Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Field funneling and range straggling in partially depleted silicon surface-barrier detectors

The effects of field funneling and range straggling have been quantitatively observed in the measurement of charge collected from alpha-particle tracks in silicon surface-barrier charged-particle detectors. The method described may be used for the straight-forward measurement of charge collection from heavy ions in these and other semiconductor devices.

Zoutendyk, J. A.↗

Drift time variations in CdZnTe detectors measured with alpha-particles: Their correlation with the detector’s responses

Homogeneity of properties related to material crystallinity is a critical parameter for achieving high-performance CdZnTe (CZT) radiation detectors. Unfortunately, this requirement is not always satisfied in today's commercial CZT material due to high concentrations of extended defects, in particular subgrain boundaries, which are believed to be part of the causes hampering the energy resolution and efficiency of CZT detectors. In the past, the effects of subgrain boundaries have been studied in Si, Ge and other semiconductors. It was demonstrated that subgrain boundaries tend to accumulate secondary phases and impurities causing inhomogeneous distributions of trapping centers. It was also demonstrated that subgrain boundaries result in local perturbations of the electric field, which affect the carrier transport and other properties of semiconductor devices. The subgrain boundaries in CZT material likely behave in a similar way, which makes them responsible for variations in the electron drift time and carrier trapping in CZT detectors. In this work, we employed the transient current technique to measure variations in the electron drift time and related the variations to the device performances and subgrain boundaries, whose presence in the crystals were confirmed with white beam X-ray diffraction topography and infrared transmission microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MERiT Onboard the CeREs: A Novel Instrument to Study Energetic Particles in the Earth's Radiation Belts

The Miniaturized Electron pRoton Telescope, MERiT, is a low‐mass, low‐power, compact instrument using an innovative combination of particle detectors, sensor electronics, and onboard processing. MERiT is flying on the Compact Radiation belt Explorer, CeREs, a 3U CubeSat launched into a low earth orbit of 500‐km altitude and inclination of 85° on 16 December 2018. The primary and secondary science goals of CeREs are to investigate electron microbursts and to study solar particles. MERiT comprises a stack of solid state detectors (SSD) behind space facing avalanche photo diodes (APDs) surrounded by W‐Al shielding to reduce side‐penetrating particle background. The APD‐SSD combination enables measurement of electrons from 5 to 200 keV and 1 to 8 MeV; protons from 200–400 keV and 7–100 MeV in differential channels with energy resolution ΔE/E≈30% for both electrons and protons. MERiT measures microbursts with a high time resolution ranging from 4 to 16 ms and solar particles with a cadence of 1 s. MERiT energy channels and cadences are software configurable via algorithms and lookup tables residing on a field‐programmable gate array. The lookup tables can be changed via ground commands. MERiT geometry factor is 31 sq.cm‐sr and optimized to measure microbursts with the instrument viewing the local zenith in orbit. MERiT enables investigation of dynamical processes of radiation belt electron energization and loss, solar electron and proton transport, and their access to the Earth's polar caps. We describe the MERiT sensor design, calibration, operational modes, data products, and science goals.

Kanekal, S. G.↗

First light from beam neutrinos on an LAPPD in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is both a physics experiment and a technology testbed for next-generation light-based neutrino detection. In this paper, we report the first demonstration of a fully integrated Large Area Picosecond Photodetector (LAPPD) operating in a running neutrino beam experiment. Particular focus is given to the design, commissioning, and successful deployment of the Packaged ANNIE LAPPD (PAL), a waterproof, self-triggering module incorporating fast waveform digitization and precision timing synchronized to the ANNIE detector subsystems. We identify beam-correlated LAPPD data frames consistent with charged-current neutrino interactions observed in multiple detector subsystems, establishing the first detection of neutrino-induced Cherenkov light with an LAPPD. These results validate the system-level performance of LAPPDs under realistic experimental conditions — including long-term stability, timing synchronization, and event matching with conventional PMT and muon detector systems — marking a critical step toward their deployment in future large-scale neutrino and particle detectors.

Cherenkov detectors↗

Monolithic collimator and energy analyzer for ion spectrometry

Disclosed are various examples related to ion or particle spectrometry utilizing a monolithic collimator and energy analyzer. In one example, a particle selection device includes a single substrate including a curved channel energy analyzer section and a straight channel collimator section, wherein particles pass through the collimator section and enter the energy analyzer section of the substrate. The channel outlets in the collimator section are aligned with the channel inlets of the energy analyzer section. Electric and/or magnetic fields can be applied across the channels of the energy analyzer for ion or particle discrimination. A particle detector at the outlet of the energy analyzer section can provide indications of detected ions and/or particles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The problem of low energy particle measurements in the magnetosphere

The accurate measurement of low energy (less than 100 eV) particle properties in the magnetosphere has been difficult, partly because of the low density of such particles, but more particularly because of spacecraft interference effects. Some early examples of how these phenomena have affected particle measurements on an OGO spacecraft are presented. Data obtained with the UCSD particle detectors on ATS-6 are then presented showing how some of these difficulties have been partially overcome. Future measurements of low energy particles in the magnetosphere can be improved by: (1) improving the low energy resolution of detectors; (2) building electrostatically clean spacecraft; (3) controlling spacecraft potential; and (4) using auxiliary measurements, particularly wave data.

Whipple, E. C., Jr.↗

Separating beam-induced and cosmogenic muon backgrounds in the ICARUS detector

Due to high cosmic ray flux near the earth's surface, the rejection of cosmogenic muon backgrounds is a preeminent concern for particle detectors using Liquid Argon Time Projection Chamber (LArTPC) technology. One such detector, ICARUS of the short baseline neutrino experiment, also observes muons generated from neutrino interactions with nuclei in the surrounding rock. Our analysis exploits the differences between cosmogenic and rock-generated muons to separate rock-generated muons from the background. We develop a selection with 96.5\% efficiency and 81\% accuracy. Use of this selection on data and Monte-Carlo indicates monte-carlo may underestimate the true rock muon flux. These results have implications for calibration of the ICARUS detector and tuning of simulation.

Wells, David↗

Application of the backward extrapolation method to pulsed neutron sources

We report particle detectors operated in pulse mode are subjected to the dead-time effect. When the average of the detector counts is constant over time, correcting for the dead-time effect is simple and can be accomplished by analytical formulas. However, when the average of the detector counts changes over time it is more difficult to take into account the dead-time effect. When a subcritical nuclear assembly is driven by a pulsed neutron source, simple analytical formulas cannot be applied to the measured detector counts to correct for the dead-time effect because of the sharp change of the detector counts over time. This work addresses this issue by using the backward extrapolation method. The latter can be applied not only to a continuous (e.g. californium) external neutron source but also to a pulsed external neutron source (e.g. by a particle accelerator) driving a subcritical nuclear assembly. Finally, the backward extrapolation method allows to obtain from the measured detector counts both the dead-time value and the real detector counts.

43 PARTICLE ACCELERATORS↗

The Convolutional Visual Network for Identification and Reconstruction of NOvA Events

In 2016 the NOvA experiment released results for the observation of oscillations in the vμ and ve channels as well as ve cross section measurements using neutrinos from Fermilab’s NuMI beam. These and other measurements in progress rely on the accurate identification and reconstruction of the neutrino flavor and energy recorded by our detectors. This presentation describes the first application of convolutional neural network technology for event identification and reconstruction in particle detectors like NOvA. The Convolutional Visual Network (CVN) Algorithm was developed for identification, categorization, and reconstruction of NOvA events. It increased the selection efficiency of the ve appearance signal by 40% and studies show potential impact to the vμ disappearance analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Astrophysically Important 19Ne States Studied with the 2H(18F,alpha+15O)n Reaction

The nuclear structure of {sup 19}Ne near the proton threshold is of interest for understanding the rates of proton-induced reactions on {sup 18}F in novae. Analogues for several states in the mirror nucleus {sup 19}F have not yet been identified in {sup 19}Ne indicating the level structure of {sup 19}Ne in this region is incomplete. The {sup 18}F(d;n){sup 19}Ne and {sup 18}F(d,p){sup 19}F reactions have been measured simultaneously at E{sub c.m.} = 14.9 MeV. The experiments were performed at the Holifield Radioactive Ion Beam Facility (HRIBF) of Oak Ridge National Laboratory (ORNL) by bombarding a 720-mg/cm{sub 2} CD{sub 2} target with a radioactive {sup 18}F beam. The {sup 19}Ne states of interest near the proton threshold decay by breakup into a and {sup 15}O particles. These decay products were detected in coincidence with position-sensitive E-{Delta}E silicon telescopes. The {alpha} and {sup 15}N particles from the break up of the mirror nucleus {sup 19}F were also measured with these detectors. Particle identification, coincidence, and Q-value requirements enable us to distinguish the reaction of interest from other reactions. The reconstruction of relative energy of the detected particles reveals the excited states of {sup 19}Ne and {sup 19}F which are populated. The neutron (proton) angular distributions for states in {sup 19}Ne ({sup 19}F) were extracted using momentum conservation. The observed states in {sup 19}Ne and {sup 19}F will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for the Higgs and Physics Beyond the Standard Model with the CMS Electromagnetic Calorimeter

The Compact Muon Solenoid (CMS) Experiment is a general purpose particle detector experiment at the Large Hadron Collider (LHC) at the European Laboratory for Nuclear Research (CERN). The LHC is the world’s highest energy particle collider, providing proton-proton collisions up to a center-of-mass energy of 13 TeV. The primary aim of the LHC and the CMS Experiment is to discover new physics at this high energy frontier. In 2012, the discovery of the Higgs boson at the LHC marked a crucial milestone in the Standard Model (SM) of particle physics and ushered in the beginning of a new era of exploration at the high energy frontier. Since this discovery, two key areas of study were the characterization of the new particle to confirm that it is, indeed, the predicted SM Higgs boson and also the examination of possible deviations from the SM that may hint at new physics. As a member of the CMS collaboration, the main interest of PI Orimoto has been the study of electromagnetic objects (electrons and photons) as a critical ingredient in the characterization of the Higgs boson, and as a window into physics beyond-the-SM (BSM). To this end, the Orimoto group has led numerous physics analyses ranging from SM Higgs boson studies, searches for exotic production and decay of the Higgs boson, as well as searches for supersymmetric particles. Moreover, the Orimoto group has made significant contributions to the CMS electromagnetic calorimeter (ECAL), the sub-detector responsible for the precise measurement of the energies of electrons and photons. The Orimoto group’s contributions have been recognized with many leadership roles and high profile conference presentations. This report outlines the group’s products and accomplishments from the award period (June 2013 through July 2018).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE LONGITUDINAL PROPERTIES OF A SOLAR ENERGETIC PARTICLE EVENT INVESTIGATED USING MODERN SOLAR IMAGING

We use combined high-cadence, high-resolution, and multi-point imaging by the Solar-Terrestrial Relations Observatory (STEREO) and the Solar and Heliospheric Observatory to investigate the hour-long eruption of a fast and wide coronal mass ejection (CME) on 2011 March 21 when the twin STEREO spacecraft were located beyond the solar limbs. We analyze the relation between the eruption of the CME, the evolution of an Extreme Ultraviolet (EUV) wave, and the onset of a solar energetic particle (SEP) event measured in situ by the STEREO and near-Earth orbiting spacecraft. Combined ultraviolet and white-light images of the lower corona reveal that in an initial CME lateral 'expansion phase', the EUV disturbance tracks the laterally expanding flanks of the CME, both moving parallel to the solar surface with speeds of {approx}450 km s{sup -1}. When the lateral expansion of the ejecta ceases, the EUV disturbance carries on propagating parallel to the solar surface but devolves rapidly into a less coherent structure. Multi-point tracking of the CME leading edge and the effects of the launched compression waves (e.g., pushed streamers) give anti-sunward speeds that initially exceed 900 km s{sup -1} at all measured position angles. We combine our analysis of ultraviolet and white-light images with a comprehensive study of the velocity dispersion of energetic particles measured in situ by particle detectors located at STEREO-A (STA) and first Lagrange point (L1), to demonstrate that the delayed solar particle release times at STA and L1 are consistent with the time required (30-40 minutes) for the CME to perturb the corona over a wide range of longitudes. This study finds an association between the longitudinal extent of the perturbed corona (in EUV and white light) and the longitudinal extent of the SEP event in the heliosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

The Longitudinal Properties of a Solar Energetic Particle Event Investigated Using Modern Solar Imaging

We use combined high-cadence, high-resolution, and multi-point imaging by the Solar-Terrestrial Relations Observatory (STEREO) and the Solar and Heliospheric Observatory to investigate the hour-long eruption of a fast and wide coronal mass ejection (CME) on 2011 March 21 when the twin STEREO spacecraft were located beyond the solar limbs. We analyze the relation between the eruption of the CME, the evolution of an Extreme Ultraviolet (EUV) wave, and the onset of a solar energetic particle (SEP) event measured in situ by the STEREO and near-Earth orbiting spacecraft. Combined ultraviolet and white-light images of the lower corona reveal that in an initial CME lateral "expansion phase," the EUV disturbance tracks the laterally expanding flanks of the CME, both moving parallel to the solar surface with speeds of approx 450 km/s. When the lateral expansion of the ejecta ceases, the EUV disturbance carries on propagating parallel to the solar surface but devolves rapidly into a less coherent structure. Multi-point tracking of the CME leading edge and the effects of the launched compression waves (e.g., pushed streamers) give anti-sunward speeds that initially exceed 900 km/s at all measured position angles. We combine our analysis of ultraviolet and white-light images with a comprehensive study of the velocity dispersion of energetic particles measured in situ by particle detectors located at STEREO-A (STA) and first Lagrange point (L1), to demonstrate that the delayed solar particle release times at STA and L1 are consistent with the time required (30-40 minutes) for the CME to perturb the corona over a wide range of longitudes. This study finds an association between the longitudinal extent of the perturbed corona (in EUV and white light) and the longitudinal extent of the SEP event in the heliosphere.

acceleration of particles↗

The C shell, an active detector of UH nuclei

This paper gives a brief description of the current status of the present program to develop a modular array of large electronic particle detectors. These modules were designed to study the UH nuclei in the cosmic radiation with eventual deployment on the Space Station or at a lunar base. This array would determine the abundances of elements from iron to the actinides and directly measure the energies of the lower energy nuclei. If the array was deployed on the Space Station, it would use the geomagnetic threshold to place limits on the higher energy nuclei, thus studying the energy spectrum up to about 10 GeV/n. Deployed at a lunar base, it would detect nuclei with energies down to the instrumental limit. Smaller versions could be flown on balloons to test and refine the modules.

Waddington, C. J.↗

A dark matter search using the final CDMS-II data and 100 mm SuperCDMS germanium detector ionization test

Astrophysical observations indicate that approximately 85% of the matter in the universe is nonluminous, nonbaryonic, and nonrelativistic (cold) dark matter. Weakly Interacting Massive Particles (WIMPs) are a particularly well motivated dark matter particle candidate. They would be thermally produced in the early universe and their relics account for the current dark matter abundance. WIMP candidate particles are naturally provided by extensions to the Standard Model of particle physics, such as supersymmetry. The Cryogenic Dark Matter Search (CDMS) experiment operates cryogenic germanium and silicon particle detectors in the low-background environment of the Soudan Underground Laboratory in northern Minnesota to search for WIMP-nucleus scatters while rejecting electron-recoil background. The detectors simultaneously measure the ionization and phonon energies of each scattering event. The difference in ionization yield (ratio of ionization energy to recoil energy) discriminates nuclear recoils from the electron-recoil background efficiently.More sensitive detectors are required to probe the WIMP parameter space with lower WIMP-nucleon scattering cross sections. To support the R&D effort especially the detector R&D and characterization of the SuperCDMS experiment, a new CDMS test facility has been developed on the University of Minnesota campus. This thesis documents the test facility and the work involved in its development. In the test facility, we performed the first ionization collection efficiency measurements of the ionization test devices. The test devices are fabricated with detector-grade germanium crystals that are 100 mm in diameter, which is the largest available, and 33 mm in thickness. The measured efficiencies are consistent with the earlier measurements conducted with smaller Ge crystals, demonstrating that these 100 mm crystals can be used for development of the next generation dark matter detectors.Improvements of data analysis methods can also potentially improve the sensitivity of an experiment. The data taken during the last four runs of CDMS II with total raw exposure 612 kg-day were reprocessed with improved ionization pulse reconstruction algorithm. We present the classic timing analysis with the reprocessed data in this thesis. For the four runs combined, this analysis resulted in a new WIMP-nucleon cross section 4.4×10 -44 cm 2 for a WIMP mass of 70 GeV, which is a factor of 1.6 improvement compared to the original c58 classic timing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

The VEPP-2000 electron-positron collider: First experiments

In 2007, at the Institute of Nuclear Physics (Novosibirsk), the construction of the VEPP-2000 electron-positron collider was completed. The first electron beam was injected into the accelerator structure with turned-off solenoids of the final focus. This mode was used to tune all subsystems of the facility and to train the vacuum chamber using synchrotron radiation at electron currents of up to 150 mA. The VEPP-2000 structure with small beta functions and partially turned-on solenoids was used for the first testing of the 'round beams' scheme at an energy of 508 MeV. Beam-beam effects were studied in strong-weak and strong-strong modes. Measurements of the beam sizes in both cases showed a dependence corresponding to model predictions for round colliding beams. Using a modernized SND (spherical neutral detector), the first energy calibration of the VEPP-2000 collider was performed by measuring the excitation curve of the phimeson resonance; the phi-meson mass is known with high accuracy from previous experiments at VEEP-2M. In October 2009, a KMD-3 (cryogenic magnetic detector) was installed at the VEPP-2000 facility, and the physics program with both the SND and LMD-3 particle detectors was started in the energy range of 1-1.9 GeV. This first experimental season was completed in summer 2010 with precision energy calibration by resonant depolarization.

43 PARTICLE ACCELERATORS↗

Commercial and Cost Effective Production of Gas Electron Multiplier (GEM) Foils

The nuclear and high energy physics research community is constantly searching for new and improved tracking and radiation detectors. The introduction of micropattern detectors has opened new opportunities for improving the rate capabilities, as well as the spatial and time resolution of particle detectors in these applications. GEM detectors in particular have received enormous interest for use in detectors planned for a number of new and upgraded experiments at many different research facilities. These include both the STAR and PHENIX experiments at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory, experiments at the Thomas Jefferson National Laboratory, Oak Ridge National Laboratory, and at the future electron-positron Linear Collider. At the present time, CERN is not able to supply foils in sufficient quantities to accommodate the needs of these experiments. Compounding this problem, there is a strong interest in GEM foils for numerous other applications, such as in astrophysics, medical imaging and detectors for homeland security. It would therefore be of significant benefit to the research community to develop a commercial source of GEM foils for all of these applications. Tech-Etch is in a unique position to develop this technology for commercial use. Tech-Etch has not only experience in numerous related high precision etched Kapton® products, but it also has strong ties with several research institutions (namely Brookhaven, Yale and MIT) that can help develop and evaluate the performance of the GEM foils produced at Tech-Etch. Additionally, since Tech-Etch is a small company, it also has the capability to produce a large variety of part configurations, as well as the flexibility to shift production methods, equipment, and chemistry to optimize the GEM foil manufacturing process without being constrained by existing work running on high volume continuous coil equipment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber

Finding unequivocal evidence of dark matter interactions in a particle detector is a major goal of research in physics. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nuclei down to the so-called neutrino floor, in a mass range from a few GeV to hundreds of TeV. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all types of events observed in the detector, is essential for the optimal design of the new experiment. In this article, we report on a specific set of events, namely, standard two-pulse scintillation–ionization signals with a third small amplitude pulse, occurring within the 440 μ s data acquisition window of standard events. Some of these events are due to the photoionization of the TPC cathode. We compare our results with those published by collaborations using liquid xenon time projection chambers, which observed a similar phenomenon, and, in particular, with a recent paper by the LUX Collaboration (D.S. Akerib et al. Phys.Rev.D 102, 092004 (2020)) From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths of around 128 nm, in liquid argon. Also, both experiments observe events likely related to the photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be an order of magnitude lower in DarkSide-50 than in LUX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗