Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Insights into the laser-assisted photoelectric effect from solid-state surfaces

Photoemission from a solid surface provides a wealth of information about its electronic structure and dynamic evolution. Ultrafast pump-probe experiments offer real-time access to photon-surface interactions and the resulting electron dynamics. Here, we present a femtosecond time-resolved photoelectron spectroscopy study of laser-assisted photoemission (LAPE) from two different metal surfaces, tungsten and platinum. Utilizing synchronized IR laser and x-ray pulses, photoelectron sideband generation up to the sixth order is observed. A significant material-dependent variation of the LAPE response has not been predicted by previous theoretical models, to the best of our knowledge. The observed phenomena are semiquantitatively reproduced by considering distinct dynamic dielectric responses of the two materials. In conclusion, these findings provide a deeper understanding of the LAPE process and insights into the dynamic interplay between optical laser fields and metal surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Generic Multivector Model Predictive Control With Symmetric Pulse Pattern for Hybrid Multilevel Converters

This article presents a generic multivector model predictive control (MV-MPC) method that has the potential to be applied to all hybrid multilevel converters (HMCs). It first locates the reference voltage vector in the 120° oblique coordinate to select the three adjacent voltage vectors to be applied over one control cycle. Then, the current tracking is guaranteed through duty cycle optimization and dc capacitor voltages are balanced by evaluating possible switching sequences that belong to the voltage vectors with optimal duty cycles. At last, the optimal switching sequence with a symmetric five- or seven-segment pulse pattern is generated using an external modulator. Here, the proposed generic MV-MPC can significantly improve the quality of the output current, while achieving a constant equivalent switching frequency at the same time. Experimental studies on an all silicon carbide HMC prototype, i.e., an active neutral point clamped converter with cascaded H-bridge, are presented to validate the effectiveness of the proposed MV-MPC strategy.

42 ENGINEERING↗

Evidence for anti-synergism between ion-assisted etching and in-plasma photoassisted etching of silicon in a high-density chlorine plasma

Etching of p-Si in 60 mTorr 10%Cl2/90%Ar Faraday-shielded inductively coupled high density plasmas was investigated under both ionassisted etching (IAE) and photoassisted etching (PAE) conditions. Real-time etching rates and after-etching Si surface chemical compositions were obtained by laser interferometry and vacuum-transfer x-ray photoelectron spectroscopy (XPS), respectively. Precisely controlled ion energy distributions (IEDs) were generated by applying pulsed negative DC bias on the conductive sample stage. Above a 36 eV threshold at a total flow rate of 250 SCCM, the IAE rate increased with the square root of the ion energy. In contrast to the DC bias, etching under RF bias did not exhibit a threshold ion energy because of the wide IED. XPS spectra revealed that the surface layer under PAE conditions had a significantly lower chlorine content, composed of only SiCl. Under IAE conditions, however, silicon dangling bonds (Si•), SiCl 2 , and SiCl 3 were found on the surface, in addition to SiCl, with a relative abundance of SiCl > SiCl 2 , and SiCl 3 . The absence of higher chlorides and Si• under PAE conditions suggested that vacuum ultraviolet photons and above threshold-energy ions interact with the surface very differently. By varying the duty cycle of the pulsed DC bias, it was found that the IAE rate scaled with the energetic ion dose, but only for low duty cycles. For higher duty cycles, the apparent IAE yield fell off with an increasing Cl coverage on the surface, as the duty cycle went up, which pointed to a negative synergy (antisynergism) between PAE and IAE as the explanation. This antisynergism was further supported by the observed decrease of the total etching rate with an increasing period of the pulsed DC bias. A plausible mechanism is that increasing the pulsing period causes more near-surface damage, creating more recombination centers that lead to a higher loss rate of electron-hole pairs through recombination, thereby reducing the PAE rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lasing in 15 atm CO 2 cell optically pumped by a Fe:ZnSe laser

10 µm lasing is studied in a compact CO 2 -He cell pressurized up to 15 atm when optically pumped by a ∼50 mJ Fe:ZnSe laser tunable around 4.3 µm. The optimal pump wavelength and partial pressure of CO 2 for generating 10 µm pulses are found to be ∼4.4 µm and 0.75 atm, respectively. Without cavity optimization, the optical-to-optical conversion efficiency reached ∼10% at a total pressure of 7 atm. The gain lifetime is measured to be ∼1 µs at pressures above 10 atm, indicating the feasibility of using high-pressure optically pumped CO 2 for the efficient amplification of picosecond 10 µm pulses.

Tovey, Dana↗

Expanded Capabilities and Opportunities for Virtual Beamline Code

In the 25 years since LLNL broke ground on the National Ignition Facility (NIF) - a cornerstone of the National Nuclear Security Administration’s Stockpile Stewardship Program - the NIF and Photon Science (NIF&PS) Directorate has steadily pushed the boundaries of laser physics, nonlinear optics, and photonics in service of inertial confinement fusion experiments, and advanced photon sources development. Beyond the 192 beamlines of the primary laser facility with its world-record energy and fusion yields, NIF&PS capabilities have expanded to include chirped-pulse amplification, kilojoule petawatt-class short-pulse systems to generate hard x-ray radiographic probes, high-average power lasers as secondary sources for generation or wake field particle acceleration along directed energy applications, and other scientific pursuits. The Computing Directorate partners with NIF&PS on numerous projects and technologies from diagnostic measurements and high performance control systems to data analysis, information technology infrastructure, and scientific simulation code development. “This strong collaboration enables cutting-edge science, particularly with regard to physics-based modeling and simulation,” says physicist Jean-Michel Di Nicola. One crucial capability for NIF&PS is the Virtual Beamline (VBL) laser simulation code. It can model all the major laser physics and technology involved in the design optimization, commissioning, and operations of advanced laser architectures from tabletop to NIF-scale. VBL provides researchers with high-fidelity models and high-resolution calculations of laser performance predictions—including for the entire NIF laser system, the Advanced Radiographic Capability, parts of the High Repetition-Rate Advanced Petawatt Laser System laser delivered to the Czech Republic, and the Optical Science Laser. After more than two decades of experimentally verified physics and computing enhancements, this unique workhorse code is wrapping up another major milestone: migration from Java to C++ with a flurry of user interface and optimization features, as well as laser physics and high-resolution enhancements thanks to parallel execution on Livermore Computing platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray Source Characteristics from July 2020 SGEMP Experiments at the National Ignition Facility

This report details the measured x-ray characteristics radiating from laser targets on 7 shots at Lawrence Livermore National Laboratory's National Ignition Facility performed June 30 - July 2, 2020. Generally, the x-ray sources were designed to serve as meaningful drivers of a variety of Radiation Effects Sciences response experiments. Specifically, on these 7 shots, the measured x-ray output characteristics and the response experiments serve as a useful data set for validating performance and informing further development of Sandia National Laboratories' EMPIRE code. We present x-ray measurements and analyses relevant to simulating the System-Generated Electro Magnetic Pulse experiments that also occurred on these shots (described elsewhere). Sufficient detail is provided so that a motivated, but novice, x-ray source user could produce some of these analysis results from raw data on similar x-ray shots.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory Study of Magnetic Reconnection in Lunar-relevant Mini-magnetospheres

Abstract Mini-magnetospheres are small ion-scale structures that are well suited to studying kinetic-scale physics of collisionless space plasmas. Such ion-scale magnetospheres can be found on local regions of the Moon, associated with the lunar crustal magnetic field. In this paper, we report on the laboratory experimental study of magnetic reconnection in laser-driven, lunar-like ion-scale magnetospheres on the Large Plasma Device at the University of California, Los Angeles. In the experiment, a high-repetition rate (1 Hz), nanosecond laser is used to drive a fast-moving, collisionless plasma that expands into the field generated by a pulsed magnetic dipole embedded into a background plasma and magnetic field. The high-repetition rate enables the acquisition of time-resolved volumetric data of the magnetic and electric fields to characterize magnetic reconnection and calculate the reconnection rate. We notably observe the formation of Hall fields associated with reconnection. Particle-in-cell simulations reproducing the experimental results were performed to study the microphysics of the interaction. By analyzing the generalized Ohm’s law terms, we find that the electron-only reconnection is driven by kinetic effects through the electron pressure anisotropy. These results are compared to recent satellite measurements that found evidence of magnetic reconnection near the lunar surface.

Astronomy & Astrophysics↗

Power supply circuit with multiple stages for converting high voltage to low voltage and power train having the same

A power supply circuit for converting a first voltage to a second voltage where the first voltage is greater than the second voltage, and a power train having the same, are provided. The power supply circuit may have multiple stages and each stage of the power supply circuit may include a first circuit block configured to provide a start-up power to a second circuit block; a second circuit block configured to generate a Pulse-Width-Modulation (PWM) signal that controls a pulse duration of a transistor; a third circuit block configured to activate or deactivate the transistor based on the PWM signal; a fourth circuit block configured to reset a magnetic flux in a transformer to a zero state when the transistor is deactivated; and a fifth circuit block configured to maintain an output of a stage below a predetermined value by adjusting a voltage across the transformer.

Singh, Brij N.↗

Apparatus and methods of detecting transient discharge modes and/or closed loop control of pulsed systems and method employing same

A system and method for differentiating between different modes of pulsed electrical discharges via of an amplitude to time (ATC) conversion circuit is described. A bipolar ATC circuit is used to add together the positive and negative portions of an attenuated and filtered signal derived either from the voltage or current of a pulse. Alternatively, a unipolar ATC circuit may be employed. The resulting processed signal is compared against a reference voltage to generate an output signal that is active for the amount of time that the processed signal exceeds the reference voltage. Discharge mode is determined based on three factors: did a pulse occur, if a pulse occurred when did the pulse start relative to the original pulse event, and what is the duty cycle of the pulse. Subsequent pulse generated may be controlled accordingly.

Fitzpatrick, Joseph F.↗

Laser Based Ultrasound for Verification of Circuit Card Assemblies

This IR is a follow-up conference Paper to the IR approved abstract; PNNL-SA-194096. --- Verification that equipment is authentic and not changed; even at the circuit card assembly (CCA) level will likely be an important component of future arms control treaties. This effort was an initial evaluation of the potential for laser-based ultrasound (LBU) as an inspection tool for Unique Identification (UID) of Circuit Card Assembly (CCA) boards and CCA components. The LBU system used a laser pulse for ultrasound generation and an Optical Microphone for ultrasound detection to image subsurface structures without physical contact and in a dry state. This paper described the selected CCA surrogate, CCA components that were examined, the LBU system, LBU images of the CCA components, and the initial development of UID algorithms. Receiver operating characteristics (ROC) curves indicated good performance for two algorithms as a potential means for UID of CCA boards and CCA components.

Laser Ultrasound, Equipment Verification, Arms Con↗

Generation of a quasi-static magnetic field by a circularly polarised laser pulse due to tunnelling gas ionisation

We present a theoretical model of the quasi-static magnetic field generation in a laser channel, which is formed behind the front of a short laser pulse that ionises a gas. The generation of a magnetic field is caused by the appearance of the electron pressure anisotropy during tunnelling ionisation of atoms. In the considered case of subrelativistic laser light intensities, the generated magnetic field can reach ∼1 MG with an energy transformation ratio of about 1 %, which paves the way for identifying the proposed mechanism when use is made of a wide class of ultrashort pulse lasers. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Platform development for dE/dx measurements on short-pulse laser facilities

We illustrate generating benchmark data on charged-particle stopping power in dense plasma is a challenge, motivating new experimental platforms for facilities such as short-pulse lasers. We report on several experiments that aimed to develop a platform for high-precision stopping power measurements at OMEGA EP, specifically developing target-normal sheath acceleration (TNSA) sources, proton isochoric heating, and radiatively heated foams. Integrated experiments were performed to measure stopping power, but several phenomena have been identified that would need to be mitigated for a stopping-power measurement, including irreproducibility of the TNSA sources, spurious electromagnetic fields around proton-heated targets, and cross-talk between the source and subject targets. This work provides a basis for potential future work towards mitigating these problems and performing stopping-power measurements, and is also valuable data for general understanding of TNSA and proton isochoric heating experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power electrically tunable switch

A high-voltage switch, whose operation leverages the speed of electrons to generate the “on” time of the pulse in combination with the speed of light to generate the “off” time of the pulse, is described. In one example, the high-voltage switch includes a first electrode, a second electrode spaced apart from the first electrode, a region of non-absorbing material occupying a portion of the space between the first and second electrodes and allowing a laser pulse to propagate therethrough without substantial absorption, and a region of absorbing material occupying another portion of the space and producing a charged particle cloud upon receiving the laser pulse. The high-voltage switch remains “on” upon the charged particle cloud reaching an electrode and until it has been collected by the electrode, and where the high-voltage switch remains “off” subsequent to the collection and until another generated charged particle cloud reaches the electrode.

Voss, Lars↗

Dispersion Caused by the Penetration Effect in X-ray Compressors

Chirped X-ray pulse compression is a promising approach for generating ultra-short X-ray free electron laser (XFEL) pulses. The design of X-ray pulse compressors requires the careful control of group delay dispersion (GDD), which plays a critical role in achieving optimal compression. However, the penetration dispersion of crystals and multilayers can induce an extra GDD, which may result in over-compression or under-compression. In this study, we investigate the penetration dispersion of crystals and multilayers theoretically and numerically. Our results indicate that the extra GDD induced by the penetration effect increases as the bandwidth of the rocking curve decreases. Moreover, the extra GDD is nonlinear and can be mitigated by optimizing the configuration of X-ray pulse compressors. This work provides insights into the dispersion compensation and configuration optimization of X-ray pulse compressors, which are essential for generating ultra-short XFEL pulses.

47 OTHER INSTRUMENTATION↗

High-repetition rate, CEP-stable shortwave infrared source with two-cycle pulses for field-resolved spectroscopy

We report on a passively carrier-envelope phase (CEP)-stable optical parametric amplifier generating two-cycle pulses at 2060 nm with energies of up to 2.25 µJ operating at a repetition rate of 400 kHz, specifically designed for applications in field-resolved spectroscopy. The measured pulse duration is 13.6 fs, resulting in two cycles of the carrier wave. Due to the robust CEP-stable front-end design, we achieve an open-loop CEP stability of 250 mrad (rms) and the capability for fast CEP modulation.

47 OTHER INSTRUMENTATION↗

Generation of Intense Low-Divergence Isolated Soft-X-Ray Attosecond Pulses in a Gas-Filled Waveguide Using Three-Color Synthesized Laser Pulses

Isolated attosecond pulses (IAPs) in the soft-x-ray (SXR) region have been successfully produced via high-order harmonic generation in a gas medium at several laboratories, but pulse energies are much lower compared to the IAPs in the extreme ultraviolet. Here, we show that in a gas-filled hollow waveguide, an efficient gating method using a few-cycle three-color synthesizer is able to generate stronger SXR IAPs. We show that an 104-as IAP in the SXR region (central energy of 210 eV) with a higher pulse energy (0.9 nJ) and a lower divergence (within 1.5 mrad) can be generated with a three-color laser beam for input pulse energy at 0.62 mJ, under the condition of optimal gas pressure and waveguide length. The enhancement of the IAP is attributed to favorable phase matching of SXR high harmonics caused by the evolution of the three-color waveform during its propagation in the waveguide, which can be understood by analyzing the time shift of the waveform due to the interplay of the waveguide mode, atomic dispersion, and plasma dispersion. We check that the gating method is quite robust with respect to the phase jitter in the waveform. The advantage of this method is further demonstrated by comparing the generation of SXR high harmonics and attosecond pulses with two other schemes: the three-color waveform in a gas cell and a previously optimized two-color waveform in a gas-filled waveguide.

74 ATOMIC AND MOLECULAR PHYSICS↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗