Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design of non-fluorinated proton exchange membranes from Poly(Terphenyl fluorenyl isatin) with fluorene-linked sulfonate groups and microblock structures

Proton exchange membranes (PEMs) are essential components in energy storage and conversion devices, such as fuel cells and electrolyzers. Here, in this study, we developed a series of non-fluorinated PEMs from poly(terphenyl fluorenyl isatin) with fluorene-pendent disulfonate groups. These polymers feature a microblock structure composed of hydrophobic blocks, hydrophilic blocks, and alternating blocks, arising from the differences in reactivity, concentration, and solubility between the hydrophobic p-terphenyl and hydrophilic disulfonated fluorene monomers. As a result, the sulfonic acid groups are unevenly distributed along the polymer chains, forming densely charged regions (IEC = 3.52 meq/g) with large ion clusters and lightly charged regions (IEC = 2.16 meq/g) with small ion clusters. This microstructure, combined with the degree of sulfonation, significantly influences the overall properties of the membranes, including robust mechanical strength (47.1–63.2 MPa), high thermal stability (up to 270 °C), low swelling ratio (18–25% at 80 °C), and high proton conductivity (136–169 mS/cm in deionized water at 80 °C). The PFLSH60 membrane demonstrated comparable fuel cell performance to Nafion 212. Its hydrogen crossover current density was more than two times lower (0.86 mA/cm 2 for PFLSH60 compared to 1.83 mA/cm 2 for Nafion 212) under testing conditions of 80 °C and 100% RH. This significantly reduced crossover improves fuel utilization in fuel cell stacks. This work offers valuable insights into the design of robust, high-performance PEMs by systematically analyzing the relationships between membrane structure, properties, and performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High temperature proton exchange membranes with enhanced proton conductivities at low humidity and high temperature based on polymer blends and block copolymers of poly(1,3-cyclohexadiene) and poly(ethylene glycol)

Hot (at 120 °C) and dry (20% relative humidity) operating conditions benefit fuel cell designs based on proton exchange membranes (PEMs) and hydrogen due to simplified system design and increasing tolerance to fuel impurities. In this paper, presented are preparation, partial characterization, and multi-scale modeling of such PEMs based on cross-linked, sulfonated poly(1,3-cyclohexadiene) (xsPCHD) blends and block copolymers with poly(ethylene glycol) (PEG). These low cost materials have proton conductivities 18 times that of current industry standard Nafion at hot, dry operating conditions. Among the membranes studied, the blend xsPCHD-PEG PEM displayed the highest proton conductivity, which exhibits a morphology with higher connectivity of the hydrophilic domain throughout the membrane. Simulation and modeling provide a molecular level understanding of distribution of PEG within this hydrophilic domain and its relation to proton conductivities. Finally, this study demonstrates enhancement of proton conductivity at high temperature and low relative humidity by incorporation of PEG and optimized sulfonation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Photoelectron Spectroscopy Analysis of Nafion-Containing Samples: Pitfalls, Protocols, and Perceptions of Physicochemical Properties

X-ray photoelectron spectroscopy (XPS) is one of the most common techniques used to analyze the surface composition of catalysts and support materials used in polymer electrolyte membrane (PEM) fuel cells and electrolyzers, providing important insights for further improvement of their properties. Characterization of catalyst layers (CLs) is more challenging, which can be at least partially attributed to the instability of ionomer materials such as Nafion during measurements. This work explores the stability of Nafion during XPS measurements, illuminating and addressing Nafion degradation concerns. The extent of Nafion damage as a function of XPS instrumentation, measurement conditions, and sample properties was evaluated across multiple instruments. Results revealed that significant Nafion damage to the ion-conducting sulfonic acid species (>50% loss in sulfur signal) may occur in a relatively short time frame (tens of minutes) depending on the exact nature of the sample and XPS instrument. This motivated the development and validation of a multipoint XPS data acquisition protocol that minimizes Nafion damage, resulting in reliable data acquisition by avoiding significant artifacts from Nafion instability. The developed protocol was then used to analyze both thin film ionomer samples and Pt/C-based CLs. Comparison of PEM fuel cell CLs to Nafion thin films revealed several changes in Nafion spectral features attributed to charge transfer due to interaction with conductive catalyst and support species. This study provides a method to reliably characterize ionomer-containing samples, facilitating fundamental studies of the catalyst-ionomer interface and more applied investigations of structure-processing-performance correlations in PEM fuel cell and electrolyzer CLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of fluid shear stress on polyelectrolyte multilayers by neutron scattering studies

The structure of layer-by-layer (LbL) deposited nanofilm coatings consists of alternating polyethylenimine (PEI) and polystyrenesulfonate (PSS) films deposited on a single crystal quartz substrate. LbL-deposited nanofilms were investigated by neutron reflectomery (NR) in contact with water in the static and fluid shear stress conditions. The fluid shear stress was applied through a laminar flow of the liquid parallel to the quartz/polymer interface in a custom-built solid–liquid interface cell. The scattering length density profiles obtained from NR results of these polyelectrolyte multilayers (PEM), measured under different shear conditions, showed proportional decrease of volume fraction of water hydrating the polymers. For the highest shear rate applied (ca. 6800 s –1 ) the water volume fraction decreased by approximately 7%. The decrease of the volume fraction of water was homogeneous through the thickness of the film. Since there were not any significant changes in the total polymer thickness, it resulted in negative osmotic pressures in the film. The PEM films were compared with the behavior of thin films of thermoresponsive poly(N-isopropylacrylamide) (pNIPAM) deposited via spin-coating. The PEM and pNIPAM differ in their interactions with water molecules, and they showed opposite behaviors under the fluid shear stress. In both cases the polymer hydration was reversible upon the restoration of static conditions. Furthermore, a theoretical explanation is given to explain this difference in the effect of shear on hydration of polymeric thin films.

36 MATERIALS SCIENCE↗

Evaluating the Case for Reduced Precious Metal Catalysts in Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolyzers are a key technology in decarbonizing hydrogen production. Though the market for PEM electrolyzer systems is growing, there are concerns that the cost and availability of precious metal catalysts utilized in today’s commercial systems can limit deployment. Herein, we show that while the availability of Ir should not impede deployment in the near term, the inelasticity of the Ir commodity price is cause for immediate concern. Here we emphasize that diversifying catalyst materials, even with other precious metals, can reduce system costs and mitigate supply chain risk. Furthermore, we analyze the trade-offs between catalyst capital cost and catalyst activity for a range of operating conditions (i.e., capacity factor, electricity price). The framework presented herein is a first step toward establishing performance targets (i.e., activity, stability, material cost) for reduced precious metal and non-precious metal catalysts as a function of PEM electrolyzer operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing the Crystalline Architecture of Semicrystalline Ion Exchange Membranes for the Design of Conductive and Durable Alkaline Anion Exchange Membranes

Alkaline anion exchange membrane (AAEM) fuel cells offer a cost-effective alternative to proton exchange membrane (PEM) fuel cells by eliminating the need for expensive precious metal catalysts. In both PEMs and AAEMs, semicrystalline polymers are a common choice, as the crystalline domains can act as mechanical reinforcements that limit swelling and promote mechanical durability in the material. However, spatially resolved characterization of crystalline organization in ion exchange membranes beyond ensemble-averaged X-ray scattering is underrepresented, likely in part due to ionization damage limitations in soft materials. Here, in this study, we resolve the nanometer-size crystallites in semicrystalline ion exchange membranes by applying cryogenic four-dimensional scanning transmission electron microscopy (cryo-4D-STEM) along with data-processing algorithms designed to optimize signals at a low dose to minimize radiation damage. We investigate the effects of synthesis components, including molecular weight and thermal treatment, on a model system of AAEMs in comparison to Nafion, the most commonly used and commercially successful PEM today. We find that excess water uptake in polymer membranes, a property directly associated with weak mechanical durability and with possible negative impacts on ion conductivity, can be reduced by over 30% by varying the polymer's crystalline morphology through changes in synthesis parameters such as molecular weight and thermal history. Our results indicate that this improvement is correlated with smaller crystalline domains with a more homogeneous distribution. More broadly, these results demonstrate how the crystalline architecture of polymer membranes can be tuned through their chemistry and thermal treatment in order to improve their conductivity and durability for commercial fuel cell performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-iridium-based electrocatalyst for durable acidic oxygen evolution reaction in proton exchange membrane water electrolysis

Iridium-based electrocatalysts remain the only practical anode catalysts for proton exchange membrane (PEM) water electrolysis, due to their excellent stability under acidic oxygen evolution reaction (OER), but are greatly limited by their high cost and low reserves. Here, in this study, we report a nickel-stabilized, ruthenium dioxide (Ni-RuO 2 ) catalyst, a promising alternative to iridium, with high activity and durability in acidic OER for PEM water electrolysis. While pristine RuO 2 showed poor acidic OER stability and degraded within a short period of continuous operation, the incorporation of Ni greatly stabilized the RuO 2 lattice and extended its durability by more than one order of magnitude. When applied to the anode of a PEM water electrolyser, our Ni-RuO 2 catalyst demonstrated >1,000 h stability under a water-splitting current of 200 mA cm -2 , suggesting potential for practical applications. Density functional theory studies, coupled with operando differential electrochemical mass spectroscopy analysis, confirmed the adsorbate-evolving mechanism on Ni-RuO 2 , as well as the critical role of Ni dopants in stabilization of surface Ru and subsurface oxygen for improved OER durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A non-precious metal hydrogen catalyst in a commercial polymer electrolyte membrane electrolyser

We demonstrate the translation of a low-cost, non-precious metal cobalt phosphide (CoP) catalyst from 1 cm 2 lab-scale experiments to a commercial-scale 86 cm 2 polymer electrolyte membrane (PEM) electrolyser. A two-step bulk synthesis was adopted to produce CoP on a high-surface-area carbon support that was readily integrated into an industrial PEM electrolyser fabrication process. The performance of the CoP was compared head to head with a platinum-based PEM under the same operating conditions (400 psi, 50 °C). CoP was found to be active and stable, operating at 1.86 A cm –2 for >1,700 h of continuous hydrogen production while providing substantial material cost savings relative to platinum. In conclusion, this work illustrates a potential pathway for non-precious hydrogen evolution catalysts developed in past decades to translate to commercial applications.

30 DIRECT ENERGY CONVERSION↗

Low-iridium stabilized ruthenium oxide anode catalyst for durable proton-exchange membrane water electrolysis

While mixing iridium (Ir) with ruthenium oxide (RuO 2 ) has proven to be an effective strategy for reducing Ir loading in anode catalysts for proton-exchange membrane (PEM) water electrolysers, achieving industrially relevant long-term stability typically requires an Ir-rich, Ru-lean combination. Here, in this study, by combining density functional theory with Metropolis Monte Carlo methods, we discovered that sufficient stabilization in the RuO 2 lattice could be achieved with less than 50 at.% of Ir, and that Ir in the first subsurface layer plays a critical role. By effectively dispersing Ir dopants within the RuO 2 lattice, we demonstrated an Ir:Ru atomic ratio of only 1:6 that exhibited exceptional stability for over 1,500 h of continuous water electrolysis at 2 A cm −2 . Our Ru 6 IrO x catalyst has the potential to reduce Ir loading by 80% compared with current commercial PEM water electrolysers, and its stability was further validated under industrial testing conditions in a 25-cm 2 PEM electrolyser.

36 MATERIALS SCIENCE↗

Deconvoluting charge-transfer, mass transfer, and ohmic resistances in phosphonic acid–sulfonic acid ionomer binders used in electrochemical hydrogen pumps

Ion-pair high-temperature polymer electrolyte membranes (HT-PEMs) paired with phosphonic acid ionomer electrode binders have substantially improved the performance of HT-PEM electrochemical hydrogen pumps (EHPs) and fuel cells. Here, blending poly(pentafluorstyrene-co-tetrafluorostyrene phosphonic acid) (PTFSPA) with Nafion™, and using this blend as an electrode binder, improved proton conductivity in the electrode layer resulting in a 2 W cm –2 peak power density of fuel cells at 240 °C (a HT-PEM fuel cell record). However, much is unknown about how phosphonic acid ionomers blended with perfluorosulfonic acid materials affect electrode kinetics and gas transport in porous electrodes. In this work, we studied the proton conductivity, electrode kinetics, and gas transport resistances of 3 types of phosphonic acid ionomers, poly(vinyl phosphonic acid), poly(vinyl benzyl phosphonic acid), and PTFSPA by themselves and when blended with Aquivion® (a perfluorosulfonic acid material).

08 HYDROGEN↗

Permutation invariant polynomial neural network approach to fitting potential energy surfaces. IV. Coupled diabatic potential energy matrices

A machine learning method is proposed for representing the elements of diabatic potential energy matrices (PEMs) with high fidelity. This is an extension of the so-called permutation invariant polynomial-neural network (PIP-NN) method for representing adiabatic potential energy surfaces. While for one-dimensional irreducible representations the diagonal elements of a diabatic PEM are invariant under exchange of identical nuclei in a molecular system, the off-diagonal elements require special symmetry consideration, particularly in the presence of a conical intersection. A multiplicative factor is introduced to take into consideration the particular symmetry properties while maintaining the PIP-NN framework. Here, we demonstrate here that the extended PIP-NN approach is accurate in representing diabatic PEMs, as evidenced by small fitting errors and by the reproduction of absorption spectra and product branching ratios in both H 2 O$(\tilde{X} / \tilde{B})$ and NH 3 $(\tilde{X} $/Ã) non-adiabatic photodissociation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic layer deposition of ultrathin platinum films on tungsten atomic layer deposition adhesion layers: Application to high surface area substrates

Platinum (Pt) atomic layer deposition (ALD) usually yields Pt nanoparticles during initial film growth. In contrast, deposition of continuous and ultrathin Pt films is needed for many important applications, such as the oxygen reduction reaction in polymer electrolyte membrane (PEM) fuel cells. A continuous and high radius of curvature Pt film is more stable and has a higher area-specific activity than the Pt nanoparticles commonly used in PEM fuel cells. However, the Pt film must be ultrathin and have a large surface area to be cost effective. In this paper, a review of earlier Pt ALD studies on flat substrates is presented that demonstrates that tungsten, with a higher surface energy than platinum, can serve as an adhesion layer to achieve Pt ALD films that are continuous at ultrathin thicknesses of ∼1.5 nm. This work utilized MeCpPtMe{sub 3} and H{sub 2} plasma as the Pt ALD reactants. The deposition of continuous and ultrathin Pt ALD films using MeCpPtMe{sub 3} and H{sub 2} plasma as the reactants is then studied on two high surface area substrate materials: TiO{sub 2} nanoparticles and 3M nanostructured thin film (NSTF). Transmission electron microscopy (TEM) showed uniform and continuous Pt films with thicknesses of ∼4 nm on the TiO{sub 2} nanoparticles. TEM with electron energy loss spectroscopy analysis revealed W ALD and Pt ALD films with thicknesses of ∼3 nm that were continuous and conformal on the high aspect ratio NSTF substrates. These results demonstrate that cost effective use of Pt ALD on high surface area substrates is possible for PEM fuel cells.

36 MATERIALS SCIENCE↗

Characterization of commercial proton exchange membrane materials after exposure to beta and gamma radiation

Proton Exchange Membrane (PEM) type electrolysis cells have a potential use for tritium removal and heavy water upgrading. AECL is currently exposing various commercial PEM materials to both gamma (Cobalt-60 source) and beta (tritiated water) radiation to study the effects of radiation on these materials. This paper summarizes the testing methods and results that have been collected to date. The PEM materials that are or have been exposed to radiation are: Nafion 112, 212, 117 and 1110. Membrane characterization pre- and post- exposure consists of non-destructive inspection (FTIR, SEM/XPS), mechanical (tensile strength, percentage elongation, and modulus), electrical (resistance), or chemical (ion-exchange capacity - IEC). It has appeared that the best characterization techniques to compare exposed versus unexposed membranes were IEC, ultimate tensile strength and percent elongation. These testing techniques are easy and cheap to perform. The non-destructive tests, such as SEM and FTIR did not provide particularly useful information on radiation-induced degradation. Where changes in material properties were measured after radiation exposure, they would be expected to result in poorer cell performance. However, for modest γ-radiation exposure, all membranes showed a slight decrease in cell voltage (better performance). In contrast, the one β-radiation exposed membrane did show the expected increase in cell voltage. The counterintuitive trend for γ-radiation exposed membranes is not yet understood. Based on these preliminary results, it appears that γ- and β-radiation exposures have different effects.

07 ISOTOPE AND RADIATION SOURCES↗

High Performance, Low Cost Hydrogen Generation from Renewable Energy

Renewable hydrogen from proton exchange membrane (PEM) electrolysis is gaining strong interest in Europe, especially in Germany where wind penetration is already at critical levels for grid stability. For this application as well as biogas conversion and vehicle fueling, megawatt (MW) scale electrolysis is required. Proton has established a technology roadmap to achieve the necessary cost reductions and manufacturing scale up to maintain U.S. competitiveness in these markets. This project represents a highly successful example of the potential for cost reduction in PEM electrolysis, and provides the initial stack design and manufacturing development for Proton’s MW scale product launch. The majority of the program focused on the bipolar assembly, from electrochemical modeling to subscale stack development through prototyping and manufacturing qualification for a large active area cell platform. Feasibility for an advanced membrane electrode assembly (MEA) with 50% reduction in catalyst loading was also demonstrated. Based on the progress in this program and other parallel efforts, H2A analysis shows the status of PEM electrolysis technology dropping below $3.50/kg production costs, exceeding the 2015 target.

08 HYDROGEN↗

Center for Electrocatalysis, Transport Phenomena, and Materials (CETM) for Innovative Energy Storage - Final Report

EFRC vision. The direct use of organic hydrides in fuel cells as virtual hydrogen carriers that generate stable organic molecules, protons, and electrons upon electro-oxidation and can be electrochemically charged by re-hydrogenating the oxidized carrier was the major focus of the Center for Electrocatalysis, Transport Phenomena and Materials for Innovative Energy Storage (EFRC-ETM). Compared to a hydrogen-on-demand design that includes thermal decomposition of organic hydrides in a catalytic reactor, the proposed approach is much simpler and does not require additional dehydrogenation catalysts or heat exchangers. Further, this approach utilizes the advantages of a flow battery (i.e., separation of power and energy, ease of transport and storage of liquid fuels) with fuels that have system energy densities similar to current hydrogen PEM fuel cells. EFRC challenges. Two major EFRC challenges were electrocatalysis and transport phenomena. The electrocatalysis challenge addresses fundamental processes which occur at a single molecular catalyst (microscopic level) and involve electron and proton transfer between the hydrogen rich and hydrogen depleted forms of organic liquid fuel and the catalyst. To form stable, non-radical dehydrogenation products from the organic liquid fuel, it is necessary to ensure fast transport of at least two electrons and two protons (per double bond formation). The same is true for the reverse hydrogenation reaction. The transport phenomena challenge addresses transport of electrons to/from the electrocatalyst and the current collector as well as protons across the polymer membrane. Additionally it addresses prevention of organic liquid fuel, water and oxygen transport through the PEM. In this challenge, the transport of protons or molecules involves multiple sites or a continuum (macroscopic level) and water serves as a proton conducting medium for the majority of known sulfonic acid based PEMs. Proton transfer in the presence of prospective organic liquid fuels was studied. During EFRC program various types of electrocatalysts, classes of fuels, and membranes have been investigated.

25 ENERGY STORAGE↗

Roots Air Management System with Integrated Expander

PEM fuel cells remain an emerging technology in the vehicle market with several cost and reliability challenges that must be overcome in order to increase market penetration and acceptance. The DOE has identified the lack of a cost effective, reliable, and efficient air supply system that meets the operational requirements of a pressurized PEM 80kW fuel cell as one of the major technological barriers that must be overcome. This project leveraged Roots positive displacement development advancements and demonstrated an efficient and low cost fuel cell air management system. Eaton built upon its P-Series Roots positive displacement design and shifted the peak efficiency making it ideal for use on an 80kW PEM stack. Advantages to this solution include: • Lower speed of the Roots device eliminates complex air bearings present on other systems. • Broad efficiency map of Roots based systems provides an overall higher drive cycle fuel economy. • Core Roots technology has been developed and validated for other transportation applications. Eaton modified their novel R340 Twin Vortices Series (TVS) Roots-type supercharger for this application. The TVS delivers more power and better fuel economy in a smaller package as compared to other supercharger technologies. By properly matching the helix angle with the rotor’s physical aspect ratio, the supercharger’s peak efficiency can be moved to the operating range where it is most beneficial for the application. The compressor was designed to meet the 90 g/s flow at a pressure ratio of 2.5, similar in design to the P-Series 340. A net shape plastic expander housing with integrated motor and compressor was developed to significantly reduce the cost of the system. This integrated design reduced part count by incorporating an overhung expander and motor rotors into the design such that only four bearings and two shafts were utilized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Hydrocarbon Ionomers for Durable Proton Exchange Membranes

Proton exchange membrane fuel cells (PEMFCs) are considered efficient, environmentally friendly power sources. However, there are no commercially available hydrocarbon-based proton exchange membrane (PEM) capable of achieving the DOE’s 2020 technical targets, some of which include 0.02 Ω.cm 2 area specific proton resistance at maximum operating temperature and water partial pressures from 40-80kPa, durability of 20,000 cycles (Mechanical), >500Hours (Chemical), and 20,000 cycles without 20% loss in OCV (Chemical and Mechanical), maximum operating temperature of 120°C, and $20/m 2 (at 500,000 systems/year). While significant progress has been made over the previous two decades in the development of polymer electrolytes for fuel cells, their widespread commercialization has been largely hindered by the high-cost and low-durability. NanoSonic has developed novel, cost-effective, quaternary ammonium- functionalized hydrocarbon ionomers doped with phosphoric acid as intermediate temperature (120°C) PEMs for fuel cells as energy efficient transportation alternative to internal combustion engines. These next-generation polymer membranes possess excellent film forming and mechanical properties, exceptional hydrated dimensional stability, have good proton conductivity at low relative humidity (RH) and exhibit superb stability over current state of the art perfluorosulfonic acid (PFSA) ionomers used under the harsh operating conditions of PEM fuel cells. NanoSonic’s engineered and manufactured a library of membrane types, identified a subset of best performers, and are evaluating these materials in partnership with Los Alamos National Laboratory. Membrane electrode assembly (MEA) fabrication was successfully demonstrated in during Phase I. Initial results utilizing these novel polymer membranes and non-optimize MEAs generated during this project demonstrate good proton conductivity at 80-200°C at zero humidification (RH=0%) and have notably low high frequency resistance (HFR). NanoSonic’s membranes show superior acid retention in comparison to the reference doped PBI membranes, an attribute credited to the formation of stable ionic acid pairs, in addition to polar nteractions with the polymer backbone.

30 DIRECT ENERGY CONVERSION↗

CRADA: Data Acquisition and Tomographic Software Development

Dr. Raymond R. Raylman, Professor and Vice Chair for Research, Radiology Department at WVU was the Principal Investigator for the project. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and the chief contact with WVU. The responsibility of Jefferson Lab was to facilitate optimization of data acquisition software, conversion of JLab Fortran iterative positron emission mammography computer code to C++ and to act as a computer code repository. During the two year project interactions and exchange of information was directed by Dr. Raylman and Dr. Wesienberger. WVU provided the expertise that allowed JLab to continue development of the current JLab data acquisition software referred to as JDAQ. JDAQ is a highly flexible Java language based data acquisition tool that helps to minimize software induced dead-time while maintaining the highest possible data rates from a JLab built FPGA based analog-to-digital convertor (ADC). JDAQ interfaces directly with the FPGA based multi-channel ADCs. Using JDAQ it is possible process data from a number of different detector types such as the PET systems at WVU. Because of the inherent flexibility of our processing software, we are also able adjust detector readout parameters during operation to provide the best possible data presentation and calibration parameters. To accommodate the high rate nature of PET detector systems JDAQ was designed to be scalable across an Ethernet network as well as for multi-cpu computer systems, and it also has the capability to synchronize many ADCs connected to multiple computers. During the project WVU will provided iterative reconstruction algorithm expertise and Fortran programming assistance to facilitate the conversion to C++ of a JLab developed Fortran positron emission mammography (PEM) reconstruction code. Also WVU provided acceptance testing of the new C++ based PEM reconstruction code. The PEM code is a maximization (MLEM) image reconstruction program that created images from the list-mode data acquired from the PET system.

97 MATHEMATICS AND COMPUTING↗