Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Determining Eigenfrequencies and Homogeneous Widths of Lines of Intermolecular Vibrations in Water and in Aqueous Solutions of Hydrogen Peroxide Using Raman Spectroscopy

We have examined low-frequency Raman spectra of intermolecular vibrations of weak aqueous solutions of hydrogen peroxide and water. The differences between the observed Raman frequencies and the data from the literature on the IR-absorption frequencies of the same vibrations, as well as the interrelations between the frequencies and the widths of Lorentzian contours that approximate the vibrational spectra of the dynamic susceptibility, have been discussed. Based on a model of free damped vibrations of a classical oscillator with an inhomogeneous broadening, we have explained these effects for the first time. The homogeneous line widths and the damping times of the observed intermolecular vibrations have been determined. The eigenfrequencies of these vibrations have been calculated, and they have been shown to agree well with the data from the literature on the frequencies of IR absorption of water. We have shown that these parameters of intermolecular vibrations for water and for aqueous solutions of hydrogen peroxide differ from each other.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical in-situ determination of ortho-para hydrogen ratios via fiber-optic based Raman spectroscopy

An experiment was designed and developed to prototype a fiber-optic-based laser system, which measures the ratio of ortho-hydrogen to para-hydrogen in an operating neutron moderator system at the Los Alamos Neutron Science Center (LANSCE) spallation neutron source. Preliminary measurements resulted in an ortho to para ratio of 3.06:1, which is within acceptable agreement with the previously published ratio. As a result, the successful demonstration of Raman Spectroscopy for this measurement is expected to lead to a practical method that can be applied for similar in-situ measurements at operating neutron spallation sources.

43 PARTICLE ACCELERATORS↗

Tracking Optical Phonon Dynamics in InP Nanocrystals via Transient Absorption and Femtosecond Stimulated Raman Spectroscopy

Semiconductor nanocrystals (NCs) offer actualized and prospective utility in optoelectronic technologies, yet key aspects of their thermal and vibrational behaviors remain unresolved. Compared with bulk crystals, heat dissipation involving NCs can differ substantially owing to pervasiveness of interfacial scattering, phonon confinement, and relaxed phonon momentum selection rules, as well as influences of ligands. Here, in addition to transient absorption, we use femtosecond stimulated Raman spectroscopy to track nonequilibrium optical-phonon dynamics in InP NCs capped with myristic acid ligands and compare the same particles coated with a ZnS shell. We identify distinct phonon decay pathways in ligand-capped versus ZnS-shelled NCs. Increasing the excitation density and introducing the ZnS shell measurably modify optical-phonon lifetimes, whereas phonon formation times remain largely unchanged. In addition, we observe phonon mode softening in ligand-capped nanocrystals, consistent with lattice expansion. Together, these results demonstrate that core–shell structures can strongly govern nanocrystal thermal dissipation pathways and should be considered a key design parameter for optoelectronic operation.

dissipation↗

Rapid, antibiotic incubation-free determination of tuberculosis drug resistance using machine learning and Raman spectroscopy

Tuberculosis (TB) is the world’s deadliest infectious disease, with over 1.5 million deaths and 10 million new cases reported anually. The causative organism Mycobacterium tuberculosis (Mtb) can take nearly 40 d to culture, a required step to determine the pathogen’s antibiotic susceptibility. Both rapid identification and rapid antibiotic susceptibility testing of Mtb are essential for effective patient treatment and combating antimicrobial resistance. Here, we demonstrate a rapid, culture-free, and antibiotic incubation-free drug susceptibility test for TB using Raman spectroscopy and machine learning. We collect few-to-single-cell Raman spectra from over 25,000 cells of the Mtb complex strain Bacillus Calmette-Guérin (BCG) resistant to one of the four mainstay anti-TB drugs, isoniazid, rifampicin, moxifloxacin, and amikacin, as well as a pan-susceptible wildtype strain. By training a neural network on this data, we classify the antibiotic resistance profile of each strain, both on dried samples and on patient sputum samples. On dried samples, we achieve >98% resistant versus susceptible classification accuracy across all five BCG strains. In patient sputum samples, we achieve ~79% average classification accuracy. We develop a feature recognition algorithm in order to verify that our machine learning model is using biologically relevant spectral features to assess the resistance profiles of our mycobacterial strains. Finally, we demonstrate how this approach can be deployed in resource-limited settings by developing a low-cost, portable Raman microscope that costs <$5,000. We show how this instrument and our machine learning model enable combined microscopy and spectroscopy for accurate few-to-single-cell drug susceptibility testing of BCG.

60 APPLIED LIFE SCIENCES↗

Multivariate Linear Models for In Situ Monitoring of Low-Activity Nuclear Waste Using Infrared and Raman Spectroscopy - 20218

This paper presents the use of in situ monitoring tools for molecular analysis of non-radioactive species found in the supernatant liquid and dissolvable salt cake of nuclear waste at Hanford. We have selected two in situ spectroscopic techniques that do not require any sample preparation or consumables: infrared (in the form of attenuated total reflectance Fourier transform infrared or ATR-FTIR) and Raman spectroscopy. This work aims to evaluate their performance for liquid waste simulants representative of the Hanford DFLAW (Direct Feed Low-Activity Waste) feed. In addition, we have evaluated the performance of four multivariate linear models that extract concentrations from spectral measurements for a data set that was designed to include key molecular species found in liquid low-activity waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identifying Order and Disorder in Double Four-Membered Rings via Raman Spectroscopy during Crystallization of LTA Zeolite

Fluoride (F – ) has been essential for the synthesis of low-defect siliceous zeolites. It has been hypothesized that F – balances the positive charges from organic structure-directing agents (OSDAs) and stabilizes key building units during zeolite crystallization such as the double four-membered ring (D4R). However, due to the lack of characterization techniques for investigating medium-range structures, including rings and cages formed during zeolite crystallization, the roles of F – in stabilizing building units and maintaining local charge balance during zeolite assembly are not yet fully understood. Here, the crystallization of siliceous Linde type A (LTA) zeolite in the presence of F – was investigated using Raman spectroscopy and periodic density functional theory (DFT) calculations. We have discovered that the F – -filled double four-membered ring (F – /D4R) and the empty D4R exhibit rather distinct Raman features. Both the F – /D4R and empty D4R are formed in the LTA zeolite synthesized in the presence of F – using 1,2-dimethyl-3-(4-methylbenzyl) imidazolium as the OSDA. Observed Raman bands of the F – /D4R and empty D4R, along with predictive DFT calculations on LTA supercells, reveal an ordered distribution of these two D4R units in the final as-made LTA zeolite. The discovery of these distinct Raman signatures of F – /D4R and empty D4R units opens an interesting new window for studying defects in the D4R during zeolite formation. In particular, we have observed variation in Raman intensities of F – /D4R and empty D4R bands during LTA crystallization; periodic DFT calculations indicate that the observed Raman behavior is consistent with empty D4R units containing one or two Si vacancies surrounded by Q 3 Si—consistent also with solid-state nuclear magnetic resonance measurement. These defects appear to heal during further crystallization, leading to the formation of defect-free LTA zeolite crystals. Altogether, our results provide deeper understanding on the roles of F – in charge balancing and stabilizing intact D4R units during zeolite formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of large area plasmonic nanoparticle grating structure on silver halide based transmission electron microscope film and its application as a surface enhanced Raman spectroscopy substrate

The plasmonic responses of silver nanoparticle grating structures of different periods made on silver halide based electron microscope film are investigated. Raster scan of the conventional scanning electron microscope (SEM) is used to carry out electron beam lithography for fabricating the plasmonic nanoparticle grating (PNG) structures. Morphological characterization of the PNG structures, carried out by the SEM and the atomic force microscope, indicates that the depth of the groove decreases with a decrease in the grating period. Elemental characterization performed by the energy dispersive spectroscopy and the x-ray diffraction shows the presence of nanoparticles of silver in the PNG grating. The optical characterization of the gratings shows that the localized surface plasmon resonance peak shifts from 366 to 378 nm and broadens with a decrease in grating period from 10 to 2.5 μm. The surface enhanced Raman spectroscopy of the Rhodamine-6G dye coated PNG structure shows the maximum enhancement by two orders of magnitude in comparison to the randomly distributed silver nanoparticles having similar size and shape as the PNG structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of the REE 3+ aqua ions and chloride species in aqueous fluids by in situ Raman spectroscopy using perturbations of the water band

Acidic NaCl-rich aqueous fluids play a crucial role in forming hydrothermal rare earth elements (REE) mineral deposits. Aqueous REE mobility is mostly controlled by the stabilities of REE 3+ and REE chloride species. Our current knowledge of REE speciation is based on solubility data, thermodynamic models and in situ spectroscopic measurements, sometimes coupled with molecular simulations. Here, in this study, we investigate Nd and Yb speciation in pH2 Cl-bearing solutions at 25 °C and 0.1 MPa with variable Cl/REE ratios using Raman Spectroscopy in solutions with 0.1 to 0.6 mol/kg NdCl 3 or YbCl 3 and 0.2 to 3.2 mol/kg NaCl. Due to the challenges in resolving the REE-Cl band, we developed a new method using the water vibrational mode and multivariate curve resolution (MCR) analysis. The Raman spectra for the vibrational band of water (2700 to 3900 cm –1 ) were collected at 25 °C and fitted by three Gaussian sub-peaks, then quantified using MCR analysis to de-convolute the water band into bulk H 2 O and the perturbations caused by of Cl – , REE 3+ , and REE chloride species. REE speciation based on the perturbations of the water band indicates that REE 3+ aqua ions dominate acidic solutions at 25 °C, but up to ~20 mol% YbCl 2+ forms at high YbCl 3 concentrations. The new method is promising for quantifying in situ speciation of the REE 3+ aqua ions and REE chloride species in aqueous fluids while providing information on the hydration of ions. This method improves our molecular level understanding of REE aqueous species stability and their role in REE mobilization during fluid-rock interaction.

58 GEOSCIENCES↗

Effects of crystallization on micro-mechanical behavior of polyethylene nanocomposites using Raman spectroscopy

Recent work has shown that nanoparticles can be ordered in semicrystalline polymers by controlling the crystallization rate, specifically by forcing them to migrate to the amorphous regions of the lamellar morphology. Here, we study the micromechanical behavior of neat polyethylene and silica/polyethylene nanocomposites filled with 15 nm brush-modified silica in the quenched and slow-crystallized organized state. The molecular response to loading in tension was monitored with Raman spectroscopy using the peaks associated with crystalline and amorphous regions. The addition of nanofillers dramatically reduced the shift in the amorphous peaks, indicating that in addition to carrying some load, the brush-modified nanoparticles may be acting as tie molecules that restrict amorphous deformation. The higher degree of lamellar organization and the organization of the nanoparticles also impacted the crystalline peak shifts, but more subtly.

Polyethylene↗

New Material for Surface-Enhanced Raman Spectroscopy

A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

Farquharson, Stuart↗

The Effect of Heavy Ion Irradiation on the Forward Dissolution Rate of Borosilicate Glasses Studied In Situ and Real Time by Fluid-Cell Raman Spectroscopy

Borosilicate glasses are the favored material for immobilization of high-level nuclear waste (HLW) from the reprocessing of spent fuel used in nuclear power plants. To assess the long-term stability of nuclear waste glasses, it is crucial to understand how self-irradiation affects the structural state of the glass and influences its dissolution behavior. In this study, we focus on the effect of heavy ion irradiation on the forward dissolution rate of a non-radioactive ternary borosilicate glass. To create extended radiation defects, the glass was subjected to heavy ion irradiation using 197 Au ions that penetrated ~50 µm deep into the glass. The structural damage was characterized by Raman spectroscopy, revealing a significant depolymerization of the silicate and borate network in the irradiated glass and a reduction of the average boron coordination number. Real time, in situ fluid-cell Raman spectroscopic corrosion experiments were performed with the irradiated glass in a silica-undersaturated, 0.5 M NaHCO 3 solution at temperatures between 80 and 85 °C (initial pH = 7.1). The time- and space-resolved in situ Raman data revealed a 3.7 ± 0.5 times increased forward dissolution rate for the irradiated glass compared to the non-irradiated glass, demonstrating a significant impact of irradiation-induced structural damage on the dissolution kinetics.

36 MATERIALS SCIENCE↗

Photoinduced charge-transfer process in rubidium manganese hexacyanoferrate probed by Raman spectroscopy

The photoinduced charge-transfer process in Rb{sub 0.94}Mn[Fe(CN){sub 6}]{sub 0.98}{center_dot}0.2H{sub 2}O is investigated by observing the valence states of the metal ions by Raman spectroscopy. The sample in the high-temperature phase is irradiated at the ligand to metal, CN{sup -}{yields}Fe(III) and charge-transfer band ({lambda}=395 nm). The Fe(III)-CN-Mn(II) pair valence state corresponding to the high-temperature configuration is totally depleted after prolonged irradiation, and the Fe(II)-CN-Mn(III) pair valence state corresponding to the low-temperature configuration appears. In addition, two kinds of CN stretching modes, ascribed to Fe(II)-CN-Mn(II) and Fe(III)-CN-Mn(III) pair valence states, are found. The photoproduction process of each pair valence states is well reproduced by a kinetic model assuming a charge transfer from Mn(II) to Fe(III). During irradiation, continuous shifts of the Raman peaks are found and ascribed to a release of the strain due to the lattice mismatching between the high-temperature and the photoinduced phases. This behavior indicates that the photoinduced phase created locally in the high-temperature-phase lattice grows up to a photoinduced phase domain. The conversion efficiency is lowered with decreasing temperature, indicating the existence of an energy barrier. We propose a model, which can explain the existence of an energy barrier in the electronic excited state.

36 MATERIALS SCIENCE↗

Surface-Enhanced Raman Spectroscopy Combined with Multivariate Analysis for Fingerprinting Clinically Similar Fibromyalgia and Long COVID Syndromes

Fibromyalgia (FM) is a chronic central sensitivity syndrome characterized by augmented pain processing at diffuse body sites and presents as a multimorbid clinical condition. Long COVID (LC) is a heterogenous clinical syndrome that affects 10–20% of individuals following COVID-19 infection. FM and LC share similarities with regard to the pain and other clinical symptoms experienced, thereby posing a challenge for accurate diagnosis. This research explores the feasibility of using surface-enhanced Raman spectroscopy (SERS) combined with soft independent modelling of class analogies (SIMCAs) to develop classification models differentiating LC and FM. Venous blood samples were collected using two supports, dried bloodspot cards (DBS, n = 48 FM and n = 46 LC) and volumetric absorptive micro-sampling tips (VAMS, n = 39 FM and n = 39 LC). A semi-permeable membrane (10 kDa) was used to extract low molecular fraction (LMF) from the blood samples, and Raman spectra were acquired using SERS with gold nanoparticles (AuNPs). Soft independent modelling of class analogy (SIMCA) models developed with spectral data of blood samples collected in VAMS tips showed superior performance with a validation performance of 100% accuracy, sensitivity, and specificity, achieving an excellent classification accuracy of 0.86 area under the curve (AUC). Amide groups, aromatic and acidic amino acids were responsible for the discrimination patterns among FM and LC syndromes, emphasizing the findings from our previous studies. Overall, our results demonstrate the ability of AuNP SERS to identify unique metabolites that can be potentially used as spectral biomarkers to differentiate FM and LC.

60 APPLIED LIFE SCIENCES↗

Degradation Mechanism of Ag Nanorods for Surface Enhanced Raman Spectroscopy

This paper reports a degradation mechanism of silver (Ag) nanorods that are used as substrates for surface enhanced Raman spectroscopy (SERS). The attachment of sulfur and hydrocarbons to the surfaces of Ag nanorods is observed when they are stored in ambient over four months. This attachment is observed to correlate with ~20% decrease in SERS signal. The attachment, and thereby the signal degradation, takes three weeks to complete, and remains stable after the initial decay over the rest of the four month test period. While this degradation mechanism is a limitation to the gross enhancement, the ensuing stability beyond three weeks is encouraging.

42 ENGINEERING↗

Synchrotron X-ray diffraction and Raman spectroscopy of Ln{sub 3}NbO{sub 7} (Ln=La, Pr, Nd, Sm-Lu) ceramics obtained by molten-salt synthesis

Ln{sub 3}NbO{sub 7} (Ln=La, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) ceramics were obtained by molten-salt synthesis and their structures were systematically investigated by synchrotron X-ray diffraction (SXRD), second harmonic generation (SHG) and Raman spectroscopy. It was observed that ceramics with the largest ionic radii (La, Pr, Nd) crystallized into the Pmcn space group, while the ceramics with intermediate ionic radii (Sm-Gd) exhibited a different crystal structure belonging to the Ccmm space group. For this last group of ceramics, this result was corroborated by SHG and Raman scattering and ruled out any possibility for the non-centrosymmetric C 222{sub 1} space group, solving a recent controversy in the literature. Finally, according to SXRD, Tb-Lu containing samples exhibited an average defect fluorite structure (Fm3{sup ¯}m space group). Nonetheless, broad scattering at forbidden Bragg reflections indicates the presence of short-range domains with lower symmetry. Vibrational spectroscopy showed the presence of six Raman-active modes, inconsistent with the average cubic fluorite structure, and in line with the existence of lower-symmetry nano-domains immersed in the average fluorite structure of these ceramics. - Graphical abstract: Raman spectrum for Sm{sub 3}NbO{sub 7} ceramics showing their 27 phonon modes adjusted through Lorentzian lines. According to synchrotron X-ray diffraction and Raman scattering, this material belongs to the space group Cmcm. Display Omitted - Highlights: • Ln{sub 3}NbO{sub 7} ceramics were obtained by molten-salt synthesis. • SXRD, SHG and Raman scattering confirmed orthorhombic and cubic structures. • Ccmm instead of C222{sub 1} is the correct structure for Sm–Gd ceramics. • Pmcn space group was confirmed for La-, Pr- and Nd-based ceramics. • For Tb–Lu ceramics, ordered domains of a pyrochlore structure were observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise

This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2 , U 3 O 8 and an intermediate species U 3 O 7 in the third material.

36 MATERIALS SCIENCE↗

Ultrafast photo-induced nuclear relaxation of a conformationally disordered conjugated polymer probed with transient absorption and femtosecond stimulated Raman spectroscopies

A combination of transient absorption (TAS) and femtosecond stimulated Raman (FSRS) spectroscopies were used to interrogate the photo-induced nuclear relaxation dynamics of poly(3-cyclohexyl,4-methylthiophene) (PCMT). The large difference in inter-ring dihedral angles of ground and excited-state PCMT make it an ideal candidate for studying large-amplitude vibrational relaxation associated with exciton trapping. Spectral shifting in the S{sub 1} TA spectra on sub-ps timescales (110 ± 20 and 800 ± 100 fs) is similar to spectroscopic signatures of excited-state relaxation observed with related photoexcited conjugated polymers and which have been attributed to exciton localization and a combination of resonant energy transfer and torsional relaxation, respectively. Measurements made with both techniques reveal fast PCMT S{sub 1} decay and triplet formation (τ{sub S1} = 25–32 ps), which is similar to the excited-state dynamics of short oligothiophenes and highly twisted polyconjugated molecules. On ultrafast timescales FSRS of S{sub 1} PCMT offers a new perspective on the nuclear dynamics that underlie localization of excitons in photoexcited conjugated polymers: Spectral dynamics in the C=C stretching region (1400–1600 cm{sup −1}) include a red-shift of the in-phase C=C stretching frequency, as well as a change in the relative intensity of in-phase and out-of-phase stretch intensities on a timescale of ∼100 fs. Both changes indicate an ultrafast vibrational distortion that increases the conjugation length in the region of the localized excitation and are consistent with exciton self-localization or trapping. Wavelength-dependent excited-state FSRS measurements further demonstrate that the C=C stretching frequency provides a useful spectroscopic handle for interrogating the degree of delocalization in excited conjugated polymers given the selectivity achieved via resonance enhancement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗