Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Co-Extrusion (CoEx) for Cost Reduction of Advanced High-Energy-and-Power Battery Electrode Manufacturing

Co-Extrusion (CoEx) is a deposition technology developed at PARC that uses engineered fluidic channels to cause multiple streams of dissimilar fluids to impart shape to one another. Here, we describe the use of CoEx to produce structured cathode electrode films to improve electrochemical performance of thick electrode films. CoEx enables us to create structured electrode films that have periodic regions of enhanced ionic conductivity, enabling higher utilization of thicker cathode films at high discharge rates. While increasing electrode thickness is a known method for increasing energy density of battery electrodes, this increase in energy density typically also results in reduced power density. This project, a collaboration between the Palo Alto Research Center, Oak Ridge National Laboratories, and Ford Motor Company, seeks to first validate the benefits of CoEx at the coin cell level, before performing the necessary R&D effort to scale production up to large (10+ Ah) pouch cells that will show increased energy density without a reduction in power density. We used conventional battery materials (commercially available NMC, PVDF, carbon black, and graphite) to produce structured electrodes via CoEx and compared them to thick and thin conventionally produced (unstructured) battery electrodes. CoEx electrodes show improved high rate performance compared to unstructured electrodes, resulting in higher energy density pouch cells compared to the baseline electrode of 7 and 11% in volumetric and gravimetric energy density, respectively. These electrodes also showed substantially improved electrochemical performance at high discharge rates compared to thick conventional electrodes.

25 ENERGY STORAGE↗

Reducing Communication in Algebraic Multigrid Using Additive Variants

Algebraic multigrid (AMG) has proven to be an effective scalable solver on many high performance computers. However, its increasing communication complexity on coarser levels has shown to seriously impact its performance on computers with high communication cost. Moreover, additive AMG variants provide not only increased parallelism as well as decreased numbers of messages per cycle but also generally exhibit slower convergence. Here we present various new additive variants with convergence rates that are significantly improved compared to the classical additive algebraic multigrid method and investigate their potential for decreased communication, and improved communication-computation overlap, features that are essential for good performance on future exascale architectures.

97 MATHEMATICS AND COMPUTING↗

New Insights into the High‐Performance Black Phosphorus Anode for Lithium‐Ion Batteries

Abstract Black phosphorus (BP) is a promising anode material in lithium‐ion batteries (LIBs) owing to its high electrical conductivity and capacity. However, the huge volume change of BP during cycling induces rapid capacity fading. In addition, the unclear electrochemical mechanism of BP hinders the development of rational designs and preparation of high‐performance BP‐based anodes. Here, a high‐performance nanostructured BP–graphite–carbon nanotubes composite (BP/G/CNTs) synthesized using ball‐milling method is reported. The BP/G/CNTs anode delivers a high initial capacity of 1375 mA h g −1 at 0.15 A g −1 and maintains 1031.7 mA h g −1 after 450 cycles. Excellent high‐rate performance is demonstrated with a capacity of 508.1 mA h g −1 after 3000 cycles at 2 A g −1 . Moreover, for the first time, direct evidence is provided experimentally to present the electrochemical mechanism of BP anodes with three‐step lithiation and delithiation using ex situ X‐ray diffraction (XRD), ex situ X‐ray absorption spectroscopy (XAS), ex situ X‐ray emission spectroscopy, operando XRD, and operando XAS, which reveal the formation of Li 3 P 7 , LiP, and Li 3 P. Furthermore, the study indicates an open‐circuit relaxation effect of the electrode with ex situ and operando XAS analyses.

Li, Minsi↗

Laser-induced damage-growth threshold at 351 nm in the nanosecond regime in dielectric coatings employing different high-index materials

The laser-damage performance of HfO 2 /SiO 2 and Al 2 O 3 /SiO 2 mirrors was investigated at a laser wavelength of 351 nm with nanosecond pulse durations. A method was developed to quantify the laser-induced damage-growth threshold under conditions relevant to high-repetition-rate, large-aperture laser systems. The results suggest that the damage-growth performance cannot be inferred from the corresponding damage-initiation threshold that is commonly used to evaluate the performance of optical materials. Here, a systematic difference was also observed in the performance between these two groups of high-index materials, with the Al 2 O 3 /SiO 2 mirrors exhibiting about twofold improvement in the damage-growth threshold.

36 MATERIALS SCIENCE↗

Calculations of energies, transition rates, and lifetimes for the fluorine-like isoelectronic sequence with Z=31−35

Employing two state-of-the-art methods, multiconfiguration Dirac–Hartree–Fock and second-order many-body perturbation theory, highly accurate calculations are performed for the lowest 200 fine-structure levels arising from the 2l{sup 7},2l{sup 6}3l{sup ′} and 2l{sup 6}4l{sup ′} configurations of the fluorine-like isoelectronic sequence with Z=31−35. Complete and consistent atomic data, including excitation energies, lifetimes, wavelengths, and E1, E2, M1, M2 line strengths, oscillator strengths, and transition rates among these 200 levels are provided. Comparisons are made between the present two data sets, as well as with other available experimental and theoretical values. The present data are accurate enough for identification and deblending of emission lines involving the n=3,4 levels, and are also useful for modeling and diagnosing fusion plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of Nb-doped on the structure and electrochemical performance of LiFePO{sub 4}/C composites

The olivine-type niobium doping Li{sub 1−x}Nb{sub x}FePO{sub 4}/C (x=0, 0.005, 0.010, 0.015, 0.025) cathode materials were synthesized via a two-step ball milling solid state reaction. The effects of Nb doping were charactered by X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), galvanostatic intermittent titration technique (GITT), cyclic voltammetry (CV), electrochemical impedance spectra (EIS) and galvanostatic charge–discharge. It is found that Nb doping enlarges the interplanar distance of crystal plane parallel to [0 1 0] direction in LiFePO{sub 4}. In other words, it widens the one dimensional diffusion channels of Li{sup +} along the [0 1 0] direction. Electrochemical test results indicate that the Li{sub 0.99}Nb{sub 0.01}FePO{sub 4}/C composite exhibits the best electrochemical performance with initial special discharge capacity of 139.3 mA h g{sup −1} at 1 C rate. The present synthesis route is promising in making the solid state reaction method more practical for preparation of the LiFePO{sub 4} material. - Graphical abstract: The proper amount of Nb doping widens the one dimensional diffusion channels of Li{sup +} along the [0 1 0] direction. Display Omitted - Highlights: • The Nb doping LiFePO{sub 4}/C is prepared by a facile two-step ball milling solid state reaction. • The sample possesses the better high-rate performance. • The tap density of Li{sub 0.99}Nb{sub 0.01}FePO{sub 4}/C sample is 1.76 g cm{sup −3}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Sodium-Ion Battery Cathodes: A Low-Cost, Eco-Friendly Mechanofusion Route from TiO 2 Coating to Ti 4+ Doping

Layered oxide battery cathodes often require extra stabilization strategies, such as surface coating or doping, to mitigate side reactions and enhance longevity. Conventional methods such as aqueous deposition and atomic layer deposition are costly and environmentally unfriendly and even damage the original structure, especially for air-sensitive sodium-ion battery (SIB) cathodes. Herein, we introduce an all-dry mechanofusion technique that modifies hydroxide precursors with TiO 2 coating before sintering with a sodium source. Using advanced characterizations including X-ray diffraction, neutron diffraction, and solid-state nuclear magnetic resonance for structural insights, X-ray absorption spectroscopy to study metal valence states, and transmission X-ray microscopy for nanoscale visualization of nickel oxidation states, we verified that postsintering transforms TiO 2 surface coating into Ti doping, leading to improved Ni-oxidation homogeneity, modified charge compensation, and enhanced thermal stability. Electrochemical tests reveal superior performance in capacity retention, rate capability, and air stability for these modified cathodes, with pouch cells maintaining over 85% capacity after 650 cycles. This method presents a sustainable, cost-effective route for advanced SIB cathode development.

36 MATERIALS SCIENCE↗

Neural Image Compression: Generalization, Robustness, and Spectral Biases

Recent advances in neural image compression (NIC) have resulted in models which are starting to outperform traditional codecs. While this has led to growing excitement about using these methods in real-world applications, the successful adoption of any machine learning system (including NIC) in the wild requires it to generalize (and be robust) to unseen distribution shifts at deployment time. Unfortunately, current research lacks comprehensive datasets and informative tools to evaluate and understand compression performance in real-world settings. To bridge this crucial gap, first, this paper presents a comprehensive benchmark suite to evaluate the out-of-distribution (OOD) performance of image compression methods. Specifically, we design CLIC-C and Kodak-C by introducing 15 common corruptions to popular CLIC and Kodak benchmarks. Next, we propose spectrally inspired introspection tools to gain a deeper understanding of errors introduced by image compression methods as well as their OOD performance. To this end, we carry out a detailed performance comparison of the classical codec with various variants of NIC (e.g., original, variable rate, pruned), revealing intriguing findings that challenge our current understanding of the strengths and limitations of NIC. Finally, we corroborate our empirical findings with theoretical analysis, providing an in-depth view of the OOD performance of NIC. Our benchmarks, spectral introspection tools, and findings provide a crucial bridge to the real-world adoption of NIC. We hope that our work will propel future efforts in designing more robust and generalizable NIC methods.

neural networks, Variational Autoencoder, robustne↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

A Methodology for the Analysis of Water Oxidation Electrocatalysts in the Absence of Limiting Current that Avoids the Pitfalls of Existing Methods

Water oxidation is an important reaction studied as a way to generate electrons from water, to promote water splitting and the formation of green hydrogen. When using electrodes to drive homogeneous water oxidation catalysis, cyclic voltammograms are analyzed to provide catalytic rate constants. There are two main methods, foot-of-the-wave analysis (FOWA) and limiting current analysis. FOWA relies on approximations inherent to analyzing water oxidation catalysis, such as determining the formal potential of the catalytic intermediate, E 0 cat . Limiting current methods are the optimal way to analyze catalyst performance but rely on observable limiting current, which is virtually never seen in water oxidation. To avoid those issues, a method is proposed for analyzing nonideal cyclic voltammetry waveshapes in water oxidation: by analyzing rate data across a large range of potentials, an optimal potential, E 0 cat , can be obtained, where catalytic current, i cat , is nearly independent of scan rate and has a linear dependency on buffer concentration. Here, the method is applied to four homogeneous water oxidation catalysts with prior extensive electrochemical elucidation, all of which lack an ideal, purely kinetic waveshape in cyclic voltammetry. Application of the method avoids the biases of the other methods cited for the kinetic analyses of water oxidation catalysts.

14 SOLAR ENERGY↗

Damage Tolerance Assessment of Laser Clad Repairs of Coarse Grain Ti-6Al-4V

Background: Laser cladding offers a promising approach to repairing aviation components, with the ability to restore the geometric shape and the static and fatigue strength. Objective: The damage tolerance of a coarse grain Ti-6Al-4 V material is assessed via three sets of samples: (i) baseline, (ii) laser clad repaired, and (iii) laser cladding followed by heat treatment. Method: The specimens were subjected to fatigue loading using a marker band technique, in which cracks initiated from pre-defined laser slots and the small crack growth rates were measured by quantitative fractography. Additional characterization was performed on these samples, including hardness measurements, microstructure analysis, and multimodal residual stress analyses. Results: The region of the specimen undergoing laser cladding exhibited higher hardness values and a compressive residual stress, based on the slitting method. The samples subjected to heat treatment after cladding displayed negligible differences in grain size and minimal residual stress relaxation. Conclusions: The results demonstrated significant variability, with data demonstrating that cracks in the laser clad region (exhibiting the largest compressive residual stress) grew faster than cracks in the substrate region of the sample or in the baseline cases. Finally, these counterintuitive results are rationalized with additional analyses from synchrotron-based energy dispersive X-ray diffraction and high energy X-ray diffraction, demonstrating significant spatial variability in the residual elastic strains in the millimeter-sized prior β grains within the material.

36 MATERIALS SCIENCE↗

Revealing the Electrochemical Kinetics of Electrolytes in Nanosized LiFePO 4 Electrodes

Lithium-ion battery rate performance is ultimately limited by the electrolyte, yet the behaviors of electrolytes during high-rate (dis)charge remain elusive to electrochemical measurement. Herein, we develop and study a nanosized LiFePO 4 model system in which the electrolyte completely controls the electrochemical kinetics of the porous electrode. Impedance spectroscopy, cyclic voltammetry, and rate performance testing prove that ion transport in the electrolyte is the sole rate-limiting process, even in thin electrodes. A novel pseudo-steady-state extrapolation (S3E) method for Tafel analysis shows that LiFePO 4 obeys Butler-Volmer kinetics with a transfer coefficient of 3. The combination of these unexpectedly rapid interfacial kinetics and an activation barrier for phase transformation causes extreme reaction heterogeneity, which manifests as a moving reaction zone. Resistance versus capacity analysis enables direct measurement of electrolyte resistance growth during high-rate (dis)charge, revealing how the interaction between concentration polarization and a moving reaction zone controls electrolyte rate performance in LiFePO 4 electrodes. This work elucidates the profound impacts of the electrolyte on electrochemical measurements in porous battery electrodes: when the active material is not rate limiting, it is impossible to directly measure the intrinsic kinetics of the active material, but conversely, it becomes possible to directly measure the kinetics of the electrolyte.

Electrochemistry↗

Amorphous MoS 3 Infiltrated with Carbon Nanotubes as an Advanced Anode Material of Sodium-Ion Batteries with Large Gravimetric, Areal, and Volumetric Capacities

The search for earth-abundant and high-performance electrode materials for sodium-ion batteries represents an important challenge to current battery research. 2D transition metal dichalcogenides, particularly MoS2, have attracted increasing attention recently, but few of them so far have been able to meet expectations. In this study, it is demonstrated that another phase of molybdenum sulfide—amorphous chain-like MoS3—can be a better choice as the anode material of sodium-ion batteries. Highly compact MoS3 particles infiltrated with carbon nanotubes are prepared via the facile acid precipitation method in ethylene glycol. Compared to crystalline MoS2, the resultant amorphous MoS3 not only exhibits impressive gravimetric performance—featuring excellent specific capacity (≈615 mA h g-1), rate capability (235 mA h g-1 at 20 A g-1), and cycling stability but also shows exceptional volumetric capacity of ≈1000 mA h cm-3 and an areal capacity of >6.0 mA h cm-2 at very high areal loadings of active materials (up to 12 mg cm-2). The experimental results are supported by density functional theory simulations showing that the 1D chains of MoS3 can facilitate the adsorption and diffusion of Na+ ions. At last, it is demonstrated that the MoS3 anode can be paired with an Na3V2(PO4)3 cathode to afford full cells with great capacity and cycling performance.

Ye, Hualin↗

Analysis of the Factors Contributing to Vertebral Compression Fractures After Spine Stereotactic Radiosurgery

Purpose: To determine our institutional vertebral compression fracture (VCF) rate after spine stereotactic radiosurgery (SRS) and determine contributory factors. Methods and Materials: Retrospective analysis from 2001 to 2013 at a single institution was performed. With institutional review board approval, electronic medical records of 1905 vertebral bodies from 791 patients who were treated with SRS for the management of primary or metastatic spinal lesions were reviewed. A total of 448 patients (1070 vertebral bodies) with adequate follow-up imaging studies available were analyzed. Doses ranging from 10 Gy in 1 fraction to 60 Gy in 5 fractions were delivered. Computed tomography and magnetic resonance imaging were used to evaluate the primary endpoints of this study: development of a new VCF, progression of an existing VCF, and requirement of stabilization surgery after SRS. Results: A total of 127 VCFs (11.9%; 95% confidence interval [CI] 9.5%-14.2%) in 97 patients were potentially SRS induced: 46 (36%) were de novo, 44 (35%) VCFs progressed, and 37 (29%) required stabilization surgery after SRS. Our rate for radiologic VCF development/progression (excluding patients who underwent surgery) was 8.4%. Upon further exclusion of patients with hematologic malignancies the VCF rate was 7.6%. In the univariate analyses, females (hazard ratio [HR] 1.54, 95% CI 1.01-2.33, P=.04), prior VCF (HR 1.99, 95% CI 1.30-3.06, P=.001), primary hematologic malignancies (HR 2.68, 95% CI 1.68-4.28, P<.001), thoracic spine lesions (HR 1.46, 95% CI 1.02-2.10, P=.02), and lytic lesions had a significantly increased risk for VCF after SRS. On multivariate analyses, prior VCF and lesion type remained contributory. Conclusions: Single-fraction SRS doses of 16 to 18 Gy to the spine seem to be associated with a low rate of VCFs. To the best of our knowledge, this is the largest reported experience analyzing SRS-induced VCFs, with one of the lowest event rates reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep learning model for fast, science-based forecasting of fluid migration along faults in geologic carbon storage scenarios

Effective long-term geologic storage depends on robust site selection and credible, science-based forecasting of subsurface behavior to ensure storage integrity. For this work, we develop a deep learning–based reduced-order model (ROM) to quantify potential carbon dioxide (CO₂) and brine migration through geological faults. The ROM combines a Transformer model for binary classification and a Stacked Ensemble for regression, trained on a comprehensive dataset generated from 1400 physics-based reservoir simulations. Key geologic and operational parameters—including fault geometry, reservoir structure, and injection conditions—were systematically varied to capture a wide range of fluid migration scenarios. The ROM accurately predicts the onset of migration, cumulative migration volumes of both CO₂ and brine, and associated migration rates, as compared to an independent set of validation simulations, while significantly reducing computational cost compared to traditional simulation methods. Model performance was evaluated across diverse fault configurations, revealing that shallow reservoir geometry and fault angle are among the most influential factors governing migration behavior. Sensitivity analysis using SHapley Additive exPlanations (SHAP) provided interpretability, revealing distinct patterns in how geological and operational features drive transient versus cumulative migration outcomes. The ROM’s ability to rapidly simulate fault migration scenarios enables efficient sensitivity analyses, scenario evaluations, and decision support for site selection and monitoring design. This approach enhances the safety, scalability, and long-term operational performance of geologic carbon storage (GCS) systems by providing a robust, interpretable tool for predicting subsurface fluid migration and assessing fault-related migration potential.

42 ENGINEERING↗

The Impact of Intensity Modulated Radiation Therapy on Hospitalization Outcomes in the SEER-Medicare Population With Anal Squamous Cell Carcinoma

Purpose: We examined the impact of intensity modulated radiation therapy (IMRT) on hospitalization rates in the Surveillance, Epidemiology, and End Results (SEER)–Medicare population with anal squamous cell carcinoma (SCC). Methods and Materials: We performed a retrospective cohort study using the SEER-Medicare database. We identified patients with nonmetastatic anal SCC diagnosed between 2001 and 2011 and treated with chemoradiation therapy. We assessed the relation between IMRT and first hospitalization by use of a multivariate competing-risk model, as well as instrumental variable analysis, using provider IMRT affinity as our instrument. Results: Of the 1165 patients included in our study, 458 (39%) received IMRT. IMRT use increased over time and was associated more with regional and provider characteristics than with patient characteristics. The 3- and 6-month cumulative incidences of first hospitalization were 41.9% (95% confidence interval [CI], 37.3%-46.4%) and 47.6% (95% CI, 43.0%-52.2%), respectively, for the IMRT cohort and 46.7% (95% CI, 43.0%-50.4%) and 52.1% (95% CI, 48.4%-55.7%), respectively, for the non-IMRT cohort. IMRT was associated with a decreased hazard of first hospitalization compared with 3-dimensional radiation techniques (hazard ratio, 0.70; 95% CI, 0.58-0.84; P=.0002). Instrumental variable analysis suggested an even greater reduction in hospitalizations with IMRT after controlling for unmeasured confounders. There was a trend toward improved overall survival with IMRT, with an adjusted hazard ratio of 0.77 (95% CI, 0.59-1.00; P=.05). Conclusions: The use of IMRT is associated with reduced hospitalizations in elderly patients with anal SCC. Further work is warranted to understand the long-term health and cost impact of IMRT, particularly for patient subgroups most at risk of toxicity and hospitalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perspective: Tipping the scales: Search for drifting constants from molecular spectra

Transitions in atoms and molecules provide an ideal test ground for constraining or detecting a possible variation of the fundamental constants of nature. In this perspective, we review molecular species that are of specific interest in the search for a drifting proton-to-electron mass ratio μ. In particular, we outline the procedures that are used to calculate the sensitivity coefficients for transitions in these molecules and discuss current searches. These methods have led to a rate of change in μ bounded to 6 × 10{sup −14}/yr from a laboratory experiment performed in the present epoch. On a cosmological time scale, the variation is limited to |Δμ/μ| < 10{sup −5} for look-back times of 10–12× 10{sup 9} years and to |Δμ/μ| < 10{sup −7} for look-back times of 7× 10{sup 9} years. The last result, obtained from high-redshift observation of methanol, translates into μ{sup .}/μ=(1.4±1.4)×10{sup −17}/yr if a linear rate of change is assumed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-70: Evaluation of Multiple Isocentric Intensity Modulated and Volumetric Modulated Arc Therapy Techniques Using Portal Dosimetry

Purpose: To develop a method for verification of dose distribution in a patient during treatment using multiple isocentric Intensity modulated and volumetric modulated arc therapy techniques with portal dosimetry. Methods: Varian True Beam accelerator, equipped with an aS1000 megavoltage electronic portal imaging device (EPID) has an integrated image mode for portal dosimetry (PD). The source-to-imager distance was taken at 150 cm to avoid collision to the table. Fourteen fractions were analyzed for this study. During shift in a single plan from one isocenter to another isocenter, EPID also shifted longitudinally for each field by taking the extent of divergence of beam into the consideration for EPID distance of 150cm. Patients were given treatment everyday with EPID placed in proper position for each field. Several parameters were obtained by comparing the dose distribution between fractions to fraction. The impact of the intra-fraction and inter-fraction of the patient in combination with isocenter shift of the beams were observed. Results: During treatment, measurements were performed by EPID and were evaluated by the gamma method. Analysis was done between fractions for multiple isocenter treatments. The pass rates of the gamma analysis with a criterion of 3% and 3 mm for the 14 fractions were over 97.8% with good consistency. Whereas maximum gamma exceeded the criteria in few fractions (in<1 cc vol). Average gamma was observed in the criteria of 0.5%. Maximum dose difference and average dose differences were less than 0.22 CU and 0.01 CU for maximum tolerance of 1.0 CU and 0.2 CU respectively. Conclusion: EPID with extended distance is ideal method to verify the multiple isocentric dose distribution in patient during treatment, especially cold and hot spots in junction dose. Verification of shifts as well as the dose differences between each fraction due to inter-fraction and intra-fraction of the patient can be derived.

60 APPLIED LIFE SCIENCES↗