Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Measuring the Exciton Binding Energy: Learning from a Decade of Measurements on Halide Perovskites and Transition Metal Dichalcogenides

The exciton binding energy ( E b ) is a key parameter that governs the physics of many optoelectronic devices. At their best, trustworthy and precise measurements of E b challenge theoreticians to refine models, are a driving force in advancing the understanding of a material system, and lead to efficient device design. At their worst, inaccurate E b measurements lead theoreticians astray, sow confusion within the research community, and hinder device improvements by leading to poor designs. Here, this review article seeks to highlight the pros and cons of different measurement techniques used to determine E b , namely, temperature‐dependent photoluminescence, resolving Rydberg states, electroabsorption, magnetoabsorption, scanning tunneling spectroscopy, and fitting the optical absorption. Due to numerous conflicting E b values reported for halide perovskites (HP) and transition metal dichalcogenides (TMDC) monolayers, an emphasis is placed on highlighting these measurements in an attempt to reconcile the variance between different measurement techniques. It is argued that the experiments with the clearest indicators are in agreement on the following values: ≈350–450 meV for TMDC monolayers between SiO 2 and vacuum, ≈150–200 meV for hBN‐encapsulated TMDC monolayers, ≈200–300 meV for common lead‐iodide 2D HPs, and ≈10 meV for methylammonium lead iodide.

36 MATERIALS SCIENCE↗

HOD-dependent systematics in Emission Line Galaxies for the DESI 2024 BAO analysis

The Dark Energy Spectroscopic Instrument (DESI) will provide precise measurements of Baryon Acoustic Oscillations (BAO) to constrain the expansion history of the Universe and set stringent constraints on dark energy. Therefore, precise control of the global error budget due to various systematic effects is required for the DESI 2024 BAO analysis. In this work, we estimate the level of systematics induced in the DESI BAO analysis due the assumed Halo Occupation Distribution (HOD) model for the Emission Line Galaxy (ELG) tracer. We make use of mock galaxy catalogs constructed by fitting various HOD models to early DESI data, namely the One-Percent survey data. Our analysis includes typical HOD models for the ELG tracer used in the literature as well as extensions to the baseline models. Among the extensions, we consider various recipes for galactic conformity and assembly bias. We use 25 AbacusSummit simulations under the ΛCDM cosmology for each HOD model and perform independent analyses in Fourier space and in configuration space. To recover the BAO signal from our mocks we perform BAO reconstruction and apply the control variates technique to reduce sample variance noise. Our BAO analyses can recover the isotropic BAO parameter α iso within 0.1% and the Alcock Paczynski parameter α AP within 0.3%. Overall, we find that the systematic error due to the HOD dependence is below 0.17%, with the Fourier space analysis being more robust against the HOD systematics. We conclude that our analysis pipeline is robust enough against the HOD systematics for the ELG tracer in the DESI 2024 BAO analysis, for the assumptions made.

79 ASTRONOMY AND ASTROPHYSICS↗

New NOvA Results with 10 Years of Data

NOvA is a two-detector accelerator neutrino oscillation experiment. Using Fermilab's newly Megawatt-capable NuMI neutrino beam, NOvA measures the disappearance of muon (anti)neutrinos and the appearance of electron (anti)neutrinos at the far detector, 810 km from the source. These oscillations are observed relative to the unoscillated beam composition measured at the functionally equivalent near detector, also located at Fermilab, which enables significant cancellation of systematic uncertainties. From these, we obtain precision measurements of the larger neutrino mass splitting and the largest neutrino mixing angle, as well as constraints on the octant of that angle, the neutrino mass ordering, and neutrino CP violation. In this talk I will present new measurements of these parameters using 10 years of NOvA data collected between 2013 and 2023, which includes twice the neutrino-mode exposure of our previous results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Model-Agnostic Exploration of the Mass Reach of Precision Higgs Boson Coupling Measurements

To understand the possibility for precision Higgs boson coupling measurements to access effects of very heavy new particles, I present five scenarios in which significant deviations in Higgs boson couplings are produced by new particles with multi-TeV masses. These scenarios indicate that such precision measurements provide opportunities to reach well beyond the capabilities of direct particle searches at the HL-LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observable optimization for precision theory: machine learning energy correlators

The practice of collider physics typically involves the marginalization of multi-dimensional collider data to uni-dimensional observables relevant for some physics task. In many cases, such as classification or anomaly detection, the observable can be arbitrarily complicated, such as the output of a neural network. However, for precision measurements, the observable must correspond to something computable systematically beyond the level of current simulation tools. In this work, we demonstrate that precision-theory-compatible observable space exploration can be systematized by using neural simulation-based inference techniques from machine learning. We illustrate this approach by exploring the space of marginalizations of the energy 3-point correlator to optimize sensitivity to the top quark mass. We first learn the energy-weighted probability density from simulation, then search in the space of marginalizations for an optimal triangle shape. Although simulations and machine learning are used in the process of observable optimization, the output is an observable definition which can be then computed to high precision and compared directly to data without any memory of the computations which produced it. We find that the optimal marginalization is isosceles triangles on the sphere with a side ratio approximately $1 : 1 : \sqrt{2}$ (i.e. right triangles) within the set of marginalizations we consider.

Jets and Jet Substructure↗

Demonstration of active neutron interrogation of special nuclear materials using a high-intensity short-pulse-laser-driven neutron source

Detecting shielded special nuclear material, such as nuclear explosives, is a difficult challenge pursued by non-proliferation, anti-terrorism, and nuclear security programs worldwide. Interrogation with intense fast-neutron pulses is a promising method to characterize concealed nuclear material rapidly but is limited by suitable source availability and proven instrumentation. In this study we have pioneered a demonstration of such an interrogation method using a high-intensity, short-pulse, laser-driven neutron source that offers potential benefits compared to conventional neutron sources. The measurement results reported here represent the first experimental demonstration of this interrogation approach on enriched uranium items and demonstrate the feasibility of a precise measurement using realistic nuclear materials, representative of field scenarios, even with just a single laser-driven neutron pulse. Bright pulsed sources can overcome the nuisance background of items with strong internal neutron sources, improving analytical power, while single-shot assay is attractive in high-throughput situations where time is at a premium. The science and technology of this type of neutron production is developing rapidly, and we anticipate that practical mobile interrogation systems will become available based on the detection concepts demonstrated here to meet the growing measurement needs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An overview of new measurements of flow, chirality and vorticity from STAR experiment

In relativistic heavy-ion collisions, the properties of quark–gluon plasma (QGP) and complex dynamics of multi-scale processes in Quantum Chromodynamics (QCD) are studied by analyzing the final state produced particles in a variety of different ways. In these proceedings, we present an overview of new detailed measurements of flow, chirality and vorticity by the STAR experiment at Relativistic Heavy Ion Collider (RHIC). Furthermore, STAR’s future opportunities for the precision measurements on small systems, fixed-target (FXT) mode, and Beam Energy Scan (BES-II) program are discussed.

Physics↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interfacial Effects on Transport Coefficient Measurements in Li-ion Battery Electrolytes

Development of Li + -containing electrolytes with improved transport properties requires reliable, reproducible, and ideally low volume techniques to rigorously understand ion-transport with varying composition. Precisely measuring the complete set of transport coefficients in liquid electrolytes under battery-relevant operating conditions is difficult and the reliability of these methods are sparsely described in electrolyte transport literature. In this work, we apply a potentiostatic polarization-based transport characterization approach typically used for polymer electrolytes to liquid electrolyte systems in an attempt to fully measure all transport coefficients (conductivity, total salt diffusion coefficient, thermodynamic factor and transference number) for the model system of LiPF 6 in an ethylene carbonate—ethyl methyl carbonate (EC:EMC) mixture. Using systematic timescale and statistical analyses, we find that transport coefficients measured using potentiostatic polarization of Li-Li symmetric cells exhibit strong correlation to Li electrode interfacial resistance, indicating that such methods are probing both bulk and interfacial phenomena. This reveals a major roadblock in characterizing electrolyte systems where the interfacial resistance is significantly larger than ohmic electrolyte resistance. As a result, we find that methods that rely on potentiostatic Li metal stripping/plating do not readily result in reliable liquid electrolyte transport coefficients, unlike similar methods for solid polymer electrolytes, where interfacial resistances are typically smaller than electrolyte resistances at the elevated temperatures typically of interest for such electrolytes.

25 ENERGY STORAGE↗

Abstract for Accelerator Magnets Magnetic Field Measurements

The chapter develops the formalism for the two-dimensional representation of the fields which are commonly found in accelerator magnets. The chapter describes the sense windings and associated components used in the precise measurement of these fields.

43 PARTICLE ACCELERATORS↗

Measurement of CP asymmetries and branching fraction ratios of B – decays to two charm mesons

The CP asymmetries of seven B – decays to two charm mesons are measured using data corresponding to an integrated luminosity of 9 fb –1 of proton-proton collisions collected by the LHCb experiment. Decays involving a D *0 or ${D}_s^{\ast -}$ meson are analysed by reconstructing only the D 0 or ${D}_s^{-}$ decay products. This paper presents the first measurement of $\mathcal{A}$ CP (B – → ${D}_s^{\ast -}$ D 0 ) and $\mathcal{A}$ CP (B – → ${D}_s^{-}$D $\ast$0 ), and the most precise measurement of the other five CP asymmetries. There is no evidence of CP violation in any of the analysed decays. Additionally, two ratios between branching fractions of selected decays are measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Møller polarimetry for PREX-2 and CREX

The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically , be known with 1% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.89% for PREX-2, and 0.85% for CREX. The uncertainty is purely systematic, accumulated from several different sources, but dominated by our knowledge of the target polarization. Our analysis also demonstrates the need for accurate atomic wave functions in order to correct for the Levchuk Effect. We describe the details of the polarimeter operation and analysis, as well as (for CREX) a comparison to results from a different polarimeter based on Compton scattering.

43 PARTICLE ACCELERATORS↗

TMD program at JLab

Measurements of multiplicities and asymmetries of multiparticle final states in wide kinematics, including dihadrons and vector mesons, will be crucial for a separation of different structure functions, and different contributions to specific structure functions, used in phenomenological studies of Semi-Inclusive DIS (SIDIS). Measurements of various beam Single Spin Asymmetries are discussed as a possible tool to separate different kinematical regions as well as different dynamical contributions. Precision measurements in JLab, including detailed studies of the $Q^2$ dependences of observables, would also allow testing the impact of several theoretical assumptions used in phenomenological studies of generalized PDFs (GPDs, TMDs) , also providing a mechanism for validation of the extraction frameworks, which is critical for the proper evaluation of systematic uncertainties.

Avagyan, Harutyun↗

Proton deflectometry with in situ x-ray reference for absolute measurement of electromagnetic fields in high-energy-density plasmas

In this work, we report a technique of proton deflectometry that uses a grid and an in situ reference x-ray grid image for precise measurements of magnetic fields in high-energy-density plasmas. A D 3 He fusion implosion provides a bright point source of both protons and x-rays, which is split into beamlets by a grid. The protons undergo deflections as they propagate through the plasma region of interest, whereas the x-rays travel along straight lines. The x-ray image, therefore, provides a zero-deflection reference image. The line-integrated magnetic fields are inferred from the shifts of beamlets between the deflected (proton) and reference (x-ray) images. We developed a system for analysis of these data, including automatic algorithms to find beamlet locations and to calculate their deflections from the reference image. The technique is verified in an experiment performed at OMEGA to measure a nonuniform magnetic field in vacuum and then applied to observe the interaction of an expanding plasma plume with the magnetic field.

47 OTHER INSTRUMENTATION↗

A New Measurement of the Extragalactic Background Light Using 15 yr of Fermi-large Area Telescope Data

The extragalactic background light (EBL) from ultraviolet to infrared comprises the emission from all stars, galaxies, and actively accreting black holes in the observable Universe. A precise measurement of the EBL is critically important to probe models of star formation and galaxy evolution. The EBL can be measured via the absorption imprint left on the spectra of γ-ray blazars. In this work, we rely on 15 yr of Fermi-LAT data and 1576 blazars to measure the EBL optical depth in the 0 < z < 4.3 range. We detect the EBL attenuation with ≅23σ significance and measure the optical depth in 19 redshift bins, extending the coverage and improving on our previous results. This allows us to reconstruct the evolution of the EBL and find general consistency with recent EBL models. These results represent the most precise determination of the EBL with GeV γ rays to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Metal-embedded fiber optic sensor packaging and signal demodulation scheme towards high-frequency dynamic measurements in harsh environments

Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.

47 OTHER INSTRUMENTATION↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗