Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pa”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

NGC 4314. I - Visible and short-wavelength infrared surface photometry of the nucleus and bar

BVI (TI CCD) and JHK (University of Texas IR Camera) surface photometry of NGC 4314, an SB (rs)ap anemic spiral with a nuclear ring containing recent star formation, is presented. The shortwave IR (SWIR) frames reveal a nuclear bar of length 2 arcsec at PA of 0 deg. The nuclear ring and associated dust were detected in all SWIR color indices. A nuclear spiral was detected in the visible and SWIR just exterior to the ring. Extremely low-amplitude spiral-shaped deficits were found in the stellar distribution in the SWIR in this same region. These are attributed to dust, since CO is detectable at or near these locations. Average minor-axis profiles show this galaxy to have a nuclear bulge obeying the de Vaucouleurs r exp 1/4 law for values in the range 2-7 arcsec. The extinction and scattering characteristics of dust near the sites of recent star formation in the nuclear ring are discussed.

Benedict, G. F.↗

Extended testing of xenon ion thruster hollow cathodes

A hollow cathode wear-test of 508 hours was successfully completed at an emission current of 23.0 A and a xenon flow rate of 10 Pa-L/s. This test was the continuation of a hollow cathode contamination investigation. Discharge voltage was stable at 16.7 V. The cathode temperature averaged 1050 C with a 7 percent drop during the wear-test. Discharge ignition voltage was found to be approximately 20 V and was repeatable over four starts. Post-test analyses of the hollow cathode found a much improved internal cathode condition with respect to earlier wear-test cathodes. Negligible tungsten movement occurred and no formation of mono-barium tungstate was observed. These results correlated with an order-of-magnitude reduction in propellant feed-system leakage rate. Ba2CaWO6 and extensive calcium crystal formation occurred on the upstream end of the insert. Ba-Ca compound depositions were found on the Mo insert collar, on the Re electrical leads, and in the gap between the insert and cathode wall. This wear-test cathode was found to be in the best internal condition and had the most stable operating performance of any hollow cathode tested during this contamination investigation.

Sarver-Verhey, Timothy R.↗

Applied-field magnetoplasmadynamic engine developments

There are potential space exploration missions which may significantly benefit from the use of electric propulsion at power levels of hundreds of kilowatts. The applied magnetic field MPD thruster is potentially capable of efficient, high specific impulse operation in this power range. This paper describes current experimental and analytical efforts to further the development of such a thruster and presents the latest results. In particular, efforts to measure, simultaneously, the thrust developed by the archead and by the electromagnet, and to evaluate the effect of a diffuser on vacuum tank back pressure, are presented and discussed. It was found that with ammonia vapor as propellant, the vacuum tank pressure was reduced from 8 to 4.9 Pa at a power level of 80 kW. This pressure decrease is expected to become greater as the power and applied field are increased. Also, the development of a cathode/plasma interaction model for determining the heat loads to the cathode as functions of the various free stream plasma parameters is presented. This model is combined with a cathode thermal model in order to provide a complete and integrated picture of MPD thruster cathode operation. Several computational examples are used to illustrate the combined model.

Goodfellow, K. D.↗

Diode laser power module for beamed power transmission

Recent progress with powerful, efficient, and coherent monolithic diode master-oscillator/power-amplifier (M-MOPA) systems is promising for the development of a space-based diode laser power station. A conceptual design of a 50-kW diode laser power module was made for space-based power stations capable of beaming coherent power to the moon, Martian rovers, or other satellites. The laser diode power module consists of a solar photovoltaic array or nuclear power source, diode laser arrays (LDAs), a phase controller, beam-steering optics, a thermal management unit, and a radiator. Thermal load management and other relevant aspects of the system (such as power requirements and system mass) are considered. The 50-kW power module described includes the highest available efficiency of LD M-MOPA system to date. However, the overall efficiency of three amplifier stages, including the coupling efficiency, turns out to be 55.5 percent. Though a chain of PA stages generates a high-power coherent beam, there is a penalty due to the coupling loss between stages. The specific power of the 50-kW module using solar power is 6.58 W/kg.

Choi, S. H.↗

Cryogenic leak testing of tube fittings/valves

A high pressure and variable temperature cryogenic leak testing system was conceived and designed in order to conduct leakage testing of pipe fittings/valves in liquid hydrogen supply lines of the Space Shuttle. The system can create a continuous testing environment of variable temperature, 5.5 to about 300 K, and variable pressure, 0.01 to about 70 x 10 exp 5 Pa, with a large sample space, 90 mm diameter x 228 mm length, and at low operating cost. In terms of cryogenic leak testing the system has a special capability for extensive applications. The system comprised a variable temperature cryostat, a high pressure sample chamber, a vacuum pumping station, gas flow control system, pressure and temperature control systems, and leak detecting and measuring systems. A general discussion of cryogenic leak testing methods is also presented.

Jia, L. X.↗

Extended-testing of xenon ion thruster hollow cathodes

A hollow cathode wear-test of 508 hours was successfully completed at an emission current of 23.0 A and a xenon flow rate of 10 Pa-L/s. This test was the continuation of a hollow cathode contamination investigation. Discharge voltage was stable at 16.7 V. The cathode temperature averaged 1050 C with a 7 percent drop during the wear-test. Discharge ignition voltage was found to be approximately 20 V and was repeatable over four starts. Post-test analyses of the hollow cathode found a much improved internal cathode condition with respect to earlier wear-test cathodes. Negligible tungsten movement occurred and no formation of mono-barium tungsten was observed. These results correlated with an order-of-magnitude reduction in propellant feed-system leakage rate. Ba2CaWO6 and extensive calcium crystal formation occurred on the upstream end of the insert. Ba-Ca compound depositions were found on the Mo insert collar, on the Re electrical leads, and in the gap between the insert and cathode wall. This wear-test cathode was found to be in the best internal condition and had the most stable operating performance of any hollow cathode tested during this contamination investigation.

Sarver-Verhey, Timothy R.↗

Pancakelike domes on Venus

The shape of seven large domes on the plains of Venus, with volumes between 100 and 1000 cu km, is compared with that of an axisymmetric gravity current spreading over a rigid horizontal surface. Both the altimetric profiles and the horizontal projection of the line of intersection of domes on the SAR images agree well with the theoretical similarity solution for a newtonian fluid, but not with the shape calculated for a rigid-plastic rheology, nor with that for a static model with a strong skin. As a viscous current spreads, it generates an isotropic strain rate tensor whose magnitude is independent of radius. Such a flow can account for the randomly oriented cracks that are uniformly distributed on the surface of the domes. The stress induced by the flow in the plains material below is obtained, and is probably large enough to produce the short radial cracks in the surface of the plains beyond the domes. The viscosity of the domes can be estimated from their thermal time constants if spreading is possible only when the fluid is hot, and lies between 10(exp 14) and 10(exp 17) Pa s. Laboratory experiments show that such viscosities correspond to temperatures of 610 - 690 C in dry rhyolitic magmas. These temperatures agree with laboratory measurements of the solidus temperature of wet rhyolite. These results show that the development of the domes can be understood using simple fluid dynamical ideas, and that the magmas involved can be produced by wet melting at depths below 10 km, followed by eruption and degassing.

Mckenzie, Dan↗

Preliminary investigation of high power microwave plasmas for electrothermal thruster use

Results are reported from preliminary tests to evaluate the high power microwave electrothermal thruster (MET) concept, which employs a free-floating plasma discharge maintained by applied CW microwave power to heat a propellant gas flow. Stable plasmas have been created and maintained in helium (He), nitrogen (N2), and hydrogen (H2) as propellants in both the TM(sub 011) and TM(sub 012) modes at discharge pressures from 10 Pa to 69 kPa. Reproducible starting conditions of pressure and power have been documented for all the plasmas. Vortical inflow of the propellant gas was observed to cause the formation of on-axis 'spike' plasmas. The formation and unformation conditions of these plasmas were studied. Operation in the spike plasma condition enables maximum power absorption with minimum wall heating and offers maximum efficiency in heating the propellant gas. In the spike condition, plasmas of the three propellant gases were investigated in an open channel configuration to a maximum applied power level of 11.2 kW (in N2). Microwave power coupling efficiencies of over 90 percent were routinely obtained at absorbed power levels up to 2 kW. Magnetic nozzle effects were investigated with a superconducting solenoid Al magnet applying a high magnetic field to the plasmas in and exiting from the discharge tube.

Power, John L.↗

Effects of dust accumulation and removal on radiator surfaces on Mars

Tests were carried out to assess the impact of wind blown dust accumulation and abrasion on radiator surfaces on Mars. High emittance arc-textured copper and niobium-1 percent-zirconium samples were subjected to basaltic dust laden wind at Martian pressure (1000 Pa) at speeds varying from 19 to 97 m/s in the Martian Surface Wind Tunnel. The effect of accumulated dust was also observed by pre-dusting some of the samples before the test. Radiator degradation was determined by measuring the change in the emittance after dust was deposited and/or removed. The principle mode of degradation was abrasion. Arc textured Nb-1 percent-Zr proved to be more susceptible to degradation than Cu, and pre-dusting appeared to have lessened the abrasion.

Gaier, James R.↗

Glacio-isostatic crustal movements caused by historical volume change of the Vatnajokull ice cap, Iceland

Measurements of the lake level of Lake Langisjor at the SW edge of the Vatnajokull ice cap indicate a tilt of 0.26 +/- 0.06 microrad/yr away from the ice cap in the years of 1959-1991. The tilt is too large to be explained as an elastic Earth response to ice retreat this century, or to be caused by change in the gravitational pull of the ice cap, but it can be explained by sub-lithospheric viscous adjustment. Regional subsidence in historical times in SE Iceland can similarly be attributed to viscous adjustment resulting from the increased load of Vatnajokull during the Little Ice Age. The inferred sublithospheric viscosity is 1 x 10 exp 18 - 5 x 10 exp 19 Pa s.

Sigmundsson, Freysteinn↗

Deep mantle viscous structure with prior estimate and satellite constraint

A radially stratified and incompressible earth model with secular variation of the second degree gravity field J-dot(2) is used here to test sensitivity of data to viscosity increases with depth and convective boundary layer structure. Prior estimates and observed nontidal J-dot(23)(-C-dot(20)) are consistent with a layered lower mantle viscosity. Details of this layering are examined by comparing predicted and observed J-dot(3), J-dot(4). Speculation that a high-velocity layer exists above D-double prime is considered. With a 650-km thick deep high-viscosity layer, the remaining lower mantle is in one of two ranges: 1.5 to 3.5 x 10 exp 20 or 3.5 to about 10 exp 22 Pa s.

Ivins, E. R.↗

The inference of mantle viscosity from an inversion of the Fennoscandian relaxation spectrum

The theory of Peltier (1976) for mantle viscosity is adopted, within the framework of nonlinear Bayesian Inference, to invert the Fennoscandian relaxation spectra derived by McConnell (1968). A set of rigorous constraints which all models for the viscosity variation beneath Fennoscandian must satisfy is derived. These constraints are used to test the plausibility of a wide class of viscosity models. It is shown that a model with a weak asthenosphere overlying an isoviscous 10 exp 21 Pa s deep mantle provides to good fit to the relaxation spectrum. This is also true of models with a thin sublithospheric low-viscosity zone overlying a two-layer deep mantle with a moderate jump in viscosity across 670 km depth, and models with a viscosity jump of between four and six across isoviscous upper and lower mantle regions.

Mitrovica, J. X.↗

A vacuum (10 exp -9 torr) friction apparatus for determining friction and endurance life of MoS(x) films

An ultrahigh-vacuum tribometer for use in a ball-on-disk configuration was specially designed for measuring the friction and endurance life of magnetron-sputtered solid lubricating MoS(x) films deposited on sputter-cleaned 400 C stainless-steel disks, when slid against a 6-mm-diameter 440 C stainless-steel ball. The results of tests showed that the tribometer performs satisfactorily in unidirectional rotation in vacuum at a pressure of 10 exp -7 Pa, 10 exp -9 torr. Similarities are observed in the life cycle friction behavior and the coefficient of friction as a function of the number of disk revolutions, for MoS(x) films at average Hertzian contact from 0.33 to 0.69 GPa.

Miyoshi, Kazuhisa↗

Preliminary investigation of high power microwave plasmas for electrothermal thruster use

Results are reported from preliminary tests to evaluate the high power microwave electrothermal thruster concept, which employs a free-floating plasma discharge maintained by applied CW microwave power to heat a propellant gas flow. Stable plasmas have been created and maintained in He, N2, and H2 as propellants in both the TM(sub 011) and TM(sub 012) modes at discharge pressures from 10 Pa to 69 kPa. Vortical inflow of the propellant gas was observed to cause the formation of on-axis 'spike' plasmas. Operation in the spike plasma condition yields maximum power absorption with minimum wall heating and maximum propellant-heating efficiency; plasmas of the three propellant gases were investigated in the spike condition in an open channel to a maximum applied power level of 11.2 kW (in N2). Microwave power coupling efficiencies of over 90 percent were routinely obtained at absorbed power levels up to 2 kW. Magnetic nozzle effects were investigated with a superconducting solenoid Al magnet applying a high magnetic field to the plasmas in, and exiting from, the discharge tube.

Power, John L.↗

Diapirism on Triton - A record of crustal layering and instability

Cantaloupe terrain on Neptune's large, icy satellite Triton comprises an organized cellular pattern of noncircular dimples that structurally and geologically most closely resemble salt diapirs exposed on Earth. The mean separation of these cells is 47 km. Modeling of the cells as compositionally driven diapirs suggests that cantaloupe terrain forms by gravity-driven overturn within an ice crust about 20 km thick with a maximum viscosity of 10 exp 22 Pa s. These diapirs probably formed as a result of a density inversion in a layered crust composed partly of ice phases other than water ice.

Schenk, Paul↗

Development of spray guns for the application of rigid foam insulation

The paper describes the activities initiated to improve the existing spray gun system used for spraying insulating foam on the External Tank of the Space Shuttle, due to the quality variations of the applied foam noted in the past. Consideration is given to the two tasks of the project: (1) investigations of possible improvements, as an interim measure, to the spray gun currently used to apply the large acreage spray-on-foam insulation and the evaluation of other commercial equipment; and (2) the design and fabrication of a new automatic spray gun. The design and operation of the currently used Binks 43 PA spray gun are described together with several new breadboard spray guns designed and fabricated and the testing procedures developed. These new guns include the Modular Automatic Foam spray gun, the Ball Valve spray gun, and the Tapered Plug Valve (TPV) gun. As a result of tests, the TPV spray gun is recommended to replace the currently used automatic spray gun.

Allen, Peter B.↗

A vacuum four-ball tribometer to evaluate liquid lubricants for space applications

The design and operation of a vacuum tribometer, based on the four-ball configuration, is described. This tribometer evaluates the tribological characteristics of liquid lubricants for space applications. Operating conditions include: room temperature, loads to approximately 1000N, speeds to approximately 500 rpm, and pressures of approximately 10(exp -6)Pa. Tests can also be run at atmospheric pressure with air or nitrogen. Some typical test results are included.

Masuko, Masabumi↗

Phase aligner for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Phase Aligner (PA) or the Electronically Scanned Thinned Array Radiometer instrument has been designed and tested. Implemented in a single Xilinx XC3042PC84-125 Field Programmable Gate Array (FPGA), it is a dual-port register file which allows independent storage and phase coherent retrieval of antenna array data by the Central Processing Unit (CPU). It has dimensions of 4 x 20 bits and can be used at clock frequencies as high as 25 MHz. The ESTAR is a passive synthetic-aperture radiometer designed to sense soil moisture and ocean salinity at L-band.

Chren, William A., Jr.↗