Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLYSTYRENE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Elastic properties of protein functionalized nanoporous polymer films

Retaining the conformational structure and bioactivity of immobilized proteins is important for biosensor designs and drug delivery systems. Confined environments often lead to changes in conformation and functions of proteins. In this study, lysozyme is chemically tethered into nanopores of polystyrene thin films, and submicron pores in poly(methyl methacrylate) films are functionalized with streptavidin. Nanoindentation experiments show that stiffness of streptavidin increases with decreasing submicron pore sizes. Lysozymes in polystyrene nanopores are found to behave stiffer than the submicron pore sizes and still retain their specific bioactivity relative to the proteins on flat surfaces. Lastly, our results show that protein functionalized ordered nanoporous polystyrene/poly(methyl methacrylate) films present heterogeneous elasticity and can be used to study interactions between free proteins and designed surfaces.

36 MATERIALS SCIENCE↗

Nanoscale Mixing of Soft Solids

Assessing the state of mixing on the molecular scale in soft solids is challenging. Concentrated solutions of micelles formed by self-assembly of polystyrene-block-poly(ethylene-alt-propylene) (PS-PEP) diblock copolymers in squalane (C{sub 30}H{sub 62}) adopt a body-centered cubic (bcc) lattice, with glassy PS cores. Utilizing small-angle neutron scattering (SANS) and isotopic labeling ({sup 1}H and {sup 2}H (D) polystyrene blocks) in a contrast-matching solvent (a mixture of squalane and perdeuterated squalane), we demonstrate quantitatively the remarkable fact that a commercial mixer can create completely random mixtures of micelles with either normal, PS(H), or deuterium-labeled, PS(D), cores on a well-defined bcc lattice. The resulting SANS intensity is quantitatively modeled by the form factor of a single spherical core. These results demonstrate both the possibility of achieving complete nanoscale mixing in a soft solid and the use of SANS to quantify the randomness.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase and microphase separation of polymer thin films dewetted from silicon - a spin-echo resolved grazing incidence neutron scattering study.

An understanding of the structure of ultrathin polymer films on solid substrates has scientific importance in applications as well as in fundamental studies of polymer diffusion or adsorption. We present studies of the organization of dewetted droplets of polymers on a silicon surface using a new neutron scattering technique, spin-echo resolved grazing incidence scattering (SERGIS), that has the potential to address at the same time the droplet-droplet correlations and the chemical configuration inside each droplet. For the seminal experiments, the polarized neutron reflectometer EVA at the Institut Laue-Langevin, Grenoble, France, was equipped with a spin-echo setup, and measurements were taken on surface structures previously characterized by different techniques. The dewetted polymers used in our studies were pure polystyrene, a mixture of polystyrene and polyparamethylstyrene, and a diblock copolymer of the two homopolymers. Even with a provisional setup SERGIS, we were able to determine the correlation between the droplets, providing results in excellent agreement with those obtained by atomic force microscopy and grazing incidence small-angle X-ray and neutron scattering. In addition, it was confirmed that the correlation function for diblock copolymer droplets is more complex than for polymer mixtures, exhibiting partial ordering of the copolymer within each droplet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Depletion Interactions: Effects of Added Homopolymer on Ordered Phases Formed by Spherical Block Copolymer Micelles

Three distinct poly(styrene-b-isoprene) (SI) diblock copolymers with molecular weights of 16-16, 38-14, and 50-13 kDa for styrene and isoprene, respectively, formed spherical micelles when dissolved in diethyl phthalate (DEP). Since DEP is a styrene-selective solvent, micelles with polyisoprene in the core and polystyrene in the corona were formed. At block copolymer concentrations of 20%, 16%, and 14% in DEP, the spherical micelles of SI(16-16), SI(38-14), and SI(50-13) pack onto a face-centered cubic (FCC) lattice, a mixture of FCC and body-centered cubic (BCC) lattices, and a BCC lattice, respectively. Polystyrene homopolymers with molecular weights of 4, 48, and 180 kDa were added to these ordered solutions. The following general trends were observed: the FCC phase tended to disorder, and samples that originally behaved like soft solids exhibited liquidlike flow behavior. The effect increased strongly with both the molecular weight and concentration of homopolymer in the solution. Furthermore, the BCC lattice tended to be displaced by the FCC lattice, or to disorder, when homopolymer was added. These results can be explained by invoking depletion interactions, which have been studied extensively in colloid/polymer mixtures. However, the phenomenon differs in certain details from colloidal systems because the addition of homopolymer can also influence the aggregation number of the micelles, which in turn affects the lattice packing of the micelles.

36 MATERIALS SCIENCE↗

High-Pressure Micellar Solutions of Symmetric and Asymmetric Styrene?Diene Diblocks in Compressible Near Critical Solvents: Micellization Pressures and Cloud Pressures Respond but Micellar Cloud Pressures Insensitive to Copolymer Molecular Weight, Concentration, and Block Ratio Changes

Micellar solutions of polystyrene-block-polybutadiene and polystyrene-block-polyisoprene in propane are found to exhibit significantly lower cloud pressures than the corresponding hypothetical nonmicellar solutions. Such a cloud-pressure reduction indicates the extent to which micelle formation enhances the apparent diblock solubility in near-critical and hence compressible propane. Concentration-dependent pressure-temperature points beyond which no micelles can be formed, referred to as the micellization end points, are found to depend on the block type, size, and ratio. The cloud-pressure reduction and the micellization end point measured for styrene-diene diblocks in propane should be characteristic of all amphiphilic diblock copolymer solutions that form micelles in compressible solvents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of SMARTer at Very Low Scattering Vector q-Range Revealed by Monodisperse Nanoparticles

A monodisperse nanoparticle sample of polystyrene has been employed to determine performance of the 36 meter small-angle neutron scattering (SANS) BATAN spectrometer (SMARTer) at the Neutron Scattering Laboratory (NSL)--Serpong, Indonesia, in a very low scattering vector q-range. Detector position at 18 m from sample position, beam stopper of 50 mm in diameter, neutron wavelength of 5.66 A as well as 18 m-long collimator had been set up to achieve very low scattering vector q-range of SMARTer. A polydisperse smeared-spherical particle model was applied to fit the corrected small-angle scattering data of monodisperse polystyrene nanoparticle sample. The mean average of particle radius of 610 A, volume fraction of 0.0026, and polydispersity of 0.1 were obtained from the fitting results. The experiment results from SMARTer are comparable to SANS-J, JAEA - Japan and it is revealed that SMARTer is powerfully able to achieve the lowest scattering vector down to 0.002 A{sup -1}.

36 MATERIALS SCIENCE↗

SciBooNE's neutral current pi0 production measurements

The SciBooNE Collaboration has measured neutral current neutral pion production by the muon neutrino beam at a polystyrene target (C8H8). We obtained (7.7±0.5(stat.)−0.5+0.4(sys.))×10−2 as cross section ratio of the neutral current neutral pion production to total charged current cross section at the mean neutrino energy of 1.16 GeV. This result is consistent with the Monte Carlo prediction based on the Rein‐Sehgal model.

Kurimoto, Yoshinori↗

X-ray Thomson scattering measurements of temperature and density from multi-shocked CH capsules

Proof-of-principle measurements of the electron densities, temperatures, and ionization states of spherically compressed multi-shocked CH (polystyrene) capsules have been achieved using spectrally resolved x-ray Thomson scattering. A total energy of 13.5 kJ incident on target is used to compress a 70 μm thick CH shell above solid-mass density using three coalescing shocks. Separately, a laser-produced zinc He-α x-ray source at 9 keV delayed 200 ps-800 ps after maximum compression is used to probe the plasma in the non-collective scattering regime. The data show that x-ray Thomson scattering enables a complete description of the time-dependent hydrodynamic evolution of shock-compressed CH capsules, with a maximum measured density of ρ > 6 g cm –3 . Additionally, the results demonstrate that accurate measurements of x-ray scattering from bound-free transitions in the CH plasma demonstrate strong evidence that continuum lowering is the primary ionization mechanism of carbon L-shell electrons.

42 ENGINEERING↗

Origins of the two simultaneous mechanisms causing glass transition temperature reductions in high molecular weight freestanding polymer films

From ellipsometry measurements, Pye and Roth [Phys. Rev. Lett. 107, 235701 (2011)] presented evidence of the presence of two glass transitions originating from two distinctly different and simultaneous mechanisms to reduce the glass transition temperature within freestanding polystyrene films with thickness less than 70 nm. The upper transition temperature T{sub g}{sup u}(h) is higher than the lower transition temperature T{sub g}{sup l}(h) in the ultrathin films. After comparing their data with the findings of others, using the same or different techniques, they concluded that new theoretical interpretation is needed to explain the two transitions and the different dependences of T{sub g}{sup u}(h) and T{sub g}{sup l}(h) on film thickness and molecular weight. We address the problem based on advance in delineating the different viscoelastic mechanisms in the glass-rubber transition zone of polymers. Theoretical considerations as well as experiments have shown in time-scales immediately following the segmental α-relaxation are the sub-Rouse modes with longer length scale but shorter than that of the Rouse modes. The existence of the sub-Rouse modes in various polymers including polystyrene has been repeatedly confirmed by experiments. We show that the sub-Rouse modes can account for the upper transition and the properties observed. The segmental α-relaxation is responsible for the lower transition. This is supported by the fact that the segmental α-relaxation in ultrathin freestanding PS films had been observed by dielectric relaxation measurements and photon correlation spectroscopy. Utilizing the temperature dependence of the segmental relaxation times from these experiments, the glass transition temperature T{sub g}{sup α} associated with the segmental relaxation in the ultrathin film is determined. It turns out that T{sub g}{sup α} is nearly the same as T{sub g}{sup l}(h) of the lower transition, and hence definitely segmental α-relaxation is the mechanism for the lower transition. Since it is unlikely that the segmental α-relaxation can give rise to two very different transitions simultaneously, a new mechanism for the upper transition is needed, and the sub-Rouse modes provide the mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polystyrene/MoS{sub 2}@oleylamine nanocomposites

The effects of adding different concentrations of MoS{sub 2}@oleylamine nano particles on the thermal and mechanical properties of polystyrene (PS) nanocomposites have been investigated. X-ray diffraction and optical microscopy were used to characterize the morphology of the resulting nanocomposites. The thermal stability of the nanocomposites has been characterized by thermogravimetric analysis. It has been found that the MoS{sub 2}@oleylamine nanoparticles have a good compatibility with the PS matrix forming homogeneous dispersion even at high concentrations. The PS/MoS{sub 2}@oleylamine nanocomposites showed enhanced thermal stability in comparison with neat polystyrene.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The luminescence of BaF{sub 2} nanoparticles upon high-energy excitation

The dependence of X-ray excited luminescence intensity on BaF{sub 2} nanoparticle size was studied. A sharp decrease of self-trapped exciton luminescence intensity was observed when the nanoparticle size is less than 80 nm. The main mechanism of the luminescence quenching is caused by the escape of electrons from the nanoparticles. Escape of electrons from nanoparticles is confirmed by the considerable increase of luminescence intensity of the polystyrene scintillator with embedded BaF{sub 2} nanoparticles comparing with pure polystyrene scintillator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-field acoustic microbead trapping as remote anchor for single particle manipulation

We recently proposed an analytical model of a two-dimensional acoustic trapping of polystyrene beads in the ray acoustics regime, where a bead diameter is larger than the wavelength used. As its experimental validation, this paper demonstrates the transverse (or lateral) trapping of individual polystyrene beads in the near field of focused ultrasound. A 100 μm bead is immobilized on the central beam axis by a focused sound beam from a 30 MHz single element lithium niobate transducer, after being laterally displaced through hundreds of micrometers. Maximum displacement, a longest lateral distance at which a trapped bead can be directed towards the central axis, is thus measured over a discrete frequency range from 24 MHz to 36 MHz. The displacement data are found to be between 323.7 μm and 470.2 μm, depending on the transducer's driving frequency and input voltage amplitude. The experimental results are compared with their corresponding model values, and their relative errors lie between 0.9% and 3.9%. The results suggest that this remote maneuvering technique may be employed to manipulate individual cells through solid microbeads, provoking certain cellular reactions to localized mechanical disturbance without direct contact.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large scale ZnTe nanostructures on polymer micro patterns via capillary force photolithography

A novel approach to prepare micro patterns ZnTe nanostructures on Si (100) substrate using thermal evaporation is proposed by capillary Force Lithography (CFL) technique on a self-assembled sacrificial Polystyrene mask. Polystyrene thin films on Si substrates are used to fabricate surface micro-relief patterns. ZnTe nanoparticles have been deposited by thermal evaporation method. The deposited ZnTe nanoparticles properties were assessed by Atomic Force Microscope (AFM), Scanning Electron Microscope (SEM). SEM studies indicated that the particles are uniform in size and shape, well dispersed and spherical in shape. This study reports the micro-arrays of ZnTe nanoparticles on a self-assembled sacrificial PS mask using a capillary flow photolithography process which showed excellent, morphological properties which can be used in photovoltaic devices for anti-reflection applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurement of inclusive neutral current {pi}{sup 0} production on carbon in a few-GeV neutrino beam

The SciBooNE Collaboration reports inclusive neutral current neutral pion production by a muon neutrino beam on a polystyrene target (C{sub 8}H{sub 8}). We obtain (7.7{+-}0.5(stat){+-}0.5(sys))x10{sup -2} as the ratio of the neutral current neutral pion production to total charged current cross section; the mean energy of neutrinos producing detected neutral pions is 1.1 GeV. The result agrees with the Rein-Sehgal model implemented in our neutrino interaction simulation program with nuclear effects. The spectrum shape of the {pi}{sup 0} momentum and angle agree with the model. We also measure the ratio of the neutral current coherent pion production to total charged current cross section to be (0.7{+-}0.4)x10{sup -2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols

Purpose: To compare calibration of the Leksell Gamma Knife according to the American Association of Physicists in Medicine Task Groups 21 and 51 protocols. A new phantom was fabricated for this purpose. Its design, physical properties, and composition are described. Materials and methods: The Gamma Knife TG-51 calibration phantom is designed to be filled with water and support an ionization chamber positioned at its center. The phantom is thimble-shaped, with a 2 mm plastic wall to contain water. The phantom and chamber assembly was mounted in a LeksellTM stereotactic frame. The location of the chamber's sensitive volume was determined using computed tomography. The chamber-phantom assembly was attached to the 18 mm helmet in the Gamma Knife by the stereotactic frame. The phantom's geometry allowed radiation beams from each of the 201 Gamma Knife cobalt-60 sources to converge after an 8 cm path to the ionization chamber's sensitive volume. This is similar to the arrangement by which one calibrates the Gamma Knife using the manufacturer-supplied polystyrene phantom. Results: The phantom was attached to the Gamma Knife so that the ionization chamber was reproducibly positioned at the convergence of the radiation beams. Because of the phantom's design, the phantom could be affixed to either trunnions or the automatic patient positioning system, once mounted in the LeksellTM stereotectic frame. Comparisons using different phantoms and protocols resulted in the following calibration ratios for TG-21 in the polystyrene sphere phantom, TG-21 in the water phantom, and TG-51 in the water phantom, respectively: 1.000, 1.008, 0.986, when corrected for transmission through the plastic water reservoir wall and using the same ionization chamber. Transmission measurements using a 1 cm thickness of the same material in the Co-60 beam determined that the phantom's 2 mm plastic wall resulted in a reduction in the measured the output by 0.5%. Conclusions: Calibration of the Gamma Knife can be performed in liquid water using the AAPM TG-51 protocol and this new phantom, thereby eliminating uncertainties with respect to the composition of the manufacturer's phantom. Perturbation of calibration measurements by nonwater materials was characterized and could be corrected. Calibration values for the Gamma Knife that were obtained using the three methods for our phantoms agree to within 1.4%. TG21 and TG51 calibration of the Gamma Knife using the water phantom agreed to within 2.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Unintended attenuation in the Leksell Gamma Knife registered Perfexion trade mark sign calibration-phantom adaptor and its effect on dose calibration

The calibration of Leksell Gamma Knife Perfexion (LGK PFX) is performed using a spherical polystyrene phantom 160 mm in diameter, which is provided by the manufacturer. This is the same phantom that has been used with LGK models U, B, C, and 4C. The polystyrene phantom is held in irradiation position by an aluminum adaptor, which has stainless steel side-fixation screws. The phantom adaptor partially attenuates the beams from sectors 3 and 7 by 3.2% and 4.6%, respectively. This unintended attenuation introduces a systematic error in dose calibration. The overall effect of phantom-adaptor attenuation on output calibration of the LGK PFX unit is to underestimate output by about 1.0%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of phantom material and dimensions on experimental {sup 192}Ir dosimetry

In treatment planning of brachytherapy, absorbed dose is calculated by superposing predetermined distributions of absorbed dose to water in water for the single source according to the irradiation pattern [i.e., placement of the source(s) or dwelling position(s)]. Single-source reference water data are derived from Monte Carlo (MC) simulations and/or experiments. For reasons of positional accuracy, experimental brachytherapy dosimetry is most often performed in plastic phantoms. This work investigates the water equivalence of phantoms made from polystyrene, PMMA, and solid water for {sup 192}Ir dosimetry. The EGSnrc MC code is used to simulate radial absorbed dose distributions in cylindrical phantoms of dimensions ranging in size from diameter and height of 20 cm to diameter and height of 40 cm. Water equivalence prevails if the absorbed dose to water in the plastic phantom is the same as the absorbed dose to water in a water phantom at equal distances from the source. It is shown that water equivalence at a specified distance from the source depends not only on the size of the plastic phantom but also on the size of the water phantom used for comparison. Compared to equally sized water phantoms, phantoms of polystyrene are less water equivalent than phantoms of PMMA and solid water but compared to larger water phantoms they are the most water equivalent. Although phantom dimension is the most important single factor influencing the dose distributions around {sup 192}Ir sources, the effect of material properties is non-negligible and becomes increasingly important as phantom dimensions increase. The importance of knowing the size of the water phantom whose data underlies treatment planning systems, when using such data as a reference in, e.g., detector evaluation studies, is discussed. To achieve the highest possible accuracy in experimental dosimetry, phantom-specific correction factors should be used.

61 RADIATION PROTECTION AND DOSIMETRY↗