Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Deployment of large tank monosodium titanate strike to increase salt processing at the Savannah river site - 15115

The treatment of high level waste (HLW) salt solutions using the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU) began at Savannah River Site (SRS) in 2008. Since that time, over 6 million gallons of liquid HLW have been treated and the resulting low level waste (LLW) effluent immobilized in cementitious grout at salt-stone. In addition to the continued stabilization of liquid HLW, operating experience from the ARP/MCU facilities has also been valuable in considering the design and construction of the Salt Waste Processing Facility (SWPF) which will utilize similar unit operations on a much larger scale. ARP removes actinides by contacting waste with monosodium titanate (MST) which is a solid adsorbent for soluble strontium and actinides. Once the sorption reaction is complete, the MST solids are separated from salt solution via ultrafiltration through a crossflow filter. The throughput of initial operations of ARP/MCU was limited by the flowrate through the extraction process. However, after the implementation of a new solvent flowsheet, filtration of MST will be the rate limiting step in salt processing. For the entirety of ARP/MCU operation, Savannah River Remediation (SRR) has sought to improve process efficiency and performance through optimization and modification of the original facility design. These efforts have resulted in a best-single-year throughput of 4.9 million liters of decontaminated salt solution. In keeping with these practices, SRR recently initiated a project to improve filtration throughput by relocating the MST strike from small batches immediately upstream of the filtration unit to the underground waste tank used to batch and store salt solution feed for ARP/MCU. This process change will allow the bulk of MST solids to decant in the waste tank prior to filtration which should improve both the nominal operational filter flux as well as the achieved utility of filter operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance analysis of data intensive cloud systems based on data management and replication: a survey

As we delve deeper into the ‘Digital Age’, we witness an explosive growth in the volume, velocity, and variety of the data available on the Internet. For example, in 2012 about 2.5 quintillion bytes of data was created on a daily basis that originated from myriad of sources and applications including mobiledevices, sensors, individual archives, social networks, Internet of Things, enterprises, cameras, software logs, etc. Such ‘Data Explosions’ has led to one of the most challenging research issues of the current Information and Communication Technology era: how to optimally manage (e.g., store, replicated, filter, and the like) such large amount of data and identify new ways to analyze large amounts of data for unlocking information. It is clear that such large data streams cannot be managed by setting up on-premises enterprise database systems as it leads to a large up-front cost in buying and administering the hardware and software systems. Therefore, next generation data management systems must be deployed on cloud. The cloud computing paradigm provides scalable and elastic resources, such as data and services accessible over the Internet Every Cloud Service Provider must assure that data is efficiently processed and distributed in a way that does not compromise end-users’ Quality of Service (QoS) in terms of data availability, data search delay, data analysis delay, and the like. In the aforementioned perspective, data replication is used in the cloud for improving the performance (e.g., read and write delay) of applications that access data. Through replication a data intensive application or system can achieve high availability, better fault tolerance, and data recovery. In this paper, we survey data management and replication approaches (from 2007 to 2011) that are developed by both industrial and research communities. The focus of the survey is to discuss and characterize the existing approaches of data replication and management that tackle the resource usage and QoS provisioning with different levels of efficiencies. Moreover, the breakdown of both influential expressions (data replication and management) to provide different QoS attributes is deliberated. Furthermore, the performance advantages and disadvantages of data replication and management approaches in the cloud computing environments are analyzed. Open issues and future challenges related to data consistency, scalability, load balancing, processing and placement are also reported.

Malik, Saif Ur Rehman↗

Data and Code for: Observation-constrained agroecosystem model inversion reveals continental-scale variation of winter wheat traits

This repository contains the simulation outputs and processing scripts associated with the study of winter wheat traits across the United States, utilizing the Ecosys agroecosystem model. The dataset includes model results for both rainfed and irrigated winter wheat systems, supporting the findings presented in the manuscript titled "Observation-constrained agroecosystem model inversion reveals continental-scale variation of winter wheat traits." Data includes the original Ecosys simulation outputs (archived in .db format within the compressed .zip files) and extracted analysis data (stored in .pkl files for efficient processing). Python code for data processing and figure generation is provided in a Jupyter notebook. External Observational Datasets should refer to the following official repositories for the input and validation data used in this study. The eddy covariance data from the AmeriFlux network (https://ameriflux.lbl.gov/). Climate-forcing data of NLDAS-2 from NASA LDAS (https://ldas.gsfc.nasa.gov/nldas/nldas-2-forcing-data). Soil data from the Gridded Soil Survey Geographic Database (gSSURGO), available at (https://www.nrcs.usda.gov/resources/data-and-reports/gridded-soil-survey-geographic-gssurgo-database). Crop yields, planting and harvest dates from the USDA public databases (https://quickstats.nass.usda.gov/; https://webapp.rma.usda.gov/apps/actuarialinformationbrowser/CropCriteria.aspx). Satellite-derived SLOPE GPP data from ORNL DAAC (https://daac.ornl.gov/cgi-bin/dsviewer.pl?ds_id=1786). Land use and crop progress information from the USDA Crop Data Layer and Crop Progress and Condition Gridded Layers (https://www.nass.usda.gov/Research_and_Science/). The Ecosys model code is available online at https://github.com/jinyun1tang/ECOSYS.

Wheat↗

Cost studies for commercial fuselage crown designs

Studies were conducted to evaluate the cost and weight potential of advanced composite design concepts in the crown region of a commercial transport. Two designs from each of three design families were developed using an integrated design-build team. A range of design concepts and manufacturing processes were included to allow isolation and comparison of cost centers. Detailed manufacturing/assembly plans were developed as the basis for cost estimates. Each of the six designs was found to have advantages over the 1995 aluminum benchmark in cost and weight trade studies. Large quadrant panels and cobonded frames were found to save significant assembly labor costs. Comparisons of high- and intermediate-performance fiber systems were made for skin and stringer applications. Advanced tow placement was found to be an efficient process for skin lay up. Further analysis revealed attractive processes for stringers and frames. Optimized designs were informally developed for each design family, combining the most attractive concepts and processes within that family. A single optimized design was selected as the most promising, and the potential for further optimization was estimated. Technical issues and barriers were identified.

Walker, T. H.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chemical structure and curing dynamics of bisphenol S, PEEK™-like, and resveratrol phthalonitrile thermoset resins

This effort provides a multifaceted analysis of the structural changes and material dynamics of thermally driven softening and curing of three distinct phthalonitrile (PN) resins that cross-link into thermally stable and oxidation-resistant thermosets. Although this material system has yielded a large subset of fire-retardant composites that require facile processing and low-temperature curing, to date, insufficient information had been available on the fundamental processes that drive their softening and curing stages. Our approach conducted a complementary analysis the chemistry, monomer mobility, and rheology of three PN polymers in order to correlate the curing processes with corresponding structural and behavioral transformations of thermosets. Here, we focused on PNs with a bisphenol S backbone, a bisphenol A (PEEK™-like) backbone, and a resveratrol backbone. We relied on quasi-elastic neutron scattering (QENS) in order to analyze the in situ dynamics and self-diffusion properties of PN monomers, and to track changes in their mobilities during cross-linking and staging. Our analysis facilitates proper control over the staging and final curing of these resins and enables more efficient processing of these thermosets.

36 MATERIALS SCIENCE↗

An intelligent advisory system for pre-launch processing

The shuttle system of interest in this paper is the shuttle's data processing system (DPS). The DPS is composed of the following: (1) general purpose computers (GPC); (2) a multifunction CRT display system (MCDS); (3) mass memory units (MMU); and (4) a multiplexer/demultiplexer (MDM) and related software. In order to ensure the correct functioning of shuttle systems, some level of automatic error detection has been incorporated into all shuttle systems. For the DPS, error detection equipment has been incorporated into all of its subsystems. The automated diagnostic system, (MCDS) diagnostic tool, that aids in a more efficient processing of the DPS is described.

Engrand, Peter A.↗

Decontamination of Nuclear Liquid Wastes Status of CEA and AREVA R and D: Application to Fukushima Waste Waters - 12312

Liquid wastes decontamination processes are mainly based on two techniques: Bulk processes and the so called Cartridges processes. The first technique has been developed for the French nuclear fuel reprocessing industry since the 60's in Marcoule and La Hague. It is a proven and mature technology which has been successfully and quickly implemented by AREVA at Fukushima site for the processing of contaminated waters. The second technique, involving cartridges processes, offers new opportunities for the use of innovative adsorbents. The AREVA process developed for Fukushima and some results obtained on site will be presented as well as laboratory scale results obtained in CEA laboratories. Examples of new adsorbents development for liquid wastes decontamination are also given. A chemical process unit based on co-precipitation technique has been successfully and quickly implemented by AREVA at Fukushima site for the processing of contaminated waters. The asset of this technique is its ability to process large volumes in a continuous mode. Several chemical products can be used to address specific radioelements such as: Cs, Sr, Ru. Its drawback is the production of sludge (about 1% in volume of initial liquid volume). CEA developed strategies to model the co-precipitation phenomena in order to firstly minimize the quantity of added chemical reactants and secondly, minimize the size of co-precipitation units. We are on the way to design compact units that could be mobilized very quickly and efficiently in case of an accidental situation. Addressing the problem of sludge conditioning, cementation appears to be a very attractive solution. Fukushima accident has focused attention on optimizations that should be taken into account in future studies: - To better take account for non-typical aqueous matrixes like seawater; - To enlarge the spectrum of radioelements that can be efficiently processed and especially short lives radioelements that are usually less present in standard effluents resulting from nuclear activities; - To develop reversible solid adsorbents for cartridge-type applications in order to minimize wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

Fast synchronization-free algorithms for parallel sparse triangular solves with multiple right-hand sides

The sparse triangular solve kernels, SpTRSV and SpTRSM, are important building blocks for a number of numerical linear algebra routines. Parallelizing SpTRSV and SpTRSM on today's many-core platforms, such as GPUs, is not an easy task since computing a component of the solution may depend on previously computed components, enforcing a degree of sequential processing. As a consequence, most existing work introduces a preprocessing stage to partition the components into a group of level-sets or colour-sets so that components within a set are independent and can be processed simultaneously during the subsequent solution stage. However, this class of methods requires a long preprocessing time as well as significant runtime synchronization over-heads between the sets. To address this, we

HPC↗

Portable Parallel Algorithms and Frameworks for Exascale Graph Analytics

Graphs (or networks) are a tool used to model the interactions among various entities. Efficiently processing large graphs has recently attracted significant attention due to the applications of graphs in various domains, such as biology, chemistry, and cyber-security. Analyzing the structure and properties of these graphs is an important component of many scientific computing pipelines. With the explosion in the volume of data, graphs have become very large and can contain hundreds of billions of vertices and trillions of edges. Therefore, it is crucial to develop high-performance methods to enable graph analysis to be done quickly and energy-efficiently. Furthermore, these solutions should be highly parallel in order to take advantage of modern parallel machines. However, designing efficient solutions is not enough. With the wide variety of computing environments available, each with different programmability and performance characteristics, it is necessary to develop solutions that are portable in terms of both performance (i.e., provide theoretical guarantees) and programmability (i.e., provide high level abstractions).

97 MATHEMATICS AND COMPUTING↗

Opportunities and Challenges for Water and Wastewater Industries to Provide Exchangeable Services

Water and wastewater treatment plants and distribution systems use significant amounts of energy, around 2 - 4% of the total electricity used in the US, and their energy use is projected to increase as populations increase and regulations become more stringent. Water and wastewater systems have largely been disconnected from the electric utilities' efforts to improve energy efficiency and provide energy efficiency and provide grid services, likely because their core mission is to provide clean water and treated wastewater. Energy efficiency has slowly crept into the water and wastewater industry as the economic benefit has become more apparent, but there is still potential for significant improvement. Some of the larger, more progressive water utilities are starting to consider providing grid services; however, it remains a foreign concept to many. This report explores intrinsic mechanisms by which the water and wastewater industries can provide exchangeable services, the benefit to the parties involved, and the barriers to implementation. It also highlights relevant case studies and next steps. Although opportunities for increasing process efficiencies are certainly available, this report focuses on the exchangeable services that water and wastewater loads can provide to help maintain grid reliability, keep overall costs down, and increase the penetration of distributed renewables on the electric grid. These services have potential to provide water utilities additional value streams, using existing equipment with modest or negligible upgrade cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic analysis of cascade microcryocoolers with low pressure ratios

The vapor-compression cycle for refrigeration near ambient temperature achieves high efficiency because the isenthalpic expansion of the condensed liquid is a rather efficient process. However, temperatures are limited to about 200 K with a single-stage system. Temperatures down to 77 K are possible with many stages. In the case of microcryocoolers using microcompressors, pressure ratios are usually limited to about 6 or less. As a result, even more stages are required to reach 77 K. If the microcompressors can be fabricated with low-cost wafer-level techniques, then the use of many stages with separate compressors may become a viable option for achieving temperatures of 77 K with high efficiency. We analyze the ideal thermodynamic efficiency of a cascade Joule-Thomson system for various temperatures down to 77 K and with low pressure ratios. About nine stages are required for 77 K, but fewer stages are also analyzed for operation at higher temperatures. For 77 K, an ideal second-law efficiency of 83 % of Carnot is possible with perfect recuperative heat exchangers and 65 % of Carnot is possible with no recuperative heat exchangers. The results are compared with calculated efficiencies in mixed-refrigerant cryocoolers over the range of 77 K to 200 K. Refrigeration at intermediate temperatures is also available. The use of single-component fluids in each of the stages is expected to eliminate the problem of pulsating flow and temperature oscillations experienced in microcryocoolers using mixed refrigerants.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commissioning of a GeoMelt Vitrification Plant at the Central Laboratory on the Sellafield Site - 17561

The National Nuclear Laboratory (NNL) and Kurion Veolia (Kurion) have installed a GeoMelt{sup R} In-Container Vitrification (ICV){sup R} radioactive waste treatment system in the Central Laboratory Active Rig Hall at Sellafield. This installation was completed in 2016. GeoMelt incorporates a range of patented and proprietary vitrification processing technologies that are configured in a variety of ways depending on the project and the waste. GeoMelt transforms hazardous chemical and radioactive wastes into an inert vitreous monolith. Hazardous organics are destroyed by pyrolysis and heavy metals and radionuclides are immobilized within the glass matrix where they are not preferentially leached into the environment. GeoMelt IVC produces a durable wasteform for a large variety of input wastes. The batch nature of the process which involves single-use refractory offers a wide range of process benefits over traditional vitrification technologies including: - a wide range of waste chemistries allowing high waste loadings; - compatibility with heterogeneous wastes including wastes with high metal content; - a technological simple solution without stirrers, bubblers, etc.; - No refractory corrosion concerns or melter drain failure scenarios; - Flexibility in glass chemistry and melter/disposal container configuration allows the wasteform to be specifically tailored to the storage or disposal site requirements. As part of the 2016 system commissioning at NNL's Central Laboratory, three demonstration melts were performed, one funded by Sellafield Ltd. and two by the Nuclear Decommissioning Authority (NDA). The first melt processed inactive soil with an inactive caesium tracer. The second melt processed inactive soil with a Cs-137 tracer. The third melt processed active waste soil from a variety of NDA nuclear licensed sites. The work conducted during commissioning was multi-purpose; it successfully demonstrated the benefits that the GeoMelt technology could bring to the UK NDA estate while performing equipment testing/troubleshooting and operator training. A significant benefit of the GeoMelt ICV technology is volume reduction for wastes which would otherwise experience a volume increase if encapsulated. Another benefit is the ability to treat difficult radioactive waste streams not amenable to encapsulation (e.g., reactive and/or organic wastes) with a very low energy consumption. The purpose of the first commissioning melt, Plant Performance Demonstration (PPD)-1, was to operate the GeoMelt system under typical conditions and to perform a post-melt mass balance of the caesium as a surrogate for Cs-137 in order to access retention of caesium in the final glass product. The melt processed a mixture of inactive soil obtained near the Sellafield site (as analogue for contaminated Sellafield soil), additives, and glass frit. An inactive caesium tracer was added to this melt as Cs{sub 2}CO{sub 3}. The purpose of the second commissioning melt, PPD-2, was to operate the GeoMelt system under typical conditions and to perform a post-melt activity balance using a Cs-137 tracer in order to assess retention of Cs-137 in the final glass product. Materials processed were inactive soil, glass frit, additives, and a radioactive caesium tracer (CsCl). The purpose of the third melt, Experiment-1 (EX-1) was to treat active waste and inactive waste simulant, as a demonstration of simultaneous processing of multiple waste streams. EX-1 consisted of processing active soil, Magnox sludge simulant, inactive soil, additives, and frit. The active soil used for this melt was obtained from the Hunterston A, Bradwell, Capenhurst, and Sellafield nuclear licensed sites. Since most soils are high in silica, the concept for this experiment was to use the active soils to provide glass formers while co-processing Magnox sludge simulant which does not contain glass formers. Beyond demonstration of capability areas of focus of this series of demonstrations included processing efficiency (kWh/kg treated) and caesium retention (%). This paper summarizes operations and results of the three melts. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring the Science Trade Space with the JPL Innovation Foundry A-Team

The JPL Innovation Foundry has established a new approach for exploring, developing, and evaluating early concepts with a group called the Architecture Team (A-Team). The A-Team combines innovative collaborative methods and facilitated sessions with subject matter experts and analysis tools to help mature mission concepts. Science, implementation, and programmatic elements are all considered during an ATeam study. In these studies, Concept Maturity Levels (CML) are used to group methods. These levels include idea generation and capture (CML 1), initial feasibility assessment (CML 2), and trade space exploration (CML 3). Methods used for exploring the science objectives, feasibility, and scope will be described including use of a new technique for understanding the most compelling science, called a Science Return Diagram (SRD). In the process of developing the SRD, gradients in the science trade space are uncovered along with their implications for implementation and mission architecture. Special attention is paid towards developing complete investigations, establishing a series of logical claims that lead to the natural selection of a measurement approach. Over 20 science-focused A-Team studies have used these techniques to help science teams refine their mission objectives, make implementation decisions and reveal the mission concept’s most compelling science. This paper will describe the A-Team process for exploring the mission concept's science trade space and the Science Return Diagram technique.In June of 2011 a new collaborative engineering approach forearly concept formulation began in the JPL InnovationFoundry [1], six months later becoming the “A-Team” [2].Responding to a need for exploring mission architecturelevel trades [3], the A-Team precedes Team X [4,5] in asequence of concurrent engineering teams at JPL that can beused to mature a concept from a “cocktail napkin” level ideato a complete mission point design. The A-Team efficientlyexplores the science, implementation, and programmatictrade space in early concept formulation. Small, facilitatedgroups of experts generate innovative ideas, quantitativelyassess feasibility, and discover key sensitivities in the tradespace through collaborative analysis and use of advancedmethods and tools. The A-Team process builds off theexperience within JPL and other recent approaches to earlyconcept formulation [6] including best practices of the JPLInnovation Foundry, Project Systems Engineering &Formulation Section, Team Eureka and the Rapid MissionArchitecture Team[7].The A-Team is a focal point for innovative formulationapproaches and people within JPL. It relies on a largebackground of study resources, creative thinkers and “greybeard” scrutinizers, advanced tools, and subject matterexperts with both breadth and depth in experience andexpertise that are all available at JPL. The A-Team isdesigned to be a rapid and efficient process takingapproximately 6 weeks (the entire process can be as short asjust a few days or as long as up to three months) and costingthe equivalent of a work-month of a full-time employee orless. Studies begin with detailed planning and client reviewfollowed by study sessions, analysis work, and reporting.The staffing on each study is customized to the study goalsand objectives, and it is addressed early in the A-Teamprocess. Sessions are generally half-day or whole-day eventsand conducted over a series of days with focused agendas thatare moderated by a trained facilitator. Preliminary results andknowledge capture are available within hours of each session,and a final report is generally available two weeks later.One of the biggest challenges facing early conceptdevelopment is understanding the gradient in science returnversus various available mission scenarios and payload options. Often times, major areas of scientific inquiry havealready been prioritized by science groups, including throughthe National Research Council’s Decadal Studies inAstronomy, Planetary, and Earth Science. Yet science teamscontinue to struggle, especially in competitive missionsolicitations, to capture the right amount of scope that’sachievable within the cost constraints of the opportunity.Often the desire to completely and comprehensively study ascience area in just one mission (after all, true missionopportunities are rare) drives teams to take on too much,providing requirements that are unachievable within theresources of the opportunity without inducing unacceptableimplementation risk. Alternatively, science teams can seekto reduce risk by using an established instrument, but havenot thought through the traceability and key aspects of thescience question to justify its use. Both scenarios lead to badassumptions at the beginning of the concept development thatcan then ripple through implementation option choices,potentially preventing what would have been a good scienceinvestigation from being selected.The purpose of this paper is first to provide some additionalbackground and summary of the A-Team process, tools,people, and facilities. We then focus on the A-Teammethodology for overcoming the barriers of defining thescience scope well at the early concept development stage.This includes understanding the science story andtraceability, and then examining the gradient in science returnversus key characteristics of observables, developing theright payload and mission requirement specification throughexamining the science and implementation trade space.

Ziemer, John K.↗

Non-Equilibrium Actinide Radiation Chemistry and the Nuclear Fuel Cycle

Actinides are inherently unstable elements that frequently coexist with other radioisotopes, generating intense ionizing radiation fields that drive the formation of non equilibrium oxidation states. These transient species exert a profound mechanistic influence on the radiation response of actinide containing systems due to their unique redox chemistry. Despite their importance, they remain poorly understood, yet such insight is essential for advancing actinide science and accurately predicting radiation driven behavior. Actinide separations—critical for nuclear energy technologies, strategic deterrence, space exploration, and nuclear medicine—depend on precise control of actinide oxidation states to recover targeted elements from complex matrices such as used nuclear fuel. However, during these processes, actinides, their coordination complexes, and the separation media are all exposed to intense, multicomponent (alpha, beta, gamma, etc.) radiation fields that can alter process efficiency, selectivity, and chemical stability. Understanding, controlling, and mitigating radiation induced reactions is therefore key to innovating and optimizing next generation separation technologies. This seminar will provide an overview of the nuclear fuel cycle and non equilibrium actinide radiation chemistry in the context of recovering actinides from used nuclear fuel, with a particular emphasis on direct dissolution–based reprocessing strategies. We will explore time resolved electron pulse radiolysis and alpha and gamma dose accumulation studies, integrated with multiscale computational modeling, to elucidate the molecular level roles of radiation driven, non equilibrium actinide species in process performance and in the radiolytic stability of organic ligands used for actinide recovery. These insights offer new pathways for designing advanced separation methods and next generation solvent systems, with broad implications for the future of the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Non-Equilibrium Actinide Radiation Chemistry and the Nuclear Fuel Cycle

Invited John and Naomi Fackler Lectureship in Chemistry and English seminar at Valparaiso University, IN, USA. Actinides are inherently unstable elements that frequently coexist with other radioisotopes, generating intense ionizing radiation fields that drive the formation of non-equilibrium oxidation states. These transient species exert a profound mechanistic influence on the radiation response of actinide-containing systems due to their unique redox chemistry. Despite their importance, they remain poorly understood, yet such insight is essential for advancing actinide science and accurately predicting radiation-driven behavior. Actinide separations—critical for nuclear energy technologies, strategic deterrence, space exploration, and nuclear medicine—depend on precise control of actinide oxidation states to recover targeted elements from complex matrices such as used nuclear fuel. However, during these processes, actinides, their coordination complexes, and the separation media are all exposed to intense, multicomponent (alpha, beta, gamma, etc.) radiation fields that can alter process efficiency, selectivity, and chemical stability. Understanding, controlling, and mitigating radiation-induced reactions is therefore key to innovating and optimizing next-generation separation technologies. This seminar will provide an overview of the nuclear fuel cycle and non-equilibrium actinide radiation chemistry in the context of recovering actinides from used nuclear fuel, with a particular emphasis on direct-dissolution–based reprocessing strategies. We will explore time-resolved electron pulse radiolysis and gamma dose accumulation studies to elucidate the molecular-level roles of radiation-driven, non-equilibrium actinide species in process performance and in the radiolytic stability of organic ligands used for actinide recovery. These insights offer new pathways for designing advanced separation methods and next-generation solvent systems, with broad implications for the future of the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Proton Radiography Peers into Metal Solidification

Historically, metals are cut up and polished to see the structure and to infer how processing influences the evolution. We can now peer into a metal during processing without destroying it using proton radiography. Understanding the link between processing and structure is important because structure profoundly affects the properties of engineering materials. Synchrotron x-ray radiography has enabled real-time glimpses into metal solidification. However, x-ray energies favor the examination of small volumes and low density metals. In this study, we use high energy proton radiography for the first time to image a large metal volume (>10,000 mm 3 ) during melting and solidification. We also show complementary x-ray results from a small volume (<1mm 3 ), bridging four orders of magnitude. In conclusion, real-time imaging will enable efficient process development and the control of the structure evolution to make materials with intended properties; it will also permit the development of experimentally informed, predictive structure and process models.

36 MATERIALS SCIENCE↗