SEARCH · Engineering Papers
Results for “Notes”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Publisher's Note: 'An interpolation formula for the ion flux to a small particle in collisional plasmas' [Phys. Plasmas 15, 114503 (2008)]
No abstract prepared.
Publisher's Note: 'Noniterative reconstruction of tokamak equilibria' [Phys. Plasmas 16, 022505 (2009)]
No abstract prepared.
Publisher's Note: 'Measurements of electric charge and screening length of microparticles in a plasma sheath' [Phys. Plasmas 16, 043704 (2009)]
No abstract prepared.
Publisher's Note: 'Flat Bogomolnyi-Prasad-Sommerfeld domain walls on two-dimensional Kaehler-Ricci soliton' [J. Math. Phys. 50, 063514 (2009)]
No abstract prepared.
Note on the Poisson structure of the damped oscillator
The damped harmonic oscillator is one of the most studied systems with respect to the problem of quantizing dissipative systems. Recently Chandrasekar et al. [J. Math. Phys. 48, 032701 (2007)] applied the Prelle-Singer method to construct conserved quantities and an explicit time-independent Lagrangian and Hamiltonian structure for the damped oscillator. Here we describe the associated Poisson bracket which generates the continuous flow, pointing out that there is a subtle problem of definition on the whole phase space. The action-angle variables for the system are also presented, and we further explain how to extend these considerations to the discrete setting. Some implications for the quantum case are briefly mentioned.
Note: A combined aerodynamic lens/ambient pressure x-ray photoelectron spectroscopy experiment for the on-stream investigation of aerosol surfaces
We discuss a new approach for the measurement of the surfaces of free aerosol particles with diameters from 50 to 1000 nm. Particles in this size range have significant influence on the heterogeneous chemistry in the atmosphere and affect human health. Interfacing an aerodynamic lens to an ambient pressure x-ray photoelectron spectrometer permits measurement of the surface chemical composition of unsupported aerosol particles in real time. We discuss the basic considerations for the design of such an instrument, its current limitations and potentials for improvement. Results from a proof-of-principle experiment on silicon oxide particles with average diameters of 270 nm are shown.
Publisher's Note: 'A stochastic structural stability theory model of the drift wave-zonal flow system' [Phys. Plasmas 16, 112903 (2009)]
No abstract prepared.
Note: Large rotation measurement using half shaded square patterns
As the manufacturing technology ranging from micrometer to nanometer scale requires more planar motion devices, the demand for sensor measuring the planar motion is increasing. However, the previous sensors measuring the planar motion had a drawback in the measurement of rotation, especially regarding yaw angle. In this article, we present a novel method to measure large yaw angle with the planar position sensor based on the half shaded square patterns. The measuring range of the yaw angle is restricted to 45 deg. in this article, but it can be expanded to as much as 360 deg. with an improvement of the algorithm.
Note: A simple, convenient, and reliable method to prepare gold scanning tunneling microscope tips
A simple method to prepare gold tips for scanning tunneling microscopy has been introduced. In this method, electrochemical etching without a hazardous electrolyte was employed. The setup uses basic laboratory instrumentation to control the etching process. This avoids purchasing complicated, expensive, and dedicated equipment for tip preparation. A procedure to optimize the etching parameters by setting the current limit is described. Etched tips were checked with both optical and scanning electron microscopy.
Publishers Note: 'Anodic vacuum arc developed nanocrystalline Cu-Ni and Fe-Ni thin film thermocouples' [J. Appl. Phys. 106, 113717 (2009)]
No abstract prepared.
Note: Construction of x-ray scattering and x-ray absorption fine structure beamline at the Pohang Light Source
A new hard x-ray beamline, 10B KIST-PAL beamline (BL10B), has been designed and constructed at the Pohang Light Source (PLS) in Korea. The beamline, operated by Pohang Accelerator Laboratory-Korean Institute of Science and Technology consortium, is dedicated to x-ray scattering (XRS) and x-ray absorption fine structure (XAFS) experiments. X rays with photon energies from 4.0 to 16.0 keV are delivered to the experimental station passing a collimating mirror, a fixed-exit double-crystal Si(111) monochromator, and a toroidal mirror. Basic experimental equipments for XAFS measurement, a high resolution diffractometry, an image plate detector system, and a hot stage have been prepared for the station. From our initial commissioning and performance testing of the beamline, it is observed that BL10B beamline can perform XRS and XAFS measurements successfully.
Note: Measurement of saturable absorption by intense vacuum ultraviolet free electron laser using fluorescent material
Advances in free electron lasers (FELs) which generate high energy photons are expected to open novel nonlinear optics in the x-ray and vacuum ultraviolet (VUV) regions. In this paper, we report a new method for performing VUV-FEL focusing experiments. A VUV-FEL was focused with Kirkpatrick-Baez optics on a multilayer target, which contains fused silica as a fluorescent material. By measuring the fluorescence, a 5.6x4.9 {mu}m{sup 2} focal spot was observed in situ. Fluorescence was used to measure the saturable absorption of VUV pulses in the tin layer. The transmission increases nonlinearly higher with increasing laser intensity.
Note: Application of laser produced plasma K{alpha} x-ray probe in radiation biology
A dedicated radiation biology x-ray generation and exposure system has been developed. 8.0 keV in energy x-ray pulses generated with a femtosecond-laser pulse was used to irradiate sample cells through a custom-made culture dish with a silicon nitride membrane. The x-ray irradiation resulted in DNA double-strand breaks in the nucleus of a culture cell that were similar to those obtained with a conventional x-ray source, thus demonstrating the feasibility of radiobiological studies utilizing a single burst of x-rays focused on single cell specimens.
Note: Low density and long plasma channels generated by laser transversely ignited ablative capillary discharges
A technique is developed to reduce the jitter associated with ablative capillary discharges. A laser pulse propagating perpendicularly to the axis of the capillary and focused onto a copper wire creates a plasma that initiates the discharge. This transverse laser ignition method has several advantages over previous techniques employing a laser pulse collinear with the capillary, including increased capillary lifetime and simpler arrangement of the igniting and the driving pulses for laser-wakefield acceleration. Using this technique long, low density plasma channels are produced with low jitter.
A note on wave equation in Einstein and de Sitter space-time
We consider the wave propagating in the Einstein and de Sitter space-time. The covariant d'Alembert's operator in the Einstein and de Sitter space-time belongs to the family of the non-Fuchsian partial differential operators. We introduce the initial value problem for this equation and give the explicit representation formulas for the solutions. We also show the L{sup p}-L{sup q} estimates for solutions.
Note: Characterization of the plasma parameters of a capillary discharge-produced plasma channel waveguide to guide an intense laser pulse
We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Nomarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 400 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.
Note: X-ray radiography for measuring chemical diffusion in metallic melts
A x-ray radioscopy technique for measuring in situ chemical diffusion coefficients in metallic melts is presented. The long-capillary diffusion measurement method is combined with imaging techniques using microfocus tubes and flat panel detectors in order to visualize and quantitatively analyze diffusive mixing of two melts of different chemical composition. The interdiffusion coefficient as function of temperature and time is obtained by applying Fick's diffusion laws. Tracking the time dependence of the mean square penetration depth of the mixing process allows to detect changes in the mass transport caused by convective flow. The possibility to sort out convective mass transport contributions from analysis enhances significantly the accuracy compared to the conventional long-capillary diffusion measurement method with postmortem analysis. The performance of this novel diffusion measurement method with x-ray radiography technique is demonstrated by a diffusion experiment in an Al-Ni melt.