Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The CMS Barrel Calorimeter Processor demonstrator (BCPv1) board evaluation

For the CERN LHC phase 2, the barrel region of the CMS electromagnetic (ECAL EB) and hadronic calorimeters (HCAL HB) require new back-end electronics for their readout. To this purpose, a first version of the ATCA-based blade, the Barrel Calorimeter Processor (BCPv1), has been developed. The performance of the optical links as well as clock distribution are also presented here. Here, the BCPv1 has been tested together with front-end and trigger boards, as well as with the new DAQ and TCDS Hub (DTH) [1], to demonstrate that the BCPv1 meets the required specifications.

47 OTHER INSTRUMENTATION↗

The Silicon Inner Tracker of CMS: Construction, Organization and Future Upgrade

The silicon Inner Tracker is the innermost detector part of the CMS experiment at CERN. This detector contains about 200 m{sup 2} of precision silicon sensors, fast and radiation hard electronics, an optical readout and many more highly sophisticated components. The total number of sensor elements amounts to 9.3 million strips and 66 millions pixels. The strip detector is completely assembled and has been commissioned at the operating temperature of about--15 deg. C. A collaboration consisting of about 500 members coming from 51 institutes worldwide has designed and constructed this detector in a period of more than 12 years. The different components for the tracker were developed in cooperation with industrial partners. The Inner Tracker was installed in the CMS experiment at the end of 2007. A discussion on the upgrade of CMS and the Inner Tracker has already started in view of an increase in performance of the LHC collider. To cope with the even more demanding requirements expected for the next generation apparatus an extensive R and D period is about to start with many opportunities opening up for new collaboration members to join the effort.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility

Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >10 13 14 MeV DT neutrons or >10 9 n cm -2 ns -1 . Here, we describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.

47 OTHER INSTRUMENTATION↗

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

In this study, ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC) 2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

47 OTHER INSTRUMENTATION↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

Feasibility study of quantum computing using trapped electrons

In this study, we investigate the feasibility of using electrons in a linear Paul trap as qubits in a future quantum computer. We discuss the necessary experimental steps to realize such a device through a concrete design proposal, including trapping, cooling, electronic detection, spin readout, and single- and multiqubit gate operations. Numeric simulations indicate that two-qubit Bell-state fidelities of order 99.99% can be achieved assuming reasonable experimental parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

Shear horizontal surface acoustic wave microsensor for Class A viral and bacterial detection.

The rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms is critical to human health and safety. To achieve a high level of sensitivity for fluidic detection applications, we have developed a 330 MHz Love wave acoustic biosensor on 36{sup o} YX Lithium Tantalate (LTO). Each die has four delay-line detection channels, permitting simultaneous measurement of multiple analytes or for parallel detection of single analyte containing samples. Crucial to our biosensor was the development of a transducer that excites the shear horizontal (SH) mode, through optimization of the transducer, minimizing propagation losses and reducing undesirable modes. Detection was achieved by comparing the reference phase of an input signal to the phase shift from the biosensor using an integrated electronic multi-readout system connected to a laptop computer or PDA. The Love wave acoustic arrays were centered at 330 MHz, shifting to 325-328 MHz after application of the silicon dioxide waveguides. The insertion loss was -6 dB with an out-of-band rejection of 35 dB. The amplitude and phase ripple were 2.5 dB p-p and 2-3{sup o} p-p, respectively. Time-domain gating confirmed propagation of the SH mode while showing suppression of the triple transit. Antigen capture and mass detection experiments demonstrate a sensitivity of 7.19 {+-} 0.74{sup o} mm{sup 2}/ng with a detection limit of 6.7 {+-} 0.40 pg/mm{sup 2} for each channel.

60 APPLIED LIFE SCIENCES↗

Development of Large-Area Photo-Detectors (Final Scientific/Technical Report)

This proposal requested ADR funds for two years to make measurements and detector proto-types in the context of planning a program in conjunction with Argonne National Laboratory to develop very large-area planar photodetectors. The proposed detectors have integrated transmission-line readout and sampling electronics able to achieve timing and position resolutions in the range of 1-50 psec and 1-10 mm, respectively. The capability for very precise time measurements is inherent in the design, and provides a third coordinate, orthogonal to the two in the plane, for the point of origin of photons or charged particles, allowing tomographic reconstruction in 3-dimensions inside a volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T-1075: Large Area Fast Timing Beam Time of Flight (LAFTBToF) for ProtoDUNE

Large-area Picosecond Photodetectors (LAPPDs), developed at Argonne National Laboratory (ANL), present an opportunity to provide identification of charged particles in the 2-10 GeV/c range. Traditional methods using ionization or Cherenkov detectors require large amounts of material or pathlength for the particle to traverse in order to get a clean measurement, and are ill suited for particle beam identification in fixed-target experiments. The 6x6 cm 2 LAPPD uses mm-thick borosilicate glass micro-channel plates with a resistive surface coating added via atomic layer deposition. An electrical connection schematic of the LAPPD is shown in Figure 1. Electrons emitted by the photocathode are accelerated through the MCPs, which have µm-sized capillaries, and an avalanche of electrons is created as the electrons collide against the walls of the capillaries of the MCPs. The resulting electron avalanche is collected on anode strip lines and the signal may be read out on both ends of the stipline. The resistive coating of the thin MCPs and the short path length of the electrons to the readout results in fast rise times, gains of greater than 10 6 and typical timing resolutions of 50 ps. Differential timing on the ends of the strip lines can provide mm-level position measurements. The material of the bare LAPPD presents less than 0.05 of an interaction length and approximately 0.12 of a radiation length for a charged particle of I GeV/c. In our application, two large-area photodetectors separated by 5-10 meters can be used in a time-of-flight (ToF) measurement for 3σ separation of2-7 GeV/c charged pions, kaons and protons with minimal impact on the particle's trajectory and momentum.

43 PARTICLE ACCELERATORS↗

MaPSA Quality Control and AI-Enhanced Grading For the CMS Phase-II Tracker Upgrade

The Compact Muon Solenoid (CMS) experiment will undergo changes as part of the Large Hadron Collider upgrade. The CMS tracker will be upgraded to cope with the new radiation environment and to provide tracking at the first level trigger. This upgrade features a new type of silicon module called PS Module, which combines a Pixel sensor and a Strip sensor in the same module. The pixel portion of the PS module has a sensor bump bonded to 16 Macro Pixel ASICs (MPA) to form a Macro Pixel Sub Assembly (MaPSA). At Fermilab, MaPSAs are tested for quality control before being assembled with the strip sensors, readout and service electronics to form a PS Module. All of this test data is stored in a centralized database, and is used to grade the final module to determine if it will be installed in the detector. The Phase II Outer Tracker Analyzer of Test Outputs (POTATO) is the software that processes this data and determines the module grades. Using recent technologies, an AI agent is being im plemented into POTATO in order to allow users to more efficiently sort through the large amounts of analysis data and ensure that only the user specified data is being considered. This poster will display the process of testing a MaPSA, how that test data is relevant to module assembly and grading, and how the POTATO grading tool is being improved with the use of an embedded AI agent.

Gzamouranis, Olivia [Purdue U.]↗

A Micro-Opto-Mechanical Photoacoustic Spectrometer

This report describes progress achieved in a one-year LDRD feasibility study of a Photo Acoustic Spectrometer (PAS). Specifically, this team sought to create an all-optical and very small PhotoAcoustic Spectrometer Sensing system (PASS system). The PASS system includes all the hardware needed within a gas environment to analyze the presence of a large variety of molecules. The all-optical PASS system requires only two optical-fibers to communicate with the opto-electronic power and readout systems that exist outside of the gas environment. These systems can be at any distance from the PASS system as signal loss through the optical fibers is very small. The PASS system is intended to be placed in a small space where gases need to be measured and thus must be very small. The size and all-optical constraints placed on the PASS system demand a new design. The PASS system design includes a novel acoustic chamber, optical sensor, power fiber coupling and sensing fiber coupling. Our collaborators at the Atomic Weapons Establishment (AWE) have proven the capabilities of a complete photoacoustic spectrometer that uses a macro-scale PASS system (first 2 references). It was our goal to miniaturize the PASS system and turn it into an all-optical system to allow for its use in confined spaces that prohibit electrical devices. This goal demanded the study of all the system components, selection of an appropriate optical readout system and the design and integration of the optical sensor to the PASS system. A stretch goal was to fabricate a completed PASS system prototype.

42 ENGINEERING↗

Upgrades of the ATLAS Zero Degree Calorimeter System for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1 were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with $\text{H}_2$-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new "Reaction Plane Detectors" (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run~3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run~3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Micro-optical-mechanical system photoacoustic spectrometer

All-optical photoacoustic spectrometer sensing systems (PASS system) and methods include all the hardware needed to analyze the presence of a large variety of materials (solid, liquid and gas). Some of the all-optical PASS systems require only two optical-fibers to communicate with the opto-electronic power and readout systems that exist outside of the material environment. Methods for improving the signal-to-noise are provided and enable mirco-scale systems and methods for operating such systems.

47 OTHER INSTRUMENTATION↗

Design and Performance Testing of a Linear Array of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors for Uranium Enrichment Measurements

Abstract— Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution have been proposed for spectroscopy and imaging of gamma-ray sources in different applications. The flexibility of the array design, which can employ CZT crystals with thicknesses up to several centimeters in the direction of electron drift, allows for integration into different kinds of field-portable instruments. These can include small hand-held devices, compact gamma cameras and large field-of-view imaging systems. In this work, we present results for a small linear array of such detectors optimized for the low-energy region, 50-400 keV gamma-rays, which is principally intended for incorporation into hand-held instruments. There are many potential application areas for such instruments, including uranium enrichment measurements, storage monitoring, dosimetry and other safeguards-related tasks that can benefit from compactness and isotope-identification capability. The array described here provides a relatively large area with a minimum number of readout channels, which potentially allows the developers to avoid using an ASIC-based electronic readout by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of six (5x5.7x25 mm3) CZT detectors positioned in a line facing the source to achieve a maximum exposure area (~10 cm2). Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. The pad signals are converted into X-Y coordinates for each interaction event, which are combined with the cathode signals (for determining the Z coordinates) to give 3D positional information for all interaction points. This information is used to correct the response non-uniformity caused by material inhomogeneity, which therefore allows the usage of standard-grade (unselected) CZT crystals, while achieving high-resolution spectroscopic performance for the instrument. In this presentation we describe the design of the array, the results from detailed laboratory tests, and preliminary results from measurements taken during a field test.

36 MATERIALS SCIENCE↗

Design and Performance Testing of a Linear Array of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors for Uranium Enrichment Measurements

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution have been proposed for spectroscopy and imaging of gamma-ray sources in different applications. The flexibility of the array design, which can employ CZT crystals with thicknesses up to several centimeters in the direction of electron drift, allows for integration into different kinds of field-portable instruments. These can include small hand-held devices, compact gamma cameras and large field-of-view imaging systems. In this work, we present results for a small linear array of such detectors optimized for the low-energy region, 50-400 keV gamma-rays, which is principally intended for incorporation into hand-held instruments. There are many potential application areas for such instruments, including uranium enrichment measurements, storage monitoring, dosimetry and other safeguards-related tasks that can benefit from compactness and isotope-identification capability. The array described here provides a relatively large area with a minimum number of readout channels, which potentially allows the developers to avoid using an ASIC-based electronic readout by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of six (5x5.7x25 mm3) CZT detectors positioned in a line facing the source to achieve a maximum exposure area (~10 cm2). Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. The pad signals are converted into X-Y coordinates for each interaction event, which are combined with the cathode signals (for determining the Z coordinates) to give 3D positional information for all interaction points. This information is used to correct the response non-uniformity caused by material inhomogeneity, which therefore allows the usage of standard-grade (unselected) CZT crystals, while achieving high-resolution spectroscopic performance for the instrument. In this presentation we describe the design of the array, the results from detailed laboratory tests, and preliminary results from measurements taken during a field test.

36 MATERIALS SCIENCE↗

SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors

Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, cosmic microwave background, mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to transition-edge sensors or microwave kinetic inductance detectors. In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator’s excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at ~ 6 MHz with center frequencies ~ 5–6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.

47 OTHER INSTRUMENTATION↗

Time-resolved RIXS experiment with pulse-by-pulse parallel readout data collection using X-ray free electron laser

Abstract Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L 3 -edge on a charge-density-wave material TiSe 2 . The fast parallel Timepix readout and single photon sensitivity enable pulse-by-pulse data acquisition and analysis. Due to the FEL jitter, low detection efficiency of spectrometer, and low quantum yield of RIXS process, we find that less than 2% of the X-ray FEL pulses produce signals, preventing acquiring sufficient data statistics while maintaining temporal and energy resolution in this measurement. These limitations can be mitigated by using future X-ray FELs with high repetition rates, approaching MHz such as the European XFEL in Germany and LCLS-II in the USA, as well as by utilizing advanced detectors, such as the prototype used in this study.

36 MATERIALS SCIENCE↗

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗