Micro heat pipe nuclear reactor concepts: Analysis of fuel cycle performance and environmental impacts

The demand for more practical and innovative nuclear reactor designs capable of providing clean energy to meet new global demands is revolutionizing the nuclear industry. Here, we present the fuel cycle and neutronics analysis of a design expected to be similar to the Westinghouse eVinci™ heat pipe (HP) reactor. The concept considered here uses low enriched urania rods and potassium liquid metal-cooled HPs to remove heat from the core. The fuel and HPs are contained in steel monolith to form the core which is surrounded by an alumina reflector. There is no need for forced circulation to remove heat from the active core region, thus eliminating the use of pumps, valves and tube piping. The concept is designed to operate safely and provide a reliable autonomous power supply in support of off-grid missions. This study shows that the HP reactor design can operate for more than 10 years without refueling. Further, we show that the current design of the HP reactor concept is best suited to serve as a nuclear battery rather than a centralized power source. We also studied the nuclear fuel cycle performance of the HP reactor concept in a once-through fuel cycle. The natural resource utilization, waste output, and environmental impact, as defined in a reference study from the literature, did not perform as well on a GWe per year energy basis compared to light water reactors with less than 5% enriched uranium in a once-through fuel cycle. Parasitic absorption in the steel monolith structure and neutron leakage lower the reactivity of the core, which decreases the discharge burnup of the fuel. Finally, analysis of modifications of the monolith material and size of the reference core configuration showed that the neutron leakage impact on the small sized HP core is the most limiting factor on the fuel cycle performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strategies for thorium fuel cycle transition in the SD-TMSR

Liquid-fueled Molten Salt Reactor (MSR) systems represent advances in safety, economics, and sustainability. The MSR has been designed to operate with a Th/ 233 U fuel cycle with 233 U used as startup fissile material. Since 233 U does not exist in nature, we must examine other available fissile materials to start up these reactor concepts. This work investigates the fuel cycle and neutronics performance of the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR) with different fissile material loadings at startup: High Assay Low Enriched Uranium (HALEU) (19.79%), Pu mixed with HALEU (19.79%), reactor-grade Pu (a mixture of Pu isotopes chemically extracted from Pressurized Water Reactor (PWR) spent nuclear fuel (SNF) with 33 GW d/tHM burnup), transuranic elements (TRU) from Light Water Reactor (LWR) SNF, and 233 U. The MSR burnup routine provided by SERPENT-2 is used to simulate the online reprocessing and refueling in the SD-TMSR. The effective multiplication factor, fuel salt composition evolution, and net production of 233 U are studied in the present work. Additionally, the neutron spectrum shift during the reactor operation is calculated. The results show that the continuous flow of reactorgrade Pu helps transition to the thorium fuel cycle within a relatively short time (≈ 4.5 years) compared to 26 years for 233 U startup fuel. Finally, using TRU as the initial fuel materials offers the possibility of operating the SD-TMSR for an extended period of time (≈ 40 years) without any external feed of 233 U.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conceptual core design of the molten metal fueled microreactor with self-regulating capability

The microreactor concept has received significant attention in the United States for its lower capital investment, siting flexibility and high mobility. A microreactor aims to provide reliable electricity in remote communities, mining areas, or isolated islands, which will save the high fuel transportation cost. Thus, minimizing the staff level for operating and maintaining a microreactor is desirable. The objective of the study is to design a self-regulated Molten Metal fueled microReactor core (MMR) and to demonstrate the self-regulating capability of the MMR core. The control of the reactor is solely relying on reactivity feedbacks from fuel temperature perturbation. Molten UMn (liquid form at the temperature over 720°C) was utilized as the fuel material in MMR due to the larger thermal expansion coefficient compared to the conventional solid fuel. The MMR core has a fast neutron spectrum, which corresponds to a small burnup reactivity swing. The core design parameters were selected based on DAKOTA, REBUS, and ANLHTP calculations. The MMR is designed to run for 10 years at a power level of 15 MWth. Furthermore, no refueling is needed during the reactor lifetime. The system dynamic analyses were performed, and it was found that the reactor can be self-regulating within a temperature range of 800 ± 80°C for a loss of heat sink transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-fidelity simulations of the run-in process for a pebble-bed reactor

Pebble-bed reactors (PBRs) rely on a continual feed of fuel pebbles being cycled through the core. As a result, they require a “run-in” period in order to reach an equilibrium state. The run-in period for a PBR is a complex, time-dependent problem that requires the injection of new fuel, different types of fuel, and power increases. This complexity in the run-in makes it important to capture the physical processes in order to generate an accurate representation. The present work details the creation of a high-fidelity Monte Carlo methodology for analyzing the run-in and subsequent approach to equilibrium for PBRs. The methodology entails a Python module wrapped around Serpent so as to perform neutronics calculations, move pebbles, refuel the core, and discharge pebbles, thereby modeling the explicit behavior of the PBR run-in. Further, three run-in simulations (a constant temperature profile, a linear temperature profile, and a constant temperature profile using control rods) were examined in order to identify the key physical phenomena present in the run-in process. Utilizing kugelpy, we found the inclusion of a temperature profile to be important for accurately capturing a discharge burnup (around 141 MWd/kg), a consistent k-eff (around 1.005), and an average pebble power (around 2.5 kW/pebble) that all fall within acceptable limits.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technology solutions to mitigate electricity cost for electric vehicle DC fast charging

Widespread adoption of alternative fuel vehicles is being hindered by high vehicle costs and refueling or range limitations. For plug-in electric vehicles, direct-current fast charging (DCFC) is proposed as a solution to support long-distance travel and relieve range anxiety. However, DCFC has also been shown to be potentially more expensive compared to residential or workplace charging. In particular, electricity demand charges can significantly impact electricity cost for fast charging applications. Here we explore technological solutions that can help reduce the electricity cost for electric vehicle fast charging. In particular, we consider thousands of electricity rates available in the United States and real-world vehicle charging load scenarios to assess opportunities to reduce the cost of DCFC by deploying solar photovoltaics (PV) panels and energy storage (battery), and implementing a co-location configuration where a DCFC station is connected to an existing meter within a commercial building. Results show that while the median electricity cost across more than 7000 commercial retail rates remains less than $0.20/kWh for all charging load scenarios considered, cost varies greatly, and some locations do experience significantly higher electricity cost. Co-location is almost always economically viable to mitigate fixed cost and demand charges, but the relative benefit of co-locating diminishes as station size and utilization increase. Energy storage alone can help mitigate demand charges and is more effective at reducing costs for 'peaky' or low-utilization loads. On the other hand, PV systems primarily help mitigate energy charges, and are more effective for loads that are more correlated with solar production, even in areas with lower solar resource. PV and energy storage can deploy synergistically to provide cost reductions for DCFC, leveraging their ability to mitigate demand and energy charges.

25 ENERGY STORAGE↗

OR-AGENT framework – Architecting electrified heavy-duty drayage applications

The widespread adoption of zero-emission vehicles in heavy-duty (HD) commercial freight transportation faces considerable technoeconomic challenges. For heavy-duty trucks, ensuring high uptime, cost parity with diesel, and safety standards is especially critical as these vehicles operate over long distances with heavy loads, where any downtime or off-nominal behaviors significantly impacts logistics, productivity, and the total cost of ownership. Unlike traditional diesel refueling, BEV charging infrastructure must be co-optimized with vehicle deployment, operational demands, and grid capacity to ensure cost-effective and reliable freight operations. However, the lack of a standardized ownership and service model has led to a fragmented approach—where commercial vehicle operators may invest in, own, and maintain both vehicle/batteries and charging/energy infrastructure. This disconnect may exclude energy service providers from the equation, forcing fleet operators to explore ‘behind-the-fence’ energy solutions that increase capital investment, operational downtime, overhead costs, and, in some cases, net carbon emissions. To address these issues, this study introduces OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport), a comprehensive modeling framework that integrates powertrain architectures, charging infrastructures, and energy backbone systems into a cohesive strategy. In this paper, OR-AGENT is applied to develop an interconnected systems architecture for energy efficiency and resiliency enhancement of heavy-duty drayage vehicles at the Port of Savannah, GA. This framework showcases an interconnected systems approach to electrifying heavy-duty drayage vehicles at the Port of Savannah, GA. The study assessed BEVs with 400–1200 kWh battery capacities, accounting for seasonal variations in weather and freight routing. A diverse charging mix (150 kW–1250 kW) was evaluated alongside grid capacity constraints, cost, and carbon intensity analysis, leading to the development of a strategic microgrid/Distributed Energy Resources (DER) deployment architecture to ensure a reliable and sustainable transition. However, the findings also highlight the need for alternative zero-emission solutions for remaining trips, such as larger batteries, electrified roadways, hydrogen powertrains, or net-zero emission fuels. In conclusion, the findings are incorporated into a Total Cost of Ownership (TCO) model to identify optimal architectures for an interconnected electrified ecosystem.

Commercial vehicles↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗

Total cost of ownership of vehicle electrification and fuel switching options for light-duty and heavy-duty vehicles

Projecting the transition from combustion engines to battery-based powertrains is complex becuase it involves numerous interdependent decisions. This study estimates total cost of ownership (TCO) to assess the economic viability of powertrain electrification, focusing exclusively on advances in vehicle and fuel technologies. Under two bounding technology-progress scenarios, we develop vehicle designs and fuel cost trajectories, which serve as inputs to TCO projections for selected classes from 2021 to 2050. We analyzed a small sport utility vehicle (SUV) to represent the light-duty vehicle (LDV) sector, and four medium- and heavy-duty vehicle (MHDV) classes: Class 6 box delivery, Class 8 drayage, Class 8 long-haul, and Class 8 transit bus. For each class, we compared the TCO of battery electric vehicles (BEVs) and fuel cell hybrid electric vehicles (FCHEVs) against conventional internal combustion engine vehicles (ICEVs). The results show that modern ICEVs generally have lower TCO; however, BEVs and FCHEVs could match or have lower TCOs than ICEVs over time, depending on technological progress. In LDVs, BEV300 is projected to deliver the lowest TCO by 2050, particularly under the high-progress scenario. In MHDVs, both BEVs and FCHEVs could become more cost-competitive than ICEVs by 2050 in the high-progress case. Beyond these results, the findings suggest further investigation is warranted for BEV charging infrastructure, FCHEV hydrogen refueling infrastructure, and MHDV charging strategies. In conclusion, these factors could reduce the fuel-cost share of TCO and enhance the competitiveness of BEVs and FCHEVs relative to ICEVs.

Battery electric vehicle↗

Potential energy and greenhouse gas emission effects of hydrogen production from coke oven gas in U.S. Steel Mills.

For this study, we examined the energy and emission effects of hydrogen production from coke oven gas (COG) on a well-to-wheels basis and compared these effects with those of other hydrogen production options, as well as with those of conventional gasoline and diesel options. We then estimated the magnitude of hydrogen production from COG in the United States and the number of hydrogen fuel cell vehicles (FCVs) that could potentially be fueled with the hydrogen produced from COG. Our analysis shows that this production pathway can achieve energy and greenhouse gas emission reduction benefits. This pathway is especially worth considering because first, the sources of COG are concentrated in the upper Midwest and in the Northeast United States, which would facilitate relatively cost-effective collection, transportation, and distribution of the produced hydrogen to refueling stations in these regions. Second, the amount of hydrogen that could be produced may fuel about 1.7 million cars, thus providing a vital near-term hydrogen production option for FCV applications.

01 COAL, LIGNITE, AND PEAT↗

Technical assessment of cryo-compressed hydrogen storage tank systems for automotive applications.

On-board and off-board performance and cost of cryo-compressed hydrogen storage are assessed and compared to the targets for automotive applications. The on-board performance of the system and high-volume manufacturing cost were determined for liquid hydrogen refueling with a single-flow nozzle and a pump that delivers liquid H{sub 2} to the insulated cryogenic tank capable of being pressurized to 272 atm. The off-board performance and cost of delivering liquid hydrogen were determined for two scenarios in which hydrogen is produced by central steam methane reforming (SMR) or by central electrolysis. The main conclusions are that the cryo-compressed storage system has the potential of meeting the ultimate target for system gravimetric capacity, mid-term target for system volumetric capacity, and the target for hydrogen loss during dormancy under certain conditions of minimum daily driving. However, the high-volume manufacturing cost and the fuel cost for the SMR hydrogen production scenario are, respectively, 2-4 and 1.6-2.4 times the current targets, and the well-to-tank efficiency is well short of the 60% target specified for off-board regenerable materials.

08 HYDROGEN↗

A comparative analysis of the cryo-compression and cryo-adsorption hydrogen storage methods

While conventional low-pressure LH₂ dewars have existed for decades, advanced methods of cryogenic hydrogen storage have recently been developed. These advanced methods are cryo-compression and cryo-adsorption hydrogen storage, which operate best in the temperature range 30–100 K. We present a comparative analysis of both approaches for cryogenic hydrogen storage, examining how pressure and/or sorbent materials are used to effectively increase onboard H₂ density and dormancy. We start by reviewing some basic aspects of LH₂ properties and conventional means of storing it. From there we describe the cryo-compression and cryo-adsorption hydrogen storage methods, and then explore the relationship between them, clarifying the materials science and physics of the two approaches in trying to solve the same hydrogen storage task (~5–8 kg H₂, typical of light duty vehicles). Assuming that the balance of plant and the available volume for the storage system in the vehicle are identical for both approaches, the comparison focuses on how the respective storage capacities, vessel weight and dormancy vary as a function of temperature, pressure and type of cryo-adsorption material (especially, powder MOF-5 and MIL-101). By performing a comparative analysis, we clarify the science of each approach individually, identify the regimes where the attributes of each can be maximized, elucidate the properties of these systems during refueling, and probe the possible benefits of a combined “hybrid” system with both cryo-adsorption and cryo-compression phenomena operating at the same time. In addition the relationships found between onboard H₂ capacity, pressure vessel and/or sorbent mass and dormancy as a function of rated pressure, type of sorbent material and fueling conditions are useful as general designing guidelines in future engineering efforts using these two hydrogen storage approaches.

08 HYDROGEN↗

Rapid high density cryogenic pressure vessel filling to 345 bar with a liquid hydrogen pump

Cryogenic pressurized hydrogen (H 2 ) vessels promise maximum storage density with potential to enabling practical H 2 vehicles with maximum driving autonomy and minimum cost of ownership. This paper adds a more complete evaluation of the benefits of cryogenic vessel technology by establishing a methodology for evaluating fill density for any initial vessel thermodynamic state. This is accomplished by assessing 24 cryogenic pressure vessel fill experiments with a liquid hydrogen (LH 2 ) pump manufactured by Linde and installed at the Lawrence Livermore National Laboratory (Livermore, CA) campus. The LH 2 piston pump takes LH 2 from the station Dewar at near ambient pressure (3 bar) and very low temperature (24.6 K) and pressurizes it to the vessel pressure in two stages of compression, up to 875 bar, although the rating of the cryogenic vessel used for these experiments limits fill pressure to 345 bar. Experiments spanned initial vessel temperatures from ambient to 22 K, enabling pump testing over a broad range of conditions. Experimental results validate many of the virtues that make LH 2 pumping a promising technology for H 2 dispensing, both for filling cryogenic as well as ambient temperature vessels: high throughput (1.67 kg/min, 100 kg/h), unlimited capacity for back to back refueling, low electricity consumption at the station due to high density of LH 2 minimizing compression work, and highest fill density, up to 80 g/L (estimated) when dispensing cryogenic hydrogen at 700 + bar. Analysis of the experiments shows that fill density can be predicted with reasonable accuracy (±0.7 g/L) by assuming 10 kJ/kg K cryogenic vessel inlet entropy (pump delivery hose outlet entropy). Fill lines are finally generated on a H 2 phase diagram, producing charts that can be used for rapidly determining fill density for any vessel condition at the moment of fill initiation.

08 HYDROGEN↗

Comparison of well-to-wheels energy use and emissions of a hydrogen fuel cell electric vehicle relative to a conventional gasoline-powered internal combustion engine vehicle

The operation of hydrogen fuel cell electric vehicles (HFCEVs) is more efficient than that of gasoline conventional internal combustion engine vehicles (ICEVs), and produces zero tailpipe pollutant emissions. However, the production, transportation, and refueling of hydrogen are more energy- and emissions-intensive compared to gasoline. In this research, a well-to-wheels (WTW) energy use and emissions analysis was conducted to compare a HFCEV (Toyota Mirai) with a gasoline conventional ICEV (Mazda 3). Two sets of specific fuel consumption data were used for each vehicle: (1) fuel consumption derived from the U.S. Environmental Protection Agency's (EPA's) window-sticker fuel economy figure, and (2) weight-averaged fuel consumption based on physical vehicle testing with a chassis dynamometer on EPA's five standard driving cycles. The WTW results show that a HFCEV, even fueled by hydrogen from a fossil-based production pathway (via steam methane reforming of natural gas), uses 5%–33% less WTW fossil energy and has 15%–45% lower WTW greenhouse gas emissions compared to a gasoline conventional ICEV. The WTW results are sensitive to the source of electricity used for hydrogen compression or liquefaction.

33 ADVANCED PROPULSION SYSTEMS↗

The cold high-pressure approach to hydrogen delivery

In view of the very expensive and wasteful nature of today's approaches to H 2 delivery, in this work we explore the possibility of transporting cold (200 K) high pressure (875 bar) H 2 in thermally insulated trailers and dispensing H 2 directly from the trailer, with the potential to eliminate station compressor, cascade, and refrigerator, leading to major reductions in station complexity, maintenance, electricity consumption, and cost, while improving functionality by enabling essentially unlimited back to back refuels, and improving safety due to reduced H 2 expansion energy at low temperature. Detailed techno-economic analysis shows promise for substantial delivery cost reductions through cold high pressure H 2 dispensed directly from the trailer. Results indicate that: (1) Terminal operations for cold high pressure H 2 delivery are $\$$0.32/kg H 2 more expensive than for 350 bar compressed gas delivery (today's lowest cost H 2 delivery technology) due to higher level of pressurization (to 1000 bar) and chilling needs (to 165 K). (2) Trailer cost drops slightly ($\$$0.73 vs. $\$$0.81/kg H 2 for a 350 bar trailer) due to increased capacity (1035 kg H 2 delivered vs. 700 kg) compensating for increased capital cost ($\$$906,900 for cold high pressure H 2 vs. $\$$634,000 for 350 bar trailer). (3) Cold hydrogen delivery presents major advantages in fueling station cost, reduced from $\$$1.27 to $\$$0.46/kg H 2 due to elimination of major system components: compressor, cascade, and chiller. (4) Total compression cost (terminal + station) drops from $\$$0.92/kg H 2 ($\$$0.32 terminal and $\$$0.60 station) for 350 bar trailers to $\$$0.55/kg H 2 (all at the terminal) for cold high pressure H 2 . (5) Elimination of small-scale station compressors is the main contributor to reduced delivery cost due to their inefficiency, capital expense, and maintenance needs. In summary, total delivery cost reduction vs. 350 bar trailer equals $\$$0.58/kg H 2 (from $\$$2.96 to 2.38/kg H 2 ), equivalent to 24% of the total delivery cost. This large cost advantage will improve the economics of H 2 vehicles facilitating the transition to a future of zero emission transportation.

08 HYDROGEN↗

Numerical predictions of cryogenic hydrogen vertical jets

Here, a comparison of Computational Fluid Dynamics (CFD) predictions with measurements is presented for cryo-compressed hydrogen vertical jets. The stagnation conditions of the experiments are characteristic of unintended leaks from pipe systems that connect cryogenic hydrogen storage tanks and could be encountered at a fuel cell refueling station. Jets with pressure up to 5 bar and temperatures just above the saturation liquid temperature were examined. Comparisons are made to the centerline mass fraction and temperature decay rates, the radial profiles of mass fraction and the contours of volume fraction. Two notional nozzle approaches are tested to model the under-expanded jet that was formed in the tests with pressures above 2 bar. In both approaches the mass and momentum balance from the throat to the notional nozzle are solved, while the temperature at the notional nozzle was assumed equal to the nozzle temperature in the first approach and was calculated by an energy balance in the second approach. The two approaches gave identical results. Satisfactory agreement with the measurements was found in terms of centerline mass fraction and temperature. However, for test with 3 and 4 bar release the concentration was overpredicted. Furthermore, a wider radial spread was observed in the predictions possibly revealing higher degree of diffusion using the k-ε turbulence model. An integral model for cryogenic jets was also developed and provided good results. Finally, a test simulation was performed with an ambient temperature jet and compared to the cold jet showing that warm jets decay faster than cold jets.

08 HYDROGEN↗

Hydrogen carriers: Production, transmission, decomposition, and storage

Recognizing the potential role of liquid hydrogen carriers in overcoming the inherent limitations in transporting and storing gaseous and liquid hydrogen, a complete production and use scenario is postulated and analyzed for perspective one-way and two-way carriers. The carriers, methanol, ammonia and toluene/MCH (methylcyclohexane), are produced at commercially viable scales in a central location, transmitted by rail or pipelines for 2000 miles, and decomposed near city gates to generate fuel-cell quality hydrogen for distribution to refueling stations. In terms of the levelized cost of H 2 distributed to the stations, methanol is less expensive to produce (1.22 dollars per kg-H 2 ) than MCH (1.35 dollars per kg-H 2 ) or ammonia (2.20 dollars per kg-H 2 ). Levelized train transmission cost is smaller for methanol (0.63 dollars per kg-H 2 ) than ammonia (1.29 dollars per kg-H 2 ) or toluene/MCH system (2.07 dollars per kg-H 2 ). Levelized decomposition cost is smaller for ammonia (0.30-1.06 dollars per kg-H 2 ) than MCH (0.54-1.22 dollars per kg-H 2 ) or methanol (0.43-1.12 dollars per kg-H 2 ). Over the complete range of demand investigated, 10-350 tpd-H 2 , the levelized cost of H2 distributed to stations is aligned as methanol « ammonia ~ MCH. With pipelines at much larger scale, 6000 tpd-H 2 , the levelized cost decreases by ~1 dollar per kg-H 2 for ammonia and MCH and much less for methanol. Methanol is a particularly attractive low-risk carrier in the transition phase with lower than 50-tpd H 2 demand.

08 HYDROGEN↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Material analysis of metal hydrides for bulk hydrogen storage

The United States Department of Energy (DOE) Hydrogen Storage Engineering Center of Excellence (HSECoE), 2009–2014, was established to evaluate the viability of material-based hydrogen storage for light duty vehicles. The HSECoE concluded that there were no metal hydrides that simultaneously met the DOE targets for gravimetric and volumetric capacity, and rate of onboard refueling. However, it was noted by the DOE that potential applications existed for stationary hydrogen storage systems. An application of particular interest is using a metal-hydride to store a hydrogen supply for fuel cell backup power to a 5 MWe data center. A generalized numerical model that coupled mass and energy conservation, chemical kinetics and thermodynamics was developed to simulate the discharge process for a given metal-hydride. The model was applied to an interstitial and a complex metal-hydride. In conclusion, it was found that the interstitial metal-hydride, which is discharged by a pressure swing is preferrable in a practical sense to the complex metal-hydride, which requires a temperature swing discharge process.