Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Program Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oncology Navigation Decreases Time to Treatment in Patients with Pancreatic Malignancy

Background: Care of pancreatic cancer patients has become increasingly complex, which has led to delays in the initiation of therapy. Nurse navigators have been added to care teams, in part, to ameliorate this delay. This study investigated the difference in time from first oncology visit to first treatment date in patients with any pancreatic malignancy before and after the addition of an Oncology Navigator. Methods: A single-institution database of patients with any pancreatic neoplasm evaluated by a provider in radiation, medical, or surgical oncology between 1 October 2015 and 30 September 2017 was analyzed. After 1 October 2016, an Oncology Navigator met patients at their initial visit and coordinated care throughout treatment. The cohort was divided into two groups: patients evaluated prior to the implementation of an Oncology Navigator and patients evaluated after implementation. Patient demographics and time from first visit to first intervention were compared. Results: Overall, 147 patients with a new diagnosis of pancreatic neoplasm were evaluated; 57 patients were seen prior to the start of the Oncology Navigator program and 79 were evaluated after the navigation program was implemented. On univariate analysis, time from first contact by any provider to intervention was 46 days prior to oncology navigation and 26 days after implementation of oncology navigation (p = 0.005). While controlling for other covariates, employment of the Oncology Navigator decreased the time from first contact by any provider to intervention by almost 16 days (p = 0.009). Conclusions: Implementing an oncology navigation program significantly decreased time to treatment in patients with pancreatic malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Downlight LED Lighting Form-Factor Assessment

This report provides information about the evaluation of a field installation of a one-for-one Light Emitting Diode (LED) lamp replacement that uses the existing fluorescent ballast. The evaluation was part of a study conducted by Pacific Northwest National Laboratory (PNNL) for the Green Proving Ground program (GPG). The evaluation includes field-collected energy data, light-level data, and occupant and system installer survey responses. The report also provides recommendations based on the data collected during this field evaluation as well as other research-based sources, for applying this technology to other locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear Fuel Cycle Technologies: Current Challenges and Future Plans - 12558

The mission of the Office of Nuclear Energy's Fuel Cycle Technologies office (FCT program) is to provide options for possible future changes in national nuclear energy programs. While the recent draft report of the Blue Ribbon Commission on America's Nuclear Future stressed the need for organization changes, interim waste storage and the establishment of a permanent repository for nuclear waste management, it also recognized the potential value of alternate fuel cycles and recommended continued research and development in that area. With constrained budgets and great expectations, the current challenges are significant. The FCT program now performs R and D covering the entire fuel cycle. This broad R and D scope is a result of the assignment of new research and development (R and D) responsibilities to the Office of Nuclear Energy (NE), as well as reorganization within NE. This scope includes uranium extraction from seawater and uranium enrichment R and D, used nuclear fuel recycling technology, advanced fuel development, and a fresh look at a range of disposal geologies. Additionally, the FCT program performs the necessary systems analysis and screening of fuel cycle alternatives that will identify the most promising approaches and areas of technology gaps. Finally, the FCT program is responsible for a focused effort to consider features of fuel cycle technology in a way that promotes nonproliferation and security, such as Safeguards and Security by Design, and advanced monitoring and predictive modeling capabilities. This paper and presentation will provide an overview of the FCT program R and D scope and discuss plans to analyze fuel cycle options and support identified R and D priorities into the future. The FCT program is making progress in implanting a science based, engineering driven research and development program that is evaluating options for a sustainable fuel cycle in the U.S. Responding to the BRC recommendations, any resulting legislative changes, and meeting the needs of the commercial nuclear industry (including developing and evaluating fuel concepts that may enhance accident tolerance in light water reactors while possibly improving fuel performance) are program priorities. Continuing to build partnerships and collaborations with industry, universities, international organizations, and other DOE programs are essential to addressing the challenges facing the FCT program. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Roadmap to Achieve Energy Delivery Systems Cybersecurity

The Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) Cybersecurity for Energy Delivery Systems (CEDS) program is currently evaluating the Roadmap to Achieve Energy Delivery Systems Cybersecurity document that sets a vision and outlines a set of milestones. The milestones are divided into five strategic focus areas that include: 1. Build a Culture of Security; 2. Assess and Monitor Risk; 3. Develop and Implement New Protective Measures to Reduce Risk; 4. Manage Incidents; and 5. Sustain Security Improvements. The most current version of the roadmap was last updated in September of 2016. Sandia National Laboratories (SNL) has been tasked with revisiting the roadmap to update the current state of energy delivery systems cybersecurity protections. SNL is currently working with previous and current partners to provide feedback on which of the roadmap milestones have been met and to identify any preexisting or new gaps that are not addressed by the roadmap. The specific focus areas SNL was asked to evaluate are: 1. Develop and Implement New Protective Measures to Reduce Risk and 2. Sustain Security Improvements. SNL has formed an Industry Advisory Board (IAB) to assist in answering these questions. The IAB consists of previous partners on past CEDS funded efforts as well as new collaborators that have unique insights into the current state of cybersecurity within energy delivery systems. The IAB includes asset owners, utilities and vendors of control systems. SNL will continue to maintain regular communications with the IAB to provide various perspectives on potential future updates to further improve the breadth of cybersecurity coverage of the roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Evaluation Report for the Sandia National Laboratories Recorded Information Management Training Program

The Recorded Information Management (RIM) training and guidance materials were originally evaluated to determine the current status of the training program. Specifically, how and where are training materials implemented and are members of the workforce (MOWs) regularly accessing them. The evaluation highlighted that there is a breadth of training materials and guidance available; however, the materials are often outdated, point to old Sandia Policies, and/or are in outdated templates. Additionally, there is currently no single-entry point for training, meaning that training is available via the RIM homepage, TEDs, etc. This means that MOWs must search in various webpages or systems for training. To ensure RIM training materials are regularly updated and are accessible for MOWs it is recommended to assign one staff member to manage the program training materials.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Nuclear Data Verification and Standardization

The objective of this interagency program is to provide accurate neutron interaction verification and standardization data for the U.S. Department of Energy Division of Nuclear Physics programs which include astrophysics, radioactive beam studies, and heavy-ion reactions. The measurements made in this program are also useful to other programs that indirectly use the unique properties of the neutron for diagnostic and analytical purposes. These include homeland security, personnel health and safety, nuclear waste disposal, treaty verification, national defense, and nuclear based energy production. The work includes the verification of reference standard cross sections and related neutron data employing the unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; and the preservation of standard reference deposits. An essential element of the program is critical evaluation of neutron interaction data standards including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the 238 U PFNS Including Chi-Nu Experimental Data

This report documents an evaluation of 238 U prompt fission neutron spectra (PFNS) which is a deliverable for a FY2024 Q4 NCSP (Nuclear Criticality Safety Program) milestone. This evaluation is new; its prior input is based on extended Los Alamos and exciton models implemented in the code CoH. Experimental covariances were estimated for five experimental data sets. One of these data sets that was measured by the Chi-Nu team of LANL and LLNL. It covers the 238 U PFNS for continuous incident-neutron energies of 1–20 MeV and outgoing-neutron energies from 10 keV– 10 MeV with high precision. Contrary to Chi-Nu data, previous data sets were measured in a limited energy range. The resulting evaluated data correspond well to the experimental PFNS taken into account for the evaluation. The evaluated PFNS also produce average mean energies in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of the Flattop, Flattop-Pu and BigTen ICSBEP critical assemblies (which all have thick reflectors with high percentages of 238 U), the differences of simulated values compared to those using ENDF/B-VIII.1β3 is modest (less than 25 pcm). In addition to that, the new PFNS predict on average 238 U LLNL pulsed-sphere neutron-leakage spectra slightly better than ENDF/BVIIII.0 and ENDF/B-VIII.1β3 PFNS. The differences are, however, well within the experimental uncertainties.

238U↗

Results of Re-evaluation of FEPs Related to Implementing the ABD Glass Program

The Savannah River Site plans to reprocess defense spent nuclear fuel currently stored in their L-Basin via the Accelerated Basin Deinventory (ABD) Program. The previous plan for the L-Basin spent nuclear fuel was to dispose of it directly in the federal repository without reprocessing. Implementing the ABD Program will result in final disposal of approximately 900 fewer canisters of defense spent nuclear fuel and the production of approximately 521 more canisters of vitrified high-level waste glass with some specific differences from the planned high-level waste glass. Because the 235U in the L-Basin spent nuclear fuel is not intended to be recovered, the fissile mass loading of the vitrified high-level glass waste form to be produced must be increased above the current value of 897 g/m 3 to a maximum of 2,500 g/m 3 . Therefore, implementing the ABD Program would produce a variant of high-level waste glass—the ABD glass—that needs to be evaluated for future repository licensing, which includes both preclosure safety and postclosure performance. This report describes the approach to and summarizes the results of an evaluation of the potential effects of implementing the ABD Program at the Savannah River Site on the technical basis for future repository licensing for a generic repository that is similar to Yucca Mountain and for one that is fully generic. This evaluation includes the effects on preclosure safety analyses and postclosure performance assessment for both repository settings. The license application for the proposed Yucca Mountain repository (DOE 2008), which is serving as a framework for this evaluation, concluded that the proposed Yucca Mountain repository would meet all applicable regulatory requirements. The evaluation documented in this report found that implementing the ABD Program is not expected to change that conclusion for a generic repository similar to Yucca Mountain or for a generic repository with respect to the preclosure safety analyses. With respect to the postclosure performance of a generic repository, no concerns were identified.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The International Database of Efficient Appliances (IDEA): A new tool to support appliance energy-efficiency deployment

Appliance energy-efficiency programs are a central component of many countries’ energy-policy portfolios. A major barrier to optimal implementation of these programs is lack of data to determine market baselines, assess the potential for cost-effective energy savings, and track markets over time to evaluate and verify program impacts. To address this gap, we have developed the International Database of Efficient Appliances (IDEA), a suite of software tools that automatically gathers data that is currently dispersed across various online sources and compiles it into a unified repository of information on efficiency, price, and features for a diversity of appliances and devices in markets around the world. In this article we describe the framework and functionality of IDEA, and we demonstrate its power as a resource for research and policy development related to appliance energy efficiency. Using IDEA data for refrigerators in China and India, we assess the potential for cost-effective energy savings within each market by computing robust indicators that can also be easily compared across different appliances and markets. We find that significant cost-effective savings are available on both markets. We discuss implications for the development of future energy-efficiency deployment programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero-Emission Bus Evaluation Results: County Connection Battery Electric Buses

The U.S. Department of Transportation's (DOT's) Federal Transit Administration (FTA) supports the research, development, and demonstration of low- and zero-emission technology for transit buses. FTA funds research projects with a goal of facilitating commercialization of advanced technologies for transit buses that will increase efficiency and improve transit operations. DOT's Research, Development, and Technology Office (OST-R) also has an interest in zero-emission bus (ZEB) technology deployment and commercialization. OST-R is coordinating and collaborating with FTA on the evaluation process and results by providing funding to cover additional evaluations. FTA and OST-R are collaborating with the U.S. Department of Energy (DOE) and DOE's National Renewable Energy Laboratory (NREL) to conduct in-service evaluations of advanced technology buses developed under its programs. NREL uses a standard evaluation protocol for evaluating the advanced technologies deployed under the FTA programs. FTA seeks to provide results from new technologies being adopted by transit agencies. The eight evaluations selected to date include battery electric buses (BEBs) and fuel cell electric buses (FCEBs) from different manufacturers operating in fleets located in both cold and hot climates. The purpose of this report is to present the results from Central Contra Costa Transit Authority (County Connection) deployment of four BEBs in Concord, California. NREL's evaluation of the BEBs at County Connection was funded by OST-R.

33 ADVANCED PROPULSION SYSTEMS↗

Developing Equivalent Surface Heat Transfer Input Parameters for Updated Standard 140/BESTEST Thermal Fabric Test Cases

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, is widely cited for evaluating software for use with performance-path energy efficiency analysis in conjunction with well-known energy-efficiency standards, including: ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. This paper summarizes recent work to develop improved equivalent surface heat transfer input parameters for the building thermal fabric comparative test cases that comprise a portion of Standard 140. The software-to-software comparative test method allows comparison of simulation results from a wide variety of building energy simulation programs to each other. In this type of test method, it is of great importance to specify inputs that are as well-equivalenced as possible to accommodate a wide variety of input schemes for the tested programs, and thereby reduce the potential for disagreements among them in the tests. Results include new alternative constant surface coefficients that are appropriate to the test cases and demonstrate their ability to approximate the more detailed surface heat transfer models from which they are derived.

BESTEST↗

SU-E-T-434: Evaluation of the Machine Performance Check (MPC) Program for Truebeam 2.0

Purpose: Machine Performance Check (MPC) is a software application used to verify that the TrueBeam machine is operating within major specifications prior to treatment. Used in combination with a phantom named Isocal, it verifies beam output, beam uniformity, treatment isocenter size, coincidence of treatment and imaging isocenters, positioning accuracy of kV and MV imaging systems, accuracy of collimator and gantry rotation angle, positioning accuracy of jaws and MLC leafs, and couch positioning. The tests can be performed semi-automatically and requires approximately 10 minutes of machine time. It is the purpose of this study to report the performance of this program. Methods: A pre-release version of the MPC tool was installed on a Truebeam linac with 6D couch at our center. Baseline beam output measurements were taken for 5 photon beams (6–15 MV, 6 FFF, 10 FFF) and 5 electron beams (6–20 MeV). Deviations from the baseline output were subsequently recorded for several days and compared against independent measurements from a PTW farmer chamber and our daily QA device (Fluke Biomedical Tracker) as part of an ongoing evaluation. Results: The beam output deviations between the MPC and the PTW chamber measurements were within ±0.7% for photons beams and ±1.0% for electrons beams. This was similar to the tracker performance. There were some isolated incidents where the MPC measurements had unexplained spikes (>3%) that disappeared on a repeat measurement. MPC was also able to detect maximum positioning errors in the jaws (1.12 mm), MLCs (1.14 mm), and couch roll (0.11°). Conclusion: Overall, the ability of the MPC to monitor linac output stability was comparable to that of ionization chamber-based measurements. MPC also provided fast daily mechanical tests not currently available in the clinic. How best to utilize this previously unavailable data is still under investigation.

07 ISOTOPE AND RADIATION SOURCES↗