Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Practice Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

WE-F-201-02: Review TG-186 and WGMBDCA Guidelines, Commission Process, and Dosimetry Benchmarks

With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

60 APPLIED LIFE SCIENCES↗

Adaptation of methodology to select structural alternatives of one-way slab in residential building to the guidelines of the European Committee for Standardization (CEN/TC 350)

The European Committee for Standardization (CEN) through its Technical Committee CEN/TC-350 is developing a series of standards for assessing the building sustainability, at both product and building levels. The practical application of the selection (decision making) of structural alternatives made by one-way slabs leads to an intermediate level between the product and the building. Thus the present study addresses this problem of decision making, following the CEN guidelines and incorporating relevant aspects of architectural design into residential construction. A life cycle assessment (LCA) is developed in order to obtain valid information for the decision making process (the LCA was developed applying CML methodology although Ecoindicator99 was used in order to facilitate the comparison of the values); this information (the carbon footprint values) is contrasted with other databases and with the information from the Environmental Product Declaration (EPD) of one of the lightening materials (expanded polystyrene), in order to validate the results. Solutions of different column disposition and geometries are evaluated in the three pillars of sustainable construction on residential construction: social, economic and environmental. The quantitative analysis of the variables used in this study enables and facilitates an objective comparison in the design stage by a responsible technician; the application of the proposed methodology reduces the possible solutions to be evaluated by the expert to 12.22% of the options in the case of low values of the column index and to 26.67% for the highest values. - Highlights: • Methodology for selection of structural alternatives in buildings with one-way slabs • Adapted to CEN guidelines (CEN/TC-350) for assessing the building sustainability • LCA is developed in order to obtain valid information for the decision making process. • Results validated comparing carbon footprint, databases and Env. Product Declarations • The proposal reduces the solutions to be evaluated to between 12.22 and 26.67%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Para-aortic Lymphadenectomy for Gynecologic Cancers: Introducing the “Trans-Retro-Peritoneal (TRP) Single-Port Access”

Background: In gynecological surgery to date, two distinct types of endoscopic accesses have been used to perform para-aortic lymphadenectomies: transperitoneal and extraperitoneal, each with advantages and disadvantages.{sup 1} We propose to develop a new mini-invasive access to perform an endoscopic extraperitoneal para-aortic lymphadenectomy via a single-port umbilical device that, to our knowledge, has never been described. Methods: This innovative approach combines both an extraperitoneal and intraperitoneal procedure via the same umbilical incision using one single trocar. A 3–4 cm trans-umbilical incision is performed and a three-channel single-port device (Gelpoint Mini°; Applied Medical, Rancho Santa Margarita, CA, USA) is introduced in the peritoneal cavity. After peritoneal exploration, the peritoneum overlying the aorta bifurcation is grabbed, raised to the umbilicus, opened, and the single-port device is then re-introduced into the retroperitoneal space. Results: The intervention has been successful in three patients with locally advanced cervical cancer (two International Federation of Gynecology and Obstetrics [FIGO] stage IB2, and one FIGO stage IVA) scheduled for concomitant radiochemotherapy after exclusion of any suspicious lymph nodes by 18F-fluorodeoxyglucose-positron emission tomography (FDG-PET), according to our standards of practice based on the European Society of Gynaecological Oncology (ESGO) and National Comprehensive Cancer Network (NCCN) guidelines.{sup 2,3} Due to the type of cancer, lymphadenectomy was limited to the infra-mesenteric nodes,{sup 2,4} although the dissection went up to the left renal vein in each case. We retrieved 13, 20, and 25 lymph nodes. No complications occurred. Conclusions: We describe a promising technique that combines all the advantages of the two previously described accesses without their disadvantages, and with the cosmetic benefit of one almost invisible single trans-umbilical scar.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility-Scale Power Tower Solar Systems: Performance Acceptance Test Guidelines

The purpose of these Guidelines is to provide direction for conducting performance acceptance testing for large power tower solar systems that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The recommendations have been developed under a National Renewable Energy Laboratory (NREL) subcontract and reviewed by stakeholders representing concerned organizations and interests throughout the concentrating solar power (CSP) community. An earlier NREL report provided similar guidelines for parabolic trough systems. These Guidelines recommend certain methods, instrumentation, equipment operating requirements, and calculation methods. When tests are run in accordance with these Guidelines, we expect that the test results will yield a valid indication of the actual performance of the tested equipment. But these are only recommendations--to be carefully considered by the contractual parties involved in the Acceptance Tests--and we expect that modifications may be required to fit the particular characteristics of a specific project.

14 SOLAR ENERGY↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are or could be practically implemented in a field test situation. These tests include: visual, infrared thermography, interdigital capacitance, indenter, relaxation time indenter, dynamic mechanical analyzer, infrared/near-infrared spectrometry, ultrasound, and distributed fiber optic temperature measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WE-A-210-00: Educational: Diagnostic Ultrasound QA

This presentation will focus on the present role of ultrasound medical physics in clinical practices. The first part of the presentation will provide an overview of ultrasound QC methodologies and testing procedures. A brief review of ultrasound phantoms utilized in these testing procedures will be presented. The second part of the presentation will summarize ultrasound imaging technical standards and professional guidelines by American College of Radiology (ACR), American Institute of Ultrasound in Medicine (AIUM), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC). The current accreditation requirements by ACR and AIUM for ultrasound practices will be described and the practical aspects of implementing QC programs to be compliant with these requirements will be discussed. Learning Objectives: Achieve familiarity with common ultrasound QC test methods and ultrasound phantoms. Understand the coverage of the existing testing standards and professional guidelines on diagnostic ultrasound imaging. Learn what a medical physicist needs to know about ultrasound program accreditation and be able to implement ultrasound QC programs accordingly.

60 APPLIED LIFE SCIENCES↗

WE-A-210-01: Overview of Methods and Accreditation Updates

This presentation will focus on the present role of ultrasound medical physics in clinical practices. The first part of the presentation will provide an overview of ultrasound QC methodologies and testing procedures. A brief review of ultrasound phantoms utilized in these testing procedures will be presented. The second part of the presentation will summarize ultrasound imaging technical standards and professional guidelines by American College of Radiology (ACR), American Institute of Ultrasound in Medicine (AIUM), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC). The current accreditation requirements by ACR and AIUM for ultrasound practices will be described and the practical aspects of implementing QC programs to be compliant with these requirements will be discussed. Learning Objectives: Achieve familiarity with common ultrasound QC test methods and ultrasound phantoms. Understand the coverage of the existing testing standards and professional guidelines on diagnostic ultrasound imaging. Learn what a medical physicist needs to know about ultrasound program accreditation and be able to implement ultrasound QC programs accordingly.

60 APPLIED LIFE SCIENCES↗

Development of Performance Acceptance Test Guidelines for Large Commercial Parabolic Trough Solar Fields: Preprint

Prior to commercial operation, large solar systems in utility-size power plants need to pass a performance acceptance test conducted by the EPC contractor or owners. In lieu of the present absence of engineering code developed for this purpose, NREL has undertaken the development of interim guidelines to provide recommendations for test procedures that can yield results of a high level ofaccuracy consistent with good engineering knowledge and practice. The fundamental differences between acceptance of a solar power plant and a conventional fossil-fired plant are the transient nature of the energy source and the necessity to utilize an analytical performance model in the acceptance process. These factors bring into play the need to establish methods to measure steady stateperformance, potential impacts of transient processes, comparison to performance model results, and the possible requirement to test, or model, multi-day performance within the scope of the acceptance test procedure. The power block and BOP are not within the boundaries of this guideline. The current guideline is restricted to the solar thermal performance of parabolic trough systems and hasbeen critiqued by a broad range of stakeholders in CSP development and technology.

14 SOLAR ENERGY↗

Expanding standards in viromics: in silico evaluation of dsDNA viral genome identification, classification, and auxiliary metabolic gene curation

Viruses influence global patterns of microbial diversity and nutrient cycles. Though viral metagenomics (viromics), specifically targeting dsDNA viruses, has been critical for revealing viral roles across diverse ecosystems, its analyses differ in many ways from those used for microbes. To date, viromics benchmarking has covered read pre-processing, assembly, relative abundance, read mapping thresholds and diversity estimation, but other steps would benefit from benchmarking and standardization. Here we use in silico-generated datasets and an extensive literature survey to evaluate and highlight how dataset composition (i.e., viromes vs bulk metagenomes) and assembly fragmentation impact (i) viral contig identification tool, (ii) virus taxonomic classification, and (iii) identification and curation of auxiliary metabolic genes (AMGs). The in silico benchmarking of five commonly used virus identification tools show that gene-content-based tools consistently performed well for long (≥3 kbp) contigs, while k -mer- and blast-based tools were uniquely able to detect viruses from short (≤3 kbp) contigs. Notably, however, the performance increase of k -mer- and blast-based tools for short contigs was obtained at the cost of increased false positives (sometimes up to ~5% for virome and ~75% bulk samples), particularly when eukaryotic or mobile genetic element sequences were included in the test datasets. Furthermore, for viral classification, variously sized genome fragments were assessed using gene-sharing network analytics to quantify drop-offs in taxonomic assignments, which revealed correct assignations ranging from ~95% (whole genomes) down to ~80% (3 kbp sized genome fragments). A similar trend was also observed for other viral classification tools such as VPF-class, ViPTree and VIRIDIC, suggesting that caution is warranted when classifying short genome fragments and not full genomes. Finally, we highlight how fragmented assemblies can lead to erroneous identification of AMGs and outline a best-practices workflow to curate candidate AMGs in viral genomes assembled from metagenomes. Together, these benchmarking experiments and annotation guidelines should aid researchers seeking to best detect, classify, and characterize the myriad viruses ‘hidden’ in diverse sequence datasets.

59 BASIC BIOLOGICAL SCIENCES↗

National Medical Care System May Impede Fostering of True Specialization of Radiation Oncologists: Study Based on Structure Survey in Japan

Purpose: To evaluate the actual work environment of radiation oncologists (ROs) in Japan in terms of working pattern, patient load, and quality of cancer care based on the relative time spent on patient care. Methods and Materials: In 2008, the Japanese Society of Therapeutic Radiology and Oncology produced a questionnaire for a national structure survey of radiation oncology in 2007. Data for full-time ROs were crosschecked with data for part-time ROs by using their identification data. Data of 954 ROs were analyzed. The relative practice index for patients was calculated as the relative value of care time per patient on the basis of Japanese Blue Book guidelines (200 patients per RO). Results: The working patterns of RO varied widely among facility categories. ROs working mainly at university hospitals treated 189.2 patients per year on average, with those working in university hospitals and their affiliated facilities treating 249.1 and those working in university hospitals only treating 144.0 patients per year on average. The corresponding data were 256.6 for cancer centers and 176.6 for other facilities. Geographically, the mean annual number of patients per RO per quarter was significantly associated with population size, varying from 143.1 to 203.4 (p < 0.0001). There were also significant differences in the average practice index for patients by ROs working mainly in university hospitals between those in main and affiliated facilities (1.07 vs 0.71: p < 0.0001). Conclusions: ROs working in university hospitals and their affiliated facilities treated more patients than the other ROs. In terms of patient care time only, the quality of cancer care in affiliated facilities might be worse than that in university hospitals. Under the current national medical system, working patterns of ROs of academic facilities in Japan appear to be problematic for fostering true specialization of radiation oncologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of EORTC Target Definition Guidelines for Dose-Intensified Salvage Radiation Therapy for Recurrent Prostate Cancer: Results of the Quality Assurance Program of the Randomized Trial SAKK 09/10

Purpose: Different international target volume delineation guidelines exist and different treatment techniques are available for salvage radiation therapy (RT) for recurrent prostate cancer, but less is known regarding their respective applicability in clinical practice. Methods and Materials: A randomized phase III trial testing 64 Gy vs 70 Gy salvage RT was accompanied by an intense quality assurance program including a site-specific and study-specific questionnaire and a dummy run (DR). Target volume delineation was performed according to the European Organisation for the Research and Treatment of Cancer guidelines, and a DR-based treatment plan was established for 70 Gy. Major and minor protocol deviations were noted, interobserver agreement of delineated target contours was assessed, and dose-volume histogram (DVH) parameters of different treatment techniques were compared. Results: Thirty European centers participated, 43% of which were using 3-dimensional conformal RT (3D-CRT), with the remaining centers using intensity modulated RT (IMRT) or volumetric modulated arc technique (VMAT). The first submitted version of the DR contained major deviations in 21 of 30 (70%) centers, mostly caused by inappropriately defined or lack of prostate bed (PB). All but 5 centers completed the DR successfully with their second submitted version. The interobserver agreement of the PB was moderate and was improved by the DR review, as indicated by an increased κ value (0.59 vs 0.55), mean sensitivity (0.64 vs 0.58), volume of total agreement (3.9 vs 3.3 cm{sup 3}), and decrease in the union volume (79.3 vs 84.2 cm{sup 3}). Rectal and bladder wall DVH parameters of IMRT and VMAT vs 3D-CRT plans were not significantly different. Conclusions: The interobserver agreement of PB delineation was moderate but was improved by the DR. Major deviations could be identified for the majority of centers. The DR has improved the acquaintance of the participating centers with the trial protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardization and best practices in single-cell testing for liquid alkaline water electrolysis

The increasing demand for efficient and sustainable hydrogen production has driven significant advancements in water electrolysis technologies. Among these, liquid alkaline water electrolysis (LAWE) stands out for its cost-effectiveness and scalability. This manuscript establishes best practices and standardized testing procedures for single-cell LAWE, focusing on the use of nickel foam as both anode and cathode substrates, while incorporating catalysts such as nickel-iron layered double hydroxide (NiFe-LDH) as the anode material and nickel-molybdenum on carbon (NiMo/C) as the cathode material. By providing detailed guidelines on material preparation, cell assembly, and performance evaluation, this work offers a comprehensive framework to improve reproducibility and ensure consistency. The results demonstrate that applying these best practices minimizes variability across different laboratories and experimental setups, laying the groundwork for more robust comparisons and accelerating progress in LAWE research.

08 HYDROGEN↗

Proteomics Goes to Court: A Statistical Foundation for Forensic Toxin/Organism Identification Using Bottom-Up Proteomics

Bottom-up proteomics is increasingly being used to characterize unknown environmental, clinical, and forensic samples. Proteomics-based bacterial identification typically proceeds by tabulating peptide “hits” (i.e. confidently identified peptides) associated with the organisms in a database; those organisms with enough hits are declared present in the sample. This approach has proven successful in laboratory studies, however, important research gaps remain. First, the common-practice reliance on unique peptides for identification is susceptible to a phenomenon known as signal erosion. Second, no general guidelines are available for determining how many hits are needed to make a confident identification. These gaps inhibit the transition of this approach to real-world samples where conditions vary and large databases may be needed. We propose statistical criteria for organism identification that applies regardless of sample quality or data analysis pipeline. These criteria are straightforward, producing a p-value on the result. We test the criteria on LC-MS/MS datasets representing 919 different bacterial and toxin datasets acquired with multiple data collection platforms. Results reveal a >95% correct species-level identification rate, demonstrating the effectiveness and robustness of proteomics-based organism/toxin identification.

Jarman, Kristin H.↗

Analysis of main steam isolation valve leakage in design basis accidents using MELCOR 1.8.6 and RADTRAD.

Analyses were performed using MELCOR and RADTRAD to investigate main steam isolation valve (MSIV) leakage behavior under design basis accident (DBA) loss-of-coolant (LOCA) conditions that are presumed to have led to a significant core melt accident. Dose to the control room, site boundary and LPZ are examined using both approaches described in current regulatory guidelines as well as analyses based on best estimate source term and system response. At issue is the current practice of using containment airborne aerosol concentrations as a surrogate for the in-vessel aerosol concentration that exists in the near vicinity of the MSIVs. This study finds current practice using the AST-based containment aerosol concentrations for assessing MSIV leakage is non-conservative and conceptually in error. A methodology is proposed that scales the containment aerosol concentration to the expected vessel concentration in order to preserve the simplified use of the AST in assessing containment performance under assumed DBA conditions. This correction is required during the first two hours of the accident while the gap and early in-vessel source terms are present. It is general practice to assume that at {approx}2hrs, recovery actions to reflood the core will have been successful and that further core damage can be avoided. The analyses performed in this study determine that, after two hours, assuming vessel reflooding has taken place, the containment aerosol concentration can then conservatively be used as the effective source to the leaking MSIV's. Recommendations are provided concerning typical aerosol removal coefficients that can be used in the RADTRAD code to predict source attenuation in the steam lines, and on robust methods of predicting MSIV leakage flows based on measured MSIV leakage performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and Commissioning Plan for a Laser Heater for FERMI@elettra

The purpose of a laser heater is to increase the electron beam uncorrelated energy spread as a way to control and ideally suppress the microbunching instability in the linac drive for x-rays FELs. We review the motivations for equipping FERMI with a laser heater and provide a specification for the basics parameters as well as a description of a practical layout including desired diagnostics provisions for both the electron and laser beams. We also outline some useful operational guidelines for commissioning.

43 PARTICLE ACCELERATORS↗

Soil stabilization and pavement recycling with self-cementing coal fly ash

This manual provides design information for self-cementing coal fly ash as the sole stabilizing agent for a wide range of engineering applications. As in any process, the application of sound engineering practices, appropriate testing, and evaluation of fly ash quality and characteristics will lend themselves to successful projects using the guidelines in this manual. Topics discussed include: self-cementing coal fly ash characteristics; laboratory mix design; stabilization of clay soils; stabilisation of granular materials; construction considerations; high sulfate ash; environmental considerations for fly ash stabilization; design considerations; state specification/guidelines/standards; and a sample of a typical stabilization specification.

01 COAL, LIGNITE, AND PEAT↗