Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pumped Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

From Concept to Capital: How Developers Secure Private Investment

With an increased need for funding diversity in hydropower, private capital is becoming more important than ever. Investors are actively seeking opportunities, but what makes a project attractive for investment, and how can companies secure private equity or venture capital backing? This session brings together experts to discuss what capital providers look for in providing financing for hydropower projects. Panelists will explore key barriers - such as the lack of diversified portfolios and long-term revenue certainty - and strategies to overcome them through innovative financing mechanisms, partnerships, and market-driven solutions.

16 TIDAL AND WAVE POWER↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

Regenerative Fuel Cell System (Cooperative Research and Development Final Report, CRADA Number CRD-16-635)

Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.

13 HYDRO ENERGY↗

Techno-economic analysis of long-duration energy storage and flexible power generation technologies to support high-variable renewable energy grids

As variable renewable energy penetration increases beyond 80%, clean power systems will require long-duration energy storage or flexible, low-carbon generation. Here, we provide a detailed techno-economic evaluation and uncertainty analysis of applicable technologies and identify challenges and opportunities to support electric grid planning. We show that for a 120-h storage duration rating, hydrogen systems with geologic storage and natural gas with carbon capture are the least-cost low-carbon technologies for both current and future capital costs. These results are robust to uncertainty for the future capital cost scenario, but adiabatic compressed air and pumped thermal storage could be the least-cost technologies in the current capital cost scenario under uncertainty. Finally, we present a new storage system using heavy-duty vehicle fuel cells that could reduce the levelized cost of energy by 13%–20% compared with the best previously considered storage technology and, thus, could help enable very high (>80%) renewable energy grids.

25 ENERGY STORAGE↗

PART 1- techno-economic analysis of a grid scale Ground-Level Integrated Diverse Energy Storage (GLIDES) technology

In this paper, a techno-economic model / cost reduction analysis of a low-cost, dispatchable / scalable, efficient Ground-Level Integrated Diverse Energy Storage (GLIDES) system is analyzed, along with a review of existing state-of-the-art energy storage technologies. The introduced technology, GLIDES, which was invented at the Oak Ridge National Laboratory (ORNL), stores energy by compression and expansion of air using water as a liquid piston inside high-pressure reservoirs. GLIDES is introduced by combining Pumped Hydroelectric Storage (PHS) and Compressed Air Energy Storage (CAES) technologies. Here, by replacing inefficient gas compressor and turbine with higher efficiency liquid turbomachines for liquid-piston compression/expansion, GLIDES achieves higher roundtrip efficiency than other gas compression-based energy storage technologies and is a scalable energy storage system. For cost reduction purposes, various pressure reservoirs including steel vessels, carbon fiber vessels, pipe segments, and underground pressure reservoirs are analyzed in this paper. Based on the analyzed data using the models discussed in this paper, energy storage costs as low as ~$14/kWh and ~346/kWh (roundtrip efficiency (RTE) ~80%) can be achieved for a grid-scale GLIDES using depleted oil/gas reservoirs and high-pressure pipe segments respectively.

25 ENERGY STORAGE↗

The Design of a Multiphase CO2 Turbine Test Facility

As the energy market continues to evolve with increased renewables, such as solar and wind energy, the need to balance energy demand with its availability has become increasingly more challenging. The country’s aggressive decarbonization goals in the upcoming decades will increase renewable energy market penetration, thus exacerbating the disparity between energy demand and renewable resource availability. Long-duration energy storage technologies, such as pumped thermal energy storage (PTES), are potential solutions to this challenge with high potential round-trip efficiency (RTE), no geological or geographical constraints, and low safety risks. The charge mode of a PTES system operates a heat pump cycle, converting input power to thermal energy in hot and cold reservoirs. Fundamentally, heat pumps are commonly used in daily life, but the operating conditions required by high RTE PTES systems are outside the design experience of these systems. The low-pressure side of the cycle for a supercritical CO2 (sCO2) PTES operates just above the vapor-dome and potentially drives the turbine to expand into the dome, resulting in multiphase operation in the rear stages of the turbine. This paper presents the design of the test facility for an advanced multiphase-tolerant sCO2 turbine for the heat pump of a PTES system. Heat rejection and pressure loss estimations for the multiphase sections of the test loop presented unforeseen challenges.

25 ENERGY STORAGE↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

A Comprehensive Framework for Valuation of Ecosystem Services in the Context of Hydropower

While models to value ecosystem services exist, they suffer from a lack of “portability” in the sense that a single modelling framework developed for one site cannot be imported and applied to another. Additionally, benefit estimations are often fragmented, incomplete, incomparable, and in heterogenous metrics, thus preventing aggregation to arrive at one comprehensive value. In the context of hydropower, the methods, as well as the metrics used to value the associated ecosystem services, vary between stakeholders (e.g., competing water users, agencies, etc.), detracting from the ability to assess the total value of a hydropower project, water management schemes, or comparing value between competing water users. Further, current methods to value water neglect non-market ecosystem services’ values by failing to account for externalities, resulting in misallocation of costs (e.g., obligatory stakeholder payments for water use) and misinterpretation of hydropower benefits. The benefit-cost ratios in hydropower development are often incomplete because non-market benefits are excluded (e.g., benefits, such as fish habitat resiliency and agricultural water reliability, derived from hydropower development). An approach to enable consistent, standardized hydropower benefit-cost analyses does not currently exist. This paper conceptualizes a methodology to standardize ecosystem services valuation in the context of hydropower projects through the integration of the U.S. Environmental Protection Agency’s existing Final Ecosystem Goods and Services Classification System framework and economic valuation techniques, and demonstrates the applicability of this methodology through a limited proof-of-concept application (the New Waddell Plant, a pumped hydroelectric energy storage facility in Phoenix, AZ). The beauty of our proposed framework lies in its ability to be imported and applied to any other pumped storage facility after accounting for site-specific features.

13 HYDRO ENERGY↗

Medium-temperature phase change material integration in domestic heat pump water heaters for improved thermal energy storage

In this review, we examine state-of-the-art developments in integrating phase change materials (PCMs) for thermal energy storage (TES) in domestic heat pump water heaters (HPWHs). The component design optimization and control optimization of HPWHs and TES are reviewed for insight into improving the thermal capacity and efficiency of a PCM-integrated HPWH. The state-of-the-art review is categorized by the stage of development of the PCM for deployment in HPWHs. To select appropriate PCMs for HPWHs, a six-factor down-selection process is used to determine the best material(s) for integration in HPWHs with appropriate heat exchanger design. Ultimately, food-grade PCMs appear to be the best candidate for integration of TES in domestic HPWHs because they are nontoxic, highly cyclable, and have heat transfer properties accommodable to water heating when integrated in a manner to overcome the thermal conductivity limitations of the material. A key parameter of water heating performance is thermal heating power of the PCM component, which is not often reported. Many studies report significant improvement in capacity and efficiency. Furthermore, many performance metrics are identified from the literature to quantify the system performance, but agreement across studies is not found. Unified energy factor and first hour rating performance tests are required for commercially available HPWHs, and these performance metrics could homogenize the literature. Ultimately, we find that select PCMs are ready for deployment with HPWHs for performance improvement, and component design and control optimizations are new avenues of research and development required for a commercially viable PCM-integrated HPWH system.

25 ENERGY STORAGE↗

THESEUS: A techno-economic design, integration and downselection framework for energy storage

Optimal selection of energy storage technologies is critical to ensure reliable integration of intermittent and often uncertain renewable energy in electricity grids. The consideration of a diverse set of energy storage technologies is required for a more sustainable deployment of energy storage. We present THESEUS (TecHno-Economic framework for Systematic Energy storage Utilization and downSelection), which is a comprehensive framework for the optimal selection, design and operation of energy storage systems. THESEUS includes rigorous models of major energy storage technologies at different maturity levels, such as thermal storage using phase-change materials or molten salt, cryogenic storage, mechanical storage in the form of compressed air and pumped hydro storage, chemical storage using hydrogen, and electrochemical storage in the form of lithium-ion, sodium sulfur and vanadium flow batteries. An illustrative case study on state-wide prospective energy storage shows that storage integration with fossil power plants could reduce the cost of meeting the grid energy demand by 20%, with mechanical storage as the best suited technology. Although high-temperature thermal storage has low storage efficiency, it is optimal for integration with renewable energy plants. In addition, Li-ion batteries are optimal for high ramping but low storage duration requirements. Furthermore, such insights can enable the deployment of both existing and emerging energy storage technologies to facilitate a smooth transition to a clean energy future.

25 ENERGY STORAGE↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

Storage Effectiveness in Enabling Variable Generation and Avoiding Fossil Emissions

In this paper, we investigate the relationship between storage and variable generation (VG) and how they can be used to replace fossil-fired technologies and their associated emissions. Unlike fossil generation, VG relies on variable resources (wind, solar, etc.), and the timing of these resources does not always match system needs, creating challenges both in terms of when energy is delivered and the reliability of that delivery. These challenges are typically addressed in one of two ways: paring VG with storage to provide firmed, time-shiftable energy or by building additional VG throughout an interconnection so that adequate amounts of VG are always available. The choice of how much to build of each (storage and VG) is typically an economic one. In this work, we focus on the former case - investigating the role of storage in bringing renewables onto the grid.

13 HYDRO ENERGY↗