Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Highly Segmented Silicon Strip Detectors for Radiation Detection (LDRD Final Report)

Large area highly segmented silicon strip detectors were investigated for use in applied radiation detection applications. Two ASIC-based readout electronics solutions were tested for compatibility. During the analysis, it was determined that significant computational resources and highly specialized firmware are required to reconstruct the data into a meaningful data stream for generalized spectroscopic performance. Future investment in the technology and careful choice of readout ASIC is expected to demonstrate relevance in measuring high activity samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-553: Characterization of Plastic Scintillator Detectors for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) designed for dosimetry of radiation therapy. Methods: The Exradin W1 Scintillator is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. The Cerenkov emissions were corrected using spectral separation. The optical signal was converted to electronic signal with a photodiode. We measured its dosimetry performance, including percentage depth dose, output factor, dose and dose rate linear response. We compared the dosimetry results with reference ion chamber measurements. Results: The dosimetry results of PSD agree well with reference ion chamber measurements. For percentage depth dose, the differences between PSD and ion chamber results are on average 1.7±1.1% and 0.8±0.8% with a maximum of 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 2% from ion chamber results. The dose linear response is within 1% when dose is larger than 20 MU for both 6 MV and 15 MV. The dose rate linear response is within 1% for the entire dose rate used (100 MU/min to 600MU/min). Conclusions: The current design of PSD is feasible for the dosimtry measurement in radiation therapy. This combination of PSD and photodiode system could be extended to multichannel array detection of dose distribution. It might as well be used as range verification in proton therapy. The work is partially supported by: DOD (W81XWH-09-2-0174) and American Cancer Society (IRG-78-002-28)

07 ISOTOPE AND RADIATION SOURCES↗

An InGaAs detector based radiation thermometer and fixed-point blackbodies for temperature scale realization at NIM

In this paper, we describe an InGaAs detector based radiation thermometer (IRT) and new design of fixed-point blackbodies, including Sn, Zn, Al and Cu, for the establishment of a temperature scale from 200 °C to 1085 °C at the National Institute of Metrology of China. The construction and calibration of the IRT with the four fixed-point blackbodies are described. Characteristics of the IRT, such as the size-of-source effect, the amplifier performance and its stability are determined. The design of the four fixed-points, with 10 mm diameter of aperture and 0.9999 emissivity, is described. The uncertainty of the scale realization is elaborated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hard AlGaN Detectors and Imager

Radiation hardness of AlGaN photodiodes was tested using a 65 MeV proton beam with a total proton fluence of 3x10{sup 12} protons/cm{sup 2}. AlGaN Deep UV Photodiode have extremely high radiation hardness. These new devices have mission critical applications in high energy density physics (HEDP) and space explorations. These new devices satisfy radiation hardness requirements by NIF. NSTec is developing next generation AlGaN optoelectronics and imagers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hazard Detector

NASA technology has made commercially available a new, inexpensive, conveniently-carried device for protection, of people exposed to potentially dangerous levels of microwave radiation. Microwaves are radio emissions of extremely high frequency. They can be hazardous but the degree of hazard is not yet well understood. Generally, it is believed that low intensity radiation of short duration is not harmful but that exposure to high levels can induce deep internal burns, affecting the circulatory and nervous systems, and particularly the eyes. The Department of Labor's Occupational Safety and Health Administration (OSHA) has established an allowable safe threshold of exposure. However, people working near high intensity sources of microwave energy-for example, radar antennas and television transmitters-may be unknowingly exposed to radiation levels beyond the safe limit. This poses not only a personal safety problem but also a problem for employers in terms of productivity loss, workman's compensation claims and possible liability litigation. Earlier-developed monitoring devices which warn personnel of dangerous radiation levels have their shortcomings. They can be cumbersome and awkward to use while working. They also require continual visual monitoring to determine if a person is in a dangerous area of radiation, and they are relatively expensive, another deterrent to their widespread adoption. In response to the need for a cheaper and more effective warning system, Jet Propulsion Laboratory developed, under NASA auspices, a new, battery-powered Microwave Radiation Hazard Detector. To bring the product to the commercial market, California Institute Research Foundation, the patent holder, granted an exclusive license to Cicoil Corporation, Chatsworth, California, an electronic components manufacturer.

Source record↗

Advanced Semiconductor Dosimetry in Radiation Therapy

Modern radiation therapy is very conformal, resulting in a complexity of delivery that leads to many small radiation fields with steep dose gradients, increasing error probability. Quality assurance in delivery of such radiation fields is paramount and requires real time and high spatial resolution dosimetry. Semiconductor radiation detectors due to their small size, ability to operate in passive and active modes and easy real time multichannel readout satisfy many aspects of in vivo and in a phantom quality assurance in modern radiation therapy. Update on the recent developments and improvements in semiconductor radiation detectors and their application for quality assurance in radiation therapy, based mostly on the developments at the Centre for Medical Radiation Physics (CMRP), University of Wollongong, is presented.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Z Sensitized Plastic Scintillators: A Review

The need for affordable and reliable radiation detectors has prompted significant investment in new radiation detector materials, due to concerns about national security and nuclear nonproliferation. Plastic scintillators provide an affordable approach to large volume detectors, yet their performance for high-energy gamma radiation is severely limited by the small radiation stopping power inherent to their low atomic number. Although some sensitization attempts with organometallics were made in the 1950s to 1960s, the concomitant decrease in light yield has limited the usefulness of these sensitized detectors. Recently, with new knowledge gained during the rapid development of organic optoelectronics and nanotechnology, there has been a revived interest in the field of heavy element sensitized plastic scintillators. In this paper, the recent efforts on sensitized plastic scintillators are summarized. Basic scintillator physics is first reviewed. The discussion then focuses on two major thrusts in the field: sensitization with: (1) organometallics and (2) oxide and fluoride nanoparticles. The design rationales and major results are examined in detail, with existing limitations and possible future pathways discussed. Lastly, special attention is paid to the underlying energy deposition and transfer processes, as these determine the key performance metrics such as light yield and radioluminescence decay lifetime.

36 MATERIALS SCIENCE↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pocket-size microwave radiation hazard detector

Inexpensive lightweight unit is easily carried in coat pocket or attached to belt, detector sounds alarm in presence of dangerous microwave radiation levels. Unit consists of antenna, detector, level sensor, keyed oscillator, and speaker. Antenna may be single equiangular spiral or set of orthogonal slot dipoles. Signal detector is simple diode in small package.

Kolbly, R. B.↗

Spreader-Bar Radiation Detection System Enhancements: A Modeling and Simulation Study

An investigation of radiation detectors on crane-mounted platforms was performed to understand the limitations and optimal capability of these types of systems. Crane-mounted systems are primarily focused on crane-mounted radiation detector systems, where the detectors are mounted on a spreader-bar platform. Spreader bars are attached with cables to a crane at seaports to load and unload containers from cargo ships. The bars can spread from 20 feet to 53 feet using hydraulics, allowing a single bar to move a variety of container lengths. Spreader-bars are also used on straddle carriers, which move containers around the laydown yard in the port. Spreader bar radiation detection (SBRD) systems are commercially available from at least two companies. These systems employ a set of spectroscopic sensors placed on the underside of a gantry crane and held near the top of a cargo container for detection. These systems have been previously tested and some issues and limitations observed. Radiation detectors mounted on spreader-bars are single sided systems (observing cargo only from the top) and it is therefore challenging to obtain the same sensitivity as double-sided systems (for example, portal monitors) especially when considering the possible amounts of intervening cargo that could be present. The approximately exponential attenuation of gamma rays in intervening dense cargo presents an inherent limitation to detection. However, SBRD systems hold detectors closer to the container, have a longer dwell time, and may have lower background (over the ship); all of these aspects help mitigate the single-sided issue. In addition, there are operational considerations that make spreader-bar radiation systems attractive. These include scanning for radiation during other operations (loading, unloading or container movement) which minimizes additional time for scanning, incorporating the radiation detection into existing equipment to minimize initial cost, and in the case of ship unloading, scanning the containers before reaching the laydown yard. This study is focused on researching optimized configurations of SBRD systems, including number of detectors, locations, and best use of detector data, to determine a reasonable limit on the capability of these types of systems. The results will help support decisions on where and how these systems might be effectively deployed, and could be used for future specification development for SBRD acquisition. The next phase of this research and investigation into SBRD systems and quantification of the possible improved capability with an enhanced SBRD is the focus of this report. Supporting this investigation, detailed models of an enhanced SBRD system were created using a 3D radiation transport code, and models were run to simulate the data from sources and background for a realistic cargo-loading port environment. The enhanced SBRD had increased detector material (numbers of detectors) compared to the commercial systems, with a distribution providing more uniform coverage. Measurements using small industrial sources were made with an enhanced SBRD system developed by Sandia National Laboratory to support model validation to establish credibility for the simulations of these threat and background scenarios. A significant simulation effort was undertaken to simulate sources of interest within a 40-foot cargo container. In order to estimate the performance of a generalized SBRD system in scenarios including background and cargo, a highly enriched uranium (HEU) test source (with 3x10 -8 232 U by weight) within a wood cargo model was simulated for a 40-foot cargo container. This source was placed at a variety of locations, and the flux from the source was multiplied as necessary to create estimated minimal detectable quantities (MDQ) figures for various quantities of HEU. Simulated data sets were produced corresponding to a complete container offloading scenario for a large number of statistical realizations. Significant work was performed on both the algorithm development and the container cargo distributions entering the US, and the result of this modeling, validation, and simulation effort was a set of estimates of the performance of a variety of radiation detection algorithms in this cargo-screening environment. In the case of algorithms, a variety of contemporary radiation detection and identification approaches were employed, and the optimal approaches to selecting time and location subsets of detector data were explored. In all cases, algorithm performance was compared, and the best approaches were suggested along with the best expected performance from the enhanced SBRD. In general, template-matching schemes employing a limited set of regression parameters tend to provide best results. The improvements of an enhanced SBRD with increased detector material and improved algorithms result in an effective MDQ of 10 kg of HEU in ~50 percent of the imported cargo in 40-foot containers, assuming a random source location. This is approximately two times the capability of the estimated performance of the commercial systems. For an MDQ of the 10 kg HEU source located in the worst location (bottom of the 40-foot container), the volume of cargo scanned drops to 10% for the enhanced SBRD, again a factor of two or more larger than the commercial systems. Enhancing the SBRD systems by adding more detectors, providing a more uniform coverage, and incorporating more advanced algorithms will result in a significant increase in capability. Although this investigation provided some indication of the performance capabilities of an enhanced SBRD system, additional work is needed to estimate the capability for other container configurations, such as the 20 and 45 foot containers. Since the 20-foot container weight limit is similar to the 40-foot, more dense cargo is typically shipped in 20-foot containers. This will result in a smaller percentage of cargo scanned for the 20-foot containers (for a particular source quantity) compared to the 40-foot containers. In addition to other configuration, other source material needs to be investigated to understand the capabilities for the entire threat space, where only HEU is considered in this work.

crane-mounted↗

Charged-particle spectroscopy in organic semiconducting single crystals

The use of organic materials as radiation detectors has grown, due to the easy processability in liquid phase at room temperature and the possibility to cover large areas by means of low cost deposition techniques. Direct charged-particle detectors based on solution-grown Organic Semiconducting Single Crystals (OSSCs) are shown to be capable to detect charged particles in pulse mode, with very good peak discrimination. The direct charged-particle detection in OSSCs has been assessed both in the planar and in the vertical axes, and a digital pulse processing algorithm has been used to perform pulse height spectroscopy and to study the charge collection efficiency as a function of the applied bias voltage. Taking advantage of the charge spectroscopy and the good peak discrimination of pulse height spectra, an Hecht-like behavior of OSSCs radiation detectors is demonstrated. It has been possible to estimate the mobility-lifetime value in organic materials, a fundamental parameter for the characterization of radiation detectors, whose results are equal to μτ{sub coplanar} = (5 .5 ± 0.6 ) × 10{sup −6} cm{sup 2}/V and μτ{sub sandwich} = (1 .9 ± 0.2 ) × 10{sup −6} cm{sup 2}/V, values comparable to those of polycrystalline inorganic detectors. Moreover, alpha particles Time-of-Flight experiments have been carried out to estimate the drift mobility value. The results reported here indicate how charged-particle detectors based on OSSCs possess a great potential as low-cost, large area, solid-state direct detectors operating at room temperature. More interestingly, the good detection efficiency and peak discrimination observed for charged-particle detection in organic materials (hydrogen-rich molecules) are encouraging for their further exploitation in the detection of thermal and high-energy neutrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of charge trapping on effective carrier lifetime in compound semiconductors: High resistivity CdZnTe

The dominant problem limiting the energy resolution of compound semiconductor based radiation detectors is the trapping of charge carriers. The charge trapping affects energy resolution through the carrier lifetime more than through the mobility. Conventionally, the effective carrier lifetime is determined using a 2-step process based on measurement of the mobility-lifetime product (μτ) and determining drift mobility using time-of-flight measurements. This approach requires fabrication of contacts on the sample. A new RF-based pulse rise-time method, which replaces this 2-step process with a single non-contact direct measurement, is discussed. The application of the RF method is illustrated with high-resistivity detector-grade CdZnTe crystals. The carrier lifetime in the measured CdZnTe, depending on the quality of the crystals, was between about 5 μs and 8 μs. These values are in good agreement with the results obtained using conventional 2-step approach. While the effective carrier lifetime determined from the initial portion of the photoresponse transient combines both recombination and trapping in a manner similar to the conventional 2-step approach, both the conventional and the non-contact RF methods offer only indirect evaluation of the effect of charge trapping in the semiconductors used in radiation detectors. Since degradation of detector resolution is associated not with trapping but essentially with detrapping of carriers, and, in particular, detrapping of holes in n-type semiconductors, it is concluded that evaluation of recombination and detrapping during photoresponse decay is better suited for evaluation of compound semiconductors used in radiation detectors. Furthermore, based on previously reported data, it is concluded that photoresponse decay in high resistivity CdZnTe at room temperature is dominated by detrapping of carriers from the states associated with one type of point defect and by recombination of carriers at one type of extended defects. The recombination at the extended defects produces long, logarithmic decay limiting substantially performance of CdZnTe detectors. This decay is associated with the “electrostatic trapping” of excess holes by the Schottky-type depletion space-charge regions formed around the defects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ship Effect Measurements With Fiber Optic Neutron Detector

The main objectives of this research project was to assemble, operate, test and characterize an innovatively designed scintillating fiber optic neutron radiation detector manufactured by Innovative American Technology with possible application to the Department of Homeland Security screening for potential radiological and nuclear threats at US borders (Kouzes 2004). One goal of this project was to make measurements of the neutron ship effect for several materials. The Virginia State University DOE FaST/NSF summer student-faculty team made measurements with the fiber optic radiation detector at PNNL above ground to characterize the ship effect from cosmic neutrons, and underground to characterize the muon contribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lanthanum halide nanoparticle scintillators for nuclear radiation detection

Nanoparticles with sizes <10 nm were fabricated and characterized for their nanocomposite radiation detector properties. This work investigated the properties of several nanostructured radiation scintillators, in order to determine the viability of using scintillators employing nanostructured lanthanum trifluoride. Preliminary results of this investigation are consistent with the idea that these materials have an intrinsic response to nuclear radiation that may be correlated to the energy of the incident radiation.

36 MATERIALS SCIENCE↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator array for radiation detection

A radiation detector includes a photodetector and a scintillator coupled thereto. The scintillator is formed of a scintillator material comprising an organic glass scintillator (OGS) material and at least one of a polymer additive or a plasticizer additive. The scintillator emits light when radiation is received at the scintillator, and the light is received by the photodetector. The radiation detector can further include a frame that has an interior cavity that holds the scintillator in position with respect to the photodetector, such that the light emitted by the scintillator is transmitted to the photodetector. The scintillator can be formed by casting amorphous scintillator material in the interior cavity of the frame. The frame can then be coupled to the photodetector to form the radiation detector.

Carlson, Joseph↗