Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design, construction, and calibration of a three-axis, high-frequency magnetic probe (B-dot probe) as a diagnostic for exploding plasmas

A three-axis, 2.5 mm overall diameter differential magnetic probe (also known as B-dot probe) is discussed in detail from its design and construction to its calibration and use as diagnostic of fast transient effects in exploding plasmas. A design and construction method is presented as a means to reduce stray pickup, eliminate electrostatic pickup, reduce physical size, and increase magnetic signals while maintaining a high bandwidth. The probe's frequency response is measured in detail from 10 kHz to 50 MHz using the presented calibration method and compared to theory. The effect of the probe's self-induction as a first order correction in frequency, O({omega}), on experimental signals and magnetic field calculations is discussed. The probe's viability as a diagnostic is demonstrated by measuring the magnetic field compression and diamagnetism of a sub-Alfvenic ({approx}500 km/s,M{sub A}{approx}0.36) flow created from the explosion of a high-density energetic laser plasma through a cooler, low-density, magnetized ambient plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Detection of Tunneling Ionization

We have experimentally detected optical harmonics that are generated due to a tunneling-ionization-induced modulation of the electron density. The optical signature of electron tunneling can be isolated from concomitant optical responses by using a noncollinear pump-probe setup. Whereas previously demonstrated tools for attosecond metrology of gases, plasmas, and surfaces rely on direct detection of charged particles, detection of the background-free time-resolved optical signal, which uniquely originates from electron tunneling, offers an interesting alternative that is especially suited for systems in which free electrons cannot be directly measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multidimensional Visualization of MHD and Turbulence in Fusion Plasmas [Multi-dimensional Visualization of Turbulence in Fusion Plasmas]

Here, quasi-optical imaging at sub-THz frequencies has had a major impact on fusion plasma diagnostics. Mm-wave imaging reflectometry utilizes microwaves to actively probe fusion plasmas, inferring the local properties of electron density fluctuations. Electron cyclotron emission imaging is a multichannel radiometer that passively measures the spontaneous emission of microwaves from the plasma to infer local properties of electron temperature fluctuations. These imaging diagnostics work together to diagnose the characteristics of turbulence. Important quantities such as amplitude and wavenumber of coherent fluctuations, correlation lengths and decor relation times of turbulence, and poloidal flow velocity of the plasma are readily inferred.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal limits of a rapidly swept Langmuir probe

The finite, electrostatically achievable, temporal resolution of plasma properties from a turbulent discharge is limited by an array of effects wherein the theory of Langmuir probes breaks down. Formulations for the particle transit time, sheath formation time, plasma-probe resonance, polarization current, sheath capacitance, stray capacitance, and mutual capacitance effects are all evaluated for time-resolved operation of a Langmuir probe. The resulting time scales serve to place a theoretical bound on the maximum rate of a rapidly swept Langmuir probe as analyzed with typical thin-sheath collisionless probe theory. For plasma typical to the plume of a Hall effect thruster [xenon plasma, n{sub e}=(1-1000)x10{sup +15} m{sup -3}, and T{sub e}=1-20 eV], upper limits of 0.01-70 kHz are observed for a noncapacitive compensated Langmuir probe. With a high-speed dual Langmuir probe (HDLP) (a regular probe plus a null compensation probe), the upper probing frequency limits are increased to 0.04-11 MHz limited by sheath capacitance in the far and near field, and polarization effects for closer internal measurements. For a typical tokamak edge plasma (with HDLP), the thermally equilibrated hotter species (typically T{sub e}approx =T{sub i}approx =10 to 20 eV) and lighter ions together lend higher limiting rates of ion transit, sheath formation, and sheath capacitance effects (in excess of 20 MHz), but the fully magnetized plasma complicates the collected probe current, limiting the allowable sweep rate to <1 MHz (for a magnetic field of 2 T). Thus we find that the upper rate of Langmuir probe sweeping is in the low megahertz range for both electric thruster and fusion plasma device diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurement of ICRF-Enhanced Plasma Potentials on WEST Using Reciprocating Emissive Probes

An extensive documentation of ICRF-enhanced plasma potentials has been conducted over two experimental campaigns on the WEST tokamak using reciprocating emissive probes magnetically connected to two ICRF antennas. The collected data spans a wide range of antenna electrical settings (coupled power, toroidal phasing, left–right power balance) and plasma parameters (density at the antenna limiter above and below the lower hybrid resonance, plasma current, minority fraction). By scanning the edge safety factor across multiple probe plunges, the magnetic connection between the probe and the antenna varied, enabling the construction of a 2D map of the plasma and floating potentials around an active ICRF antenna. This dataset will be used to validate RF simulation tools equipped with the sheath boundary condition and used to predict RF rectified potentials and ICRF-induced impurity sputtering in future machines. This paper presents the diagnostic and some initial measurements, while the rest will be reported elsewhere.

Diab, Raymond [Massachusetts Inst. of Technology (↗

Measuring the electron density gradients of dense plasmas by deflectometry using short-wavelength probe

A new and simple experimental technique for the measurement of electron density gradients in dense laser-produced plasmas using an electromagnetic wave probe is presented. The main advantage of this method is the low requirements on coherence of the probing beam. The method is based on measuring the deformation of the Talbot pattern of a two-dimensional grating that stems from the distortion of the probe beam wave-front caused by the gradients of the index of refraction. The compromise between spatial resolution and sensitivity for the given wavelength of the probe beam is set by the experimental design. The proposed technique was experimentally verified on plasmas that were created by either a point focus or a line focus of a laser interacting with various solid targets. In the experiments reported here, all plasmas were probed by a Ne-like Zn x-ray laser beam at 21.2 nm, but the technique is applicable for any wavelength of the probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-invasive probe diagnostic method for electron temperature and ion current density in atmospheric pressure plasma jet source

The electrical probe diagnostics are very hard to be applied to atmospheric plasmas due to severe perturbation by the electrical probes. To overcome this, the probe for measuring electron temperature and ion current density is indirectly contacted with an atmospheric jet source. The plasma parameters are obtained by using floating harmonic analysis. The probe is mounted on the quartz tube that surrounds plasma. When a sinusoidal voltage is applied to a probe contacting on a quartz tube, the electrons near the sheath at dielectric tube are collected and the probe current has harmonic components due to probe sheath nonlinearity. From the relation of the harmonic currents and amplitude of the sheath voltage, the electron temperature near the wall can be obtained with collisional sheath model. The electron temperatures and ion current densities measured at the discharge region are in the ranges of 2.7–3.4 eV and 1.7–5.2 mA/cm{sup 2} at various flow rates and input powers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical and experimental study of the microwave cut-off probe for electron density measurements in low-temperature plasmas

The microwave cut-off probe for the electron density measurement in low-temperature plasmas is described in this article. It is based on the wave cutoff in an unmagnetized plasma. The measurement principle is analyzed theoretically using a model of plasma slab. Because of the high-pass characteristic of plasma, the waves above the cut-off frequency can penetrate the plasma slab, whereas the lower frequency waves are reflected from the cut-off layer. Therefore, an obvious critical point can be observed in the wave transmission spectrum. The abscissa of the critical point indicates the cut-off frequency, which is directly related to the maximum electron density between transmitting/receiving antennas of the cut-off probe. The measured electron densities are in agreement with the data obtained by the Langmuir probe. Experimental results show that the microwave cut-off probe can be used to diagnose the plasmas with a wide range of parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A restoration model of distorted electron density in wave-cutoff probe measurement

This study investigates the problem of electron density distortion and how the density can be restored in a wave-cutoff probe. Despite recent plasma diagnostics research using a wave-cutoff probe, the problem of electron density distortion caused by plasma conditions has not been resolved. Experimental results indicate that electron density measured using the wave-cutoff method is highly susceptible to variations in the probe tip gap. This electron density distortion is caused by the bulk plasma disturbance between probe tips, and it must be removed for calculating the absolute electron density. To do this, a detailed analytic model was developed using the power balance equation near probe tips. This model demonstrates the characteristics of plasma distortion in wave-cutoff probe measurement and successfully restored the absolute value of electron density with varying probe tip gaps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolving interactions between ion-cyclotron range of frequencies heating and the scrape-off layer plasma in EAST using divertor probes

Waves in the ion-cyclotron range of frequencies (ICRF) used for tokamak heating are known to interact strongly with the scrape-off layer (SOL) plasma, potentially limiting ICRF performance. We present the effect of ICRF heating on triple-probe signals in the Experimental Advanced Superconducting Tokamak (EAST) experiment, an advanced superconducting tokamak with two ICRF antennas and 12 MW of ICRF source power in support of high-power and long-pulse operation. Applying time-resolved magnetic mapping to the divertor probe arrays enables detailed sensing of the spatial structure of the SOL modifications. We observe a sharp transition in floating potential from negative to positive over a length scale of a centimeter at a major radius just inboard of the ICRF antenna. The largest changes in floating potential are observed not for probes connecting to the active ICRF antennas but rather to the main limiter or limiters for inactive lower hybrid launchers. Ion saturation current can be greatly reduced for probes mapping just in front of an antenna. Where relevant, comparison with results from the National Spherical Torus Experiment are made. This work will provide insight into sputtering, impurity production and antenna coupling as higher ICRF power levels are attempted on EAST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron plasmas as a diagnostic tool for hyperfine spectroscopy of antihydrogen

Long term magnetic confinement of antihydrogen atoms has recently been demonstrated by the ALPHA collaboration at CERN, opening the door to a range of experimental possibilities. Of particular interest is a measurement of the antihydrogen spectrum. A precise comparison of the spectrum of antihydrogen with that of hydrogen would be an excellent test of CPT symmetry. One prime candidate for precision CPT tests is the ground-state hyperfine transition; measured in hydrogen to a precision of nearly one part in 10{sup 12}. Effective execution of such an experiment with trapped antihydrogen requires precise knowledge of the magnetic environment. Here we present a solution that uses an electron plasma confined in the antihydrogen trapping region. The cyclotron resonance of the electron plasma is probed with microwaves at the cyclotron frequency and the subsequent heating of the electron plasma is measured through the plasma quadrupole mode frequency. Using this method, the minimum magnetic field of the neutral trap can be determined to within 4 parts in 10{sup 4}. This technique was used extensively in the recent demonstration of resonant interaction with the hyperfine levels of trapped antihydrogen atoms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma flows during the ablation stage of an over-massed pulsed-power-driven exploding planar wire array

We characterize the plasma flows generated during the ablation stage of an over-massed exploding planar wire array, fielded on the COBRA pulsed-power facility (1 MA peak current, 250 ns rise time). The planar wire array is designed to provide a driving magnetic field (80–100 T) and current per wire distribution (about 60 kA), similar to that in a 10 MA cylindrical exploding wire array fielded on the Z machine. Over-massing the arrays enables continuous plasma ablation over the duration of the experiment without implosion. The requirement to over-mass on the Z machine necessitates wires with diameters of 75–100μm, which are thicker than wires usually fielded on wire array experiments. To test ablation with thicker wires, we perform a parametric study by varying the initial wire diameter between 33 and 100 μm. The largest wire diameter (100 μm) array exhibits early closure of the cathode-wire gap, while the gap remains open over the duration of the experiment for wire diameters between 33 and 75 μm. Laser plasma interferometry and time-gated extreme-ultraviolet (XUV) imaging are used to probe the plasma flows ablating from the wires. The plasma flows from the wires converge to generate a pinch, which appears as a fast-moving (V≈100kms−1) column of increased plasma density (n¯e≈2×1018cm−3) and strong XUV emission. Finally, we compare the results with three-dimensional resistive-magnetohydrodynamic (MHD) simulations performed using the code GORGON, the results of which reproduce the dynamics of the experiment reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probe measurements of a cesium plasma in a simulated thermionic energy converter

Cesium-filled thermionic energy converters are considered as electrical energy sources in future spacecraft requiring tens to hundreds of kilowatts of electric power. The high operating temperatures necessary for a large specific power and high efficiency impose stringent constraints on the converter fabrication. The converter physics for reducing operating temperatures and cesium plasma losses are being studied to achieve high reliability without sacrificing the power performance of the converters. Various cesium parameters which affect the converter performance are: (1) electron temperatures, (2) plasma ion densities, and (3) electric potential profiles. These were investigated using a Langmuir probe in a simulated converter. The parameters were measured in different cesium discharge modes.

Shimada, K.↗

Detection of electric field around field-reversed configuration plasma

Electric-field probes consisting of copper plates are developed to measure electric fields in a vacuum region around a plasma. The probes detect oscillating electric fields with a maximum strength of approximately 100 V/m through a discharge. Reproducible signals from the probes are obtained with an unstable phase dominated by a rotational instability. It is found that the azimuthal structure of the electric field can be explained by the sum of an n=2 mode charge distribution and a convex-surface electron distribution on the deformed separatrix at the unstable phase. The former distribution agrees with that anticipated from the diamagnetic drift motions of plasma when the rotational instability occurs. The latter distribution suggests that an electron-rich plasma covers the separatrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Pump-Probe Measurements using a Laser-Plasma Accelerator (Final Report)

This project funded one graduate student, Mario Balcazar, to perform experiments on high power laser facilities to study the application of X-rays generated by laser wakefield accelerated electrons for advanced radiography, in particular X-ray phase contrast imaging of hydrodynamic shocks/instabilities. The work made use of the DOE’s LaserNetUS facilities. We performed dynamic phase-contrast X-ray imaging of the shock generated by a 200 ps duration laser pulse (E = 1 J, I = 10 15 Wcm –2 ) with a 30 µm diameter liquid target, with unprecedented spatio-temporal resolution. This includes multi-shock generation within the liquid jet and plasma instability formation. Innovative electron-beam radiography was used to probe the laser-plasma interplay finding evidence of bilateral heating of the water followed by strong electric field generation. These measurements help explain some of the discrepancies between simulation and experiment and pave the way to better plasma diagnostic systems in HED and ICF physics experiments. This work was performed in collaboration with researchers from Michigan, LLNL, LBL and Sandia National Laboratories, Queen’s University Belfast and Imperial College.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Existence of a virtual cathode close to a strongly electron emissive wall in low density plasmas

The interaction between an electron emissive wall, electrically biased in a plasma, is revisited through a simple fluid model. We search for realistic conditions of the existence of a non-monotonic plasma potential profile with a virtual cathode as it is observed in several experiments. We mainly focus our attention on thermionic emission related to the operation of emissive probes for plasma diagnostics, although most conclusions also apply to other electron emission processes. An extended Bohm criterion is derived involving the ratio between the two different electron densities at the potential minimum and at the background plasma. The model allows a phase-diagram analysis, which confirms the existence of the non-monotonic potential profiles with a virtual cathode. This analysis shows that the formation of the potential well critically depends on the emitted electron current and on the velocity at the sheath edge of cold ions flowing from the bulk plasma. As a consequence, a threshold value of the governing parameter is required, in accordance to the physical nature of the electron emission process. The latter is a threshold wall temperature in the case of thermionic electrons. Experimental evidence supports our numerical calculations of this threshold temperature. Besides this, the potential well becomes deeper with increasing electron emission, retaining a fraction of the released current which limits the extent of the bulk plasma perturbation. This noninvasive property would explain the reliable measurements of plasma potential by using the floating potential method of emissive probes operating in the so-called strong emission regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wall current probe: A non-invasive in situ plasma diagnostic for space and time resolved current density distribution measurement

In the context of low temperature plasma research, we propose a wall current probe to determine the local charged particle fluxes flowing to the chamber walls. This non-intrusive planar probe consists of an array of electrode elements which can be individually biased and for which the current can be measured separately. We detail the probe properties and present the ability of the diagnostic to be used as a space and time resolved measurement of the ion and electron current density at the chamber walls. This diagnostic will be relevant to study the electron transport in magnetized low-pressure plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Analysis of the Floating Potential Measurement Unit aboard the International Space Station

We present data from the Floating Potential Measurement Unit (FPMU), that is deployed on the starboard (S1) truss of the International Space Station. The FPMU is a suite of instruments capable of redundant measurements of various plasma parameters. The instrument suite consists of: a Floating Potential Probe, a Wide-sweeping spherical Langmuir probe, a Narrow-sweeping cylindrical Langmuir Probe, and a Plasma Impedance Probe. This paper gives a brief overview of the instrumentation and the received data quality, and then presents the algorithm used to reduce I-V curves to plasma parameters. Several hours of data is presented from August 5th, 2006 and March 3rd, 2007. The FPMU derived plasma density and temperatures are compared with the International Reference Ionosphere (IRI) and USU-Global Assimilation of Ionospheric Measurement (USU-GAIM) models. Our results show that the derived in-situ density matches the USU-GAIM model better than the IRI, and the derived in-situ temperatures are comparable to the average temperatures given by the IRI.

Barjatya, Aroh↗