, and plant type. To automate the MN extraction method, motion control will utilize two separate axis tables which move in the x and y directions. The y-axis table will have an end effector that fits a MN patch and will have the ability to apply the patch to the leaf sample. This end effector will also act as a lid for a downstream processing module. The other axis will position the leaf sample and processing container so that the patch can be applied accurately. The Joint Comprehensive Sequencing System (JCSS) module integrates all the components together. The output of this module feeds into the NASA Charged Information-Storage Polymer Preparation System (CHIPPS) for genomic sequencing. The extraction module operates using a series of syringes and tubing to pump the varying reagents needed for the extraction protocol. The results of the study proved that MN patches are a viable method of DNA extraction. While fabrication of high-quality needles was unsuccessful, the protocol was able to be further developed using centrifugation. The integrated design between the motion control and the JCSS enabled the potential for automation with a complete conceptual design and prototype. Future research and development for this study would include (1) further testing for fabrication (2) expanding the range of plant species compatible with the MN patch, and (3) building a working prototype for the integrated system.

Peter Ling↗

Geometric correction process for the Landsat-4 Thematic Mapper

The processing approaches which form the basis of the Landsat-4 Thematic Mapper (TM) geometric correction system are summarized. The correction is accomplished in two phases. In the first phase, correction data are generated. The spacecraft position, TM frame attitude, TM scanning mirror position, and detector sampling are found as a function of time through a combination of flight segment measurements, ground segment modeling, and control point information. The data, along with the earth position and geoid model, are used to determine the earth location for each TM image sample. Then, using map projections, correction data can be generated which define the location of each TM image sample on the output coordinate system. In the second phase, the correction data are used to resample TM detector samples onto the output coordinate system.

Beyer, E. P.↗

Cytological Sampling Versus Forceps Biopsy During Percutaneous Transhepatic Biliary Drainage and Analysis of Factors Predicting Success

Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity was 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Downhole Elemental Analysis with LIBS

In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a vertical stage; a second actuator at the top of the downhole probe allows radial scanning of the borehole. Analysis of iron and titanium in lunar simulant with LIBS was performed in air using the method of standard addition. The results for lunar simulant NU-LHT-2M show a value for the concentration of iron ranging between 2.29% and 3.05% depending on the atomic line selected. The accepted value for the sample analyzed is 2.83%, showing the capability for the system in development to provide qualitative and semi-quantitative analysis in real-time.

Moreschini, Paolo↗

Thermophysical analysis of II-VI semiconductors by PPE calorimetry and lock-in thermography

An accurate determination of thermophysical properties such as thermal diffusivity, thermal effusivity and thermal conductivity is extremely important for characterization and quality assurance of semiconductors. Thermal diffusivity and effusivity of some binary semiconductors have been investigated. Two experimental techniques were used: a contact technique (PPE calorimetry) and a non contact technique (lock-in thermography). When working with PPE, in the back (BPPE) configuration and in the thermally thick regim of the pyroelectric sensor, we can get the thermal diffusivity of the sample by performing a scanning of the excitation frequency of radiation. Thermal effusivity is obtained in front configuration (sensor directly irradiated and sample in back position) by performing a thickness scan of a coupling fluid. By using the lock-in thermography technique, the thermal diffusivity of the sample is obtained from the phase image. The results obtained by the two techniques are in good agreement. Nevertheless, for the determination of thermal diffusivity, lock-in thermography is preferred.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circular RNA expression and circPTPRM promotes proliferation and migration in hepatocellular carcinoma

Circular RNAs (circRNAs) play a critical role during hepatocellular carcinoma (HCC) development. CircRNA PTPRM (circPTPRM) has not been reported to cause disease and its role in HCC is unclear. This study explored circRNA expression and the function of circPTPRM in HCC. RNA sequencing (RNA-seq) was performed on 3 randomly selected pairs of HCC tissues and their corresponding adjacent non-tumor tissues. Three differentially expressed circRNAs, circPTPRM, circSMAD2 and circPTBP3 were selected and verified by real-time quantitative reverse transcription-polymerase chain reactions in 30 pairs of tissue samples, In vitro cultured hepatoma cells, and normal liver cells. Clinical data analysis was performed to select target circRNAs. Anti-target circRNA siRNAs were transfected into hepatoma cell lines, and the biological behavior of hepatoma cells following silencing of the target circRNA were detected by cell proliferation, plate cloning, and transwell assays. There were 86 differentially expressed circRNAs from RNA-seq, of which 53 were significantly upregulated and 33 were significantly downregulated in HCC. CircPTPRM expression was significantly upregulated in HCC tissue (p = 0.023) based on the analysis of 30 paired samples. CircPTPRM expression positively correlated with HCC recurrence and metastasis (p = 0.039). CircPTPRM silencing reduced HCC cell proliferation, migration and invasion. CircRNAs were differentially expressed in HCC samples. CircPTPRM was significantly upregulated in HCC and may function during the tumorigenesis and metastasis of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗