Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

U.S. Solar Photovoltaic System Cost Benchmark: Q1 2017

This report benchmarks U.S. solar photovoltaic (PV) system installed costs as of the first quarter of 2017 (Q1 2017). We use a bottom-up methodology, accounting for all system and projectdevelopment costs incurred during the installation to model the costs for residential, commercial, and utility-scale systems. In general, we attempt to model the typical installation techniques and business operations from an installed-cost perspective. Costs are represented from the perspective of the developer/installer; thus, all hardware costs represent the price at which components are purchased by the developer/installer, not accounting for preexisting supply agreements or other contracts. Importantly, the benchmark also represents the sales price paid to the installer; therefore, it includes profit in the cost of the hardware, 1 along with the profit the installer/developer receives, as a separate cost category. However, it does not include any additional net profit, such as a developer fee or price gross-up, which is common in the marketplace. We adopt this approach owing to the wide variation in developer profits in all three sectors, where project pricing is highly dependent on region and project specifics such as local retail electricity rate structures, local rebate and incentive structures, competitive environment, and overall project or deal structures. Finally, our benchmarks are national averages weighted by state installed capacities.

14 SOLAR ENERGY↗

Correlation of Qualification and Accelerated Testing with Field Degradation

Qualification testing of solar photovoltaic (PV) modules per IEC 61215 standard encompasses a set of well-defined accelerated stress tests (irradiation, environmental, mechanical and electrical) with strict pass/fail criteria based on functionality/performance, electrical and mechanical safety, and visual requirements. The qualification testing does not identify all the possible reliability failures or durability issues witnessed in the actual field. However, it does identify the major/catastrophic design quality issues (infant mortality), which could occur early in a module’s field life. Unfortunately, in the industry, there is no consensus-based standard or protocol available to validate manufacturers’ warranty period claims based on the end-of-life wear-out failure mechanisms. Being able to predict the field degradation rates and lifetime using mode-specific accelerated tests on moderately field-aged modules, for example 10 years, for certain commonly occurring degradation modes would be a powerful contribution to all the stakeholders of the PV industry. There is a need to formulate guidelines to find the correlation of accelerated testing with field degradation for individual degradation modes observed in the field. Potential approaches to fulfill this need were experimented in this project and are presented in this report. Two of the most commonly seen degradation modes – encapsulant browning and solder bond thermomechanical fatigue – are addressed in this report through presenting the accelerated testing methods and physical modelling approaches. Two accelerated test methods (UV and thermal cycling) were designed to induce the wear-out mechanisms in the modules and not infant mortality failures. To focus on the wear-out failure modes, the tests were performed on field-aged modules, instead of fresh modules, with known degradation rates and degradation modes. The degradation rates were measured based on the degradation rates of individual cell parameters (short-circuit current, I sc and series resistance, R s ) instead of the degradation rate of maximum power (P max ) which cannot be used to study any specific/limited degradation mode as the P max degradation could be caused by many different degradation modes. The key characteristic parameter considered for encapsulant discoloration and solder bond degradation is I sc and R s , respectively. The developed physical models/equations relating the testing degradation data and field weather data were utilized to determine the acceleration factor (AF) and to predict the degradation rate for a specific degradation mode of PV modules installed in two different climates, Arizona (hot) and New York (cold). The predicted degradation rates for encapsulant browning and solder bond degradation have also been validated against the actual measured field degradation rates. UV testing cost reduction: To determine acceleration factor, single UV chamber was used for accelerated UV testing at three different temperatures simultaneously, instead of three chambers for three temperatures (or one chamber sequentially which is an extremely time-consuming approach). A passive heating approach was successfully used to achieve and maintain multiple temperatures in the accelerated UV chamber. Foam insulation boards of varying thicknesses were utilized to obtain three different temperatures for UV testing. However, these foam materials tend to disintegrate in the presence of moisture. To alleviate this problem, silicone heating blankets with temperature controls and humidifier can be used if the UV testing is to be performed under hot-humid conditions instead of conventional hot-dry conditions. Thermal cycling testing cost reduction: Single thermal cycling chamber was used for accelerated thermal cycling testing at three different upper temperatures simultaneously, instead of three chambers for three upper temperatures (or one chamber sequentially which is an extremely time-consuming approach). An active heating approach based on silicone heating blankets was successfully used to achieve and maintain multiple upper temperatures in the accelerated thermal cycling chamber. Such blankets provide stable temperature control and thereby more reliable and repeatable for replicate experiments.

14 SOLAR ENERGY↗

Explaining jurisdictional compliance with California’s top-down streamlined solar permitting law (AB 2188)

In the U.S., the process by which residential rooftop solar photovoltaic (PV) system installations are permitted and inspected by an “authority having jurisdiction” (AHJ) varies across AHJs. As the U.S. has roughly 23,000 AHJs with varying degrees of local autonomy, improving the cross-jurisdictional consistency of permitting and inspection is not a straightforward task. One promising approach is a “top-down” streamlined solar permitting (SSP) mandate by U.S. States to their AHJs. This study set out to understand the factors associated with the likelihood that an AHJ either did or did not comply with California’s top-down streamlined solar permitting law, AB2188, and then to consider how these factors might be relevant to the future prospects of top-down SSP outside of California. This report provides background material on AB2188 and tests five hypotheses about the factors that affect the likelihood that an AHJ will comply or not comply with AB2188, as developed from the policy diffusion literature and background knowledge on AB2188 and its implementation.

14 SOLAR ENERGY↗

Understanding streamlined solar permitting practices: A primer

A significant “soft cost” barrier to the growth of the residential solar PV market is the length of time and cross-jurisdictional inconsistency associated with the process by which PV system installations are built according to code, permitted by the local building department, and interconnected to the grid (see Burkhardt et al. 2015 for cost estimates).

14 SOLAR ENERGY↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

STS-97 Post Flight Presentation

Various shots highlight the STS-97 Endeavour mission. Footage shows the crew suiting up and leaving the Operations and Checkout (O&C) Building, the launch, and landing. Various on-orbit activities are seen, such as docking with the International Space Station (ISS), the spacewalks (installing the PV Module P6), array deployment, meeting the Expedition 1 crew, eating, and undocking. Shots show the northern lights and a meteorite entering Earth's atmosphere from above. The Andes can be seen from the Orbiter while the P6 arrays are deploying.

Source record↗

Integration of Photovoltaics into Building Energy Usage through Advanced Control of Rooftop Unit

This paper presents a computational approach to forecast photovoltaic (PV) power in kW based on a neural network linkage of publicly available cloud cover data and on-site solar irradiance sensor data. We also describe a control approach to utilize rooftop air conditioning units (RTUs) to support renewable integration. The PV forecasting method is validated using data from a rooftop PV panel installed on the Distributed Energy, Communications, and Controls (DECC) laboratory at Oak Ridge National Laboratory. The validation occurs in multiple phases to ensure that each component of the approach is the best representation of the actual expected output. The control of the RTU is based on model predictive methods.

Starke, Michael R↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/- 4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy: Preprint

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within plus or minus 4 percent, and only 1 percent greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

Exploring PV Circularity by Modeling Socio-Technical Dynamics of Modules' End-of-Life Management: Preprint

The circular economy (CE) tackles environmental and resource scarcity issues by maximizing value retention in the economy. The concept implies design strategies such as reducing the use of materials or improving products’ durability and end-of-life (EOL) strategies such as reusing products and components and recycling materials. With an estimated 80 million tons of global cumulative EOL photovoltaic (PV) modules, applying CE principles to the PV industry could alleviate resource scarcity issues while also providing economic benefits. However, transitioning to a CE may imply changes in organizations and consumer behaviors. In this context, assessment of CE strategies may require accounting for behavioral change, a requirement that methods from complex system science such as agent-based modeling meet. Thus, this paper uses an agent-based modeling (ABM) approach to study circularity in the photovoltaics supply chain. Four types of agents are represented in the ABM: PV owners, installers, recyclers, and manufacturers. Moreover, five possible EOL options – including three CE strategies – are modeled. Departing from traditional techno-economic analysis, the model includes techno-economic factors as well as social factors to model EOL management decisions. Results show that each dollar decrease in the recycling fees improves the recycling rate by roughly 1.1%. However, excluding social factors underestimates the effect that lower recycling prices have on material circularity.

28 EE - Advanced Manufacturing Office (EE-5A)↗

UV Degradation in Backsheets: A Ray-Tracing Irradiance Simulation Approach

Around 90% of current photovoltaic (PV) modules are less than ten years old. New PV technologies and materials are deployed without documented durability and performance histories. Accelerated testing attempts to capture degradation modes but can produce false results with such rapid deployment of new materials. Current testing assumes UV dosage on the rear of a module to be 10% of that incident on the front. We present a method to quantify degradation on PV backsheets in the field. We aim to evaluate if current acceleration factors for UV damage in chambers are properly estimating degradation for different PV site installations. The method leverages bifacial_radiance to ray-trace and evaluate irradiance on the front and the rear of the modules. Then an equation to estimate the relative degradation is proposed.

accelerated testing↗

Optimal Technology Investment and Operation in Zero-Net-Energy Buildings with Demand Response

The US Department of Energy has launched the Zero-Net-Energy (ZNE) Commercial Building Initiative (CBI) in order to develop commercial buildings that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge energy-efficient technologies and meet their remaining energy needs through on-site renewable energy generation. We examine how such buildings may be implemented within the context of a cost- or carbon-minimizing microgrid that is able to adopt and operate various technologies, such as photovoltaic (PV) on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive / demand-response technologies. We use a mixed-integer linear program (MILP) that has a multi-criteria objective function: the minimization of a weighted average of the building's annual energy costs and carbon / CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the CBI. Using a nursing home in northern California and New York with existing tariff rates and technology data, we find that a ZNE building requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve ZNE. For comparison, we analyze a nursing home facility in New York to examine the effects of a flatter tariff structure and different load profiles. It has trouble reaching ZNE status and its load reductions as well as efficiency measures need to be more effective than those in the CA case. Finally, we illustrate that the multi-criteria frontier that considers costs and carbon emissions in the presence of demand response dominates the one without it.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies and costs for achieving a ZC building or microgrid.

03 NATURAL GAS↗

Integrating More Solar with Smart Inverters: Preprint

In Hawai'i, the relatively high cost of electricity costs coupled with various incentives have made it cost-effective to install solar photovoltaics (PV) on residential homes and larger central-station PV plants. On some of the islands, PV has reached over 50% of the installed generation capacity base. To make sure these inverter-based PV plants can maintain stable and safe operations, new smart inverter functionality is being evaluated and demonstrated at significant scale across the islands This paper describes research conducted to validate high PV penetration scenarios with smart inverters and recent progress on the use of these advanced inverter grid support functions in actual power grids in Hawai'i.

14 SOLAR ENERGY↗

Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizes current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.

14 SOLAR ENERGY↗

Economic Competitiveness of U.S. Utility-Scale Photovoltaics Systems in 2015: Regional Cost Modeling of Installed Cost ($/W) and LCOE ($/kWh)

Utility-scale photovoltaics (PV) system growth is largely driven by the economic metrics of total installed costs and levelized cost of electricity (LCOE), which differ by region. This study details regional cost factors, including environment (wind speed and snow loads), labor costs, material costs, sales taxes, and permitting costs using a new system-level bottom-up cost modeling approach. We use this model to identify regional all-in PV installed costs for fixed-tilt and one-axis tracker systems in the United States with consideration of union and non-union labor costs in 2015. LCOEs using those regional installed costs are then modeled and spatially presented. Finally, we assess the cost reduction opportunities of increasing module conversion efficiencies on PV system costs in order to indicate the possible economic impacts of module technology advancements and help future research and development (R&D) effects in the context of U.S. SunShot targets.

14 SOLAR ENERGY↗

Reaching new solar heights: integrating high penetrations of PV into the power system

Installed capacity of solar photovoltaics (PV) continues to grow rapidly in the US. High penetrations and can create operational and reliability challenges. PV integration shares some attributes and mitigation strategies with wind, and differs in some key ways that will be discussed. This study investigates PV integration challenges and examines mitigation issues for utilities planning for high penetrations of PV, with a focus on the Western Interconnection of the US. System balancing becomes more difficult due to a duck‐shaped net load curve. Flexibility in the remaining generators, load, and the PV itself, is critical in balancing the system. Reliability impacts from PV have been studied less and addressed less than system balancing issues, but become more important at high penetrations. Understanding essential reliability services from PV, weak grid issues with PV, and distributed PV impacts on bulk power system reliability is critical for planning of high penetrations of PV.

Lew, Debra↗