Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A radiation hardened 256 x 4 bulk CMOS RAM

A radiation hardened version of the C2L process has been developed that utilizes all-low-temperature processes subsequent to channel oxidation. This process has been used on 1K RAMS. The RAMs functioned reliably at a dose of 200,000 rads (Si) and failed at a dose of 500,000 rads (Si). The 1K RAM is capable of operating from 7.5 to 12 volts and has an access time from address change of 160 nsec at 10 volts

Napoli, L. S.↗

Diffuse galactic gamma-ray line emission from nucleosynthetic Fe-60, Al-26, and Na-22 - Preliminary limits from HEAO 3

Data obtained during a two-week period in the fall of 1979 with the HEAO 3 gamma-ray spectroscopy experiment have been searched for diffuse galactic plane gamma-ray line emission expected t4 result from the decay of nucleosynthetic Fe-60, Al-26, and Na-22. With the possible exception of the 1809 keV line from Al-26 decay, for which a 2.6-omicron cosmic excess of (6.0 + or - 2.3) x 0.0001 photons/sq cm per sec per rad was measured, no positive detection was made. However, new limits ranging from 1.8 to 11 times 0.0001 photons/sq cm per sec per rad, at the 3-omicron level of confidence, have been placed on diffuse emission in these lines from the vicinity of the galactic center (between -30 and 30 deg). These limits are lower than some theories predict and thus place new constraints on the yields of these radionuclides in explosive nucleosynthesis and on the present rate of galactic nucleosynthesis.

Mahoney, W. A.↗

Radiation effects in IRAS extrinsic infrared detectors

During the calibration and testing of the Infrared Astronomy Satellite (IRAS) focal plane, it was observed that the extrinsic photoconductor detectors were affected by gamma radiation at dose levels of the order of one rad. Since the flight environment will subject the focal plane to dose levels of this order from protons in single pass through the South Atlantic Anomaly, an extensive program of radiation tests was carried out to measure the radiation effects and to devise a method to counteract these effects. The effects observed after irradiation are increased responsivity, noise, and rate of spiking of the detectors after gamma-ray doses of less than 0.1 rad. The detectors can be returned almost to pre-irradiation performance by increasing the detector bias to breakdown and allowing a large current to flow for several minutes. No adverse effects on the detectors have been observed from this bias boost, and this technique will be used for IRAS with frequent calibration to ensure the accuracy of observations made with the instrument.

Varnell, L.↗

Total dose effects in the 54HC family of microcircuits

Motorola and National Semiconductor 54HC00 and 54HC74 microcircuits were evaluated using CO-60 to determine their total dose radiation hardness. The devices were found to be radiation soft failing parametrically between 5 and 10 K rads and functionally between 20 and 40 K rads. The failures were bias dependent, relatively insensitive to dose rate, and only annealed moderately when left unbiased at room temperature.

Ropiak, S.↗

Total-dose and dose-rate dependence of proton damage in MOS devices during and after irradiation

Rad-hard CMOS/bulk inverters with input gates high and low were irradiated by protons with a nominal energy of 8 MeV in an effort to determine the total-dose and dose-rate dependence of threshold voltage shifts, both during and immediately after irradiation and over extended periods of time thereafter. It is shown that the effects in rad-hard MOS devices which are produced by specific proton and electron energies in the space environment could be simulated by cobalt-60 induced effects through careful and proper selection of total does and dose rates. This selection must be based on an experimentally established relationship of Co-60 to electron or proton damage. It is demonstrated that the simulation can be accomplished both during and after irradiation, in the long-term postirradiation period, as well as in the damage state immediately after bombardment.

Stassinopoulos, E. G.↗

Studies of molecular properties of polymeric materials: Aerospace environmental effects on three linear polymers

The development of crystal handling techniques for reflection infrared spectroscopy and methods for the fabrication and testing of tensile specimens are discussed. Data from mechanical, ac and dc electrical, and electron paramagnetic resonance studies conducted to determine the effects of 0.1-MeV and 1.0-MeV electron radiation on Mylar, Kapton, Ultem, and metal-doped Ultem are presented. Total doses ranging from 1 X 10 to the 8 rads to 1 X 10 to the 10 rads and dose rates from 5 X 10 to the 7 rads/hr to 1 X 10 to the 9 rads/hr were employed. The results of a study on the effects of aircraft service-environment fluids on Ultem are also reported. The weights and mechanical properties of Ultem were evaluated before and after exposure to water, JP4, Skydrol, an antifreeze, and a paint stripper.

Harries, W. L.↗

The effect of high energy (HZE) particle radiation (Ar-40) on aging parameters of mouse hippocampus and retina

Eight month old C57BL6 mice were exposed (head only) to 0.5 rad or 50 rads of Argon particles at the Lawrence Berkeley Radiation Facility, CA. Neuromotor performance was assessed monthly for six months beginning twelve weeks post-irradiation using a 'string test'. The decline in motor performance was dose-related and none of the animals was able to complete the task after four months of testing. Morphological changes were monitored six and twelve months post-irradiation by light and electron microscopy. The synaptic density in the CA-1 area of the hippocampus decreased six and twelve months after irradiation. The decrease after twelve months was less than after six months. The width of the outer nuclear layer (ONL) of the retina increased with increasing dose. The number of blood vessels between the ONL and the ganglion layer decreased twelve months after irradiation and this area did not show significant accumulation of age pigment.

Philpott, D. E.↗

Review of laser and RF systems for space proximity operations

The development of ranging and tracking systems for NASA space missions is discussed. Among the systems described are: rendezvous and docking (RAD) radar systems for the Gemini and Apollo programs; the Shuttle Rendezvous Ku-band radar system; and laser and TV docking systems RAD sensors systems for the Space Station. A multi-target microwave tracking system for Shuttle applications in the future is also described.

Krishen, K.↗

Long term effects of low doses of Fe-56 ions on the brain and retina of the mouse - Ultrastructural and behavioral studies

Eight-month-old male C57BL6 mice were exposed without anesthesia to whole-body irradiation in circular holders. The mice were tested for behavioral decrements after 0.5 and 50 rads of Fe particle irradiation at 6 and 12 months postirradiation to obtain long-term results. A standard maze was used, and the animals were timed for completion thereof. A string test also was administered to the mice, testing their ability to grasp and move along a string to safety. The results from animals exposed to 50 rads were significantly different from control results to p = less than 0.001 in both systems of testing. The hippocampus (believed to be the location of environmental interaction in the brain) and the retina were examined for ultrastructural changes. The ultrastructural changes were similar to those found in the Cosmos 782, 936, and Argon experiments. The mouse data indicate that iron particles were able to induce long-term changes in the central nervous system which led to behavioral impairment.

Philpott, Delbert E.↗

Experiment K-6-24, K-6-25, K-6-26. Radiation dosimetry and spectrometry

Radiation experiments flown by the University of San Francisco on the Cosmos 1887 spacecraft were designed to measure the depth dependence of both total dose and heavy particle flux, dose and dose equivalent, down to very thin shielding. Three experiments were flown and were located both inside and outside the Cosmos 1887 spacecraft. Tissue absorbed dose rates of 264 to 0.028 rad d(-1) under shielding of 0.013 to 3.4 g/sq cm of (7)LiF were found outside the spacecraft and 0.025 rad d(-1) inside. Heavy particle fluxes of 3.43 to 1.03 x 10 to the minus 3rd power cm -2 sub s -1 sub sr -1 under shielding of 0.195 to 1.33 g/sq cm plastic were found outside the spacecraft and 4.25 times 10 to the minus 4th power cm -2 sub s -1 sub sr -1 inside (LET infinity H2O greater than or equal to 4 keV/micron m). The corresponding heavy particle dose equivalent rates outside the spacecraft were 30.8 to 19.8 mrem d(-1) and 11.4 mrem d(-1) inside. The large dose and particle fluxes found at small shielding thicknesses emphasize the importance of these and future measurements at low shielding, for predicting radiation effects on space materials and experiments where shielding is minimal and on astronauts during EVA. The Cosmos 1887 mission contained a variety of international radiobiological investigations to which the measurements apply. The high inclination orbit (62 degrees) of this mission provided a radiation environment which is seldom available to U.S. investigators. The radiation measurements will be compared with those of other research groups and also with those performed on the Shuttle, and will be used to refine computer models employed to calculate radiation exposures on other spacecraft, including the Space Station.

Benton, E. V.↗

Radiation exposure of LDEF: Initial results

Initial results from Long Duration Exposure Facility (LDEF) include radiation detector measurements from four experiments; P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also at the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose dependence of a factor of approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly (SAA). On the trailing edge of the orbiter, a range of doses from 664 to 291 rad were measured under nominal shielding of 0.42 to 8.45 g/sq cm. A second set of detectors near this locations results are also given. On the leading edge, doses of 258 to 210 rad were found under shielding of 1.25 to 2.48 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses, and dose equivalents, for LET in H2O greater than or = 5 keV/micron, were measured with plastic nuclear track detectors located in the four experiments. Also, preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗

Space Exposed Experiment Developed for Students (SEEDS) P-0004-2

This cooperative endeavor of NASA Headquarters, the NASA Langley Research Center, and the George W. Park Seed Company, resulted in the distribution, by the end of March, 1990, of approximately 132,000 space exposed experiment developed for students (SEEDS) kits to 64,000 teachers representing 40,000 classrooms and 3.3 million kindergarden through university students. Kits were sent to every state, as well as to 30 foreign countries. Preliminary radiation data indicates that layer A received 725 rads, while layer D received 350 rads. Germination rate was reported to be 73.8 percent for space exposed seeds and 70.3 percent for earth based control seeds. Tests conducted within the first six months after retrieval indicated space exposed seeds germinated in an average of 8.0 days, while earth based control seeds' average germination rate was 8.3 days. Some mutations (assumed to be radiation induced) reported by students and Park Seed include plants that added a leaf instead of the usual flower at the end of the flower front and fruit produced from a flower with a variegated calyx bore seeds producing albino plants, while fruit from a flower with a green calyx from the same plant bore seeds produced green plants.

Grigsby, Doris K.↗

Radiation experiments on Cosmos 2044: K-7-41, parts A, B, C, D, E

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 deg and attitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10(exp -4) and 3.05 x 10(exp -4)/sq cm/s/sr, of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(sub infinity)-H2O is greater than or equal to 4 keV/micron. Neutron measurements yielded 0.018 mrem/d in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra were compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 deg) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCRs, and higher LET particles, in the heavy particle fluxes.

Frank, A. L.↗

Deep-space navigation with differenced data types. Part 3: An expanded information content and sensitivity analysis

An approximate six-parameter analytic model for Earth-based differential range measurements is presented and is used to derive a representative analytic approximation for differenced Doppler measurements. The analytical models are tasked to investigate the ability of these data types to estimate spacecraft geocentric angular motion, Deep Space Network station oscillator (clock/frequency) offsets, and signal-path calibration errors over a period of a few days, in the presence of systematic station location and transmission media calibration errors. Quantitative results indicate that a few differenced Doppler plus ranging passes yield angular position estimates with a precision on the order of 0.1 to 0.4 micro-rad, and angular rate precision on the order of 10 to 25 x 10(exp -12) rad/sec, assuming no a priori information on the coordinate parameters. Sensitivity analyses suggest that troposphere zenith delay calibration error is the dominant systematic error source in most of the tracking scenarios investigated; as expected, the differenced Doppler data were found to be much more sensitive to troposphere calibration errors than differenced range. By comparison, results computed using wideband and narrowband (delta) VLBI under similar circumstances yielded angular precisions of 0.07 to 0.4 micro-rad, and angular rate precisions of 0.5 to 1.0 x 10(exp -12) rad/sec.

Estefan, J. A.↗

Survey of electronics capability for SP-100 space reactor power system applications

Because of reports indicating improvements in the radiation tolerance of some electronic parts, a survey was recently performed by SP-100 project personnel to determine the advisability of revising SP-100 SRPS (space reactor power systems) allowable neutron and gamma dose rates in order to reduce the size and mass of the radiation shield and thereby achieve system mass reductions. The survey results indicate that recent developments to increase the radiation tolerance of a limited set of electronics parts do not justify increasing the allowable SP-100 dose rates for electronic components. Specifically, the recent improvements on a limited set of parts do not justify increasing the current SP-100 allowable specifications of 5 x 10 exp 5 rads gamma dose and 1 x 10 exp 13 neutrons/sq cm fluence. However, if the improvements of 108 rads for gammas and 10 exp 15 neutrons/sq cm can be extended to a wide range of parts, significant mass savings would result.

Manvi, Ram↗

In-flight identification of the Galileo spacecraft flexible mode characteristics

The Galileo scan platform is controlled in two degrees of freedom. A clock (Spin Bearing) actuator controls the relative position between the rotor and stator, and a cone actuator controls the position between the stator and the platform. Instruments on the platform are required to point to 140 micro-rad accuracy and 50 micro-rad per second stability. The system identification objectives were to identify dominant structural resonance frequencies, mode shapes, and damping ratio which exist in the transfer function between the clock actuator and the gyro sensor; and position the notch filter to limit undesirable actuator torque output to ensure stability and performance.

Wong, Edward C.↗

Two-micron Laser Atmospheric Wind Sounder (LAWS) pointing/tracking study

The objective of the study was to identify and model major sources of short-term pointing jitter for a free-flying, full performance 2 micron LAWS system and evaluate the impact of the short-term jitter on wind-measurement performance. A fast steering mirror controls system was designed for the short-term jitter compensation. The performance analysis showed that the short-term jitter performance of the controls system over the 5.2 msec round-trip time for a realistic spacecraft environment was = 0.3 micro rad, rms, within the specified value of less than 0.5 micro rad, rms, derived in a 2 micron LAWS System Study. Disturbance modes were defined for: (1) the Bearing and Power Transfer Assembly (BAPTA) scan bearing, (2) the spacecraft reaction wheel torques, and (3) the solar array drive torques. The scan bearing disturbance was found to be the greatest contributing noise source to the jitter performance. Disturbances from the fast steering mirror reaction torques and a boom-mounted cross-link antenna clocking were also considered but were judged to be small compared to the three principal disturbance sources above and were not included in the final controls analysis.

Manlief, Scott↗

Fission foil measurements of neutron and proton fluences in the A0015 experiment

Results are given from sets of fission foil detectors (FFD's) (Ta-181, Bi-209, Th-232, U-238) which were included in the A0015 experiment to measure combined proton/neutron fluences. Use has been made of recent FFD high energy proton calibrations for improved accuracy of response. Comparisons of track density measurements have been made with the predictions of environmental modeling based on simple 1-D (slab) geometry. At 1 g/cm(exp 2) (trailing edge) the calculations were approximately 25 percent lower than measurements; at 13 g/cm(exp 2) (Earthside) calculations were more than a factor of 2 lower. A future 3-D modeling of the experiment is needed for a more meaningful comparison. Approximate mission proton doses and neutron dose equivalents were found. At Earthside (13 g/cm(exp 2) the dose was 171 rad and dose equivalent was 82 rem. At the trailing edge (1 g/cm(exp 2) dose was 315 rad and dose equivalent was 33 rem. The proton doses are less than expected from TLD doses by 16 percent and 37 percent, respectively. These differences can be explained by uncertainties in the proton and neutron spectra and in the method used to separate proton and neutron contributions to the measurements.

Frank, A. L.↗