Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resource Assessments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Survey and Assessment of the Ocean Renewable Energy Resources in the US Gulf of Mexico

This study was conducted by the National Renewable Energy Laboratory (NREL) and funded by the Bureau of Ocean Energy Management (BOEM). It provides a comprehensive feasibility assessment of multiple offshore renewable energy technologies in the Gulf of Mexico (GoM) to inform BOEM's strategic plans related to possible Outer Continental Shelf alternative energy leasing activities in the GoM. In coordination with Gulf Coast states, the study includes some information on offshore renewable energy potential in state waters for future energy planning. The goal of the study is to survey potential offshore renewable energy sources in the GoM and quantify their feasibility relating to resource adequacy, technology maturity, and the potential for competitive cost. The study provides a review of available technologies and concepts for generating offshore renewable energy, including a high-level assessment of the current state of each technology and its potential for future advances. It provides a breakdown of resource capacity for each renewable energy technology and a recommendation that offshore wind be pursued for future study as the most promising technology. The renewable technologies that were considered include offshore wind, wave energy, tidal energy, ocean current energy, offshore solar energy, ocean thermal energy conversion (OTEC), cold water source cooling, and hydrogen (as a storage medium to utilize existing pipeline infrastructure). The resource capacity for each of these renewable energy sources was quantified for both the gross resource capacity potential (gross resource) and the technical resource capacity potential (technical resource) using the methodology described in an earlier NREL report. Many of these sources are very immature from a commercial perspective, which makes some of the comparisons difficult. In many cases, new methods were developed to estimate nominal power density for each technology type, which were necessary to convert the resource areas into deployable gross and technical resource capacity potentials.

17 WIND ENERGY↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Screening Assessment of Prospective CO 2 Storage Resource Potential in Saline Carbonate Systems, Central North Dakota Region

Conference presentation at 2023 Rocky Mountain Section-American Association of Petroleum Geologists (RMS-AAPG) Annual Meeting, Bismarck, ND, June 4–6, 2023. As part of the U.S. Department of Energy-funded North Dakota CarbonSAFE Phase III effort, a screening-level assessment was conducted over central North Dakota, including McLean, Mercer, and Morton Counties, to determine if viable CO 2 storage resource potential exists within carbonate saline reservoirs. Published literature and data from 173 wells were used in the study. The study focused on identifying carbonate saline reservoirs and suitable confining zones for CO 2 storage, with emphasis on three key questions: 1) are the carbonate saline reservoirs viable for CO 2 storage? 2) what is their range of storage resource potential? and 3) what are the main elements driving uncertainty and risk of potential capacity and containment?

20 FOSSIL-FUELED POWER PLANTS↗

Module 5: End Use Assessment - Lesson 5.1: Introduction to End Use Assessment [Slides]

End use assessment is the process of performing a technical evaluation of the stated end use in relation to the requested commodity and the activities of the end user. An end use assessment requires sufficiently detailed information on the procurement request, commodity technical specifications, end use conditions, end user business activities, industry norms and trends, and WMD or delivery system applications of stated end use. Reviewers should be aware of red flags related to end use assessment. Use best practices when writing an end use assessment. Be familiar with technical resources for end use assessments.

99 GENERAL AND MISCELLANEOUS↗

An Architectural Survey of the U12G Tunnel Historic District, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to demolish six buildings and three storage areas located at the U12g Tunnel portal area in Area 12 of the Nevada National Security Site (NNSS). The buildings are 12-358 (Signal Vault); 12-201800 (Storage Quonset Hut); 12-202555 (Walker Shack); 12-868 (Pipe Assembly); 12-B100933 (Electrical Shop); 12-B100944 (Conference Room); and Storage Area 1; Storage Area 2; and Storage Area 3. The buildings and storage areas were selected for demolition as part of the DOE’s Real Property Efficiency Plan to reduce the footprint of unused and non-operational facilities on the NNSS. They are all vacant and have no proposed uses for current or upcoming NNSS missions. Demolition activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. Identification efforts began with resources proposed for demolition in federal Fiscal Year (FY) 23. Four buildings were proposed to be demolished in FY23 (12-358, 12-868, 12-201800, and 12-202555). These buildings and the U12g Tunnel Historic District (SHPO No. D444) were recorded in Identification, Evaluation, and Finding of Adverse Effect for the Proposed Demolition of Five Buildings in Area 12, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2023). Identification efforts indicated three buildings (12-358, 12-201800, and 12-868) supported nuclear testing in the U12g Tunnel. The fourth building post-dated the use of U12g Tunnel for nuclear testing activities. The report recommended that three of the four buildings (12-358, 12-201800, 12-868) and the U12g Tunnel Historic District may be eligible for the National Register of Historic Places (NRHP). The report also found that the undertaking would have an adverse effect on the three buildings and on the historic district. The Nevada State Historic Preservation Office (SHPO) concurred with the report’s findings (Reed 2023). The U12g Tunnel was determined eligible as a historic district under the Secretary of the Interior’s (SOI) Significance Criterion A, at the local level, in the context of the Cold War as an underground testing environment for the development of nuclear weapons and to assess the effects of a nuclear explosion on materials and equipment with a period of significance from 1959 to 1971. It was also determined eligible under Significance Criterion C for embodying the distinctive characters of a horizontal tunnel complex used for nuclear testing and as a significant and distinguishable entity. The three buildings were determined to be contributing elements of the district. The undertaking was expanded with the addition of two buildings and three storage areas proposed to be demolished and located within U12g Tunnel Historic District in FY24. These five resources (12-B100933, 12-B100944, and Storage Areas 1, 2, and 3) were recorded in Supplemental Identification, Evaluation, and Finding of Effect for Additional Proposed Demolition at U12g Tunnel, Area 12, Nevada national Security Site, Nye County, Nevada (Brannan et al. 2024). Identification efforts indicated that the two buildings and Storage Area 1 supported nuclear testing in the U12g Tunnel. Storage Area 1 and Storage Area 2 post-dated the nuclear testing activities at U12g Tunnel and were not recommended as contributing elements to the district. The report also found that the undertaking would have an adverse effect on the newly identified buildings and one storage area and on the historic district. The SHPO concurred that the expanded undertaking would result in adverse effects to historic properties (Reed 2025). To resolve these adverse effects, NNSA/NFO, in consultation with the SHPO, is following standard mitigation as stipulated in the 2024 Programmatic Agreement DE-GM58-22NA25554 Among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the NNSS PA). The standard mitigation measures are outlined in Appendix D of the NNSS PA. As such, this architectural survey has been prepared in accordance with Appendix D of the NNSS PA and follows the report format outlined in Appendix F. It includes a historic context that describes the district’s origin, history, and support functions, its significance in the context of nuclear testing on the NNSS, and identifies contributing and non-contributing elements within the district. The report is accompanied by Architectural Resource Assessment (ARA) forms for individual resources and a Historic District Resource Assessment (HDRA) for the U12g Tunnel Historic District. In total, this architectural report identified 32 primary resources within the district boundary. Six of the primary resources were previously identified as contributing elements. An additional 17 resources are recommended as contributing elements to the district for a total of 23 contributing elements. The other nine resources identified are recommended as non-contributing elements to the district.

12-201800↗

Empirical Assessment of Interregional Coordination to Support Resource Adequacy [Slides]

This study examines where interregional transmission could most effectively support resource adequacy in the contiguous United States. We use hourly load, renewable generation, and real-time price data from 2016–2023 for 18 planning subregions to identify periods of elevated adequacy risk, defined as the top 100 annual hours of net load and wholesale prices in each region. We then measure the temporal coincidence of these peak periods between adjacent regions and compare price patterns to assess the potential for capacity sharing. Results show that NorthernGrid West, a winter-peaking region, has low coincidence of peak net load with its summer-peaking neighbors, indicating high potential for interregional support. In contrast, regions in the Northeast have highly coincident peak periods, suggesting limited adequacy benefits from additional transmission. Price-based analysis shows peak-hour differences in the Midwest and between ERCOT and neighboring regions, indicating potential economic benefits from increased transfers. The findings provide an empirical screening of where transmission may offer the greatest reliability benefits without adding new generation capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Temperature Geothermal Geospatial Datasets: An Example from Alaska: Preprint

This project is part of a broader effort focused on geothermal heating and cooling with the purpose of demonstrating the multi-faceted value of integrating GHC/GHX into national decarbonization plans and community energy plans. Currently, there is a need to better define and evaluate low-temperature geothermal resource potential to provide the basis for supporting private sector investment. For shallow GHC/GHX fields, there is no formal compilation of subsurface characteristics shared among industry practitioners that can improve system design and operations. Alaska is specifically noted in this work, because heretofore, it has not received a similar focus in geothermal potential evaluations as the contiguous United States. The methodology consists of leveraging relevant data generate a baseline low-temperature resources (< 150 degrees C) geospatial dataset to compare and analyze information accessible to anyone trying to understand the potential of GHC/GHX and small-scale low-temperature geothermal power in Alaska (e.g., energy modelers, communities, planners, and policymakers). Importantly, this project is identifying data related to (1) the evaluation of GHC/GHX in the shallow subsurface, and (2) the evaluation of low-temperature geothermal resource availability. Additionally, data is being compiled to assess repurposing of oil and gas wells to contribute co-produced fluids toward the geothermal direct use and heating and cooling resource potential. The goal of this project is facilitating future deployment of GHC/GHX analysis and community-led programs and update the low-temperature geothermal resources assessment of Alaska. A better understanding of shallow potential for geothermal heat exchange (GHX) will improve design and operations of highly efficient GHC systems. The deployment and impact that can be achieved for low temperature geothermal resources will contribute to decarbonization goals and facilitate widespread electrification by shaving and shifting grid loads.

bottom-hole temperature↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Deliverable 6.7-Final Technical Report: Development Summary and Evaluation of the Solar Uncertainty Integrator (SUNI) Software

The Data Quality and Uncertainty Integration Project was a three-year effort to address stakeholder needs for assessing solar radiation resource data quality based on existing tools for estimating radiometer measurement uncertainties and assessing post-measurement data quality. The annual research objectives for the project addressed a logical progression of effort needed to achieve the ultimate project goal of developing the Solar Uncertainty Integrator (SUNI) software. This final technical report summarizes the development process for achieving these key research objectives and addresses the outreach and code development efforts in the final year of the project to develop a new solar irradiance data uncertainty integration software package.

14 SOLAR ENERGY↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A review of tidal energy—Resource, feedbacks, and environmental interactions

The ocean contains a variety of renewable energy resources, little of which has been exploited. Here, we review both tidal range and tidal stream energy, with a focus on the resource, feedbacks, and environmental interactions. The review covers a wide range of timescales of relevance to tidal energy, from fortnightly (spring-neap) and semi-diurnal variability, down to array, and device-scale turbulence. When simulating the regional tidal energy resource, and to assess environmental impacts, it is necessary to account for feedbacks between the tidal array and the resource itself. We critically review various methods for simulating energy extraction, from insights gained through theoretical studies of “tidal fences” in idealized channels, to realistic three-dimensional model studies with complex geometry and arrays of turbines represented by momentum sinks and additional turbulence due to the presence of rotors and support structures. We discuss how variability can be reduced by developing multiple (aggregated) sites with a consideration of the enhanced phase diversity offered by exploiting less energetic tidal currents. This leads to future research questions that have not yet been explored in depth at first-generation tidal sites in relatively sheltered channels (e.g., the interaction of waves with currents). Such enhanced understanding of real sea conditions, including the effects of wind and waves, leads to our other identified primary future research direction—reduced uncertainties in turbulence predictions, including the development of realistic models that simulate the interaction between ambient turbulence and the turbulence resulting from multiple wakes, and changes to system-wide hydrodynamics, water quality, and sedimentation.

Environmental impacts↗

Bias Characterization, Vertical Interpolation, and Horizontal Interpolation for Distributed Wind Siting Using Mesoscale Wind Resource Estimates

Much like their counterparts in utility-scale wind energy, developers of industrial, small-scale and distributed wind turbine deployments need to understand and accurately characterize the wind resource to properly assess the power generation and financial ramifications during siting and planning. National Renewable Energy Laboratory’s WIND (Wind Integration National Dataset) Toolkit (WTK) provides a best-in-class wind resource dataset generated using the Weather Research and Forecasting (WRF) model. This dataset includes parameters such as the wind speed, wind direction, and temperature at various heights, plus atmospheric stability near the surface. This data is available at 2-km spatial resolution and five-minute temporal resolution across 7 years, from 2007 to 2013 through a publicly accessible API interface. The Tools Assessing Performance (TAP) project seeks to extend this dataset to allow long term resource estimates and leverage it to better equip distributed wind equipment manufacturers, owner-operators, and installation professionals with better tools for practical siting applications. In this report, we present the results from our investigation within the TAP project focused on characterization of bias in WTK-based wind speed estimates and evaluation of vertical and horizontal interpolation techniques. We discuss the tradeoffs between different techniques and their combinations, as well as describe the lower bounds we determine for the studied validation errors. While the specific estimates we present are specific to WTK and the validation dataset we have chosen for this investigation (NREL's Wind Resource Meteorological Database), the overall analysis and the studied techniques are general enough to be applied to a broader set of wind datasets, both simulation-based and observational.

17 WIND ENERGY↗

Simple Wins: Driving Effective Implementation of Energy Efficiency Projects

Small- and medium-sized manufacturers (SMMs) in the United States, making up over 98% of manufacturing firms, account for 48.3% of the sector’s energy consumption. Despite access to energy assessments and technical resources, such as those from the US Department of Energy’s Better Plants program and Industrial Training and Assessment Centers, implementation rates for identified energy-saving measures remain lower than expectations, averaging 47%. Some barriers were identified by other researchers as limited workforce capacity, inadequate training, and time constraints hinder progress. This article studied the development of customized checklists together with the energy assessment report as a practical solution to improve implementation rates for energy efficiency projects among SMMs. The framework for the checklists was grounded in five principles: short, precise, actionable, relevant, and codeveloped (SPARC). A case study of a 500,000-squarefoot SMM demonstrates how tailored checklists targeting significant energy users—such as heating, ventilating and air conditioning (HVAC), lighting, and compressed air systems for this facility—can simplify the process for staff to do facility walkthroughs to monitor best practices and track the progress of energy efficiency project implementation.

Guo, Wei [Oak Ridge National Laboratory (ORNL), Oa↗

Carbon Transport and Storage Planning and Viability Support Tools

The EDX disCO2ver Carbon Transport and Storage Planning and Viability Support Tools are made up of the Carbon Storage Planning Inquiry Tool (CS PlanIT, Justman et al. 2024) and the Carbon Storage Technical Viability Approach Support Tool (CS TVA). Together, these tools support data access to support understanding data availability to support planning efforts for carbon transport and storage. The Carbon Storage Planning Inquiry Tool (CS PlanIT) is an online web mapping application designed to help users explore, query, and evaluate multiple data layers to support and accelerate carbon storage resource and feasibility assessments and planning efforts. CS PlanIT currently contains a range of datasets associated with geologic, technical, and infrastructure factors. The data sets can be filtered geographically for an area of interest to update statistics and charts within the dashboard. The dashboard is divided into different sections called widgets, relating to different steps in the carbon storage planning process. The resources in this submission include a link to PlanIT, as well as a data catalog and link to user documentation. The original citation for the CS PlanIT tool, which has now been integrated into the toolset here, was: - Devin Justman, Scott Pantaleone, Maneesh Sharma, Lucy Romeo, Paige Morkner, CS PlanIT (Carbon Storage Planning Inquiry Tool) , 6/28/2024, https://edx.netl.doe.gov/dataset/cs-planit-carbon-storage-planning-inquiry-tool, DOI: 10.18141/2377953 The Carbon Storage Technical Viability Approach Support (CS TVA) Tool displays spatial data availability for the many components of Geologic Carbon Storage (GCS) technical viability assessment (Creason al 2025). Identifying sites suitable for GCS requires evaluating the intersection of myriad factors, including reservoir conditions, subsurface and surface hazards, infrastructure requirements, and energy community metrics. The technical viability of a site can only be confirmed for instances where all these factors have data available, and where those data support viability. Additional Resources related to the Technical Viability Assessment Tool: - Julia Mulhern, Casey White, Araceli Lara, Neyda Cordero Rodriguez, Zachary Jackson, Jacob Shay, Gabriel Creason, MacKenzie Mark-Moser, Paige Morkner, Kelly Rose, Carbon Storage Technical Viability Approach (CS TVA) Database, 3/26/2025, https://edx.netl.doe.gov/dataset/edx4ccs-carbon-storage-technical-viability-approach-database , DOI:10.18141/1984655 - Julia Mulhern, MacKenzie Mark-Moser, Gabriel Creason, Casey White, Araceli Lara, Neyda Cordero Rodriguez, Zach Jackson, Paige Morkner, Kelly Rose, Carbon Storage Technical Viability Approach (CS TVA) Matrix, 3/27/2025, https://edx.netl.doe.gov/dataset/carbon-storage-technical-viability-approach-cs-tva-matrix , DOI: 10.18141/2539979 - Gabriel Creason, Zach Jackson, Neyda Cordero Rodriguez, Julia Mulhern, Casey White, Araceli Lara, MacKenzie Mark-Moser, Paige Morkner, Kelly Rose, Carbon Storage Technical Viability Approach (CS TVA) Data Availability Results Database, 3/27/2025, https://edx.netl.doe.gov/dataset/carbon-storage-technical-viability-approach-cs-tva-data-availability-results-database, DOI:10.18141/2538557

Carbon storage↗

Water and Wastewater Systems as Potential Distributed Energy Resources for California - High-level Feasibility Assessment

Water systems in California are a major electricity user, and electricity costs represent a significant portion of water utilities’ operating costs. Water and wastewater utilities have the capacity to shift demand in response to grid needs or price signals and can generate power through biogas, hydropower or onsite renewable energy systems like solar panels and wind turbines. This report points to some of the most promising opportunity areas for water and wastewater utilities to implement distributed energy resources while also carefully laying out practical considerations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Duke Energy Carbon-Free Resource Integration Study

Duke Energy has partnered with the National Renewable Energy Laboratory (NREL) to evaluate pathways to achieving their carbon-free targets and to assess the operational impacts of the resulting system. This report details findings from Phase II of the Duke Low Carbon Resource Integration study, which consisted of three separate but interrelated analyses: (1) a resource assessment exploring the technical and economic potential and characteristics of wind and solar resources in the Carolinas; (2) capacity expansion modeling identifying the least-cost investment pathways for achieving 70% CO 2 emissions reductions in North Carolina by 2030 and a net-zero electricity system by 2050; and (3) detailed production cost modeling of power system operations at the higher shares of low- and zero-carbon emitting generation sources, informed by the capacity expansion modeling portion of the analysis. The analysis finds that Duke Energy can approach the 2030 and 2050 emissions target in North Carolina through investment in a combination of solar, wind, and storage along with maintaining its existing nuclear fleet. The average cost of CO 2 abatement in the Carolinas through 2021-2050 is on the order of $\$27-33$ per metric ton (range of $\$9-34$ per metric ton across key sensitivities).Duke Energy can expected increased interchange with neighbors to help balance higher levels of solar, although the ability to do this will depend on whether neighboring regions also move to integrate more carbon-free resources. As Duke Energy moves toward both the 2030 and 2050 targets, addressing energy needs during the winter peak period becomes particularly important, and the system relies on the availability of resources such as renewable or hydrogen combustion turbines, seasonal storage, or other similar technologies that are dispatchable but able to operate at low capacity factors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Refined Method to Translate Solar Data Quality Assessment Flags to Estimated Measurement Uncertainty

Integrating solar resource uncertainties due to radiometer measurement performance and operational data quality assessment can provide improved estimates of economic bankability, system design performance, and compliance of solar energy conversion systems. Estimating radiometer measurement uncertainty is an established procedure consistent with recognized best practices and international guidelines. SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report, the fourth of six for the Data Quality and Uncertainty Integration Project, presents a refined algorithm description for software to translate solar resource data quality assessment results into estimated uncertainty values in a Solar Resource Operational Uncertainty Integrator (SROUI) application. This algorithm requires three-component solar irradiance measurements - global horizontal irradiance, direct normal irradiance, and diffuse horizontal irradiance - collected at 1- to 60-minute intervals, as described in the previous deliverables. The development of this report as Deliverable 6.4 was an iterative process that included reviews and feedback from the project team on initial drafts designed to refine how the new software could best support determining solar resource data uncertainty. The results of this effort will contribute to the final software system development by National Renewable Energy Laboratory staff.

14 SOLAR ENERGY↗