Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PIE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical investigation of plasma wave generation by pulsed electron beams in space

Here, we report theoretical calculations of plasma wave generation in the whistler modes and in the extraordinary modes, by pulsed electron beams in a magnetized plasma. The numerical simulations of the wave generation take into account the longitudinal expansion of the electron beam due to the space charge force and the energy spread. The work presented in this article provides predictions for the wave generation performance of the beam plasma interactions experiment (Beam PIE), where pulsed electron beams were produced by a spaceborne radio frequency (RF) linear accelerator. We also theoretically explore the desirable properties of the pulsed electron beam for future space experiments, which will be the next step toward eventually demonstrating the radiation-belt remediation (RBR).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Interactive Visual Analytics Framework for Multi-Field Data in a Geo-Spatial Context

Climate research produces a wealth of multivariate data. These data often have a geospatial reference and so it is of interest to show them within their geospatial context. One can consider this configuration as a multi field visualization problem, where the geospace provides the expanse of the field. However, there is a limit on the amount of multivariate information that can be fit within a certain spatial location, and the use of linked multivari ate information displays has previously been devised to bridge this gap. In this paper we focus on the interactions in the geographical display, present an implementation that uses Google Earth, and demonstrate it within a tightly linked parallel coordinates display. Several other visual representations, such as pie and bar charts are integrated into the Google Earth display and can be interactively manipulated. Further, we also demonstrate new brushing and visualization techniques for parallel coordinates, such as fixedwindow brushing and correlationenhanced display. We conceived our system with a team of climate researchers, who already made a few important discov eries using it. This demonstrates our system’s great potential to enable scientific discoveries, possibly also in oth er domains where data have a geospatial reference.

Environmental Molecular Sciences Laboratory↗

A Perspective of Energy Codes and Regulations for the Buildings of the Future

Today’s building energy codes focus on prescriptive requirements for features of buildings that are directly controlled by the design and construction teams and verifiable by municipal inspectors. Although these code requirements have had a significant impact, they fail to influence a large slice of the building energy use pie – including not only miscellaneous plug loads, cooking equipment and commercial/industrial processes, but the maintenance and optimization of the code-mandated systems as well. Currently, code compliance is verified only through the end of construction, and there are no limits or consequences for the actual energy use in an occupied building. In the future, our suite of energy regulations will likely expand to include building efficiency, energy use or carbon emission budgets over their full life cycle. Intelligent building systems, extensive renewable energy, and a transition from fossil fuel to electric heating systems will likely be required to meet ultra-low-energy targets. This paper lays out the authors’ perspectives on how buildings may evolve over the course of the 21st century and the roles that codes and regulations will play in shaping those buildings of the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gas-phase synthesis of anthracene and phenanthrene via radical-radical reaction induced ring expansions

Unraveling reaction mechanisms of aromatic and resonance-stabilized radicals is critical to understanding molecular mass growth processes to polycyclic aromatic hydrocarbons (PAHs) and carbonaceous nanoparticles in distinct astrophysical environments (molecular clouds, circumstellar envelopes) and combustion systems. Using photoelectron photoion coincidence spectroscopy (PEPICO), we explored the gas-phase reaction of the methyl radical (CH 3 • ) with the aromatic and resonance-stabilized fluorenyl radical (C 13 H 9 • ) under high-temperature conditions in a chemical microreactor. Anthracene and phenanthrene were detected isomer-selectively using photoionization efficiency (PIE) curves and mass-selected threshold photoelectron (ms-TPE) spectra. While phenanthrene is produced through a radical-radical recombination of the carbon-centered radicals, anthracene may plausibly be formed through an unconventional radical addition to a low spin-density fluorenyl carbon. These pathways result in five-membered ring expansion—a critical mechanism crucial to PAH mass growth converting bent PAHs into planar nanostructures.

Goettl, Shane J. [University of Hawai‘i at Mānoa, ↗

Human Factors Evaluation of Energy Visualization Dashboards

Energy visualization systems provide information about use in real-time to assist users with energy efficiency. In this study, three energy visualization dashboards for small businesses were developed and tested. Performance measurement, NASA Task Load Index (TLX) workload assessment, and posttest survey were used to conduct the usability testing. Compared with the dashboards that were designed using line charts and tables, a dashboard designed using visuals (e.g., gauges, pie charts, and flashing lights) produced quicker response time, lower mental and temporal demand and effort ratings, and higher ratings of engagement, interest, and trustworthiness.

Nimbarte, Ashish D. (ORCID:0000000210599112)↗

Micromechanical Properties of the SiC and Pyrolytic Carbon Layers in Tristructural-Isotropic Coated Particles

Tristructural isotropic (TRISO) coated particle fuel was initially developed for high temperature gas cooled reactors (HTGR) and has been proposed for several other advanced reactor concepts. The design of TRISO particles focuses on preventing the release of fission products in normal and off-normal reactor conditions. The particle design features an actinide bearing fuel kernel that is surrounded by three pyrolytic carbon (PyC) layers and a silicon carbide layer (SiC). The mechanical stability of the particle and fission product retention for both metallic and gaseous fission products depend on the SiC layer. Post irradiation examination (PIE) of TRISO fuel from the first two US DOE Advanced Gas Reactor Fuel Development and Qualification Program irradiation campaigns, AGR-1 and AGR-2, had identified a low rate of particles exhibiting cracking in the SiC layer that did not propagate across the SiC layer. While cracking in the SiC is rare for test conditions and particles associated with the AGR program, understanding the stress state and mechanical properties of the SiC and PyC layers related to particle architecture can aid predicting thermomechanical response of TRISO fuel under the prescribed operation envelope and beyond as well as aiding in the development of similar fuel concepts for other advanced reactors. The presented investigation shows the relationship of the mechanical properties and mechanical response (e.g., understanding crack propagation) of the SiC and PyC layers relative to position within the particle. Testing was conducted on the inner and outer PyC layers of TRISO particles to quantify differences in mechanical behavior.

Montoya, Katherine [ORNL] (ORCID:0000000326955086)↗

AGR-1 Irradiated Test Train Preliminary Inspection and Disassembly First Look

The AGR-1 irradiation experiment ended on November 6, 2009, after 620 effective full power days in the Advanced Test Reactor, achieving a peak burnup of 19.6% FIMA. The test train was shipped to the Materials and Fuels Complex in March 2010 for post-irradiation examination. The first PIE activities included non-destructive examination of the test train, followed by disassembly of the test train and individual capsules and detailed inspection of the capsule contents, including the fuel compacts and the graphite fuel holders. Dimensional measurements of the compacts, graphite holders, and steel capsules shells were performed using a custom vision measurement system (for outer diameters and lengths) and conventional bore gauges (for inner diameters). Gamma spectrometry of the intact test train gave a preliminary look at the condition of the interior components. No evidence of damage to compacts or graphite components was evident from the isotopic and gross gamma scans. Neutron radiography of the intact Capsule 2 showed a high degree of detail of interior components and confirmed the observation that there was no major damage to the capsule. Disassembly of the capsules was initiated using procedures qualified during out-of-cell mockup testing. Difficulties were encountered during capsule disassembly due to irradiation-induced changes in some of the capsule components’ properties, including embrittled niobium and molybdenum parts that were susceptible to fracture and swelling of the graphite fuel holders that affected their removal from the capsule shells. This required various improvised modifications to the disassembly procedure to avoid damage to the fuel compacts. Ultimately the capsule disassembly was successful and only one compact from Capsule 4 (out of 72 total in the test train) sustained damage during the disassembly process, along with the associated graphite holder. The compacts were generally in very good condition upon removal. Only relatively minor damage or markings were visible using high resolution photographic inspection. Compact dimensional measurements indicated diametrical shrinkage of 0.9 to 1. 4%, and length shrinkage of 0.2 to 1.1%. The shrinkage was somewhat dependent on compact location within each capsule and within the test train. Compacts exhibited a maximum diametrical shrinkage at a fast neutron fluence of approximately 3×1021 n/cm2. A multivariate statistical analysis indicates that fast neutron fluence as well as compact position in the test train influence compact shrinkage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing and Reducing Plug and Process Loads in Retail Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Office Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AFIP-4 Irradiation Summary Report

The Advanced Test Reactor (ATR) Full size plate In center flux trap Position (AFIP) experiment AFIP-4 was designed to evaluate the performance of monolithic uranium-molybdenum (U-Mo) fuels at a scale prototypic of research reactor fuel plates. The AFIP-4 test further examine the fuel/clad interface and its behavior under extreme conditions. After irradiation, fission gas retention measurements will be performed during post irradiation (PIE). The following report summarizes the life of the AFIP-4 experiment through end of irradiation, including a brief description of the safety analysis, as-run neutronic analysis results, hydraulic testing results, and thermal analysis results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmarks for GADRAS performance validation.

The performance of the Gamma Detector Response and Analysis Software (GADRAS) was validated by comparing GADRAS model results to experimental measurements for a series of benchmark sources. Sources for the benchmark include a plutonium metal sphere, bare and shielded in polyethylene, plutonium oxide in cans, a highly enriched uranium sphere, bare and shielded in polyethylene, a depleted uranium shell and spheres, and a natural uranium sphere. The benchmark experimental data were previously acquired and consist of careful collection of background and calibration source spectra along with the source spectra. The calibration data were fit with GADRAS to determine response functions for the detector in each experiment. A one-dimensional model (pie chart) was constructed for each source based on the dimensions of the benchmark source. The GADRAS code made a forward calculation from each model to predict the radiation spectrum for the detector used in the benchmark experiment. The comparisons between the GADRAS calculation and the experimental measurements are excellent, validating that GADRAS can correctly predict the radiation spectra for these well-defined benchmark sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Magnetic Diagnostic Code for 3D Fusion Equilibria

A synthetic magnetic diagnostics code for fusion equilibria is presented. This code calculates the response of various magnetic diagnostics to the equilibria produced by the VMEC and PIES codes. This allows for treatment of equilibria with both good nested flux surfaces and those with stochastic regions. DIAGNO v2.0 builds upon previous codes through the implementation of a virtual casing principle. The codes is validated against a vacuum shot on the Large Helical Device where the vertical field was ramped. As an exercise of the code, the diagnostic response for various equilibria are calculated on the Large Helical Device (LHD).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AGR-1 Safety Test Predictions using the PARFUME code

The PARFUME modeling code was used to predict failure probability of TRISO-coated fuel particles and diffusion of fission products through these particles during safety tests following the first irradiation test of the Advanced Gas Reactor program (AGR-1). These calculations support the AGR-1 Safety Testing Experiment, which is part of the PIE effort on AGR-1. Modeling of the AGR-1 Safety Test Predictions includes a 620-day irradiation followed by a 300-hour heat-up phase of selected AGR-1 compacts. Results include fuel failure probability, palladium penetration, and fractional release of fission products. Results show that no particle failure is predicted during irradiation or heat-up, and that fractional release of fission products is limited during irradiation but that it significantly increases during heat-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AFIP-4 Irradiation Summary Report

The Advanced Test Reactor (ATR) Full size plate In center flux trap Position (AFIP) experiment AFIP-4 was designed to evaluate the performance of monolithic uranium-molybdenum (U-Mo) fuels at a scale prototypic of research reactor fuel plates. The AFIP-4 test further examine the fuel/clad interface and its behavior under extreme conditions. After irradiation, fission gas retention measurements will be performed during post irradiation (PIE)1,2. The following report summarizes the life of the AFIP-4 experiment through end of irradiation, including a brief description of the safety analysis, as-run neutronic analysis results, hydraulic testing results, and thermal analysis results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Natural Gas and the Transformation of the U.S. Energy Sector: A Program Studying Multi-sector Opportunities and Impacts

In recognition of the major transitions occurring within the U.S. energy economy, the Joint Institute for Strategic Energy Analysis (JISEA) and Stanford University's Precourt Institute for Energy (PIE) engaged energy system stakeholders from government, industry, academia, and the environmental community in a discussion about the priority issues for a program of rigorous research relating to natural gas. Held December 10-11, 2012 on the Golden, CO campus of the National Renewable Energy Laboratory, the workshop provided invited experts opportunity to describe the state of current knowledge in defined topic areas, and to suggest analytic priorities for that topic area. Following discussion, all stakeholders then contributed potential research questions for each topic, and then determined priorities through an interactive voting process. This record of proceedings focuses on the outcomes of the discussion.

03 NATURAL GAS↗

A Magnetic Diagnostic Code for 3D Fusion Equilibria

A synthetic magnetic diagnostics code for fusion equilibria is presented. This code calculates the response of various magnetic diagnostics to the equilibria produced by the VMEC and PIES codes. This allows for treatment of equilibria with both good nested flux surfaces and those with stochastic regions. DIAGNO v2.0 builds upon previous codes through the implementation of a virtual casing principle. The code is validated against a vacuum shot on the Large Helical Device (LHD) where the vertical field was ramped. As an exercise of the code, the diagnostic response for various equilibria are calculated on the LHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Retail Buildings: Assessing and Reducing Plug and Process Loads in Retail Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗